| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 CrAccepted-AOC 1804 SECTOR 2 ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹22.5 Cr Quoted ₹22.6 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹22.7 CrRejected-AOC 858 SECTOR 23 127021 | BHIWANI | HARYANA | 127021 | ₹22.7 Cr | L2 | Rejected-AOC Reject |
| 3 | L3₹24.6 CrRejected-AOC MANSA | MANSA | MANSA | PUNJAB | ₹24.6 Cr | L3 | Rejected-AOC Reject |
| 4 | L4₹24.9 CrRejected-AOC HOUSE NO 953 SECTOR 23 HUDA BHIWANI TEHSIL AND DISTRICT BHIWANI | BHIWANI | BHIWANI | HARYANA | ₹24.9 Cr | L4 | Rejected-AOC Reject |
| 5 | Not Admitted-Fee/PreQual/Technical MITTAL FARM LOHARU ROAD CHARKHI DADRI 127306 | CHARKI DADRI | HARYANA | 127306 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹23.3 Cr
EMD Value
₹46.5 L
Closing Date
1 Jul 2024, 12:00 pmClosed
M/Garh Canal W.S.Divn. Narnaul
Executive Engineer M/Garh Canal W.S.Divn. Narnaul
Constructing 5 No. Canal water Storage Tank at villages Banihari, Sirohi Bahali, Bhungarkha, Gothari and Dhani Bisna (Nayan) to provide irrigation facilities through sprinkler system in Nangal Choudhary Constituency (Under Atal Bhujal Yoajna).
2024_HRY_381388_1
20243C9F5FD0 8F07 4426 81A4 05B9393390FA159IRR
Open Tender
Civil Works
365 days
GOTHRI BANIHARI SEROHI BIHALI BHUNGARKA DHAN B
4 documents required · 4 mandatory
₹20,000
₹46.5 L
Yes
XEN MGC W/S Division, NARNAUL
21 Aug 2024
21 Jun 2024
1 Jul 2024
21 Jun 2024
1 Jul 2024
21 Jun 2024
24 Jun 2024
Amount
Supplying, fixing, jointing, testing and commissioning of 300mm dia DI swing check type reflux (non returned valve) (IVC/VAG make) of P.N. 1.0 having resilient sheet conforming to IS-5312-1986 and amended upto date with pressure release valve arrangement with ISI marked specification including cost of all required material and accessories complete in all respect to the satisfaction of Engineer in Charge.
Supply, erection, testing of 3 core copper wire with ISI marked for making connection with LT Panel Board to vacuum pump and dewatering pump and other electric appliances with underground system in PVC/flexible pipes/ Cable tray with all required accessories like thimble etc. as directed by Engineer-in-Charge complete in all respect 2.50 mm sq. three core (For Vaccum Pump)
Supplying of 200 mm i/d PVC Single socketed type 6 Kg pressure pipe as per IS: 4895 with ISI marked
Supplying, fixing, jointing, testing and commissioning of 100 mm i/d Automatic DI Air valve single chamber type consisting two Orifice venting system with 3 functions (Supply and release of air as well as automatic venting during operation) of (IVC/VAG make) as conforming to IS-14845-2000 as amended upto date with ISI mark incluidng drilling, taping, screwing on DI Rising main including supply and fixing 100 mm i/d D.I. pipeline upto height of 3.00 mtr. including all required TandP, supply and fixing of D.I. specials complete in all respect to the satisfaction of Engineer in Charge.
Supplying, fixing, jointing, testing and commissioning of scour/ sluice valve of 150 mm i/d (IVC/VAG Make) of PN 1.6 having resilient sheet conforming to IS-14846-2000 and amended upto date with ISI marked specification (to be Installed alongwith 300mm i/d DI NRV for scour purpose of 300 mm i/d Raw Water Rising main) incluiding supply and fixing of 150 mm i/d D.I. pipe of required length and DI specials as reqiured in site condition complete in all respect to the satisfaction of Engineer in Charge.
Supply of XLPE 11 kv HT aluminium conductor 35sqmm 3 XLPE armoured cable with ISI marked standared make complete in all respect upto entire statisfaction of the Engineer in charge of work
Supply, erection, testing of 3 core copper wire with ISI marked for making connection with LT Panel Board to vacuum pump and dewatering pump and other electric appliances with underground system in PVC/flexible pipes/ Cable tray with all required accessories like thimble etc. as directed by Engineer-in-Charge complete in all respect 2.50 mm sq. three core (For Vaccum Pump only)
Supply erection testing and commissioning in HT epoxy type cable box for jointing of cable. Required for complete erecting of the same such as thimble lugs. Solder compound etc. complete in respect to the satisfaction of Engineer-In-Charge. a) For outdoor installation b) For indoor installation
Supply of LT aluminium conductor 240sqmm 3 1/2 core armoured cable with ISI marked standard make (i.e. Havells/Polycab/RR Kable) complete in respect to the satisfaction of Engineer-In-Charge.
Supply erection, and commissioning of Vaccum Pump 2.00 BHP (Kirloskar Make Model KV 30 32x32 mm 2900 RPM with CI Impeller) with all accessories i.e. 25 mm GI Pipe avg. 30 mtr., Goli Valve 25 mm 2 No. Goli Valve, 15 mm 6 No., Electric Panel 300 ltr. PVC water tank etc. complete in respect to the satisfaction of Engineer-In-Charge.
Supply erection testing and commissioning of Pressure gauge with glistening immersed complete in respect to the satisfaction of Engineer-In-Charge.
Supplying erection and testing of LED Light of 100 watts (Manufactured by reputed make i.e. Phillips/ Bajaj/ Crompton/ G.E./ Wipro) including all required fittings and accessories complete in respect to the satisfaction of Engineer-In-Charge.
Supplying, fixing, jointing, testing and commissioning of 300mm i/d DI sluice valves (IVC/VAG make) of PN 1.6 having resilient sheet conforming to IS-14846-2000 and amended upto date with ISI marked specification including cost of jointing material complete in all respect to the satisfaction of Engineer in Charge.
Supplying and fixing 300mm dia cast iron coller joint of class-10 marked with IS:8794 for use with D.I. K-9 pipes complete with 2 Nos. rubber rings marked with IS: 5382 and IS: 10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading , unloading and other accessories etc. complete in respect to the satisfaction of Engineer-In-Charge.
Supply, erection, testing of 95 sqmm single core copper wire with ISI marked standard make (i.e. Havells/Polycab/RR Kable) for making connection with LT Bus Bar and LT Panel Board to electric motor and other electric appliances with underground system in PVC/flexible pipes/ Cable tray with all required accessories like thimble etc. complete in respect to the satisfaction of Engineer-In-Charge.
Supply of LT aluminium conductor 185sqmm 3 1/2 core armoured cable with ISI marked standared make (i.e. Havells/Polycab/RR Kable) complete in respect to the satisfaction of Engineer-In-Charge.
Supply erection, testing and commissioning of Vacuum Circuit Breaker (VCB) for 11 KV HT Panel having degree of protection not less than IP-42, indoor, metal clad, free floor standing vertical cubicle, dead front, removal, back cover, fabricated with CRCA sheet suitable for 11 KV, 630 A, 3 Phase, 50 Hz, 350 MVA rapturing capacity Vacuum Circuit Breaker (VCBs), Horizontal draw out type spring charger mechanism, 110 V AC Triping coils, indicating lamps, anti pumping contactor, standard multi core terminals, standard wiring and earthing arrangement push buttons, standard paint electrolytic copper busbar mechanical interlocking arrangement indication arrangement closed/ open, spring, charges/ discharged as well as DC trip history tripped/ healthy, cable boxed and all standard fitting and accessories complete in respect to the satisfaction of Engineer-In-Charge. (Including third party inspection from CEIL)
Supply erection, testing and commisioning of equipment on HT metering panel 11 KV consisting of one no G.O switch, one No. Electric Trivector meter 3 phase 4 wire 0.5 class of accuracy on KW hour point Basis complete with HT CTs of 15/5 amp /110 VA burden and class of 0.5 accuracy and H.T.PT 11 KV - 15/5 Amp./ 110V burden and class of 0.5 accuracy including metering panel with complete accessories complete in respect to the satisfaction of Engineer-In-Charge.
Supply erection testing and commissioning of 300mm i/d Electronic FLOW METER (KRONE Make) with digital display including all other required accessories complete complete in respect to the satisfaction of Engineer-In-Charge.
Supplying and fixing 300mm i/d CI mechanical dismantling Joints of PN 1.0 with rubber gaskets and nut bolt of required size complete in respect to the satisfaction of Engineer-In-Charge.
Supply and erection of Horizontal centrifugal spilt casing type pumps conforming to all respect IS 6595-Part-II:1993 of following duties directly coupled to AC squirrel cage induction type electric motor conforming to IS 12615 with all required accessories complete in all respect (the make shall be of Kirloskar, Crompton, ABB, Siemens, NGFE/ GEC)(Including third party inspection from CEIL) Raw water pumping set of 6200 LPM with 90 mtrs head pump with squirrel cage induction type energy efficient electric motor of 1440 RPM, 3 phase 50 Hz as per specification of efficient class IE-3 complete in respect to the satisfaction of Engineer-In-Charge.
Supply, erection, testing and commissioning of wall mounted electrical Bus Bar panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1800x1200mm with 900mm deep having following accessories as below specification complete in respect to the satisfaction of Engineer-In-Charge. (Bus Bar pannel board for 2 Nos. pumping set of 6200 LPM with 90 Mtr. Head) 1. Incomer switch 800 Amp. 2. Copper bus bar chamber of 800 Amp. Capacity. 3. Volt meter 100x100mm range 0 to 500 V (AE/KAPPA/LandT) 4. Indicting Lamp One set 5. Copper Bus Bar (Size 60 mm x 12 mm) 3 Nos.
Supply, erection, testing of 120 sqmm single core copper wire with ISI marked (i.e. Havells/Polycab/RR Kable) for making connection with LT Bus Bar and LT Panel Board to electric motor and other electric appliances with underground system in PVC/flexible pipes/ Cable tray with all required accessories like thimble etc. as directed by Engineer-in-Charge complete in all respect.
Design, supply, installation, testing and commissioning of cubical type L.T. panel suitable for 630 V, 3 phase, 4 wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 16 SWG thick for frame work and covers with suitable angle iron frame work and completely powder coated of approximate size 1500x1200 mm with 900 mm deep, 3 mm thick for gland plates i/c cleaning and finishing complete with 7 tank process for approved shades, having 400 Amp. Capacity extensible type TPN copper Bus bar for high conductivity, DMC/SMC bus bar supports, Panel Manufacturer shall have CPRI test certificate for short circuit with stand capacity of 31 MVA for 1 Sec. bottom based channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common tinned copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Aluminum bus bar and control wiring with 2.5 sq. mm FRLS insulated copper conductor S/C Cable, Cable alleys, Cable gland plates in two half, i/c providing following switch gears etc. as required. The design and drawing of panel board will be approved from Engineer in-Charge before installation at site. 400 Amp. 36 KA Ics 4 pole, complete with spreader links, phase barriers and ROM of make : LandT D Sine, Schneider NSX compact, Siemens 3 VL, Digital Multi Functional Meter with CT of 400/5 Amp. and RYB indicator for phase identification of Make :LandT Vega Series or equivalent in ABB and Siemens, Schneider, Siemens, ABB Outgoing Feeder 1 No. 400 Amp. 36 KA Ics 3 Pole, complete with spreader links, phase barrier and ROM of Make : LandT D Sine. Schneider NSX Compact, Siemens 3VL, for existing feeder (existing load)(Including third party inspection from any Govt. Agency ( as approved by Engineer-In-Charge) make as per Haryana DGSandD rate contract approved manufacturer. i) 1 No. MCCB 400 Amp. 25 KA Ics 3 Pole, complete with spreader links, phase barrier and ROM of Make : LandT D Sine, Schneider NSX Compact, Siemens 3VL. ii) 3 No. Inline contractor for fully automatic ATS starter AC 3x200 Amp. of make MNX 70 of LandT or equivalent in ABB/Siemens. iii) 1 No. fully automatic ATS starter for motor with inside delta connection min 70A for 6 wire Connection Cat No. EMX3- 0023B-411 of LandT or Equivalent model 3RW44 of Siemens/PSTB of ABB. Note :- Suitable Size of Semiconductor fuse shall be used for Backup protection of fully automatic ATS starter Design, supply, installation, testing and commissioning of APFC Panel of 14.50 KVAR of suitable steps capacity suitable for operation on 415 plus 5% volt, 3 phase, 50 Hz, AC supply having heavy duty static capacitors (Without oil) of suitable rating complete with TP MCCB of 400 Amps. 36 KA (Ics=100%) capacity with L.T. Panel with adjustable thermal magnetic bases release for over current and short circuit protection as incomer of the panel, of suitable step microprocessor based power factor controller, duty contractors for each capacitors protected with suitable rating MCCBs of minimum 18 KA ICs breaking capacity having thermal magnetic release for over load and short note circuit protection, cooling fans for panel and Digital multifunction meter, Class-1.0, indicating lights, earthing the panel etc. as reqd. The Panel should be manufactured with 2mm thick CRCA sheet duly powder coated etc. The APFC Panel shall be in continuous with L.T. Panel. Makes of Capacitor/ contactor/ MCCB/ APFC Controller : LandT/ Siemens/ ABB complete in respect to the satisfaction of Engineer-In-Charge. (For run the squirrel cage induction type energy efficient electric motor of 1440 RPM, 3 phase 50 Hz as per specification of efficient class IE-3 to run the raw water pump having discharge 6200 LPM with 90 mtr. Head) (Including third party inspection from CEIL).
Supply and erection of Horizontal centrifugal spilt casing type pumps conforming to all respect IS 6595-Part-II:1993 of following duties directly coupled to AC squirrel cage induction type electric motor conforming to IS 12615 with all required accessories complete in all respect (the make shall be of Kirloskar, Crompton, ABB, Siemens, NGFE/ GEC)(Including third party inspection from CEIL) Raw water pumping set of 6200 LPM with 75 mtrs head pump with squirrel cage induction type energy efficient electric motor of 1440 RPM, 3 phase 50 Hz as per specification of efficient class IE-3 complete in respect to the satisfaction of Engineer-In-Charge.
Supply, erection, testing and commissioning of wall mounted electrical Bus Bar panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1800x1200mm with 900mm deep having following accessories as below specification complete in respect to the satisfaction of Engineer-In-Charge. (Bus Bar pannel board for 2 Nos. pumping set of 6200 LPM with 75 Mtr. Head) 1. Incomer switch 800 Amp. 2. Copper bus bar chamber of 800 Amp. Capacity. 3. Volt meter 100x100mm range 0 to 500 V (AE/KAPPA/LandT) 4. Indicting Lamp One set 5. Copper Bus Bar (Size 60 mm x 12 mm) 3 Nos.
Design, supply, installation, testing and commissioning of cubical type L.T. panel suitable for 630 V, 3 phase, 4 wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 16 SWG thick for frame work and covers with suitable angle iron frame work and completely powder coated of approximate size 1500x1200 mm with 900 mm deep, 3 mm thick for gland plates i/c cleaning and finishing complete with 7 tank process for approved shades, having 400 Amp. Capacity extensible type TPN copper Bus bar for high conductivity, DMC/SMC bus bar supports, Panel Manufacturer shall have CPRI test certificate for short circuit with stand capacity of 31 MVA for 1 Sec. bottom based channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common tinned copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Aluminum bus bar and control wiring with 2.5 sq. mm FRLS insulated copper conductor S/C Cable, Cable alleys, Cable gland plates in two half, i/c providing following switch gears etc. as required. The design and drawing of panel board will be approved from Engineer in-Charge before installation at site. 400 Amp. 36 KA Ics 4 pole, complete with spreader links, phase barriers and ROM of make : LandT D Sine, Schneider NSX compact, Siemens 3 VL, Digital Multi Functional Meter with CT of 400/5 Amp. and RYB indicator for phase identification of Make :LandT Vega Series or equivalent in ABB and Siemens, Schneider, Siemens, ABB Outgoing Feeder 1 No. 400 Amp. 36 KA Ics 3 Pole, complete with spreader links, phase barrier and ROM of Make : LandT D Sine. Schneider NSX Compact, Siemens 3VL, for existing feeder (existing load)(Including third party inspection from any Govt. Agency ( as approved by Engineer-In-Charge) make as per Haryana DGSandD rate contract approved manufacturer. i) 1 No. MCCB 400 Amp. 25 KA Ics 3 Pole, complete with spreader links, phase barrier and ROM of Make : LandT D Sine, Schneider NSX Compact, Siemens 3VL. ii) 3 No. Inline contractor for fully automatic ATS starter AC 3x200 Amp. of make MNX 70 of LandT or equivalent in ABB/Siemens. iii) 1 No. fully automatic ATS starter for motor with inside delta connection min 70A for 6 wire Connection Cat No. EMX3- 0023B-411 of LandT or Equivalent model 3RW44 of Siemens/PSTB of ABB. Note :- Suitable Size of Semiconductor fuse shall be used for Backup protection of fully automatic ATS starter Design, supply, installation, testing and commissioning of APFC Panel of 14.50 KVAR of suitable steps capacity suitable for operation on 415 plus 5% volt, 3 phase, 50 Hz, AC supply having heavy duty static capacitors (Without oil) of suitable rating complete with TP MCCB of 400 Amps. 36 KA (Ics=100%) capacity with L.T. Panel with adjustable thermal magnetic bases release for over current and short circuit protection as incomer of the panel, of suitable step microprocessor based power factor controller, duty contractors for each capacitors protected with suitable rating MCCBs of minimum 18 KA ICs breaking capacity having thermal magnetic release for over load and short note circuit protection, cooling fans for panel and Digital multifunction meter, Class-1.0, indicating lights, earthing the panel etc. as reqd. The Panel should be manufactured with 2mm thick CRCA sheet duly powder coated etc. The APFC Panel shall be in continuous with L.T. Panel. Makes of Capacitor/ contactor/ MCCB/ APFC Controller : LandT/ Siemens/ ABB complete in respect to the satisfaction of Engineer-In-Charge. (For run the squirrel cage induction type energy efficient electric motor of 1440 RPM, 3 phase 50 Hz as per specification of efficient class IE-3 to run the raw water pump having discharge 6200 LPM with 75 mtr. Head) (Including third party inspection from CEIL).
Bidder Name
Amount
Narender Singh Contractor (GSTN-06AXBPS0272N1Z8) BID ID -1103710
MAHA LAXMI CONSTRUCTION COMPANY(GSTN-NA)--1103627
M/s Nem Kumar-Tarsem Chand (JV)(GSTN-NA)--1101816
M/S SHREE BALAJI BUILDERS(GSTN-NA)--1103697
MAHA LAXMI CONSTRUCTION COMPANY
Narender Singh Contractor
M/s Nem Kumar-Tarsem Chand (JV)
M/S SHREE BALAJI BUILDERS
M/s Nem Kumar-Tarsem Chand (JV)
MAHA LAXMI CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid