Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAccepted-AOC CHINAPATTY H NO 359 CITY TOWN MAKUM P O P S MAKUM DIST TINSUKIA PIN 786170 | TINSUKIA | ASSAM | 786170 | ₹3.0 Cr | L1 | Accepted-AOC awarded |
| 2 | L2₹3.0 Cr+₹21,165 (0.07%)Rejected-AOC ASSAM CHANDMARI GUWAHATI 3 LOCATION ASSAM AS | ₹3.0 Cr+₹21,165 (0.07%) | L2 | Rejected-AOC Not awarded |
Tender Value
₹3.0 Cr
EMD Value
₹6 L
Closing Date
13 Dec 2024, 2:00 pmClosed
Chief Engineer., PWRD, Chandmari, Ghy-3
O/o the C.E., PWRD, Chandmari, Ghy-3
Imp of (1) Sadashiv T.E Gate to Sadashiv T.E L.p Schl of Sadashiv T.E., (2) Dhanjan T.E Rd of Dhanjan T.E., (3) Bajrangpur T.E Karwa Line Rd of Bajrangpur T.E. under RIDF-XXX for 2024-25 under Tinisukia,Doom dooma,Makum and Sadia TRD (Sadia LAC)
2024_PWD_40772_4
CE/Com/9/RIDF-XXX/24-25/12
Open Tender
Civil Works – Roads
Item Rate
270 days
Sadia
Please refer Tender documents.
4 documents required · 4 mandatory
₹6,000
₹6 L
Yes
O/o the C.E., PWRD, Chandmari, Ghy-3
20 May 2025
3 Dec 2024
13 Dec 2024
3 Dec 2024
13 Dec 2024
3 Dec 2024
3 Dec 2024 - 13 Dec 2024
6 Dec 2024
Amount
Clearing and grubbing road land including uprooting wild vegatation, grass, bushes,shrubs,saplins and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned upto lead of 1000 m etc. as per technical specification cl 201. (i) By Manual means ( B ) In area of non thorny jungle
Dismantling of existing structures like culverts , bridges retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.
Removing all types of Hume pipes and stacking within a lead of 1000m including Earthwork and dismantling of masonary works as per Technical specification clause 202 of Specifiction of Rural raods.
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m. as per technical specification clause 301.5 (a)From Private land
Construction of subgrade and earthen shoulders with approved material obtained from borrow pitrs with all lifts and leads, transporting to site,spreading,grading to required slope and compacted to meet requirement of table 300.2 with a lead upto 1000 m. as per technical specification clause 303.1 (a)From Private land
Granular Sub -base with Well Graded Material (Table 400.1) By Mix in place method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. ii ) For Grading II Material
WBM Grading 3 Using stone sceening Type- B 11.2mm for Gr. III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means.
Interlocking concrete block pavement Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504. A) Including Edge block/ Edge restraints
Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) (ii) Ordinary Kilometer stone (Precast)
Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc iii) 200 m stone (precast)
Providing & fixing of retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 8 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801 i) 600mm equilateral triangle
Providing & fixing of retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 8 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801, (i) 600mm circular
Providing & fixing of retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 8 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801, (i) 800mmx600mm rectangular
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawings. Three MS plates of 1,6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5mm size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes post duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to the middle plate by 47mm x 47mm of 12 SWG steel plate tube. All MS will be stove enameled on both sides. Lettering and printing arrow, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and annexure 1700.1
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusiveof surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance
Tree Plantation Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trenches, watering , fixing the tree guatrd and maintaining the plants for three year.
Construction of HPC 1000 mm dia Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (For face wall & bedding)
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
Bedding of pipe Type B (First Class) Bed Laying (First Class) bedding on well compacted sand, moorum as per Clause 1105 (ii) Granular bedding
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (C) 1000 mm dia
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (ii) P.C.C grade M 15 Nominal mix (1:2.5:5)
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
PRASANTA BORA (BID ID -250499)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .