Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹48,380
Closing Date
19 Sept 2026, 6:00 pm4d left
GE (NW) Mankhurd
GE (NW) Mankhurd
SPECIAL REPAIRS REPLACEMENT OF OLD WORNOUT LT PANELS, MCBs, CABLES AT TANAJI, CABS, NOFRA, NSB, TDC UNDER GE (NW) MANKHURD.
2026_MES_785958_1
8610/E8
Open Tender
Civil Works
Item Rate
180 days
Mankhurd
As per tender document
8 documents required · 8 mandatory
₹500
GE (NW) Mankhurd
₹48,380
Yes
19 Sept 2026
22 Aug 2026
21 Sept 2026
22 Aug 2026
19 Sept 2026
5 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installing, testing and commissioning factory made LT Panel board floor Mounted Type (CPRI approved manufacturers as per enlisted make only) cubical type, outdoor type, Confirming to IS 8623 Part 1-1993 fabricated out of 3.15 mm thick CRCA sheet of suitable size to accomodate all accessories/fittings, MCCB and TPN Copper bus bars etc. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders and to be connected with Copper lugs, with seven tank process, including powder coated with two coats of synthetic enameled paint on the surface externally & internally after duly surface preparation including necessary PCC (1 : 3 : 6) type C2 as in foundation. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. A detachable predrilled gland plateof thickness not less than 3 mm thick powder coated shall be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front openable, lockable /openable by key from both sides. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs and PTs and consisting of the following: | 2 | Each Job | - | - |
| 1.1 | a) Electrolyte Copper bus bar of 200 Amp for RYB&N
b) MCCB TPN 125 Amp, 25 KA, 415 Volt - 01 No.
c) MCB SPN 63 Amps, 10 KA, 415 Volts - 13 Nos.
d) MCCB 4P 100 Amps, 16 KA, 415 Volts - 04 Nos.
d) Auto Manual Selector Switch with wiring - 02 No
e) Voltmeter and ammeter- 01 No
f) RYB Indicators - 1 Set
g) Space for fixing of single phase electronic meter with incl new meters - 13 Nos.(spdc porta cabin 1 & 2)
Notes:(ii) The layout drawing of the panel, its fittings/components and the specifications shall be got approved by the contractor from the GE before panel fabrication and shall be of make mentioned in Appendix 'A' or any other manufacturer having CPRI approved certificate. | - | - | - | - |
| 2 | Supply, installing, testing and commissioning factory made LT Panel board floor Mounted Type (CPRI approved manufacturers as per enlisted make only) cubical type, outdoor type, Confirming to IS 8623 Part 1-1993 fabricated out of 3.15 mm thick CRCA sheet of suitable size to accomodate all accessories/fittings, MCCB and TPN Copper bus bars etc. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders and to be connected with Copper lugs, with seven tank process, including powder coated with two coats of synthetic enameled paint on the surface externally & internally after duly surface preparation including necessary PCC (1 : 3 : 6) type C2 as in foundation. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. A detachable predrilled gland plateof thickness not less than 3 mm thick powder coated shall be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front openable, lockable /openable by key from both sides. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs and PTs and consisting of the following: | 1 | Each Job | - | - |
| 2.1 | a) Electrolyte Copper bus bar of 250 Amp for RYB&N
b) MCCB TPN 160 Amp, 25 KA, 415 Volt - 01 No.
c) MCB SPN 63 Amps, 10 KA, 415 Volts - 06 Nos.
d) MCCB 4P 63 Amps, 16 KA, 415 Volts - 06 Nos.
e) MCB 4P 63 Amps, 16 KA, 415 Volts - 02 Nos.
d) Auto Manual Selector Switch with wiring - 02 No
e) Voltmeter and ammeter- 01 No
f) RYB Indicators - 1 Set
spdc p 50
Notes: (ii) The layout drawing of the panel, its fittings/components and the specifications shall be got approved by the contractor from the GE before panel fabrication and shall be of make mentioned in Appendix 'A' or any other manufacturer having CPRI approved certificate. | - | - | - | - |
| 3 | Supply, installing, testing and commissioning factory made LT Panel board floor Mounted Type (CPRI approved manufacturers as per enlisted make only) cubical type, outdoor type, Confirming to IS 8623 Part 1-1993 fabricated out of 3.15 mm thick CRCA sheet of suitable size to accomodate all accessories/fittings, MCCB and TPN Copper bus bars etc. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders and to be connected with Copper lugs, with seven tank process, including powder coated with two coats of synthetic enameled paint on the surface externally & internally after duly surface preparation including necessary PCC (1 : 3 : 6) type C2 as in foundation. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. A detachable predrilled gland plateof thickness not less than 3 mm thick powder coated shall be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front openable, lockable /openable by key from both sides. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs and PTs and consisting of the following: | 1 | Each Job | - | - |
| 3.1 | a) Electrolyte Copper bus bar of 160 Amp for RYB&N
b) MCCB TPN 100 Amp, 25 KA, 415 Volt - 01 No.
c) MCB SPN 63 Amps, 10 KA, 415 Volts - 02 Nos.
d) MCCB 4P 63 Amps, 16 KA, 415 Volts - 06 Nos.
e) MCB 4P 63 Amps, 16 KA, 415 Volts - 06 Nos.
d) Auto Manual Selector Switch with wiring - 02 No
e) Voltmeter and ammeter- 01 No
f) RYB Indicators - 1 Set
Astra vihar
Notes: (ii) The layout drawing of the panel, its fittings/components and the specifications shall be got approved by the contractor from the GE before panel fabrication and shall be of make mentioned in Appendix 'A' or any other manufacturer having CPRI approved certificate. | - | - | - | - |
| 4 | Supply, installing, testing and commissioning factory made LT Panel board floor Mounted Type (CPRI approved manufacturers as per enlisted make only) cubical type, outdoor type, Confirming to IS 8623 Part 1-1993 fabricated out of 3.15 mm thick CRCA sheet of suitable size to accomodate all accessories/fittings, MCCB and TPN Copper bus bars etc. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders and to be connected with Copper lugs, with seven tank process, including powder coated with two coats of synthetic enameled paint on the surface externally & internally after duly surface preparation including necessary PCC (1 : 3 : 6) type C2 as in foundation. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. A detachable predrilled gland plateof thickness not less than 3 mm thick powder coated shall be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front openable, lockable /openable by key from both sides. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs and PTs and consisting of the following: | 1 | Each Job | - | - |
| 4.1 | a) Electrolyte Copper bus bar of 160 Amp for RYB&N
b) MCCB TPN 100 Amp, 25 KA, 415 Volt - 01 No.
c) MCB SPN 63 Amps, 10 KA, 415 Volts - 07 Nos.
d) Auto Manual Selector Switch with wiring - 02 No
e) Voltmeter and ammeter- 01 No
f) RYB Indicators - 1 Set
g) Space for fixing of single phase electronic meter with incl new meters - 06 (NAD P 10)
Notes:(ii) The layout drawing of the panel, its fittings/components and the specifications shall be got approved by the contractor from the GE before panel fabrication and shall be of make mentioned in Appendix 'A' or any other manufacturer having CPRI approved certificate. | - | - | - | - |
| 5 | Supply, installing, testing and commissioning factory made LT Panel board floor Mounted Type (CPRI approved manufacturers as per enlisted make only) cubical type, outdoor type, Confirming to IS 8623 Part 1-1993 fabricated out of 3.15 mm thick CRCA sheet of suitable size to accomodate all accessories/fittings, MCCB and TPN Copper bus bars etc. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders and to be connected with Copper lugs, with seven tank process, including powder coated with two coats of synthetic enameled paint on the surface externally & internally after duly surface preparation including necessary PCC (1 : 3 : 6) type C2 as in foundation. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. A detachable predrilled gland plateof thickness not less than 3 mm thick powder coated shall be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front openable, lockable /openable by key from both sides. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs and PTs and consisting of the following: | 1 | Each Job | - | - |
| 5.1 | a) Electrolyte Copper bus bar of 400 Amp for RYB&N
b) MCCB TP 250 Amp, 25 KA, 415 Volt - 01 No.
c) MCCB TPN 160 Amp, 25 KA, 415 Volt - 04 No.
d) MCB SPN 63 Amps, 10 KA, 415 Volts - 08 Nos.
e) Auto Manual Selector Switch with wiring - 02 No
f) Voltmeter and ammeter- 01 No
g) RYB Indicators - 1 Set
LTL-I
Notes:(ii) The layout drawing of the panel, its fittings/components and the specifications shall be got approved by the contractor from the GE before panel fabrication and shall be of make mentioned in Appendix 'A' or any other manufacturer having CPRI approved certificate. | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
8610General.pdf
Tender Documents • 0.84 MB
BOQ_880739.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .