Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance B 4 NEAR CENTRAL PARK RHB COLONY SOUTH EXTN BALICHA UDAIPUR RAJASTHAN | UDAIPUR | UDAIPUR | RAJASTHAN | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹4.6 Cr
EMD Value
₹9.1 L
Closing Date
12 Jan 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer and DCE (CED, PD, EP)
Chief Engineer and DCE (CED, PD, EP), 2nd Floor Sarathi Building, NFC, ECIL Post, Hyderabad
CIVIL AND OTHER ALLIED WORKS FOR CONSTRUCTION OF EMERGENCY WATER TANKS AND OTHER MISCELLANEOUS WORKS AT NFC KOTA
2022_NFC_731514_1
C/1294/2022
Limited
Civil Works
Works
300 days
Rawatbhata
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹9.1 L
13 Jan 2023
28 Dec 2022
13 Jan 2023
28 Dec 2022
12 Jan 2023
28 Dec 2022
Amount
I. EARTH WORK :
Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed, but excluding shoring and strutting.
Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed, but excluding shoring and strutting.
Earth work in EXCAVATION below ground level for all kinds of works in HARD ROCKS for a depth upto 1.5m by CHISELLING (pneumatic or manual), wedging or any other agreed methods (where blasting is prohibited for any reason or as decided) including all related works, all equipments required for chiselling, and cutting upto required levels, dressing and trimming of sides, levelling and grading of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal of spoils to spoil heaps and stacking of usable excavated materials within a lead of 100m etc. all complete as directed.
Earth work in EXCAVATION below ground level for all kinds of works in HARD ROCKS for a depth beyond 1.5m and upto & inclusive of 3.0m by CHISELLING (pneumatic or manual), wedging or any other agreed methods (where blasting is prohibited for any reason or as decided) including all related works, all equipments required for chiselling, and cutting upto required levels, dressing and trimming of sides, levelling and grading of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal of spoils to spoil heaps and stacking of usable excavated materials within a lead of 100m etc. all complete as directed.
Filling available excavated earth (Crused Sand avialable inside compus) in plinth, sides of foundation etc., in layers not exceeding 20cm in depth, consolidating each deposited layer by r4amming and watering, lead upto 50m and lift upto 1.5mof local earth by mechanical transport also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. Complete
Lead charges for the 1/ 2 KM or part thereof for additional lead over the initial lead of 50 m by mechanical transport, including loading, unloading, stacking, the disposable soil, rock etc., Note: Measurement of lead charges will be based on truck measurement with a deduction of voids @20% and 50% for soils and rock or debris respectively.
a) For rock/debris above for 1KM upto 1.5KM.
II. CONCRETE (PLAIN AND REINFORCED) :
providin g & laying PCC 1:2:4 including by insitu mixing using Weigh Batching or RMC of Ultra Tech, Birla Ready Mix using Portland Pozzolana Cement conforming to IS 1489 Part-1 (M/s. ACC, Ultra Tech,Ambuja, make) with crushed stone sand and graded stone aggregates of 20mm maximum size including mixing superplasticizer of brand M/s. Fosroc, Demech, Huntsman, Pidilite, Sunanda Chemicals, Agro Chemicals, MBT in proportion as per Manufacturer's Specifications, Pumping / Lifting of concrete to the required heights, Concrete laid to proper level, profile and slope, placing concrete, consolidation, finishing, curing, etc.,
Reinforced Cement Concrete by insitu mixing using Weigh Batching or RMC of Ultra Tech, Birla Ready Mix of Grade M - 25 (Minimum Cementitious Content not less than 330 Kg/Cum) up to specified level using Portland Pozzolana Cement conforming to IS 1489 Part-1 (M/s. ACC, Ultra Tech,Ambuja, make) with crushed stone sand and graded stone aggregates of 20mm maximum size including mixing superplasticizer of brand M/s. Fosroc, Demech, Huntsman, Pidilite, Sunanda Chemicals, Agro Chemicals, MBT in proportion as per Manufacturer's Specifications, Pumping / Lifting of concrete to the required heights, Concrete laid to proper level, profile and slope, placing concrete, consolidation, finishing, curing, etc., but excluding Formwork and reinforcement as specified and directed.
a) Below FFL
b) Above plinth level from 0 to +10 level
c) Above plinth level from 10 to +20m level
d) Concrete in flooring
Reinforced Cement Concrete by insitu mixing using Weigh Batching or RMC of Ultra Tech, Birla Ready Mix of Grade M - 30 (Minimum Cementitious Content not less than 350 Kg/Cum) up to specified level using Portland Pozzolana Cement conforming to IS 1489 Part-1 (M/s. ACC, Ultra Tech, Ambuja make) with crushed stone sand and graded stone aggregates of 20mm maximum size including mixing superplasticizer of brand M/s. Fosroc, Demech, Huntsman, Pidilite, Sunanda Chemicals, Agro Chemicals, MBT in proportion as per Manufacturer's Specifications, and water proofing compound to make the concrete leak proof Pumping / Lifting of concrete to the required heights, Concrete laid to proper level, profile and slope, placing concrete, consolidation, finishing, curing, etc., but excluding Formwork and reinforcement as specified and directed.
a) Above plinth level from 10 to +20m level
b) Above plinth level from +20 to +30m level
III. FORM WORK :
Providing centring and shuttering using 12mm thick prelaminated plyboard including strutting, propping, staging made out of steel frames/H-frames/Steel Pipes/Cup and Lock System etc., and removal of the same as required including chamfers, splays, keys, wedges, nails, bracings, brackets and applying One (1) coat of shuttering oil (Cemol/Fosroc make/any other approved equivalent) on all shuttering surfaces coming in contact with concrete, etc., if required, for insitu Reinforced Concrete and in Plain Cement Concrete works complete as specified and directed.
a) Below and Upto Finish Floor Level
b) Above Finish Floor Level up to 30m level.
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the Zequired duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once for all works irrespective of repeatition and duration of scaffolding.
IV. REINFORCEMENT & STRUCTURAL STEEL
Supply, fabrication and erection of Reinforcement bars for Reinforced cement concrete items at and at all depths and heights below and above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more conforming to IS 1786 of Tata, Vizag,Sail, JSW make, including transport to site, loading and unloading, making fan hooks of required shape, dowels for bonding masonry, transporting steel to site, decoiling, removing of scales, straightening, cutting, bending, fixing bars with chairs, space bars wherever required, in position with two strings of 18 gauge soft drawn annealed MS binding wire inclusive of its supply etc., complete as specified and directed.
Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E250A / E250B0/ E250BR (confirming to per IS:2062) at all locations and levels UPTO & INCLUSIVE OF 10 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per EIL Specification No. 6-79-0020 (or as per Job Specification, wherever applicable) after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.
Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).
Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or Job Specification, whereever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).
Providing and fixing in position Anchor Shells/Expansion shells of approved make of best quality of 16mm dia for anchoring supporting structural steel columns with necessary MS bolts of required size/length including drilling holes in RCC flooring, aligning bolts to position, proper level, Bolts,Washers Labour, etc., complete as directed.
V FLOORING :
Providing, fabricating and fixing/ laying SS 304L sheet lining over flooring, vertical surfaces, kerb wall etc. In wet area, below tanks, pumps and other areas, using 2 mm thick sheet, fabrication, cutting the sheet to the required sizes, welding TIG or any approved method, corners and walls stiffened using angles or channels made out of sheet or any standard rolled sections, welding continuously, including installing lining or tanks in position, testing the welded joints using DP test and radiographic test complete as directed. Note: 1. Total joints of underground lining shall be tested for DP. 2. Radio graphic testing should be done for 10% of the total welded joints.
Supplying and applying self-smoothening polyurethane floor finish over Vacuum dewatered/ Heavy duty or other flooring in wet section & other areas consisting of : 1. Priming coat @ 1 litre/ 5 Sq.m.. of floor area per coat, 200 micron DFT (with moisture insensitive epoxy primer CIPOXY 16, of “Cipy Polyurethanes pvt ltd” or approved equivalent), 2. 2mm thick Polyurethane water based self-smoothening floor Screed underlay (Durascreed 2000 of “Cipy Polyurethanes pvt ltd” or approved equivalent), 3. 2mm thick Polyurethane Self-smoothening floor topping (Duracrete 2000 of “Cipy Polyurethanes pvt ltd” or approved equivalent) including surface preparation (cleaning, machine grinding, filling pot holes, sealing cracks, etc.), finishing etc. all complete in accordance with approved manufacturer’s specification
Supplying and applying 75mm wide and 100 mm deep (vertical) covings (in areas finished with PU floor or other finish) finished radial including application of primer, laying of PU mortar screed, layering smooth with epoxy putty and final top coating with PU-FK111 in two coats,sealer coat to give total 200 microns minimum thickness, preparation of surface, finishing etc. all complete using materials of “Cipy Polyurethanes pvt ltd” or approved equivalent in accordance with approved manufacturer’s specification
Supplying and applying self-levelling chemical resistant Epoxy floor finish in Pickling Shop or other areas over Vacuum dewatered/ Heavy duty or other flooring consisting of : 1. Priming coat (with moisture insensitive epoxy primer CIPOXY 16, of “Cipy Polyurethanes pvt ltd” or approved equivalent, 200 microns DFT), 2. 2.1mm thick self leveling epoxy based screed (Cipoxy 90 & Aggregates of “Cipy Polyurethanes pvt ltd” or approved equivalent), 3. 0.2mm thick epoxy coating system (Cipoxy FC 110 of “Cipy Polyurethanes pvt ltd” or approved equivalent) to be applied by roller in two coats. 4. 0.5mm thick Novalac epoxy based system cured with a polyamine curing agent (Cipoxy EPN 100 of “Cipy Polyurethanes pvt ltd” or approved equivalent) including surface preparation (cleaning, machine grinding, filling pot holes, sealing cracks, etc.), finishing etc. all complete in accordance with approved manufacturer’s specification
Supplying and applying 75mm wide and 100 mm deep (vertical) covings (in areas finished with chemical resistant Epoxy floor or other finish) finished radial including application of primer, laying of PU mortar screed, layering smooth with epoxy putty and top two coats of chemical resistant of Epoxy Coating ,sealer coat to give total 200 microns minimum thickness preparation of surface, finishing all complete using materials of “Cipy Polyurethanes pvt ltd” or approved equivalent in accordance with approved manufacturer’s specification .
Providing and laying acid resistant, vitrified tiles of approved size as per manufacturer's specs. in floor/ skirting/ Dado laid over and including bitumen priming layer, 12mm thick Bitumen mastic layer and 6mm thick resin type chemical resistant mortar conforming to IS: 4443 including raking out and flush pointing of joints with resin type chemical resistant mortar, preparation of back ground surface, finishing etc. all complete.
Minimum 10mm thk. tiles of approved size for flooring
Minimum 6mm thk. tiles of approved size for skirting/ dado
VI: DOORS AND WINDOWS
Supplying and fixing fully glazed anodized ( 25 micron) / electrostatic powder coated (25 micron, approved shade) aluminium doors / windows /partitions /ventilators including frame & shutter with approved make extruded tubular aluminium sections and glass fixed with EPDM gasket and anodized/powder coated aluminium beading including fixing the frame to masonry/RCC by counter sunk 100mm long brass screw and dash fastener to M-15 grade concrete in minimum 150mm x 150mm x 50mm sized block (for brick masonry only)/RCC, finishing, making good of any damaged work etc. all complete. (Note: Refer EIL standard nos 7-75-0014, 7-75-0015)
Aluminium glazed doors with cup pivots of aluminium alloy to IS designation NS-4 of IS-737 and IS designation of A-5-M of IS- 617, Heavy duty hydraulically operated, adjustable floor mounted door closer conforming to IS:6315 (single/double action), 250mm and 150mm long, 10mm dia anodized. Aluminium tower bolts as per IS : 204 one each for each shutter, brass body mortice lock (6 levers, as per IS : 2209) with aluminium handle on both sides, etc. all complete for each shutter, with approved shade electrostatically powder coated aluminium sections and 5mm thk. toughened glass as per IS:5437.
Fixed type partition with approved shade electrostatically powder coated aluminium sections and 5mm thk. toughened glass as per IS:5437
Extra for providing & applying transluscent cast vinyl self adhesive washable type film with sandblasting effect (of 3M(TM) scotchcal(TM) frosted crystal 7725-324 or approved equivalent) and of approved graphic design (electronic/ computer plotted & cut) over glass surface in door/ windows/ partitions etc. including preparation of base surface, cleaning, fininshing etc. all complete. (only area covered by 3M film shall be measured for payment)
IX. PLASTERING & POINTING
Sand faced plaster 20 mm thick in 2 coats over exterior masonry and concrete surfaces at and at all heights above plinth level as given below with base coat in cement mortar 1:4 (1 cemen:4 sand) with approved integrated water proofing compound @ 2% by weight of cement, of M/s. Fosroc/Demach/ Huntsman/ Pedilite/ SIKA Qualcrete / MBT or as per manufacturer’s specifications, 12 mm thick and finishing coat in CM 1:3 (1 cement:3 sand), 8 mm thick, final rendering, making necessary grooves, bands, drip moulds as required, double steel/tubular scaffolding wherever necessary, hacking of concrete surfaces, curing, etc., complete as specified and directed.
VIII. PAINTING:
Providing and applying/ finishing the walls/ RCC surfaces with Premium antifungus 100% Acrylic smooth exterior paint with silicon additives with low VOC (Volatile Organic Compound) content (Snowcryl-XT of 'Snowcem India Ltd. or approved equivalent) of required shades on new work applied in two or more coats at the rate of 1.43 ltr/ 10 Sq.m. over and including base coat of waterproof cement paint (of Snowcem Plus or approved equivalent) including cleaning, preparation of surfaces, curing etc. all complete.
IX. WATERPROOFING :
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm.The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
X. MISCELLANEOUS ITEMS :
Supplying, assembling, lowering and fixing in position , ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 8110, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including fixing in concrete and required hire & labour charges, fittings & accessories like flanges , bolts etc. , all complete, for all depths, as per direction of Engineer-in-charge.
Stainless Steel Vent pipe 100 Dia
Supplying and fixing in position 230mm wide x 5mm thick approved PVC WATER STOPS as per manufacturer's specifications in R.C.C. Structures including cutting, fixing, jointing by vulcanising etc. all complete as shown specified and directed.
Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable), preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).
Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable), preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).
GOEL CONSTRUCTIONCO
stage.html
html • 0.02 MB
finance_769296.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .