Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹13.5 L+₹8,615 (0.64%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹14.0 L+₹51,675 (3.84%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹14.0 L+₹59,302 (4.41%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹15.7 L+₹2.3 L (16.9%)Rejected-Finance DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹35,000
Closing Date
12 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
CERTAIN REPAIR TO INTERNAL ELECTRIFICATION IN MD ACCN INCLUDING FITTING AND FIXTURE, GEYSERS, EXHAUST FANS, CEILING FANS, OTHER MISC ITEMS AND REPAIR/MAINT TO RUNWAY LIGHTING SYSTEM ALONGWITH CONNECTED ITEMS AT 8 FBSU, AF STATION AWANTIPUR
2020_MES_377298_1
GE (AF) AWA-14/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹35,000
Yes
28 Oct 2020
14 Sept 2020
14 Oct 2020
14 Sept 2020
12 Oct 2020
28 Sept 2020
60 days
Amount
Taking down carefully aluminium/copper point wiring (light, bell, fan, socket) complete including batten/casing caping/conduit, block, ceiling rose, holder, fittings and terminal box sheets complete, stacking material at site and making good the disturbed surface of walls/ floor to match with existing surface ., complete all as specified and directed.
Point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm with and including PVC casing caping, ISI marked with all connected accessories including one single core multistranded PVC insulated FRLS type, 1.5sqmm copper conductor cable unsheathed as earth continuity cable including concealed pressed steel GI terminal boxes not less than 1.2mm thick with 3mm thick laminated sheet cover for mounting of switches, socket, fan regulators, complete all as specified and as directed for the following:-
(a) One light /fan/bell point controlled by one No, one way 5/6 Amps switch.
(b) One 3/5 pin socket outlet, 5/6 Amp controlled by one No, one way switch on same board.
(c) One 3/5 pin socket outlet, 5/6 Amp, independent, controlled by one No. one way switch on independent board.
Description all as per serial item No. 2 here-in-before, but using cable of size 2.50sqmm (for phase & neutral) and 2.5sqmm as continuous earth cable for 15/16 Amps socket outlet independent point on independent board, complete all as specified and as directed.
Point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in existing conduit including one single core multistranded PVC insulated FRLS type, 1.5sqmm copper conductor cable unsheathed as earth continuity cable including 3mm thick laminated sheet cover for mounting of switches, socket, fan regulators, complete all as specified and as directed for the following:-
(a) One light /fan/bell point controlled by one No, one way 5/6 Amps switch.
(b) One 3/5 pin socket outlet, 5/6 Amp controlled by one No, one way switch on same board.
(c) One 3/5 pin socket outlet, 5/6 Amp, independent, controlled by one No. one way switch on independent board.
Description all as per serial item No. 4 here-in-before, but using cable of size 2.50sqmm (for phase & neutral) and 2.5sqmm as continuous earth cable for 15/16 Amps socket outlet independent point on independent board, complete all as specified and as directed.
Piano type switch one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz, complete all as specified and as directed.
Piano type bell push switch, one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz, complete all as specified and as directed.
Piano type socket outlet, flush type, 5 pin, 5/6 Amps, 230 volts AC, 50 Hz, multipurpose type, complete all as specified and as directed.
Piano type switch socket combination, flush type, 6 pin, 6/16 Amps, 230 volts AC, 50 Hz, multipurpose type, complete all as specified and as directed.
Electronic type ceiling fan regulator, 230 volts, single phase, flush type, complete all as specified and as directed.
Ceiling rose 3 terminals, PVC/polycarbonate/bakelite, isolated body, 230 volts AC, 50 Hz, complete all as specified and as directed.
Electric call bell, ding dong type suitable for 230 volts, single phase AC supply, complete all as specified and as directed.
Replacement of existing LED tube light fitting with new LED tube light fitting box type 230 volts, AC suitable for & including 18/20 watts LED tube rod with bipin holders prewired, LED driver including making of electrical connection with & including three core flexible copper conductor cable of suitable size, complete all as specified and as directed. Make: Havells Model: Regal batten for Fitting and Photon Ultra LED for tube rod or equivalent in Philips/Crompton.
Replacement of existing LED tube light fitting with new LED tube light fitting box type 230 volts AC suitable for & including 8 watts LED tube rod including bipin holders prewired, LED driver including making of electrical connection with and including three core flexible copper conductor cable of suitable size, complete all as specified and as directed. Make of fitting: Crompton model: Mirrorlite or equivalent in Havells/Philips and make of LED tube: Compton model: Retro LED or equivalent in Havells/Philips.
Replacement of existing LED wall light fitting with new LED wall light fittings 9 watt, 230 volts AC, indoor type made up of polycarbonate complete with B-22 type lamp holder, LED Lamp 9 watts, connector block pre-wired including making of electrical connection with & including two core flexible copper conductor cable of suitable size with all accessories , complete all as specified and as directed. Make: Havells Model City-1 or equivalent in Philips /Crompton.
Replacement of existing LED bulk head light fittings with new LED bulk head light fittings 10 watt, 230 volts AC made up of pressure die cast housing, IP65 protection, 5700K including making of electrical connection with & including three core flexible copper conductor cable of suitable size with all accessories, complete all as specified and as directed. Make: Crompton cat part No. LBHN-10-CDL or equivalent in Philips/Havells.
Replacement of existing LED post top lantern of any wattage with new LED post top lantern 40 watt made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP-65 protection, complete all as specified and as directed. Make: Bajaj cat part No. BGCL 40W LED WH or equivalent in Philips/Havells
Takingdown submain wiring of any size including casing caping terminated in batten by disconnecting the same from main board/ switch and keeping aside in safe custody and making the surface good , complete all as specified and as directed.
Takingdown submain wiring of any size from existing conduit terminated in batten by disconnecting the same from main board/ switch and keeping aside in safe custody and making the surface good complete all as specified and as directed . Note : Conduit shall not to be taken down
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4sqmm complete drawn in and including casing caping of suitable size (ISI marked) and its accessories along with 1x 4sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and as directed. Note :- 2 +1 run of 4Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4sqmm complete drawn in existing conduit with 1x 4sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and as directed. Note :- 2 +1 run of 4Sqmm cable shall be measured as one running metre.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6sqmm complete drawn in and including casing caping ISI marked of suitable size and its accessories along with 1x 6sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified. Note :- 2 +1 run of 6Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6sqmm complete drawn in existing conduit along with 1x 6sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and as directed. Note :- 2 +1 run of 6Sqmm cable shall be measured as one running metre.
Replacement of existing DB's double door With new factory made load line DB's double door made out of CRCA mild steel sheet with insulating material like polyester epoxy quoted surface mounting 4 way TPN 415 volts, vertical type, surface mounting with suitable busbar, neutral link and earth link suitable for MCCB TP as incomer and MCB SP/TP as out going complete with and including one No. MCCB 100 Amps, 3 pole, 10 kA fixed type for incoming, complete all as specified and as directed.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure DB TPN 4 way, double door, 415 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB TP/TPN as incomer and MCB SP as outgoing, complete all as specified and as directed.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure DB SPN 4 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and as directed.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure DB SPN 8 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and as directed.
MCB SPN, 40-63 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type,fixed in repair, complete all as specified and as directed.
MCB TPN, 40-63 Amps, 415 volts, 10 kA rupturing capacity, 'C' curve type, fixed in repair, complete all as specified and as directed.
Replacement of existing fan capacitor with new fan capacitor with wire terminals of capacity 2.5 Mfd, 230 volts AC, complete all as specified and as directed.
Replacement of existing fan capacitor with new fan capacitor with wire terminals of capacity 3.15 Mfd, 230 volts AC, complete all as specified and as directed.
Replacement of existing fan capacitor with new fan with capacitor wire terminals of capacity 4.0 Mfd, 230 volts AC, complete all as specified and as directed.
Replacement of existing rubber reel with new rubber reel suitable for ceiling fan/Exhaust fan/cabin fan of any type/make/size, complete all as specified and as directed.
Replacement of existing down rod with new existing down rod of 1' height fabricated out of MS pipe 10 mm dia heavy duty duly painted with white paint suitable to hang ceiling fan of any description, make and model, complete all as specified and as directed.
Replecement of existing heavy gauge ceiling fan hanging clamp with new heavy gauge ceiling fan hanging clamp fabricated out of MS flat with nut bolts with split pins, complete all as specified and as directed.
Overhauling of fan of any type and any make by opening, cleaning, greasing, oiling of fan motor after testing the faults including replacement of minor parts and re-assembling, complete all as specified and as directed. Note: Spare parts and winding shall be measured and paid separately.
Replacement of existing ball bearing with new ball bearing suilable for ceiling/exhaust/cabin/ wall/pedestrial fan of any type/make/size, complete all as specified and as directed.
Replacement of existing bush with new bushsuitable for ceiling/exhaust/cabin/wall/ pedestrial fan of any type/make/size, complete all as specified and as directed
Transportation of rotor of fan any type and sweep to work shop for rewinding/repair work and returning back to site complete all as directed. Note:- Rewinding will be measured and paid separately.
Removing old/burnt winding, cleaning of slots/pitches by using cleaning material by removing the insulating materials and then rewinding (i.e renewal of winding) the fans with appropriate/same gauge of super enamelled copper wire and insulating material, varnishing, drying the winding for adequate period to remove the moisture content and strengthening the winding and testing to the speed and flow of the fans any make, complete all as specified and as directed for the following type of fans :-
Ceiling fan 1200/1400 mm sweep.
Exhaust fan 300/380/450 mm sweep.
Wall mounted/cabin fan 400/450 mm sweep.
Pedestal fan 400/450mm sweep.
Replacement of existing fan blades with new fan blades heavy duty mild steel of any make suitable for exsiting pattern and colour scheme including screws, Complete all as specified and as directed for following type of fans:-
Ceiling fan 1200/1400 mm sweep (set of three blades).
Exhaust fan 300/380/450 mm sweep.
Wall mounted/cabin fan 400/450 mm sweep.
Pedestal fan 400/450mm sweep.
Earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4mm dia bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20mm bore from bottom of earth pit to top of electrode and 20mm GI pipe light grade for earth wire protection complete with earth pit inplain cement concrete 1:2:4, type B0 using 12.5mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete 1:2:4, type B-I , using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I, and as directed . Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of galvanized iron wire 4mm dia, complete all as specified and as directed.
Replacement of existing rigid non metallic PVC conduit with new 25mm dia medium grade rigid non metallic PVC conduit alongwith its fixing accessories and making good to the disturbed surface to match the existing, complete all as specified and as directed.
Replacement of existing casing caping with new 25mm wide casing caping ISI marked medium gradealongwith its fixing accessories and making good to the disturbed surface to match the existing, complete all as specified and as directed.
Taking down carefully electric geyser of any type and capacity complete opening of the geyser and replacing the defective parts including disconnecting electric and water supply connection and reassembling after cleaning and replacing defective parts and re-installing the same in original position and making necessary electric and water supply connection and testing complete all as specified and as directed. Note :- (i) Any accessories found unserviceable that shall be replaced under respective items of this Sch (ii). Superviser collect the complaints daily from office and feedback daily basis , and provide the complaint slip book as per sample.
Supply only, syphon assembly with rubber gasket, including nuts, bolts, washers etc. for geysers of following capacity , complete all as specified and as directed:-
50 Litres capacity geysers.
35 Litres capacity geysers.
25 Litres capacity geysers.
Mild steel galvanised iron medium grade water tubing 15mm bore (ISI marked) with screwed and socket joints, with all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. fixed to wall and ceiling or laid under floors etc. making holes, as in repairs, complete all as specified and as directed.
Supply only inner tank, vessel made of copper sheet 22 gauge , ISI marked factory made for suitable pressure of following capacity, complete all as specified and as directed:-
50 Litres capacity geysers.
35 Litres capacity geysers.
25 Litres capacity geysers.
Supply and fixing heating element of capacity 1.5 KW (Round/Triangular) ISI marked suitable for geyser (as per sample), complete all as specified and as directed. Make-Microne/Globo.
Description all as per serial item No 50 here- in-before , but of capacity 2 KW.
Description all as per serial item No 50 here-in-before, but of capacity 3 KW.
Supply only glass wool heat insulation superior quality suitable for geyser of capacity 25/35/50 Litres, complete all as specified and as directed.
Supply and fixing PVC insulated shethed cable 3 core flexible copper conductor of size 1.5 sqmm fire proof, complete all as specified and as directed.
Supply and fixing of drain plug for geyser, complete all as specified and as directed.
Supply and fixing of safety valve for geyser, complete all as specified and as directed.
Supply and fixing , 3 pin top, 16 Amps capacity, complete all as specified and as directed.
Socket out let, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts, Complete all as specified and as directed.
Supply and fixing of indicator lamp for geyser of any type as per existing in geyser, Complete all as specified and as directed.
Supply and fixing of thermostat switch suitable for 50/35/25 litres capacity geysers as per sample, Complete all as specified and as directed.
Supply and fixing of push type thermostat switch suitable for 50/35/25 litres capacity geysers as per sample, Complete all as specified and as directed.
PVC connection mesh type for cold/Hot water as per sample, Complete all as specified and as directed .
15 Amps, three pin socket suitable for matel clad, Complete all as specified and as directed.
15 Amps, three pin top suitable for matel clad, Complete all as specified and as directed .
Stop valve, 15mm bore ,cast copper alloy, chromium plated, fancy type, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed , complete all as specified and as directed.
Replacement of existing Sheet steel plug and socket DB's with new Sheet steel plug & socket DB's SP with metal clad 2 pin & earth plug and socket SPN, 20 Amps, 230 volts AC, concealed type, complete with & including one MCB SP, 20 Amps, 10 kA, including grouting in wall and making good to disturbed surfaces to match existing, complete all as specified and as directed.
Replacement of old unserviceable anchor bolt with new anchor bolt 12mm dia, 100mm long, complete all as specified and as directed. Note- Achor bolt shall be grouted with hammer drill only.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cables or other items and getting out in soft/loose soil, complete all as specifed and as directed.
Returning filling in, soil including spreading leveling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and as directed.
Removing excavated material (Soil) to a distance not exceeding 50 metre and depositing where directed in a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and as directed.
Sand cushioning to underground cable 8 cm thick layers below the cable and 15 cm thick above the cable in trenches using fine screened river sand, complete all as specified and as directed. Note :- Punned thickness shall be measured and paid.
Well burnt old size sub class 'B' bricks of nominal size 230X115X075 mm abutting each other for cable protection, complete all as specified and as directed.
Re-Laying of old serviceable bricks obtained from taking out of cable perpendicular to the axis of the cable, for protection of cable, complete all as specified and as directed.
Taking out Runway armoured cable of size 6 sqmm 3.3KV and keeping aside for the purpose of rerouting/relaying in new location/for requisite replacement/further disposal complete including taking out bricks, complete all as specified and as directed. Note: (i) Earth work shall be measured and paid separately (ii) Cable to be taking down are for singnal communication having solid joints. special care should be taken to stack the cable.
Labour only for relaying, connecting and testing of Runway cable of any size and rating as retrived from serial item No 74 here-in-before, complete all as specified and as directed.
Labour only for jointing of cable with straight through heat shrinkable joints for runway cables of 6 sqmm copper cable 3.3 KV HT including testing, complete all as specified and as directed. Note:-Joints will be provided by Airforce Authority.
Taking out runway lights of any type and refixng in the position as directed including taking out loop connections and refixing of loop connections,complete all as specified and as directed. Note for serial item No 68 to 77 :- The work to be executed under these items are urgent nature of work and shall be comlpeted on the same day. This factor shall be deemed considered while quoting unit rates aganist these items .
Note :- An amount of Rs. 36,448.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S LATIF AHMAD MIR
M/S LEO TRADERS
M/S Bali Agencies
M/s Jaipal Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .