Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.9 LAccepted-AOC C 150 ADG P CHENNAI | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹49.1 L+₹1.1 L (2.36%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹49.8 L+₹1.8 L (3.69%)Rejected-Finance 109 D ALLAI SALT COMPOUND OLD LAKSHMI THEATRE KRISHNAPURAM COONOOR 643102 THE NILGIRIS | COONOOR | THE NILGIRIS | TAMIL NADU | 643102 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹49.8 L+₹1.8 L (3.75%)Rejected-Finance 7 345 C 1 AERO NAGAR KANGEYAMPALAYAM KADAMPADI SULUR COIMBATORE TAMIL NADU 641401 | COIMBATORE | TAMIL NADU | 641401 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹49.8 L+₹1.8 L (3.80%)Rejected-Finance DR SEWALIYE SIVAJI GANESAN NAGAR 3RD STREET DINDIGUL 642 001 | COIMBATORE | TAMIL NADU | 642001 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹97,400
Closing Date
6 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVN OF CERTAIN SANCTIONED WORK AND MAJOR REVENUE WORKS AT AFS SULUR
2023_MES_623541_1
8614/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹97,400
Yes
29 Nov 2023
16 Oct 2023
7 Nov 2023
16 Oct 2023
6 Nov 2023
30 Oct 2023
16 Oct 2023 - 26 Oct 2023
Amount
SCHEDULE A BOQ
Surface excavation n.exc 30 cm deep and averaging 15cm deep in soft/loose soil complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying XLPE cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified and as directed.
M&L PCC (1:4:8) Type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L Reinforced cement concrete Type B-0, 1:2:4 using 12.5mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc to provide flat rough finished concrete surface complete all as specified and as directed.
M&L Reinforced cement concrete Type B-0, 1:2:4 using 12.5mm graded stone aggregate slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and as directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) to provide flat rough finished concrete surface complete all as specified and as directed.
M&L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide to provide flat rough finished concrete surface complete all as specified and as directed.
M&L Reinforced cement concrete Type B-0, 1:2:4 using 12.5mm graded stone aggregate as in Chajjas complete all as specified and as directed.
M&L Formwork to chullah hoods, chajjas, troughs and similar items including edges to provide flat rough finished concrete surface complete all as specified and as directed.
S&F High strength corrosion resistant TMT steel bars of Grade Fe–500 of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S&F High strength corrosion resistant, TMT steel bar of grade Fe-500, 5 mm dia and above and up to 10 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips in stirrups , spacers and binders etc complete all as specified and as directed.
M&L 100 mm thick PCC (1:4:8) type-D-2 using 40 mm graded stone aggregate as in sub base floors complete all as specified and as directed.
M&L 25mm thick Cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate as in floors complete all as specified and as directed.
M & L pre-cast cement concrete block masonry with solid blocks, type C-1, in PCC 1:3:6 using 20 mm graded aggregate, exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed.
M&L Rendering 10mm thick on brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed.
M&L preparation on newly plastered wall surfaces and applying two coats of oil bound distemper over the wall treated with 2mm thick plaster of paris putty and one coat of alkali resistant primer complete all as specified and directed.
M&L Rendering 15 mm thick on brick or concrete wall surfaces, in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L preparation on newly plastered wall surfaces and applying two coats of cement base paint one coat of alkali resistant primer complete all as specified and directed.
M&L 75mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded stone aggregates), as in Plinth protection/ Path including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement, complete all as specified and as directed.
Note for item No 21 :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and as directed.
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L Preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Note for item No 26 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
S& F Steel rolling shutters with out ball bearing, spring as per specified including top cover, anchoring rod, hasp and staple with one shop coat of primer and two coats of synthetic enamel paint with gear operated box (approved quality ) erected in position and making good the surface after fixing including locking system complete all as specified and as directed .
S&F Pre painted Coloured corrugated Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed.
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Note for Item No 38 & 39:- (Pre-painted coloured Galvalume roofing) :-
(i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
(ii) The contractor shall ensured that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
(iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
M & L Aluminium powder coated of three track sliding window consisiting of outer frame top & sides (section no-20831) of size 92.0x31.75x1.5mm weighing 1.06 Kg/m, frame bottom (Section No 20832) of size 92.0x31.75x1.5mm weighing 1.248Kg/m , shutter to plain vertical (Section No 21093) of size 39x18x1.5mm weighing 0.634 Kg/m, shutter interlock vertical frame (section 21094) of size 39x18x1.55 weighing 0.734 Kg/m, shutter bottom horizontal frame (Section No 20551) size 40x20x1.5mm weighing 0.484 Kg/m, with powder coating of min thickness 50 micron , sliding type with out sash bars, including 4mm thickness colour glass, rubber packing, snap beading screws with stainless steel wire mesh, complete all as specified and directed.
Note for item No 44 :- The minimum thickness of powder coating shall be 50 micron
M & L damp proof course 40 mm thick, in plain cement concrete1:2:4, type B-0, using 12.5 mm graded stone aggregate including necessary formwork complete all as specified and as directed
M&L 150 micron thick, Polythene film laid over a coat of bitumen primer, @ 0.30 to 0.50 kg per sqm complete all as specified and directed
S&F Steel work in tubular trusses and columns including special shaped washer etc complete using ERW or induction butt,welded tubes conforming to IS 1161-1979 grade ST-240 complete all as specified
S&F Framed brackets of angles or tees with web and flanges, cut to shape, drilled and counter sunk for screw, including bending and welding angles, as necessary , gusset plates, riveting, etc. n exc10 kg each brackets, conforming to Fe.290.Gde -E-165 complete all as specified
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted , bolted or welded attachment.(Fe 410 -W (Gde- E-250) quality -A complete steel all as specified
S&F MS flat iron wind ties for roof including securing bolts and all necessary drilling, bolting or riveting, etc. , and similar work conforming to Fe-290 Gde E-165 all as specified and as directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, n exc 5cm long diameter of neck 5 to 10mm complete all as specified and directed.
M&L Preparation of new steel surface of any description n. exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Note for item No 53 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
M&L Hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 100 mm thick PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as in sub base floors for receiving tiles complete all as specified and as directed.
M & L moorum/red bajri filling including spreading and levelling in layers not exceeding 15 cm thick, spread, levelled and rammed Including watering complete all as specified and directed.
M&L Vitrified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer, 15 mm thick in Cement Mortar 1:6 complete all as specified and as directed.
M&L Vitrified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including backing coat with 15 mm thick in Cement Mortar 1:6 complete all as specified and as directed.
Note for item No 67 & 68 :- (i) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm.
(ii) The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
S & F Machine pressed rubber moulded precast concrete interlocking paver block with grey cement and pigment any shape and size, polished confirming to IS-15658 of 80mm thickness M-40 grade, laid over and including M sand cushion of 50mm thick complete and packing the sides with PCC 1:3:6 complete all as specified and directed.
(b) The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
M&L False ceiling using GI snap grid size 60x60cm with main runner 38mmx24mm, wall angle & cross tee 29mmx24mm wall angle 24mmx24mm suspended with 4mm dia GI Wire fixed with steel dash fasteners carrying max load upto 8.1 Kg/Sqcm including supply and fix 4mm thick designer ceiling board complete all as specified and as directed by Engineer-in-Charge.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1: 4 complete all as specified and directed.
M&L point wiring using approved colour coding as per IS with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through 20mm dia PVC conduit fixed on surface of wall, columns etc including PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) copper conductor as earth wire and connected to earth dolly for the following complete all as specified and directed.
One light point/ceiling fan/exhaust fan/bell point controlled by one switch
All as per item No. 75 here in before but for One 3 pin socket out 6 amp on the same board
All as per Sl No 75 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 16A switch socket independently
S&F factory made powder coated distribution board SP & N 8 way double door, including 200 Amp rated bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 complete all as specified and directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and including suitable size PVC conduit with all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.
Note for Item No 80:- (a) 2 runs of 6 sqmm cable along with 1 run of 6 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
S & F modular switch 1 way 6 amp.1 module complete all as specified and directed.
S & F modular switch 1 way 16 amp.1 module complete all as specified and directed.
Supply & fix modular socket outlet 6A - 2/3 pin combined 2 module,complete all as specified and directed.
Supply & fix modular socket outlet 6A/16A - 2/3 pin combined 2 module,complete all as specified and directed.
Supply & fix modular White cover plate with frame, 3 module complete all as specified and directed.
Supply & fix modular White cover plate with frame, 6 module complete all as specified and directed.
Supply & fix modular White cover plate with frame, 8 module complete all as specified and directed.
S & F modular Metal flush box, 3 module complete all as specified and directed.
S & F modular Metal flush box, 6 module complete all as specified and directed.
S & F modular Metal flush box, 8 module complete all as specified and directed.
Supply and fixing LED light fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 5 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing ceiling fans with brushless direct current motor (BLDC), five star rated, 230V, Min air delivery 210 CFM with service value 6.00 BEE., 1200 mm sweep complete with blades, down rods and fittings accessories like flexible copper cord if size 1.5 sqmm etc, complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
S&F electronic modular fan regulator 230 volts, step type, socket type, hum free 120 watt 2 Module complete all as specified and directed.
Supply & fix single pole MCB 6 to 32 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
Supply & fix single pole neutral, MCB 32 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
Supply and fixing LED street light fitting 20 Watt, 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
M & L for making connection of PP-R distribution branch with PP-R main of sizes 16 to 40 mm bore by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
Supply and fixing PP-R Gate Valves (Brass insert) 25 mm outer dia with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
S & F 25 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. all as specified and directed.
Note for item No 104 :- (a) The unit rate shall include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accessories such as pipe hooks, screws clamps etc
(b ) Wall thickness of pipes shall be all as per IS : 15801
S & F ball brass valves of size 25mm bore, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at level not exc 1.5 m above complete all as specified and as directed.
S & F rotational moulded polythene water storage tank of 500 Ltrs capacity cylindrical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet hoisted and fixed in position all as specified in SSR part -I including complete all as specified and directed.
S & F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets complete all as specified and directed
M & L earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised iron earth wire 4mm dia by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 15mm bore (dia) medium grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6, type C-1 using 20mm graded stone aggregate and Pre-cast RCC Cover Slab of size 300x300x40 mm in Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate, reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, returning, filling in and removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and testing on Completion etc complete all as per specified and directed.
Note for Item No 111:- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be calibrated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone without extra cost to Govt till desired result is obtained.
S&F factory made powder coated distribution board VTPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 complete all as specified and directed.
S&F MCCB four pole, 63 Amp ultimate breaking capacity 16 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed.
S&F MCCB four pole, 40 Amp ultimate breaking capacity 16 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed.
S & F 40 mm bore GI tubing 'light grade' for protection of LT cables fixed to walls/ poles/ road crossing including clamps and fittings complete all as specified and directed.
M&L Fly ash bricks using modular bricks as in cable protection cover complete all as specified and directed.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and as directed.
Note for Item No 121 :- In case sufficient sand not obtained from excavation, the required additional qty shall be obtained from out side MD land as directed by the Engineer-in-Charge and the rate is deemed to be included the above provision also.
Supply and fix in repairs to MS C-Track with accessories without cable of existing size and gauge suitable for 3/2 Ton crane complete all as specified and directed. Make : Rockwell or equivalent approved as directed
Supply and fix in repairs to 6+2 pendent suitable for 3/2 Ton EOT crane complete all as specified and directed. Make:-Schneider or equivalent approved as directed
Supply and fix in repairs to feston trolley suitable for 3/2 Ton Rockwell EOT crane complete all as specified and directed.
Supply and fix in repairs to CT, LT, Hoist limit switch with connected arrangements of 3/2 ton EOT Crane complete all as specified and directed. Make: Rockwell or equivalent approved as directed
Supply and laying of PVC copper conductor electric flat cable of size 1.5 sqmm, 16 core on wall, floor, ceiling etc including taking down existing cable complete all as specified and directed.
Shree Amritha builders
K.AYYAPPAN
p.chinnasamy
N SARAVANAN
G Perumal and co
GMS Builders
KSR AND COMPANY
Lucky Enterprises
SARASWATHI CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .