Supply Installation and Configuration of Gateway at 132 KV GIS Hanuman Setu 132 KV GIS Mehtab Bagh and 132 KV SS Mohaan Road Under ETD I Lucknow
2026_UPTCL_1164817_1
Very Short TERM E-TENDER 07/ETD-I (L)/2026-27
Open Tender
Electrical Works
Item Rate
30 days
ETD-I
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AC No 0758002100008830 IFSC PUNB0691100
₹21,000
31 Aug 2026
29 Jun 2026
8 Jul 2026
29 Jun 2026
7 Jul 2026
29 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | Scope: Supply , installation and configuration of Gateway for telementary data over IEC104 protocal to SLDC Lucknow and Modipuram at 132kV GIS s/s HanumanSetu under ETD-I, Lucknow. | - | - | - | - |
| 3 | Providing & Installation of New Gateway at 132 KV S/S Hanuman Setu Lucknow with following specification as follows -
(1) Multiple-Master Communication capability.
(2) Support IEC60870-5-101/103/104, DNP3serial/TCP MODBUS RTU/ASCII/TCP,IEC62056-DLMS, IEC61850, SNMP, SNTP,MQTT
(3) Data Point Support:-5000
(4) Port Connectors: 4 Serial (RS232/485) and 2 Ethernet
(5) Power Supply (AC-DC) 85-265VAC 50-60HZ or 100-370VDC
(6) Reliability: IEC61850-3 complitant hardware,
(7) Time Sync based on NTP/SNTP/NEMA/Protoco specific Synchronization (IEC104/DNP3.0etc)
Suitable for Existing SEL Make SCADA System as Installed at 132 KV S/S Hanuman Setu work Included as Installation & all Software configuration and its testing if required as per site condition and all other associated work to complete the job satisfactory. Except BCU/ relay configuration, Supply of any other material mentioned above like fibre Cables/splicing and field wiring termination etc, | - | Nos | - | - |
| 4 | Following work to be carried out for Lucknow SLDC -
Work Included:-
(a)Complete checking of SAS gateway panel included architecture and settings.
(b) Programming and Configuration of gateway with address & settings(provided by client) to link from Substation to data centre Lucknow
(c) Complete testing of SAS gateway and complete data communication link b/w Substation to data centre Lucknow | - | Nos | - | - |
| 5 | Following work to be carried out for Modipuram ALDS -
Work Included:-
(a)Complete checking of SAS gateway panel included architecture and settings.
(b) Programming and Configuration of gateway with address & settings(provided by client) to link from Substation to data centre Modipuram.
(c) Complete testing of SAS gateway and complete data communication link b/w Substation to data centre Modipuram. | - | Nos | - | - |
| 6 | IEC61850 based BCPUs. ICD/.CID file configuration of SEL make relays for 132kV & 33kV Feeders. i). 132kV Feeders-5Nos
ii). 33kV Feeders-14Nos | - | Nos | - | - |
| 7 | Scope: Supply , installation and configuration of Gateway for telementary data over IEC104 protocal to SLDC Lucknow and Modipuram at 132kV S/s Mehtabag under ETD-I, Lucknow. | - | - | - | - |
| 8 | Providing & Installation of New Gateway at 132 KV S/S Mehtabag Lucknow with following specification as follows -
(1) Multiple-Master Communication capability.
(2) Support IEC60870-5-101/103/104, DNP3serial/TCP MODBUS RTU/ASCII/TCP,IEC62056-DLMS, IEC61850, SNMP, SNTP,MQTT
(3) Data Point Support:-5000
(4) Port Connectors: 4 Serial (RS232/485) and 2 Ethernet
(5) Power Supply (AC-DC) 85-265VAC 50-60HZ or 100-370VDC
(6) Reliability: IEC61850-3 complitant hardware,
(7) Time Sync based on NTP/SNTP/NEMA/Protoco specific Synchronization (IEC104/DNP3.0etc)
Suitable for Existing Siemens Make SCADA System as Installed at 132 KV S/S Mehtabhag work Included as Installation & all Software configuration and its testing if required as per site condition and all other associated work to complete the job satisfactory. Except BCU/ relay configuration, Supply of any other material mentioned above like fibre Cables/splicing and field wiring termination etc, | - | Nos | - | - |
| 9 | Following work to be carried out for Lucknow SLDC -
Work Included:-
(a)Complete checking of SAS gateway panel included architecture and settings.
(b) Programming and Configuration of gateway with address & settings(provided by client) to link from Substation to data centre Lucknow
(c) Complete testing of SAS gateway and complete data communication link b/w Substation to data centre Lucknow | - | Nos | - | - |
| 10 | Following work to be carried out for Modipuram ALDS -
Work Included:-
(a)Complete checking of SAS gateway panel included architecture and settings.
(b) Programming and Configuration of gateway with address & settings(provided by client) to link from Substation to data centre Modipuram.
(c) Complete testing of SAS gateway and complete data communication link b/w Substation to data centre Modipuram. | - | Nos | - | - |
| 11 | IEC61850 based BCPUs. ICD/.CID file configuration of Siemens make relays for 132kV & 33kV Feeders. i). 132kV Feeders-8Nos
ii). 33kV Feeders-24Nos | - | Nos | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.17 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
BOQ_2184310.xls
BOQ • 0.31 MB
TD07.pdf
Tender Documents • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .