Shri Niranjan Lal GE(S) BTD
BATHINDA MIL STN
REPAIR REPLACEMENT OF INTERNAL UNSERVICEABLE POINT WIRING REWIRING FITTING FIXTURE DBs SUB MAIN WIRING SWITCHES AND CONNECTED ACCESSORIES OF ZONE D AND F MD ACCN AREA OF AIRAWAT ENCLAVE ALBERT EKKA AND MANSA COLONY UNDER AG
2020_MES_368939_1
GE(S) BTD-17/2020-21
Open Tender
Civil Works
Item Rate
180 days
BATHINDA MIL STN
AS PER NIT
8 documents required · 8 mandatory
₹500
GE(S) BATHINDA
₹20,000
Yes
27 Oct 2020
13 Aug 2020
12 Sept 2020
13 Aug 2020
10 Sept 2020
29 Aug 2020
14 Aug 2020 - 25 Aug 2020
Amount
Taking down carefully existing unserviceable copper / aluminum point wiring (light, fan, socket) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, etc and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and directed by Engineer-in-Charge.
M&L point wiring for one light point / bell point /ceiling fan point/ exhaust fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FR-LSH in and including concealed PVC conduit 20 mm dia, medium duty, ISI marked including new, steel terminal sunken boxes suitable of modular switch/socket flush to surface for one light point, fan point , controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable FR-LSH connected to common earth dolly complete including cutting, chasing the surface and then making good the same in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of Sch 'A' ).
All as per item No 2 but for socket outlet 5 pin, 6 Amp on same board complete all as specified and directed by Engineer-in-charge.
All as per item No 2 but for socket outlet 5 pin, 6 Amp on independent board complete all as specified and directed by Engineer-in-charge.
All as per srl item No.2 (here-in-before) but for one socket outlet 6 pin, 6/16 Amp with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sq mm PVC insulated unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 2 here in before but for one light point controlled by two way switch complete all as specified and directed by Engineer-in-Charge.
All as per item No 2 here in before but for call bell point complete all as specified and as directed by Engineer-in-Charge.
M & L for point wiring for one light / fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FR-LSH in existing conduit, and existing sunken boxes but including 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FR-LSH connected to common earth dolly complete including cutting, chasing the surface and then making good the same in CM (1:3) complete all as specified and directed by Engineer-in-charge. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of Sch 'A' ).
All as per item No 8 but for socket outlet 5 pin, 6 Amp on same board complete all as specified and directed by Engineer-in-charge.
All as per item No 8 but for socket outlet 5 pin, 6 Amp on independent board complete all as specified and directed by Engineer-in-charge.
All as per srl item No. 8 (here-in-before) but for one socket outlet 6 pin, 6/16 Amp with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sq mm PVC insulated unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 8 here in before but for one light point controlled by two way switch complete all as specified and directed by Engineer-in-Charge.
All as per item No 8 here in before but for call bell point complete all as specified and as directed by Engineer-in-Charge.
S& F switch piano flush type, 6 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed by Engineer-in-charge.
S& F switch piano flush type, 6 Amp 240 Volt, AC (ISI Marked) two way etc complete all as specified and directed by Engineer-in-charge.
S&F one socket outlet 5 Pin 5 Amp 230 volts AC complete all as specified and directed by Engineer-in-charge. Note:- Switch and socket shall be of same make.
S&F one switch and one socket outlet multipurpose 3 Pin 5 Amp and 6 Pin 15 Amp 230 volts AC complete all as specified and directed by Engineer-in-charge. Note:- Switch and socket shall be of same make.
S&F 6 Amps bell push switch, 250 volts, AC ISI marked complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing call bell Ding-dong, 230 Volts AC supply complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing regulator for ceiling fan electronic step type suitable for 1200/1400 ceiling fan complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing lamp holder angle/straight, including LED bulb 9/10W polycarbonate cased body with back plate suitable for batten fittings for landing T & wind shock complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing one module blanking plate of suitable size to fit in distribution board complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, 8 way, DB SPN 230 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old DB of any type and capacity alongwith MCB etc complete all as specified and as directed by Engineer-in-Charge.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, 4 way, DB TPN 415 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old DB of any type and capacity alongwith MCB etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 Volt complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing n repair MCB, SP, 6 to 32 Amps, 'C' curve, 230 Volts, breaking capacity not less than 10 KA with over load and short circuit protection complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair MCB, SPN, 16 to 32 Amp, 230 Volts, 'C' curve breaking capacity not less than 10 KA with over load and short circuit protection,50 Hz including necessary attachment complete all as specified and as directed by Engineer-in-Charge
Supply and fixing MCB, TPN, 63 Amp, 230 Volts, 'C' curve breaking capacity not less than 10 KA with over load and short circuit protection,50 Hz including necessary attachment complete all as specified and as directed by Engineer-in-Charge
Supply and fixing MCB, TPN, 100 Amp, 230 Volts, 'C' curve breaking capacity not less than 10 KA with over load and short circuit protection,50 Hz including necessary attachment complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in repair MCCB 4 pole, 230 volt, 63 Amp, 50 Hz with rupturing capacity 25KA, 'C' series complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCCB 4 pole, 230 volt, 100 Amp, 50 Hz with rupturing capacity 25KA, 'C' series complete all as specified and directed by Engineer-in-Charge.
Material and Labour for sub main wiring with 2 single core cable 6 sqmm, 1100 votls grade PVC insulated unsheathed of copper multi strandard conductor FRLSH cable with continuous copper earth conductor single core multistranded PVC insulated FRLSH of size 6 sqmm, 1100 votls grade drawing through in & including PVC concealed conduit medium grade of size 20mm along with accessories such as Tee, elbow, bend etc including taking down old sum in wiring of any type and capacity complete all as specified and as directed by Engineer-in-Charge. Note :- Two runs of cable and one run of earthing wire shall be measured as one unit.
Material and Labour for sub main wiring with 2 single core cable 6 sqmm, 1100 votls grade PVC insulated unsheathed of copper multi strandard conductor FRLSH cable with continuous copper earth conductor single core multistranded PVC insulated FRLSH of size 6 sqmm, 1100 votls grade drawing through existing PVC concealed conduit medium grade of size 20mm along with accessories such as Tee, elbow, bend etc including taking down old sum in wiring of any type and capacity complete all as specified and as directed by Engineer-in-Charge. Note :- Two runs of cable and one run of earthing wire shall be measured as one unit.
S & F in repair LED light luminaire 1x10 watt 2 ft including electrical connections with not more than 1.5 mtr long twin core round copper conductor cable of suitable size all as per Havells cat part No. LHEOAOP7UZ6W010 or equivalent model of approved make from list of make attached in tender documents complete all as specified and as directed by Engineer-in-Charge.
S & F in repair energy efficient LED street light of 25 Watt with PDC aluminium body and clear glass with lens for wide beam distribution, top maintainable type with IP 66 degree of protection, fitting should be provided with inbuilt 5KV minimum surge protection, short circuit and over voltage protection facility for driver and fitting including 25 watt LED lamp with GI bracket-01 No, MS clamp-02 Nos suitable for walls/columns metre long twin core round copper conductor cable of 1.50 metre long twin core round copper conductor cable of suitable size and testing complete all as specified and directed by Engineer-in-charge. Make:- SYSKA cat part No. SSK-SLF-CF-25W-WL or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE.
S & F in repair surface mounted, decorative round bulk head luminaire comprising of high brightness LED lamp 10/12 Watt, 6000K polycarbonate with IP65 protection, the system wattage of fitting should not be more than 5 watt ± 10%, surge protection of minimum 2KV, power factor should be more than 0.90, cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 900 lumens, total input voltage range 140-280V AC, colour rendering Index should not be less than 80 complete including all other accessories and fitting arrangement including electric connection connecting with using flexible copper wire twin core upto ceiling rose/conector. Make:- Crompon cat part No. LBHE-10-CDL or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE.
S & F in repair LED Tube rod 18W/ 20W/ 21W/ 22W, Polycarbonate body, 1.2m length, LED T8 (Tubular lamp), 6500K, G13 Lamp holders, 230V, 50Hz with & including precoated CRCA frame/ fitting suitable for holding T8 LED tubular Lamps, 1.2m length, 230V, 50Hz. The frame should be compatible with LED. The total fitting should be complete including LED driver, other accessories and rest complete all as specified and directed by Engineer-in-charge. Note: (i) The LED tube rod and CRCA frame should be of same make and they should be compatible with each other. (ii) The LED Tube shall be warranted for two years from the date of completion of work.
S&F in repair decorative wall mounting light fixture made up of poly carbonate with 7 watt LED bulb ( B-22 base) complete all as specified and directed by Engineer-in-charge.
Supply and laying or fixing or passing through in and including concealed PVC conduit 20mm dia heavy duty, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed twin core 6 sq. mm nominal cross section in service connections including taking down old unserviceable wire complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (PCC 1:2:4 B-1 using 20 mm graded stone aggregates for concrete pit including 10 mm thick CI cover frame) depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point, all as specified as shown in electrical plate No 3 SSR Part-I and testing on completion including taking down old earthing complete all as specified and as directed by Engineer-in-Charge. Note :- PCC chamber shall be constructed at least 1.5 m away from earth pit pipe for watering shall be provided in slanting manner.
S& F in repair switch piano flush type, 6 Amp 240 Volt, AC (ISI Marked) one way etc for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
S&F in repair one socket outlet 5 Pin 5 Amp 230 volts AC for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
S&F in repair one socket outlet multipurpose 3 Pin 5 Amp and 6 Pin 15 Amp 230 volts AC for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
S& F in repair switch piano flush type, 15 Amp 240 Volt, AC (ISI Marked) one way etc for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
Supply and fixing in repair call bell Ding-dong, 230 Volts AC supply for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
S & F in repair LED light luminaire 1x10 watt 2 ft including electrical connections with not more than 1.5 mtr long twin core round copper conductor cable of suitable size all as per Havells cat part No. LHEOAOP7UZ6W010 or equivalent model of approved make from list of make attached in tender documents for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
Supply and fixing in repair LED Tube rod ecofriendly, 20 ( + 10%) watt, polycaarbonate body, 1.2m leength, LED T8 (tubular lamp), 6500K, G13 lamp holders, 230V , 50Hz with and including precoated CRCA frame/fitting suitable for holdinhg T8 LED tubular Lamps, 1.2m length complete. The frame should be compatible with LED. The total fitting should be complete including LED driver, other accessories for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Notes:- (i) AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard. (ii) The LED tube rod and CRCA frame should be of same make and they should be compatible with each other complete all as specified and directed by Engr--in-Charge
Supply and fixing in repair fan regulator for ceiling fan electronic step type suitable for 1200/1400 ceiling fan for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
Supply and fixing in repair lamp holder angle/straight polycarbonate cased body with back plate suitable for batten fittings for landing T & wind shock for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
Supply and fixing in repair MCB, SP, 6 to 32 Amps, 'C' curve, 230 Volts, breaking capacity not less than 10 KA with over load and short circuit protection for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
Supply and fixing in repair MCB, SPN, 16 to 32 Amp, 230 Volts, 'C' curve breaking capacity not less than 10 KA with over load and short circuit protection,50 Hz including necessary attachment for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
Supply and fixing in repair Laminated Hylam sheet cover of existing size at site including fixing of existing switch, socket etc in new sheet for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
Supply and fixing in repair MCB, TPN, 63 Amp, 230 Volts, 'C' curve breaking capacity not less than 10 KA with over load and short circuit protection,50 Hz including necessary attachment for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
Supply and fixing in repair MCB, TPN, 100 Amp, 230 Volts, 'C' curve breaking capacity not less than 10 KA with over load and short circuit protection,50 Hz including necessary attachment for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
Supply and fixing in repair LED Tube rod ecofriendly, 20W/22W polycarbonate body, 1.20m length, LED T8 (tubular lamp), 6500K, G13, 230V, 50Hz for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
Supply in repair fabricating and fixing of meter box of size 900mm x 900mm x 300mm made from 2.25mm thick sheet in wall with suitabe cutting, cement work etc, having double door, single opening and locking arrangement suitable for fixing 04 electric meter and TPN DB box including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
Fixing only Electric Meter and connecting Electric Meter to distribution box of any capacity for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:-(i) AARMAN Complaints shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard. (ii) New electric/ electronic meter will be issued under Sch 'B' and will be collected from store yard of AGE (E/M-IV)
S & F in repair steel sunken boxes of any existing size at site of same board/independent board/power board including fixing of old existing sheet, switch and socket etc fixed on old sunken boxes to make the board fully functional for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
S & F in repair energy efficient LED street light of 25 Watt with PDC aluminium body and clear glass with lens for wide beam distribution, top maintainable type with IP 66 degree of protection, fitting should be provided with inbuilt 5KV minimum surge protection, short circuit and over voltage protection facility for driver and fitting including 25 watt LED lamp with GI bracket-01 No, MS clamp-02 Nos suitable for walls/columns metre long twin core round copper conductor cable of 1.50 metre long twin core round copper conductor cable of suitable size and testing for AARMAN COMPLAINTS on daily basis complete all as specified and directed by Engineer-in-charge. Make:- SYSKA cat part No. SSK-SLF-CF-25W-WL or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE. Note:- AARMAN COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
M/s NIRMAN BUILDERS
L H ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .