Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 2 3 AMIT VIJAY APT CHSL KASTURBA CROSS ROAD NEAR BHANU PARK KANDIVALI WEST MUMBAI 400 067 | MUMBAI | MUMBAI | MAHARASHTRA | 400067 | Admitted-Finance |
| 2 | Admitted-Finance 203 ELECON CHAMBER ANDHERI KURLA ROAD VILLAGE TOWN NEAR SAKINAKA TELEPHONE EXCHA CITY ANDHERI EAST MUMBAI MAHARASHTRA 400072 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | Admitted-Finance |
| 3 | Admitted-Finance B 10 KRISHNA INDUSTRIAL ESTATE OPP B I D C GORWA ESTATE VADODARA 390016 GUJARAT | VADODARA | GUJARAT | 390016 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹7.1 L
Closing Date
4 Oct 2021, 1:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT-110010
Defect Rectification and Consultancy for Structural Audit of Block No P 52 to P 57 Baired Place under GE East Delhi Cantt 10
2021_MES_477471_1
3007/Q/2021/1/E3
Open Tender
Job Works
Item Rate
30 days
GE EAST BAIRD PLACE
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
16 Oct 2021
24 Sept 2021
5 Oct 2021
25 Sept 2021
4 Oct 2021
25 Sept 2021
Amount
Inspection of Building
Visual Inspection : for surface damages, flaking, local weaknesses, etc and their damage classification the visual inspection shall largely cover areas of high distress, abnormal variations in structure, Visual inspection would be documented in the form of worksheets, photographic records, and distress over drawings/sketches etc
Non Destructive Testing : Non destructive Evaluation of the structural elements by various tests at required location and structural assessment based on these parameters.
Rebound Hammer : For determining the estimated compressive strength of concrete and uniformity of concrete in terms of surface hardness as per IS 1331 (Part-) 1992.
Ultrasonic Pulse Velocity Test for ascertaining the quality of concrete, soundness and density of concrete, uniformity of concrete in terms of density as per IS 1311 (Part-1) 1992, ASTM, C597-83, BS 6809 1981 and BS 1881 : Part 203 and BS EN : 13791
Corrosion monitoring : To measure the risk and rate of corrosion of steel in concrete by Half cell potential of reinforcement to assess the risk of corrosion.
Concrete cover measurement : Measurement of thickness of concrete cover to reinforcement bars by cover meter test.
PH value test : To draw samples of concrete and PH value test (to check alknity of concrete) as per relevant IS 456:2000, BS8110.
Chemical analysis : To draw samples of concrete and carry out chemical analysis of the samples including measurement of chloride content.
Thermal imaging : To capture the details of active moisture spots in the structures and providing output records in the form of thermal images.
Report and Vetting
Preparing and submitting comprehensive report : consisting of findings from visual inspection, test data, interpretation of results, conclusions and final recommendations.
Repairing Methodology and retrofitting scheme : It includes assessment of adequacy of existing structural components and providing retrofitting scheme to strengthen the inadequate structural components including repair methodology and submission of final report. The recommendation for structural repair and rehabilitation to the structures shall have detailed technical specifications materials to be used.
Vetting of scheme from NITS/ITS/Punjab Engg College/Delhi College of Engg or DTU/Thapar College of Engg.
S P BAGWE CONSULTANTS PRIVATE LIMITED
Indian Consulting Engineers Pvt Ltd
Capstone Consultants Private Limited
GEO DESIGNS AND RESEARCH PVT LTD
INERTIA ENGINEERING SOLUTIONS
Sai Geotechnical Lab
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .