Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC 00 RL QR NO 388 B KALIBARI COLONY ALIPURDUAR JN JALPAIGURI WEST BENGAL 736123 | ALIPURDUAR | WEST BENGAL | 736123 | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.5 L+₹57,569.23 (9.73%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹6 L
EMD Value
₹6,000
Closing Date
27 Aug 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EDC, BDN
BUDAUN
95/EDCB/2023-24
2024_MVVNL_921591_3
95/EDCB/2023-24
Open Tender
Electrical Works
Item Rate
90 days
BUDAUN
AS PER TENDER DOCUMENT
3 documents required · 3 mandatory
₹1,180
A/c No. 1243002100806171, IFSC Code - PUNB0124300
₹6,000
9 Jan 2025
25 May 2024
28 Aug 2024
25 May 2024
27 Aug 2024
25 May 2024
25 May 2024 - 27 Aug 2024
Amount
The work of safe carriage of the following material from store center Nawada to work site under the jurisdiction of EDD-IV (Ujhani), Budaun Approx. distance upto 0-60 Km. Including safe loading and unloading.
11/0.4 KV 25 KVA T/F
11/0.4 KV 63 KVA T/F
11/0.4 KV 100 KVA T/F
11/0.4 KV 250 KVA T/F
PCC Pole Support 8.5 Mtr. Long
ST Pole Support 11 Mtr. Long
11 KV MS T-Off Channel
Top Channel (125x65x2240 mm)
S/S Base Angle (75x75x6x2028mm) bolt & Nut
11 KV Disc Insulator Composite 45 KN (T&C Type)
11 KV Pin Insulator Composite
11 KV X-Arm V Type
11 KV TPMO
ACSR Weasal Conductor
L.T. LEAD LT XLPE Cable 3.5x70 Sqmm
L.T. LEAD LT XLPE Cable 3.5x150 Sqmm
Stay Complete
Earthing Complete
ABC Cable (3x95+1x35+1x16) sqmm
ABC Cable (3x50+1x35+1x16) sqmm
ABC Cable (3x120+1x35+1x16) sqmm
3 Phase Distribution Box
L.T. Cable 1x400 Sqmm
11 KV Fuse Set
Dropper Chanel
Construction of 250 KVA T/F plinth 1.5x1.5x2 Mtr. for mounting T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect as per RESSPO Norms.
Cage fencing of 250 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) by strenghtening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation.
Pipe Earthing of Transformer (By boring of 4 inch diameter 20 m deep, 40 mm diameter A Class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5m length is inserted at the bottom, Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work contractor will provide all material, manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE)
Construction/Erection of Double Pole (except pole) Suitable for following T/Fs including fitting of all accessories (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per RESSPO Norms).
11/0.4 KV 25 KVA T/F
11/0.4 KV 63 KVA T/F
11/0.4 KV 100 KVA T/F
Mounting of following T/F,s as per norms complete in all respect -
11/0.4 KV 25 KVA T/F
11/0.4 KV 63 KVA T/F
11/0.4 KV 100 KVA T/F
11/0.4 KV 250 KVA T/F
Erection of Single PCC 8.5 Mtr. Long/ ST Pole Support 11 Mtr. Long in H.T/L.T lines including fitting of all accessories as per RESSPO Norms (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per RESSPO Norms).
Grouting of PCC 8.5 Mtr. Long/ST Pole Support 11 Mtr. Long with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/C.C. & sand Required as per RESSPO Norms. (All Grouting material shall be provided by the contractor).
Laying, Stringing, Sagging & Jumpring of Following Conductor complete in all respect as per RESSPO Norms.
ACSR Weasal Conductor
L.T. LEAD LT XLPE Cable 3.5x70 Sqmm
L.T. LEAD LT XLPE Cable 3.5x150 Sqmm
ABC Cable (3x95+1x35+1x16) sqmm
ABC Cable (3x50+1x35+1x16) sqmm
ABC Cable (3x120+1x35+1x16) sqmm
L.T. Cable 1x400 Sqmm
Erection/Fixing of stay set with stay wire and clamp as per RESSPO norms including binding. climbing, clamping, tightening and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and C.C. and sand etc. as per RESSPO norms. All the grouting material shall be provided by the contractor.
The work of driving the earthing electrode and making connections with GI wire.
Installation, Fixing & Fabrication of 11 KV fuse set (Including Cost of Fuse set) Installed on midway of 11 KV double pole structure with mention material specification (MS Channel 100x50x2028mm), Iron Strip (50x5x305 mm) & Fuse wire of required capacity etc. shall be provided by the contractor for execution of work as per RESSPO Norms.
Fixing of danger board on each location and G.I. barbed wire including proper clamping as per RESSPO Norms. (Danger Board shall be provided by the contractor as per details given in S.No. 14 as per RESSPO Norms).
Erection & Fixing of 11 KV TPMO set with handle on existing double pole including providing of clamps and nut & Bolts and jumpering of both side by TPMO complete in all respect.
Errection and commissioning of 3 Phase Distribution Box on the LT Poles (All the material required shall be arranged by the contractor for errection and commissioning of distribution boxes except distribution box).
Erraction/Fixing of 11 KV Fuse Set complete in all respect as per RESSPO Norms.
The following Decentralized material shall be provided by the contractor for execution of work as per RESPO Norms (the material shall be purchased from approved vendor of Discom).
Holding Clamps for S/s with Bolt & Nuts
Holding Clamps for LT T-OFF
11 KV F Clamp with Nut & Bolt
PG Clamp
Stone Pad
Danger Board
Barbed Wire
Piercing Connector
LT Shackle Insulator
N&B for Shackle Insulator
LT Clamps with N&B for Shackle Insulator
Al. Lugs for 150 KV Sqmm Cable
Al. Lugs for 240 KV Sqmm Cable
LUGS OF Suitable Size (70 sqmm)
Stay Insulator
DURGESH CHANDEL
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .