Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18,000Accepted-AOC 1 G ROAD GOREGOAN W 1 T NAGAR ROAD NO 3 2 402 SURYA NIWAS L T NAGAR MUMBAI 400062 | MUMBAI | MUMBAI | MAHARASHTRA | 400062 | 1 | Accepted-AOC L1 | |
| 2 | 1₹21,240Accepted-AOC 36 MASCARENH BUILDING M G ROAD PANAJI GOA | NORTH GOA | GOA | 403001 | 1 | Accepted-AOC L1 | |
| 3 | 1₹35,400Accepted-AOC | 1 | Accepted-AOC L1 | |
| 4 | 1₹1.2 LAccepted-AOC C 2 2ND FLOOR GILBERT MANSION NEXT TO HOTEL POORNIMA ANSABHAT MAPUSA GOA | NORTH GOA | GOA | 403001 | 1 | Accepted-AOC L1 |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
14 Dec 2022, 5:00 pmClosed
Principal
Goa College of Pharmacy Panaji Goa
Supply of Laboratory Equipment
2022_GCP_6115_1
No.- 20/03/16 - 17/SP/GCP/partfile-1/8
Open Tender
Laboratory and scientific equipment
Supply
90 days
Panaji
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
₹5,000
Yes
2 Jan 2024
5 Dec 2022
15 Dec 2022
5 Dec 2022
14 Dec 2022
5 Dec 2022
UV cabinet Closed cabinet, three light source Long wavelength 366 nm, Short wavelength 254 nm, visible light, protected lids for visualization, metal body
Hot Plate Rectangular hot Plate Make, heating element nichrome wire. 10" x 12" Rectangular hot Plate Make, heating element nichrome wire. 10" x 12
Laboratory Centrifuge Stable Speed output, Low sample temperature rise, High capacity, Provision for easy change of rotors and reduction adapters, Brushless induction motor with variable frequency drive, Microprocessor controller with Digital Display, 7 segment LED display of speed, Digital countdown timer,, Last set parameter Recall, Automatic door opening, Stainless steel Centrifuge chamber Technical Data: Max Speed 6000 rpm, Max RCF 5070 g, Max Capacity 400 ml, Digital Timer range 0-59 min, W X D X H 380 X 470 X 300 mm, Power Supply 220 - 240 Volts, 50 Hz, Single phase, Rotor Heads - Swing out Heads - (with graduated glass tubes) 16 X 15 ml, 12 X 15 ml, 8 X 15 ml Reduction Adapters – 1 X 3 ml, 1 X 5 ml 1 X 8 ml
Heating Mantle Temperature Controller Capacity 1 Lt Power 300W
Electrode for pH Meter/ Glass Electrode pH range Full Scale -0-14, Diameter 12mm, Length 150mm, Ultem glass, Reference- Refillable, Junction Number Double (2); Junction Material - Ground Epoxy and pHASE; Reference Solution 3.5 M KCl (liquid); Glass Shape- Bulb Body,Temperature Range 0-100 degrees C, Strain Relief – Yes, BNC Boot –Yes, Bulb Protection Removable Guard
Water Bath • Digital boiling baths each with 6-12 concentric rings to accommodate different size round bottom flasks. • digital backlit LCD display and a front touch pad for temperature and timer adjustments. • eight extraction places • Constructed of high grade stainless steel • Digital PID controller • Adjustable temperature compensation • Timer function including duration timer and delay start timer • Temp ambient to 99 degree • Power 1500 W, single phase, 220 V • 15 lits
Thermostatic control Water bath Technical specifications: Parameter RWB 6 Temperature range RT ± 5„ƒ~99„ƒ Temperature stability ±0.5„ƒ Tracking alarm ±2„ƒ Chamber volume 15 Ltrs Interior Dimension (W—D—H, mm) 450—300—110 Timing range 1~999min Remark Double lines six holes Electrical requirements 220V, 50Hz, Single phase Power Consumption 1500W • Microprocessor control with timing function • Digital display • Audible and visual alarm for over temperature
Raut Scientific and General Traders
Lawrence and Mayo (India) Pvt. Ltd.
MINA SCIENTIFIC & INDUSTRIAL TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .