| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | ₹12.4 L Quoted ₹12.6 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹14.3 L+₹1.7 L (13.6%)Rejected-AOC | ₹14.3 L+₹1.7 L (13.6%) | L2 | Rejected-AOC Not Being Lowest |
| 3 | Rejected-Technical 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | - | - | Rejected-Technical Rejected due to not ful fill the eligibility criteria |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
26 Aug 2020, 6:00 pmClosed
GE 970 EWS
GE 970 EWS C/O 56 APO
As described in Bill of Quantities
2020_MES_365543_1
GE 970 EWS- /2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MANASBAL
Class E category b(i) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹30,000
Yes
5 Oct 2020
31 Jul 2020
28 Aug 2020
31 Jul 2020
26 Aug 2020
14 Aug 2020
Amount
S&F in repair of electronic control and logical cards of convetional type Constant current regulator CCR panel thyristor controlled 230V, single phase, indoor type natural air cooled 5 position current steps 2.8A, 3.1A, 4.1A, 5.2A, & 6.6A rating 4 KW and output 606VAC including calibratoin for sensitivity on site complete all as specified and directed by Engr-in-Charge. Make : NASU system Mumbai or its equivalent as specified and directed by GE.
S&F in repair of electronic control and logical cards of convetional type Constant current regulator CCR panel thyristor controlled 415V, Two phase, indoor type natural air cooled 5 position current steps 2.8A, 3.1A, 4.1A, 5.2A, & 6.6A rating 7.5 KW and output 1137VAC including calibratoin for sensitivity on site complete all as specified and directed by Engr-in-Charge. Make : NASU system Mumbai or its equivalent as specified and directed by GE.
S&F in repair of electronic control and logical cards of convetional type Constant current regulator CCR panel thyristor controlled 415V, Two phase, indoor type natural air cooled 5 position current steps 2.8A, 3.1A, 4.1A, 5.2A, & 6.6A rating 20 KW including calibratoin for sensitivity on site complete all as specified and directed by Engr-in-Charge. Make : NASU system Mumbai or its equivalent as specified and directed by GE.
Supply, laying, commissioning and testing in replacement of 6Sqmm copper control cable, solid annealed plain copper conductor PVC inner sheathed, XLPE power cable of single core 5KV grade confirming to IS upto date as required for runway lighting from RCD control panel or CCR panel complete all as specified and directed. Make : RAJLASON/Laab/Jindal.
Supply, laying, commissioning and testing in replacement of 16Sqmm copper control cable, solid annealed plain copper conductor PVC inner sheathed, XLPE power cable of single core 5KV grade confirming to IS upto date as required for runway lighting from RCD control panel or CCR panel complete all as specified and directed. Make : RAJLASON/Laab/Jindal.
Supply, installation, commissioning in replacement of bi-directional elevated type high intensity runway edge light fitting suitable for use with 200W, 6.6Amp AC constant current series system with bi-pin halogen Lamp complete with all accessories such as CI base plate, breakable coupling, mounting assembly, gasket, lamp Holder,lenses, 2 pin secondary lead plug 2.5 Sqmm copper, stainless steel bolt, spring suitable for connection of adequate length etc confirming to ICAO Anns 14, complete all as specified and directed by Engr-in-Charge. Make : AMA/THORN/SAFEGATE/VARDHMAN.
Supply, installation, commissioning in replacement of omni-directional elevated type medium intesity taxiway light fitting suitable for use with 45W, 6.6 Amp AC constant current series system with bi-pin halogen Lamp complete with all accessories such as CI base plate, breakable coupling mounting assembly, gasket, lamp holder, lenses, 2 pin secondary lead plug 2.5 Sqmm copper, stainless steel bolt, spring suitable for connection of adequate length etc confirming to ICAO Anns 14 complete all as specified and directed by Engr-in-Charge. Make : AMA/THORN/SAFEGATE/VARDHMAN.
Supply, installation, commissioning and testing in replacement of bi-directional elevated type high intensity threshold cum Runway End Lights Complete with inner Green And red fitting suitable for use with 200W, 6.6Amp AC constant current series system with bi-pin halogen Lamp complete with all accessories such as CI base plate, breakable coupling, mounting assembly, gasket, lamp Holder,lenses, 2 pin secondary lead plug 2.5 Sqmm copper, stainless steel bolt, spring suitable for connection of adequate length etc confirming to ICAO Anns 14, complete all as specified and directed by Engr-in-Charge. Make : AMA/THORN/SAFEGATE/VARDHMAN
Supply, installation, commissioning in replacement of isolating transformer 5 KV, 50Hz series type encapsulated in polyster resin for all moulded with neoprene rubber as specified and suitable for Air field lighting system confirming to FAA/ICAO and IS-12290 1987 of capacity 200W, 6.6Amp, for runway lighting complete all as specified and directed by Engr-in-Charge. Make : AMA/THORN/SAFEGATE/VARDHMAN
Supply, installation, commissioning in replacement of isolating transformer 5 KV, 50Hz series type encapsulated in polyster resin for all moulded with neoprene rubber as specified and suitable for Air field lighting system confirming to FAA/ICAO and IS-12290 1987 of capacity 45W, 6.6Amp, for runway lighting complete all as specified and directed by Engr-in-Charge. Make : AMA/THORN/SAFEGATE/VARDHMAN
Supply and fixing of 5 KV grade plug, receptacle of type-I Class B connector, suitable for field attachment with 5 KV grade PVC insulated, PVC sheathed single core copper conductor of size cable 6 Sqmm for runway lighting complete male female sets as specified and directed by Engr-in-Charge. Make : AMA/THORN/SAFEGATE/VARDHMAN
Supply and fixing of 5 KV grade plug, receptacle of type-I Class B connector, suitable for field attachment with 5 KV grade PVC insulated, PVC sheathed single core copper conductor of size cable 16 Sqmm for runway lighting complete male female sets as specified and directed by Engr-in-Charge. Make : AMA/THORN/SAFEGATE/VARDHMAN
Supply and fixing in replacement of runway Halogen lamp bipin 200W, 6.6 Amp, complete all as specified and directed by Engr-in-Charge. Make : AMA/THORN/SAFEGATE/VARDHMAN
Supply and fixing in replacement of taxiway Halogen lamp bipin 45W, 6.6 Amp complete all as specified and directed by Engr-in-Charge. Make : AMA/THORN/SAFEGATE/VARDHMAN
Supply, fixing and testing in replacement of runway edge lighting bipin type holder of capacity 200W, 6.6 Amp, conforming to ICAO Anns 14, complete all as specified and directed by Engr-in-Charge. Make : AMA/THORN/SAFEGATE/VARDHMAN
Supply, fixing and testing in replacement of taxiway edge lighting bipin type holder of capacity 45W, 6.6 Amp, conforming to ICAO Anns 14, complete all as specified and directed by Engr-in-Charge. Make : AMA/THORN/SAFEGATE/VARDHMAN
Supply and fixing in replacement of ESNA connector male female 6/16 sqmm cable complete all as specified and directed by Engr-in-Charge. Make : AMA/THORN/SAFEGATE/VARDHMAN
Supply and fixing in replacement of iron cage for runway/ taxiway/End lights fitting with dia of cage 40 CM, Height 45 cm made by flat MS iron strip 50mm and iron mess wire 16 gauge with required nut and bolts and two coat of emulsion paint over a coat of reflexible primer complete all as specified and directed by Engr-in-Charge
M/L for excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft/loose for taking up or laying of cable/poles complete all as specified and directed.
M/L for removing surplus soil to a distance not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
M/L for returning filling in layers including leveling watering and well ramming in layers not exc. 25cm thick complete all as specified and directed.
Supply and laying dry river sand laid in 8 cms before laying of cable and 15 cms above cable in trenche as cable cushioning and covering complete all as specified and directed. Note: for payment purpose punned thickness shall be measured
M/L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed.
M&L PCC 1:3:6 type C 1 using 20 mm graded stone aggregate for repair of base of runway/ taxiway light fitting complete all as directed and specified by Engr-in-Cgarge
M/S MIR HILAL CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .