Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAdmitted-Finance 01 MADHU BHAWAN FIRST FLOOR FLATE NO 01 NAWADIH DHANBAD JHARKHAND 828130 | DHANBAD | JHARKHAND | 828130 | L1 | Admitted-Finance | |
| 2 | Rejected-Technical AT DHORI STAFF QTR P O DHORI DIST BOKARO | BOKARO | JHARKHAND | 825102 | - | Rejected-Technical Reject | |
| 3 | Rejected-Technical 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical Reject |
| Sl No | Description | Qty | Unit | Vedant Enterprises L1 |
|---|---|---|---|---|
| .10 | Supply & providing of remote indication system with alarm for low voltage and in case of failure | 1 | Nos | 40,000 ₹40,000 Lowest |
| .20 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recess steel/PVC conduit as required.(4x6sq.mm) | 160 | mtr | 350 ₹56,000 Lowest |
| .30 | Supply and providing 110V battery Charger panel of sheet steel siniclure of 2 mm thick dust and vemin proof grey colour input and output terminals shall be provided at the boltom of the cabinet with suitable cable entry Lifting hooks earthing terminal self supported etc. suitable for 150 AH 2 volt x 65 nos lead acid battery. | 1 | Nos | 70,000 ₹70,000 Lowest |
| .40 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm | 115 | mtr | 325 ₹37,375 Lowest |
| .50 | Supply & Providing float charger having current rating 20A boost cum float charger having rating 25A with associated items like voltmeter for AC volt with voltage selector switch AC main fail relay. Ammeter to read input current with their current transformer & DC voltmeter with four position selector switch to read the voltage of float charger boost cum float charger battery and load with on-off position solid state DC under voltage relay solid state DC battery each fault relay annunciation circuit with Accept/reset/test push button buzzer | 1 | Nos | 4,35,000 ₹4,35,000 Lowest |
| .60 | Lead Acid maintenance free battery
Voltage - 2V
Capacity-150 Ah
Charging current-21Amps
Internal resistance 0.91 milli ohms
and 10 Nos of additional spare battery. | 65 | Nos | 6,500 ₹4,22,500 Lowest |
| .70 | Supply and Providing of AC/DC Horizontal type distribution Junction box with inbuilt 8 nos of 32 amps MCB per unit with 230v ac power system. | 12 | Nos | 4,500 ₹54,000 Lowest |
| .80 | Supply and Providing of MCCB, 4 pole 415 volts, 250 A, with protection system | 3 | Nos | 35,000 ₹1,05,000 Lowest |
| .90 | Supplying and laying 25mm X 5mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. ( Jointing shall be done by over lapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) | 65 | mtr | 900 ₹58,500 Lowest |
| 1.00 | Advanced chemical earth pit of length 5 mtr for groumding of boost charger with backfill compound | 2 | Nos | 17,500 ₹35,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹29,400
Closing Date
30 Dec 2025, 6:00 pmClosed
Gautam Mahanty SO(EnM) Dhori
Gautam Mahanty so (Enm) Dhori Area
Renovation of substation by installation and commissioning of float cum boost charger and transformer monitoring system along with reorganization and upgradation of bays in main substation at 7 by 8 incline Dhori K Colliery Dhori Area.
2025_CCL_349603_1
GM(D)/SO(EnM)/NIT/25-26/21
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Dhori Area
Please refer NIT
2 documents required · 2 mandatory
₹29,400
6 Jan 2026
18 Dec 2025
31 Dec 2025
19 Dec 2025
30 Dec 2025
19 Dec 2025
19 Dec 2025 - 26 Dec 2025
Amount
Supply & providing of remote indication system with alarm for low voltage and in case of failure
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recess steel/PVC conduit as required.(4x6sq.mm)
Supply and providing 110V battery Charger panel of sheet steel siniclure of 2 mm thick dust and vemin proof grey colour input and output terminals shall be provided at the boltom of the cabinet with suitable cable entry Lifting hooks earthing terminal self supported etc. suitable for 150 AH 2 volt x 65 nos lead acid battery.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm
Lead Acid maintenance free battery Voltage - 2V Capacity-150 Ah Charging current-21Amps Internal resistance 0.91 milli ohms and 10 Nos of additional spare battery.
Supply and Providing of AC/DC Horizontal type distribution Junction box with inbuilt 8 nos of 32 amps MCB per unit with 230v ac power system.
Supply and Providing of MCCB, 4 pole 415 volts, 250 A, with protection system
Supplying and laying 25mm X 5mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. ( Jointing shall be done by over lapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Advanced chemical earth pit of length 5 mtr for groumding of boost charger with backfill compound
Complete modification of the control circuit with connection with the existing breaker with necessary ferules lugs and washer etc and complete testing of the breaker control circuit with the modified input power supply.
Supply & laying of 2.5 sq mm copper cable 12 core armoured type multi colour
Laying of pvc insulated cables direct on ground including excavation and re filling
Supervision and contractor profit OH
Total impact of GST for the purpose of CTC
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.22 MB
BOQ_362349.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .