Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC PLOT NO 106 MIDC SATPUR SATPUR MIDC AREA SATPUR NASHIK MAHARASHTRA 422007 UDYAM MH 23 0018515 | NASHIK | MAHARASHTRA | 422007 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹34.1 L+₹2.8 L (8.96%)Rejected-Finance PI NO 13 S NO 81 82 BEHIND 132 33 KVA MSEB SUBSTATION MIDC AREA AMBAD NASHIK 422 010 | NASHIK | NASHIK | MAHARASHTRA | 422010 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹35.1 L+₹3.8 L (12.3%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹35.7 L+₹4.4 L (14.1%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹37 L+₹5.7 L (18.3%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
22 Feb 2022, 6:00 pmClosed
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH)
AS PER TENDER DOCUMENTS
2022_MES_503625_1
83596/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NASIK
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE NASIK ROAD CAMP
₹80,000
Yes
25 Apr 2022
25 Jan 2022
24 Feb 2022
25 Jan 2022
22 Feb 2022
9 Feb 2022
26 Jan 2022 - 2 Feb 2022
Amount
M & L for taking down the transformer outdoor/indoor/ of any make and any capacity size from its base plinth/pole/substation after disconnecting incomming and outgoing HT/LT connnection, earthing and carefully removing the transformer from pole/ structure/ plinth/substation with arrnagement of mobile crane, transporting the transfomer from substaions to workshop for necessary maintenance/ repair.
M& L for dismentaling & re-assembling carefully electrical connection from HT/LT sides of the transformer keeping them at safe side and taking out the transformer core for carrying out complete overhauling which shall complete of the following :- (a) Opening top cover of the transformer by unscrewing nuts, bolts,washers etc including disconnecting core assy from HT/LT bushing and lifting the same gently and taking out from the shell (container/body) of the transformer. (b) M&L for draining out transformer oil from the above said transformer in the suitable capacity of container/drums and keeping it in safe custody for reuse. (c) M&L for cleaning of the transformer body from inside, removing deposited dirt/sludge/foreign particles etc from the bottom/body of the transformer and drying/heating up the shell from inside before refilling of the transformer oil. (d) Cleaning/washing through core and windings of the transformer by hosing down with clean dry oil conforming IS 335/983,removing deposited dirt sludge/foreign particles from the windings/core and revarnishing of the windings with super varnish including heating/drying/packing complete carefully and throughly inside the heating chamber at suitable temperature to obtained required value of insulation resistance etc all as per IS and directed by Engr-in-charge
Item No 2 Contd.........(e) Lifting and refixing core assy inside the transformer shell gently and carefully,connecting of HT/LT/Neutral connections to the bushings assy,fixing of the tap change over incl tightenting of nut,bolts,washers of the core to reduce humming noise all as directed. (f) Refilling the transformer oil in the shell of transformer only after carrying out filteration by heating upto oil 105 degree certigrade to active reqd dielectric strength and submitting the test result before and after filteration of oil in presence of Engr-In-Charge on proper performa duly signed. (g) Refixing the top cover incl tightenting of nut bolt,washers etc all as directed by Engr-In-Charge. Note:- (i) Any damage to insulator/bushes/windings etc while in the custody of the contractor shall be made good at no extra cost to govt.The serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody (ii) The job taken for repair/overhauling should be complete with in 48 hours from the date of handing over the individual transformer, for that period contractor will make arrnagement for transformer of same capacity for temporary installation at site for smooth functioning without hindrance during the maintenance of the transformer to be carried at no extra cost. (iii) Rewinding of HV/LV coil & re-insulation of winding of HV/LV coil will be paid seperately under relavant item of sch.
Item No 2 Contd.......(iv) Filtration of old T/F oil will be measured under relevant item of this schedule (v) If of old transformer oil found not in reusable condition by Engr-In-Charge after testing , new transformer oil will be filled which will be paid seperately under relavant item of sch. (vi) Any new item incorporated while carrying out repair will be paid seperately under relavant item of sch. (vii) After Repairing transformer testing will be carried out as per IE rules infront of Engr-In-Charge & all testing report will be submitted by contractor duly signed by Engr-In- Charge and Contractor.
Dehydration of tranformer oil, obtained from transformers /voltage stabilizer/OCBs etc. Dielctric strength shall not be less than 40 KV in 2.5 mm gap electrode after dehydration. Dehydration of transformer shall be carried out by using electrically operated dehydration machine and topping up/ replacement of unserviceable transformer oil complete all as directed. Note :- Filteration of transformer oil shall be off loaded position of transformer.
Supply and filling transformer oil of approved quality ISI marked for filling in transformer for topping up/ replacement of transformer oil all as directed by Engr-in-Charge( MAKE: POWER/CASTROL/SERVO) NOTE: I) Dielectric strength of transformer oil not less than 60 KV with two mm gap. II) New Transformer oil shall be filled after filtration only.III) Oil shall be supplied in sealed barrels.
M & L for transporting the repaired transformer from the factory/ workshop to the site with the help of crane and transportation and installing testing and commissioning complete on full load all as specified and directed.
Preparation of surfaces of Transformer /OCB/ Panel Board for applying two coats of synthetic enamelled paint of approved colour by spray painting, writing of MES/SM Nos all as directed by Engr-In-Chage
M & Labour for removing the HV coil from core carefully & re-insulation of HV coil with same class of insulation all as specified & directed by Engr-in-charge .
M & Labour for removing the LV coil from core carefully & re-insulation of LV coil with same class of insulation all as specified & directed by Engr-in-charge .
M&L for rewinding of HV coil with new material of same gauge & same class of material of existing coil with similar class of existing insulation all as specified & directed by Engr-in-charge for transformer.
M&L for rewinding of LV coil with new material of same gauge & same class of material of existing coil with similar class of existing insulation all as specified & directed by Engr-in-charge for transformer.
M & L for replacement of unserviceable/ leaked gasket cork sheet of top cover of the transformer body of HV & LV ,oil rubber bushing irrespective of types and fix new gasket coek sheet etc all as directed.
M&L for replacement of CRGO Core with new material of same gauge & same class of material of existing CRGO Core all as specified & directed by Engr-in-charge for transformer.
M& L for replacement of unserviceable HV pocelain bushing 12 KV with top caps (Brass) complete with at site/workshop etc for the transformer including taking out existing bushings, drain out transformer oil etc and refilling the same.
M& L for replacement of unserviceable HV Bushing terminal rod with washer of brass of suitable dia & length for transformer terminal with BRASS nut and bolts and washers 8 nos complete with oil seal, gaskets, ring washer etc for the transformers including taking out existing bushings complete allas directed at site
M& L for replacement of unserviceable LV Bushing terminal rod with washer of brass of suitable dia & length for transformer terminal with BRASS nut and bolts and washers 8 nos complete with oil seal, gaskets, ring washer etc for the transformers including taking out existing bushings complete allas directed at site
M & L for replacement of tap changer assembly and replacement of worn out nuts and bolts and providing new copper lead for tap changer assembly for transformer of any capacity all as diected by Engr-In- Charge
Supply and fix breather of transformer of various capacities filled with silica gel including taking out of unserviceable silaca gel complete all as directed by Engineer - in - charge.
M & L for replacement of old silica Gel for dehydrating Breather of T/F cleaning the breather internally and externally and filling new silica gel blue colour in dehydrating breather.
M & L for replacement of old oil level indicator glass for transformer of any capacity all as diected by Engr-In- Charge
M & L for replacement of old explosive vent Dia for transformer of any capacity all as diected by Engr-In- Charge
M & L for replacement of old Brizzing Rod for transformer of any capacity all as diected by Engr-In- Charge
M & L for replacement of old Cotton tape for transformer of any capacity all as directed by Engr-In- Charge
M & L for replacement of old webbling tape for transformer of any capacity all as diected by Engr-In- Charge
M & L for replacement of Copper bus bar for transformer of any capacity all as diected by Engr-In- Charge
M & L for maintainance of 11 kv VCB's of Make M/s Vibha Corporation of different capacities ( ABB) 3 Nos viz MAIN INCOMMER, NRC FEEDER & MAP FEEDER and 11 KV PT Trolly maintenance of ratio 11000/Root3/110 root 3, HSV 12 KV comprising the following:-(a) Calebration & Testing of over current & Earth fault relay by primary & secondary ejection methods.(b) Insulating of VCB track, greasing of wheel and checking for few movement for closing and withdrawing of VCB track. (c) Cleaning/wiping the insulating components, primary & secondary circuits i.e green spots, carbon deposite completely.(d) Testing of primary & secondary circuit with 1000 Volts megger for insulation resistance.(e) Flash testing of secondary circuit at 2000Volts for one minute after disconnecting the instruments from the panel.(f) Testing, sychronisation/calibration of meters and relays.(g) Cleaning/wiping of busbar, phase barriers, Busbar support and sleeves.(h) Writing of MES/SM Nos on Panel all as directed by Engr-In-ChageNote :- Complete Job for 2 Nos VCB as above described will be done only by M/s Vibha Corporation Service Department qualified engineer and staff only . No other agency will be entertained. Complete Testing will be carried out in presence of Engr-In-Charge at full satisfication level and testing report will be submitted and duly signed by Engr-In-Charge and Contractor
Labour for disconnecting carefully electrical connection from 33 KV HT sides of the potential transformer outdoor type of capacity 33 KV mounted on steel structure at 33 KV substation, keeping the disconnected connections at safe side and taking out the potential transformer having following details to carrying out which shall complete of the following ratio :-(i) Primary side (KV) = 33/1.732 (ii) Secondary side (V) = 110/1.732 complete all as per Engr-in-Charge.
Material, repair and labour for lifting , transporting handling the 33 KV potential transformer to workshop and opening top cover of the potential transformer by dismantling the slud, unscrewing nuts, bolts, washers etc including disconnecting core assy from HT bushing and lifting the same gently and taking out from the shell (container/body) of the potential transformer complete all as per directed by Engr-in-Charge.
Material, Repairs and labour for draining out burnt oil from the 33 KV potential transformer.
Material, repair and labour for cleaning of the 33 KV potential transformer body from inside, removing deposited dirt/sludge/foreign particles etc from the bottom/body of the potential transformer and drying/heating up the shell from inside before refilling the new transformer oil of ISI grade complete all as per directed by Engr-in-Charge.
Material, repair and labour for copper winding of coil with same gauge , same no of turns and same material with similar class of existing insulation as per manufacturers specifications and gently refixing the coil in body of 33 KV potential transformer /Current Transformer.
Material, supply and refilling oil of approved quality ISI marked for filling 33 KV potential transformer/Current Transformer.
Material, repair and labour for the top cover incl replacement of cork sheet,/gasket, tightening of nut bolt, washers etc for 33 KV potential transformer.
Supply and labour for new HT pocelain bushing with studs complete with oil seal, gaskets, ring washer at workshop for 33 KV potential transformer.
Repair and labour for Lifting/shifting to the place from where removed and re-installing the potential transformer including connecting HT/Earthing connecting including Testing and filling and commissioning of 33 KV PT etc.
Repair and Labour for disconnecting carefully electrical connection from 33 KV HT sides of the current transformer outdoor type of capacity 33 KV mounted on steel structure at 33 KV substation, keeping the disconnected connections at safe side and taking out the current transformer .
Labour for lifting , transporting handling the 33 KV Current transformer to workshop and opening top cover of the current transformer by dismantling the slud, unscrewing nuts, bolts, washers etc including disconnecting core assy from HT bushing and lifting the same gently and taking out from the shell (container/body) of the current transformer complete all as per directed by Engr-in-Charge.
Repairs and labour for draining out burnt oil from the 33 KV current transformer.
Repair and labour for cleaning of the 33 KV current transformer body from inside, removing deposited dirt/sludge/foreign particles etc from the bottom/body of the current transformer and drying/heating up the shell from inside before refilling the new transformer oil of ISI grade complete all as per directed by Engr-in-Charge.
Repair and labour for the top cover incl replacement of cork sheet,/gasket, tightening of nut bolt, washers etc for 33 KV current transformer.
Supply and labour for new HT pocelain bushing with studs complete with oil seal, gaskets, ring washer at workshop for 33 KV Current transformer.
Repair and labour for Lifting/shifting to the place from where removed and re-installing the current transformer including connecting HT/Earthing connecting including Testing and filling and commissioning of 33 KV CT etc.
M&L for Testing and commissioning of Current Transformer & calebration of 33 KV HT control Relay Panel for over current & Earth fault protection by primary & secondary ejection methods & submitting test report duly signed by Engr-in-Charge.
M&L for disconnecting carefully electrical connection from 11 KV HT sides of the CURRENT transformer indoor type of capacity 11 KV mounted on VCB at 11 KV sub stn AOP feeder , keeping the disconnected connections at safe side & supply and fix in repairs 11KV Indoor Current Transformer oil immersed type Epoxy Resin Cast having following specification :-(a) 2705/BS 3938, ratio : 50/5/5 Amp, S.T.C : 18.4 kA for 0.5 Sec burden class core 1-15 VA /1.0 class , core 2-15 VA/5P10, HSV-12 KV as per IE Rules (b) Frequency 50 Hz Make : Crompton Greaves/Equivalent.
M&L for Heat shrinkable 33 KV (E) XLPE Indoor termination ( 3 core ) , HT underground cable of size 3 core 240 sqmm, 33000 volts all as specified and directed by Engineer-in-Charge.
M & L for general maintainance of 33kv HT Relay panel incuding out door unit of VCB of different capacities and comprising the following:-(a) Calebration & Testing of over current & Earth fault relay by primary & secondary ejection methods.(b) Insulating of VCB track, greasing of wheel and checking for few movement for closing and withdrawing of VCB track. (c) Cleaning/wiping the insulating components, primary & secondary circuits i.e green spots, carbon deposite completely.(d) Testing of primary & secondary circuit with 1000 Volts megger for insulation resistance.(e) Flash testing of secondary circuit at 2000Volts for one minute after disconnecting the instruments from the panel.(f) Testing, sychronisation/calibration of meters and relays.(g) Cleaning/wiping of busbar, phase barriers, Busbar support and sleeves.
M & L for general maintainance of 11 kv VCB's of make Bicco lawrence different capacities and comprising the following:-(a) Calebration & Testing of over current & Earth fault relay by primary & secondary ejection methods.(b) Insulating of VCB track, greasing of wheel and checking for few movement for closing and withdrawing of VCB track.(c) Cleaning/wiping the insulating components, primary & secondary circuits i.e green spots, carbon deposite completely (d) Testing of primary & secondary circuit with 1000 Volts megger for insulation resistance.(e) Flash testing of secondary circuit at 2000Volts for one minute after disconnecting the instruments from the panel.(f) Testing, sychronisation/calibration of meters and relays.(g) Cleaning/wiping of busbar, phase barriers, Busbar support and sleeves.(h) Scraping & Painting the VCB with approved quality of grey paint & writing of MES/SM Nos allas directed by Engr-In-Chage
Supply , laying and testing XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cable (Heavy duty ) with aluminium conductor 11000 volts grade lay in trenches , ducts , along pole, along transformer cross sectional area 3 core 240 sqmm complete all as specified and directed.
Supply , laying and testing XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cable (Heavy duty ) with aluminium conductor 11000 volts grade lay in trenches , ducts , along pole, along transformer cross sectional area 3 core 95 sqmm complete all as specified and directed.
M&L for synthetic insulating mat having size 2x1x25mm all as specified and directed.
EXCAVATION BY TENCHLESS TECH - Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia. Suitable for 0.4 mpa working pressure.
Dismantling of U/S insulator of any size and type complete from its position and removing all as directed by Engr-in-Charge.
Re-fixing of old HT disc insulator obtained from item No. 51 above.
Re-fixing of old HT Pin insulator obtained from item No. 51 above.
S&F loop type insulator , vitreous porcelain , 140mm clearance of hole 25.5 mm , white, brown or green all as specified and directed by engineer-in-Charge.
S & F HT disc insulator porcelain vitreous 145mm height, 255mm dia, ball and socket type. White / brown with M.S. galvanized iron fitting suitable for working pressure 11KV all as specified and directed by Engr-in-Charge.
Dismantling of U/S stay assembly carefully including stay wire necessary excavation and earth work in any type of soil, demolition of PCC of any type and removing from site all as directed.
Stay assembly complete with accessories and stay rod 16mm dia and 180 cm long, including ms galvanized stay plate 300 mm x300 mmx6mm and galvanized thimble complete all as specified and shown in electrical plate No 1 Note-(loop type insulator, stays clamps, excavation and earth work and concrete measured separately)
All as per Item No 57 but stay Rod 20 mm dia
Dismantling of U/S existing cross arms by means made from channels, angles, U/S GI clamps, nuts, bolts etc. from OH line and removing complete.
S & F Cross arms ,bracings,supports,clamps and back plate fabricated from structural steel sections including nuts ,bolts, in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide .
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 240 sqmm all as specified and directed by Engr-in-Charge
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
Steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 100 mm dia along with necessary calmp nut bolt etc complete all as specified and directed Make - TATA / JINDAL /SWASTIK
Taking down old U/S MCB TPN of any make & supply and fix MCB TPN 415 Volts, 'C' series, breaking capacity 10 kA of rating 63 Amps including necessary cable lugs/glands required at site complete all as directed by Engr-in-Charge .Make: L&T cat part No BB30630C or equivalant to Legrand /ABB /Standard Note :- The item is operated as per daily based job card and complaint slip from department.
Dismantling carefully the existing U/S LT/HT Overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor and removing complete all as directed by Engr-in-Charge.
Supply and stringing ACSR conductor for over head line securing on pole complete including binding wire ,jointing sleeves aluminium tap and PG clamp etc of any size all as specified and as directed.
Stringing only old dismantled ACSR conductor for over head line securing on pole complete including binding wire , etc of any size all as specified and as directed.
Dismantling of U/S LT insulator of any size and type complete from its position and removing all as directed by Engr-in-Charge.
Re-fixing of old LT pin insulator obtained from item No 69 above.
Re-fixing of old LT shakel insulator obtained from item No. 69 above
S & F pin type insulator 100mm height and 65mm dia for 1100 Volts grade, porcelain White, Brown or Green including one GI spindle, two GI washer, one GI nut all as specified and directed by Engr-in-charge.
S & F LT shackle type insulator 90mm dia 75mm height, including GI strip of Size 31 x 3 mm washers, 12mm dia, Insulators nuts, bolts suitable for 1100 volts grade.
Taking down old jumper connection of 4 pole structure from line/AB/DO & re-fixing complete with new conductor , including line tap, lugs, & PVC alkadin/pipe sleeve all as specified and directed by engr-in-Charge. ( ACSR conductor will be measure & paid separately )
Taking down old jumper connection of 2 pole structure from line/AB/DO & re-fixing complete with new conductor , including line tap, lugs, & PVC alkadin/pipe sleeve all as specified and directed by engr-in-Charge. ( ACSR conductor will be measure & paid separately )
Taking down old jumper connection of disc cut point from line and re-fixing complete with new conductor , including line tap, lugs, & PVC alkadin/pipe sleeve all as specified and directed by engr-in-Charge. ( ACSR conductor will be measure & paid separately )
Taking down of faulty LT underground cable of size upto 3.5 x 25 sqmm from trenches/pole/wall etc for detecting fault including repair and jointing at site including relaying at the same location complete : Note : Excavation/Earth work and cable jointing & jointing kit shall be measured and paid for separately under relevant item of schedule .
Taking down of faulty LT underground cable of size above 3.5 x 25 sqmm upto 150 sqmm from trenches/pole/wall etc for detecting fault including repair and jointing at site including relaying at the same location complete : Note : Excavation/Earth work and cable jointing & jointing kit shall be measured and paid for separately under relevant item of schedule .
Supply and joint cable jointing kit straight through joint epoxy type of size 10 sqmm 4 core to 16 sqmm 4 core all as specified and directed. Make : Denson, Raycom
Supply and joint cable jointing kit straight through joint epoxy type of size 25 sqmm 3.5 core to 50 sqmm 3.5 core all as specified and directed. Make : Denson, Raycom
Supply and joint cable jointing kit straight through joint epoxy type of size 70/95 sqmm 3.5 all as specified and directed. Make : Denson, Raycom
Supply and joint cable jointing kit straight through joint epoxy type of size 120 sqmm 3.5 to 150 sqmm 3.5 core all as specified and directed. Make : Denson, Raycom
Servicing/Greasing of old existing Air break gang operated switch with complete overhauling/greasing including replacement of broken handle/ rod as specified and directed by Engr-in-Charge.
S & F Switch air break gang operated triple pole mechanically operated mounted on insulator and steel frame out door type suitable for vertical installation single brake provided with locking arrangement, consisting of MS channel ,HT post type insulator ,copper alloy high pressure assembly ,operating rod of GI pipe medium grade confirming to IS-1818 of 1972 ,suitable for 11000 volt ,400 Amps incl dismantling of old one all as specified.Make:- Jaipuriya Bros
S&F new radium sticker Radium paint / sticker of different colour 80 cm above coping of pole, i.e. alernatively with sky blue / red & white radium sticker (10 cm - 04 sky blue / red strip and 10 cm - 04 white strip) complete circumference of any type any shape pole and cement base paint on coping portion, marking of pole nos with radium yellow / black paint /steeker in round shape 15 cm dia with letter writing 5 cm height 5 mm width etc all as specified and directed.
Dismantling of existing U/S LT pole of any size & type from its position carefully and removing from the site and necessary excavation and earth work in any soil/strata, demoltion of concrete, disconnection of conductor fom pole etc. complete all as directed.
Supply, install erect in trench vertical position steel tubular seweaged welded poles complete with MS base plate of 6mm thick of size 450mm x 450mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 11 mtr long 410 SP-31 including drilling of holes of required size and nos for fixing of cross arms bracing support/ taking out of cables etc, with inbuilt junction box for 3 phase 4 wire AC supply and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete complete all as specified and as directed by Engineer -in-charge.
Supply, install erect in trench vertical position steel tubular seweaged welded poles complete with MS base plate of 6mm thick of size 450mm x 450mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 9 mtr long 410 SP-31 including drilling of holes of required size and nos for fixing of cross arms bracing support/ taking out of cables etc, with inbuilt junction box for 3 phase 4 wire AC supply and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete complete all as specified and as directed by Engineer -in-charge.
Taking down unservisable U/G cable from trenches, wall, floor etc above 70 upto 120 sqmm
S& F XLPE insulated armoured and pvc sheated heavy duty electric cable size of following sizes aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendment laid in tranches passing through pipes /ducts including testing complete note- rate is inclusive of cable gland & cable lugs
(i) 3.5 core 70 sqmm
(ii) 3.5 core 95 sqmm
(iii) 3.5 core 120 sqmm
Excavation in trenches for laying of cables ,poles and stay in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr deep and getting out.
Material and labour for Doubled walled Corrugated DWC HDPE pipe of outer dia 90mm and inner dia 78mm including 80 degree bends with coupler and rubber ring laid in trenches of size 90mm dia suitable for cable protection complete all as specified and directed.
Returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc. 25cm all as specified and directed by Engr-in-Charge.
Removing excavated soil n.exc 50 mtr and depositing where directed at a level n. exe 1.5mtr above the starting point all as specified and directed.
Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for coaping of pole as specified by Engr-in-charge.
Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation of poles etc all as specified.
Steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 100 mm dia along with necessary calmp nut bolt etc complete all as specified and directed Make - ITC / JINDAL /ZENITH/TATA/ PRAKASH SURYA /SWASTIK
M&L Earthing with 600X600X6 mm thick , galvanised steel earth plate electrode buried vertically in ground (Earth pit not less than 2.25 meter deep below normal ground level ) with top edge of plate vertically at a depth ,not less than 1.5 m below ground level connected to and including GI strip of size 32X6 mm by means of bolts,nuts,check nuts, And washer of galvanised steel, Gi shrip to be provide upto the extent of 7.5 m GI strip to be duly connected to metalic bodies of HT/LT equipment with provision of mixture of charcoal dust & common salt packed all ground the earth plate upto MS funnel with wire mesh provided inside concrete earth pit for watering arrangement including earth work of any type of strata ,complete all as shown on electrical plate no.3 of SSR Part I (2020) and testing on completion.
M&L Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mm dia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work of any type of strata complete all as shown in electrical plate No-3 of SSR-2020 (part-I)
Material and labour for earthing complete with copper earth plate electrode size 300 x 300 x 3.0 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including copper earth strip 20 x 3.0 mm earth lead by means of bolts, nuts, check nuts and washers of copper including GI pipe light grade of size of 40 mm dia for protection and GI pipe light grade 20 mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work of any type of strata all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
SUPPLY & FIX PVC junction box of size inside dimenssion 250x200x105 mm complete with industrial connector, and suitable size of MCB including clamp made out of MS flat iron 30x5 mm , connection from junction box to street light fitting as specified & directed Make:Sintex cat no : GS JB 2520
M&L for scrapping the existing deterioted old alumininum paint by iron brushing and painting of steel tubular poles of (9.0 mtr length) with one coat of metal primer and two coat of aluminium paint over exposed portion of pole above PCC coping including cross arms, angles, nut, bolts, clamps and S&F new radium sticker Radium paint / sticker of different colour 80 cm above coping of pole, i.e. alernatively with sky blue / red & white radium sticker (10 cm - 04 sky blue / red strip and 10 cm - 04 white strip) complete circumference of any type any shape pole and cement base paint on coping portion, marking of pole nos with radium yello / black paint /steekar in round shape 15 cm dia with letter writing 5 cm height 5 mm width etc. complete all as specified and directed at site.complete all as specified and directed at site by Engineer-in-Charge
M&L for scrapping the existing deterioted old alumininum paint by iron brushing and painting of steel tubular poles of (11.0 mtr length- Two pole structure) with one coat of metal primer and two coat of aluminium paint over exposed portion of pole above PCC coping including cross arms, angles, nut, bolts, clamps and S&F new radium sticker Radium paint / sticker of different colour 80 cm above coping of pole, i.e. alernatively with sky blue / red & white radium sticker (10 cm - 04 sky blue / red strip and 10 cm - 04 white strip) complete circumference of any type any shape pole and cement base paint on coping portion, marking of pole nos with radium yello / black paint /steekar in round shape 15 cm dia with letter writing 5 cm height 5 mm width etc. complete all as specified and directed at site.complete all as specified and directed at site by Engineer-in-Charge
M&L for scrapping the existing deterioted old alumininum paint by iron brushing and painting of steel tubular poles of (11.0 mtr length- four pole structure) with one coat of metal primer and two coat of aluminium paint over exposed portion of pole above PCC coping including cross arms, angles, nut, bolts, clamps and S&F new radium sticker Radium paint / sticker of different colour 80 cm above coping of pole, i.e. alernatively with sky blue / red & white radium sticker (10 cm - 04 sky blue / red strip and 10 cm - 04 white strip) complete circumference of any type any shape pole and cement base paint on coping portion, marking of pole nos with radium yello / black paint /steekar in round shape 15 cm dia with letter writing 5 cm height 5 mm width etc. complete all as specified and directed at site.complete all as specified and directed at site by Engineer-in-Charge
M&L for danger notice plate/board of 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bone in signal red coulr and fixed with MS Clamps, bolts and nuts of approved for HT 250 x 200mm size etc complete all as specified and directed.
M&L for danger notice plate/board of 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bone in signal red coulr and fixed with MS Clamps, bolts and nuts of approved for LT 200 x 150mm size etc complete all as specified and directed.
M&L for plate/board of 3 mm thick and 1.5 feet x 1 ft size mild steel sheet vitreous enamelled white with letters approx 20 words regarding incoming/outgoing supply with figures and conventional skull and bone in signal and fixed with MS Clamps, bolts and nuts of approved for LT 200 x 150mm size etc complete all as specified and directed.
M&L Disconnecting the defective Servo voltage stabilizer from the main circuit, removing all incoming/outgoing control cable, earthing complete, tking out the stabilizer from the Sub station room , loading/unloading the stabilizer with mobile crane into the truck at site and at workshop , transporting to and from work shop to shop for and after repair work as under all as specified and directed . ( Note : Repair work shall be measured and paid separately under separate item of sch )
Dismantling the voltage stabilizer complete with top cover, top gasket, coils, core, brush holder assembly carbon spring, carbon brush , main transformers coil and rediator assembly complete with servicing the nut , bolt, washers etc all as specified and directed.
Cleaning/scraping of carbon cleaning/carbon disposition material manual/mechanically to the body of the coils, bursh holder assembly , carbon spring, carbon brush and rediator core complete with wire gauge/emery paper complete all as specified and directed.
M&L for replacement of defective brush holder 08 nos with suitable existing size/grading all as specified and directed by Engr-in-Charge.
M&L for replacement of defective carbon brush with existing grading all as specified and directed by engr-in-Charge.
M&L for replacement of unserviceable internal Bakelite brush with base plate for dimmerstate as per existing dimensions and all as specified and directed by engr-in-Charge.
M&L for Re-winding and re-insulation of the main copper coil ( stabilizer dimmerstate coil -03 nos) with new insulating super enamelled 'H' class insulation copper winding wire of existing gauge and weight all as specified and directed.
M&L for Annealing/milling of stabilizer dimmerstate coil after complete re-winding and insulation of 300 KVA voltage stabilizer as per orioginal standard as directed.
M&L for replacement of burnt/short caked processing/controlling electric processing cord complete all as specified and directed.
Re-assembling the different components of the unit , core, dimmerstat coil, carbon brush assembly, brush holders, controlling cables, controlling processing cord, installation, testing commissioning and testing on full load at site to the entire satisfaction of Engineer-in-Charge.
Supply and filling fresh insulating oil for cooling the stabilizers coil and other concealed equipment after filteration and attaining BDV upto 40 KV all as specified and directed.
Material and labour for painting of LT pannel board/ LT feeder piller box, indoor/out door type any size/capacitywith smoke gray colour synthetic enamel paint one coat over the existing paint after cleaning and removing the dust and durt and cleaning with sand paper complete including writting letters 100 mm height with white synthetic enamelled paint complete all as specified and directed at site.
S & F MCCB 4 pole in LT Panel thermal magnetic setting of current amp 400A , breaking capacity 25kA, of make legrand cat no :- 420057/Standard -ISLGHF0160 complete with lugs ,spreader link, gland to cable complete all as specified and directed.
S & F MCCB 4 pole in LT Panel thermal magnetic setting of current amp 250 A , breaking capacity 25kA, of make legrand cat no :- 420057/Standard -ISLGHF0160 complete with lugs ,spreader link, gland to cable complete all as specified and directed.
S & F MCCB TPN in LT Panel thermal magnetic setting of current amp 160A , breaking capacity 25kA, of make legrand cat no :- 420057/Standard -ISLGHF0160 complete with lugs ,spreader link, gland to cable complete all as specified and directed.
S & F MCCB TP in LT Panel thermal magnetic setting of current amp 125A , breaking capacity 16kA, of make legrand cat no :- 420006/Standard-ISLGNT0125 complete with lugs ,spreader link, gland to cable complete all as specified and directed by Engr-In-Charge.
S & F MCCB TP in LT Panel thermal magnetic setting of current amp 100A , breaking capacity 16kA, of make legrand cat no :- 420005 /Standrad ISLGNT0100 complete with lugs ,spreader link, gland to cable complete all as specified and directed directed by Engr-In-Charge.
S & F MCB SPN in LT Panel of current amp 63A , breaking capacity 10kA,ISI marked as per IS/IECC 60898-1 2002 with integrated label holder, sliding bottom clamp, Inproved air channels, color codedOn/off indication on dolly, biconnect lower terminals IP 20 proteced terminals, sliding shutters C Curve , 240 V of make legrand cat no :- 408620 complete with lugs , gland to cable complete all as specified and directed by Engr-In-Charge.
S & F MCB SPN in LT Panel of current amp 40A , breaking capacity 10kA,ISI marked as per IS/IECC 60898-1 2002 with integrated label holder, sliding bottom clamp, Inproved air channels, color codedOn/off indication on dolly, biconnect lower terminals IP 20 proteced terminals, sliding shutters C Curve , 240 V of make legrand cat no :- 408618 complete with lugs , gland to cable complete all as specified and directed by Engr-In-Charge.
Supply and fix galvanized earth strip 32 mm x 6 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 meter interval all as specified and as directed.
Supply and fix alluminium earth strip 25 mm x 4 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 meter interval on any type of bldg/hanger all as specified and as directed
Supply & fix single pointed air termination rod 12 mm dia & 300 mm long with removing of old one all as specified and directed.
Supply & fix test point terminal block made out of gunmetal/brass/bronze size 75x75mmx25mm drill & screw incl 3 nos ,8mm dia 25 mm long hex screw including taking down old u/s test point
Taking down old unserviceable metal box and supply and fixing MS enclosure made out of CRCA sheet 3.00mm thick of size 450mm x 450mm x 250mm depth with aluminium bus bar mounted on epoxy insulators, fixing arrangement with suitable MS Clamps.
Taking down of street light bracket including clamps of any type/any size from pole/wall including necessary nuts & bolts all as specified and directed.
M&L for fabrication and installation of GI pipe bracket made of medium frade tubing of size 40mm dia duly bended by hot forging after filling of sand, length 1.20 mtr including two pairs of MS flat strip clamps 30 x 5mm with GI bolts, nuts and washers complete all as specified and directed.
Dismantling and taking down by disconnecting electric connection from existing serviceable /unserviceable /partly unserviceable street/security/flood light fittings or any other light fitting of any type/any wall, fitting and fixture etc and depositing to MES store yard or serviceable light fitting will be reuse in other loction and making good to the disturbed surfaces etc complete all as specified and directed at site.
Fixing only in repair and connecting after testing only serviceable street / security / flood light fittings of any type / any watt, fitting and fixtures etc. other location including wiring from junction box to the fitting. (street / security / flood light fittings will be reused obtained / removed against item no 01 herein above), complete all as specified and directed at site.
Supply and fix in repairs 80 W LED flood light fitting, pressure die cast with IP 66 protection, efficient high output emmitter LED for better distribusion, surge protection device 5KV upto rated power 150 W , complete all as specified and directed.(Make - Crompton cat part no LFL-80-CDL/60-M or eqvt. make of Havells / Philips)
Supply and fix in repairs 60 W LED Street light fitting, pressure die cast with IP 66 protection, efficient high output emmitter LED for better distribusion, surge protection device 5KV upto rated power 150 W , complete all as specified and directed.(Make - Crompton cat part no LSTP-60-CDL or eqvt. make of Havells / Philips)
Supply & fix PVC insulated 3 core 1.5 sqmm multistranded Copper conductor on pole for security light from junction box to street light fititng including making necessaey hole on surface of pole for insertion of 3 core pvc cable inside the pole upto street light fitting as specified & directed. etc complete all as specified and directed. Make:- Polycab/Havells/Gloster
NARMARAJ ELECTRICALS
SHRI SWAPNAYOG ENTERPRISES
E M CONSTROL SYSTEM
DURGAI ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .