EXECUTIVE ENGINEER
R.D SPL DIVISION, GODDA.
CONSTRUCTION OF BRIDGE ACROSS GANGTA RIVER AT BETWEEN ASOTA TO LAUGAY PANCHAYAT IN MAHAGAMA BLOCK OF GODDA DISTRICT.
2026_RDSPL_116776_1
RWD/SD/GODDA/04/2026-27
Open Tender
Civil Works - Bridges
Percentage
548 days
MAHAGAMA
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
₹9.2 L
4 Aug 2026
4 Aug 2026
31 Aug 2026
4 Aug 2026
29 Aug 2026
4 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation for structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) i) Ordinary Soil (Excavation upto 3.0m depth) | 1 | Cum | 57.4 | ₹57.4 |
| 2 | Levelling course (PCC M15) for Pile cap | 1 | Cum | 3,405.6 | ₹3,405.57 |
| 3 | Cement concrete for reinforced concrete M-25 in pile cap complete as per drawing and Technical Specification | 0.66 | Cum | 4,295.8 | ₹2,818 |
| 4 | Supplying, fiiting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications. | 0.45 | tonne | 87,394.8 | ₹39,152.87 |
| 5 | Plain/Reinforced cement concrete (RCC Grade M25) in substructure complete as per drawing and technical specifications. | 0.88 | Cum | 4,630.9 | ₹4,075.19 |
| 6 | Supplying, fiiting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specification. | 0.92 | tonne | 87,744.9 | ₹80,725.31 |
| 7 | Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return all with 100 mm dia AC pipe, extending through the full width of the structures with slope of 1V:20H towards drawing foce. Complete as per drawing and Technical specifications. | - | Each | 110.5 | - |
| 8 | Providing and laying of filter media with granular materials/tone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRTH specifications to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification. | - | Cum | 1,645.3 | - |
| 9 | Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessrories as per drawing and Technical Specifications. | 0.58 | cm³ | 0.81 | ₹0.47 |
| 10 | Furnishing and placing Reinforced/Prestressed cement concrete (RCC Grade M30) in super-structure (for T-beam & slab) as per drawing and Technical Specification. | - | Cum | 5,495.9 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
TENDERDOCUMENT.pdf
Tender Documents • 1.55 MB
BOQ_157885.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].