Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.0 CrAccepted-AOC SCO 36 SECTOR 7 C MADHYA MARG CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹5.0 Cr | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹5.5 Cr+₹47.0 L (9.35%)Rejected-AOC VPO MAJARI TEHSIL SHRI NAINA DEVI DISTT BILASPUR HP | ₹5.5 Cr+₹47.0 L (9.35%) | L-2 | Rejected-AOC Not found L-1 |
| 3 | L-3₹5.6 Cr+₹54.3 L (10.8%)Rejected-AOC | ₹5.6 Cr+₹54.3 L (10.8%) | L-3 | Rejected-AOC Not found L-1 |
| 4 | L-4₹5.6 Cr+₹55.6 L (11.1%)Rejected-AOC 825 GANDHI CHOWK RANIKHET 263645 DISTRICT ALMORA | RANIKHET | ALMORA | UTTARAKHAND | 263645 | ₹5.6 Cr+₹55.6 L (11.1%) | L-4 | Rejected-AOC Not found L-1 |
| 5 | L-5₹5.8 Cr+₹75.6 L (15.0%)Rejected-AOC CT PUBLIC SCHOOL PHAYAL KHASARA NO 597 JAKHOO MOHAL PHAIL SHIMLA HP | SHIMLA | HIMACHAL PRADESH | 170009 | ₹5.8 Cr+₹75.6 L (15.0%) | L-5 | Rejected-AOC Not found L-1 |
Tender Value
₹5.9 Cr
EMD Value
₹6.2 L
Closing Date
11 Nov 2021, 11:00 amClosed
Executive Engineer Jal Shakti Divn No.1 Una HP
Executive Engineer Jal Shakti Divn No.1 Una HP
SH Providing , Laying jointing and testing of GMSERW / GMS pipe in Rising mains, Supply and Erection of Pumping machinery and Construction of Civil work.
2021_HPIPH_53147_1
No. JSV-1/TA/E-tender/ 21-10192-10221 dt 27-10-21
Open Tender
Civil Works
Item Rate
180 days
PGI SATELLITE CENTRE at Malahat
as per NIT
11 documents required · 11 mandatory
₹2,500
Executive Engineer Jal Shakti Divn No.1 Una HP
₹6.2 L
Distt Hamirpur Zone
10 Feb 2022
28 Oct 2021
11 Nov 2021
28 Oct 2021
11 Nov 2021
28 Oct 2021
28 Oct 2021 - 11 Nov 2021
8 Nov 2021
Amount
Excavation in foundation and trenches up to all depths and in all classification of earth work such as Pick work, Jumper work, chiselling or wedging out of soft and hard rock as blasting is prohibited, saturated soil including bailing or pumping out of water, including cutting of bitumenous/concrete surface wherever required, in all lifts including trimming and dressing of sides, levelling of beds to correct grade including shoring, strutting , planking, timbering and dewatering where ever required. Stacking usable and unusable material /soil seperataly and after laying, jointing and testing of pipes (for pipes, Pipe duct, chambers, x-sings etc.), returning the usable soil in 15cm layers by ramming and watering and then disposing of all surplus excavated soil/ unusable material as directed within all leads/ lifts and including cost of diversion for traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects within all leads and lifts as per direction of the Engineer-in-charge.
Pdg, Laying,Jointing and Testing in trenches Galvanized mild steel flanged/butt welded pipe of below mentioned dia and grade conforming to IS 1239-2004 (with latest ammendments The M.S. flanges are to be provided 1% of total joints as per table below conforming to 6392-1971 ( Latest uptodate ammendments) and welding of M.S. flanges with pipe as per IS: 816-1965 with electrode as per IS: 814-1967 including required Nos. and size of M.S. nuts and bolts as per IS: 1369-1967 and compressed asbestos fibre jointing gaskets sheet not less than 3mm thick as per IS: 27121-1965. The welding of flanges to be done on both faces in three layers in each face to make the joints leak proof including all kind of specials such as bends of all degree to be made from parent tube, short pieces, tail pieces all made from parent tube and to the entire satisfaction of enginer-in-charge. The pipes end should be bevelled suitable for butt welding. The circumferencial butt welded joints ( 99% of the total joints) by electrical arc welding to following dia & class pipes,welding of pipes to be done in three layers to make the joints leak proof and to achieve the minimum effective throat thickness of weld conforming to IS- 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani oerlikon (Adore)-CITOJET/ESAB make, conforming to IS 814-1991, at site of work complete in all respects and including DPT test for joints & manual/mechnical handing of pipes. The laying of pipe shall confirm to BIS-5822 (with latest ammendments uptodate), including all kind of specials such as bends of all degree to be made from parent tube, short pieces, tail pieces all made from parent tube within all leads and lifts. ( Earth work in trenches, M.S. flanges and butt welded joints to be measured and paid for separately)
150mm dia GMS (H) IS 1239-2004 T/well No. 1 to collection tank
150mm dia GMS (H) IS 1239-2004 T/well No. 2 to collection tank
150mm dia GMS (H) IS 1239-2004 T/well No. 3 to collection tank
Providing, laying, jointing and testing in trenches of galvanized MSERW flanged pipes excluding cost of flanged bends of all degrees conforming to IS/ISO 3183-2007 Grade L210 or A as per dimensions weight and test pressure mentioned below in a random length of 4m - 6m, The M.S. flanges are to be provided 1% of total joints as per table below conforming to IS: 6392-1971 (latest upto date amendments) and welding of flanges with pipes as per IS: 816-1965 with a electrode as per IS: 814-1967 including required Nos. and size of M.S. nut and bolts as per IS: 1369-1967 and compressed asbestos fiber jointing gaskets sheet not less than 3mm thick sas per IS: 2712-1965 & 99% butt welded joints by considering minimum three layers. The welding of flanges to be done on both faces in two layers on outer face + one layer on inner face to make the joints leak proof and to the entire satisfaction of the Engineer-in-charge. The laying of pipes should be conformed to IS: 5822-1994 (earth work in trenches, MS flanges and butt welded joint to be measured and paid for seprately) . The pipe shall have zinc coating as per IS:4736 in factory latest with upto date ammendements.
200 mm dia 5.6mm thick GMSERW Pipe "L210 or A" IS/ISO 3183-2007 RD 0 to 2280
200 mm dia 4.8mm thick GMSERW Pipe "L210 or A" IS/ISO 3183-2007 RD 2280 to 8310
Providing and welding M.S. flanges @1% at suitable point, conforming to following tables as per IS: 6392-1971 (Latest with upto date amendments) with plain end GMS/MSERW pipe in requsite number of layers on both faces to make the joint leak proof (The cost of providing and laying of MSERW pipes to be measured and paid for seprately). The welding of flanges should conform to IS:816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364. including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00 mm conforming to IS 2712-1998. The work shall be done to the entire satifaction of engineer in charge with in all leads and lifts.tion of Engineer-in-Charge.
150mm dia T-5 (T/well No. 2 to collection tank)
150mm dia T-5 (T/well No. 3 to collection tank)
200mm dia T-28 (Collection tank to storage tank)
200mm dia T-17 (Collection tank to storage tank)
200mm dia T-5 (Collection tank to storage tank)
Providing circumferential butt welded joints @99% by electrical arc welding to GMS pipe, welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5mm to 6.3mm of Advani Oerilikon (Adore)-CITOJET/ES/ESAB make,conforming to IS 814-1991, include Die pentration test,at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
150mm dia GMS pipe (T/well No. 1 to collection tank)
150mm dia GMS pipe (T/well No. 2 to collection tank)
150mm dia GMS pipe (T/well No. 3 to collection tank)
200mm dia GMSERW pipe (Collection tank to storage tank)
Providing double flanged Cast Steel Non Return Valve 21 kg/cm2 normal seart pressure , following class of RG / Leader / Krloskar / Suchdeva / LP / Kartar / and any other approved make for rising main and capable of with standing following normal seat pressure conforming to BS:1868/API-300 or latest ammendments.
200mm dia Class ASA- 150
Providing and fixing screwed type cast iron air valve of 25 mm dia (single ball type) of Leader / Krloskar / Suchdeva / LP / Kartar / and any other approved make confirming to BS : 1452-90 with upto date amendments as per class PN-10.00 to withstand a seat pressure 11.22 Kg/ cm2 in rising main.
T/well No.1 Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Sabar/ Seerex /Johnston / Amrut/ lubi/ Hindustan/Groundfos confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable ,errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge, (Q) 17.36 LPS
Total Head ( H )32.26 Mts.
a) SWL in Tubewell =0.00 Mtr. bgl.
c) R.L. point of discharge = 301.96Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. 9.0 Mtrs.
e) Drawdown in Tubewell 16.77 Mtrs.
f) R.L of lowest point of pumpset installation = 273.69 Mtrs.
g) Static Column lift = 27.83 Mtrs.
Rising main. Column Pipe.
Length 30 Mtrs. Length 35.77 mtrr.
Dia meter 150 mm Dia 125 mm
Class GMS ( M) Class GMS. (M)
Pumping hours 8 hours
Altitude of installations above M.S.L. __________mtr.
Characteristic of water.
a) Temperature _______ Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well mtr.
Dia of T/ well assembly 200 mm.
Length of assembly pipe.
Dia of housing pipe 300 mm.
Length of housing pipe
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing: Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation :Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Drive Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Deliver size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells /Standard/ Kilburn Siemens make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. .
a) MCB of kilburn / L&T/ Havells/Standard make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments.
ii) ELCB of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault.
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition )
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including.
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments.
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB.
Providing suitable oil immeresed star delta starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments.
Providing and fixing double flanged Cast Iron Sliuce valve of Leader / Krloskar / Suchdeva / LP / Kartar / and any other approved make for the Column pipe of pump and capable of withstanding the normal seat pressure and as per IS 780-1992 with latest ammendments Class PN 1.00 For Column Pipe 125 mm dia Sluice valve
Providing and fixing double flanged Cast Iron Reflux valve of Leader / Krloskar / Suchdeva / LP / Kartar / and any other approved make having by pass arrangement on the delivery line of pump and capable of withstanding the normal seat pressure and as per IS 6312-1984 P-I with latest ammendments 150 mm dia
Providing and fixing pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements
Supply of PVC jointless,flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havelles/Finolex make suitable for the pumpsets offered from OCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor.The type, size and make shall be subject to approval of HPSEB authorities.
Pdg & lowering of GMS Column pipe for assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber / asbestos gasket of min.3 mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 .The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.5 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main .The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2 Each) at the top of T/well assembly, and as per the direction of Engineer - in - Charge.( The pipe shall be supplied by the department free of cost from Divisional store Malahat )
Installation of all items appearing at S.No 8 to 24 as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor.
Providing and fixing double loop earthing with GI plate of 20x3 mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt 25x5 mm strip as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge.
T/well No.2 Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Sabar/ Seerex /Johnston / Amrut/ lubi/ Hindustan/Groundfos confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable ,errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge, (Q) 17.36 LPS
Total Head ( H ) 37.71 Mts.
a) SWL in Tubewell =0.00 Mtr. bgl.
c) R.L. point of discharge = 301.96Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. 9.0 Mtrs.
e) Drawdown in Tubewell 16.77 Mtrs.
f) R.L of lowest point of pumpset installation = 274.13 Mtrs.
g) Static Column lift = 27.83 Mtrs.
Rising main. Column Pipe.
Length 500 Mtrs. Length 35.77 mtrr.
Dia meter 150 mm Dia 125 mm
Class GMS ( M) Class GMS. (M)
Pumping hours 8 hours
Altitude of installations above M.S.L. __________mtr.
Characteristic of water.
a) Temperature _______ Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well mtr.
Dia of T/ well assembly 200 mm.
Length of assembly pipe.
Dia of housing pipe 300 mm.
Length of housing pipe
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing: Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation :Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Drive Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Deliver size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells /Standard/ Kilburn Siemens make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. .
a) MCB of kilburn / L&T/ Havells/Standard make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments.
ii) ELCB of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault.
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition )
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including.
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments.
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB.
Providing suitable oil immeresed star delta starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments.
Providing and fixing double flanged Cast Iron Sliuce valve of Leader / Krloskar / Suchdeva / LP / Kartar / and any other approved make for the Column pipe of pump and capable of withstanding the normal seat pressure and as per IS 780-1992 with latest ammendments Class PN 1.00 For Column Pipe 125 mm dia
Providing and fixing double flanged Cast Iron Reflux valve of Leader / Krloskar / Suchdeva / LP / Kartar / and any other approved make having by pass arrangement on the delivery line of pump and capable of withstanding the normal seat pressure and as per IS 6312-1984 P-I with latest ammendments 150 mm dia
Providing and fixing pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements
Supply of PVC jointless,flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havelles/Finolex make suitable for the pumpsets offered from OCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor.The type, size and make shall be subject to approval of HPSEB authorities.
Pdg and lowering of GMS Column pipe for assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber / asbestos gasket of min.3 mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 .The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.5 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main .The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2 Each) at the top of T/well assembly, and as per the direction of Engineer - in - Charge.( The pipe shall be supplied by the department free of cost from Divisional store Malahat )
Installation of all items appearing at S.No 28 to 44 as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor.
Providing and fixing double loop earthing with GI plate of 20x3 mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt 25x5 mm strip as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge.
T/well No.3 Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Sabar/ Seerex /Johnston / Amrut/ lubi/ Hindustan/Groundfos confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable ,errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge, (Q) 17.36 LPS
Total Head ( H ) 40.14 Mts.
a) SWL in Tubewell =0.00 Mtr. bgl.
c) R.L. point of discharge = 301.96Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. 9.0 Mtrs.
e) Drawdown in Tubewell 16.77 Mtrs.
f) R.L of lowest point of pumpset installation = 274.21 Mtrs.
g) Static Column lift = 27.83 Mtrs.
Rising main. Column Pipe.
Length 700 Mtrs. Length 35.77 mtrr.
Dia meter 150 mm Dia 125 mm
Class GMS ( M) Class GMS. (M)
Pumping hours 8 hours
Altitude of installations above M.S.L. __________mtr.
Characteristic of water.
a) Temperature _______ Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well mtr.
Dia of T/ well assembly 200 mm.
Length of assembly pipe.
Dia of housing pipe 300 mm.
Length of housing pipe
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing: Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation :Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Drive Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Deliver size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells /Standard/ Kilburn Siemens make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. .
a) MCB of kilburn / L&T/ Havells/Standard make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments.
ii) ELCB of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault.
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition )
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including.
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments.
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB.
Providing suitable oil immeresed star delta starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments.
Providing and fixing double flanged Cast Iron Sluice valve of Leader / Krloskar / Suchdeva / LP / Kartar / and any other approved make for the Column pipe of pump and capable of withstanding the normal seat pressure and as per IS 780-1992 with latest ammendments Class PN 1.00 For Column Pipe 125 mm dia
Providing and fixing double flanged Cast Iron Reflux valve of Leader / Krloskar / Suchdeva / LP / Kartar / and any other approved make having by pass arrangement on the delivery line of pump and capable of withstanding the normal seat pressure and as per IS 6312-1984 P-I with latest ammendments 150 mm dia
Providing and fixing pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements
Supply of PVC jointless,flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havelles/Finolex make suitable for the pumpsets offered from OCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor.The type, size and make shall be subject to approval of HPSEB authorities.
Pdg & lowering of GMS Column pipe for assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber / asbestos gasket of min.3 mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 .The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.5 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main .The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2 Each) at the top of T/well assembly, and as per the direction of Engineer - in - Charge.( The pipe shall be supplied by the department free of cost from Divisional store Malahat )
Installation of all items appearing at S.No 48 to 64 as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor.
Providing and fixing double loop earthing with GI plate of 20x3 mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt 25x5 mm strip as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge.
Collection tank to storage tank: Providing horizontal spindle, horizontal / radial split casing /end suction ( back pull out arrange-ment) Single /double /multi stage of Kirloskar / KSB Crupton KSB/Calama/BS/ Groundfos/ Hindustan/ Lubbi make as per BIS IS 1520-1980 with upto date ammendments read with IS: 9137-1978 or latest edition suitable for lifting water for under mentioned characteristic with Bronze impellers / priming funnels, casing ring and shaft sleeves of Bronze shaft of stainless steel with cast iron casing, coupled directly through a flexible coupling on a common cast iron / cast steel base plate (base plate to be framed from the manufacturers of the pumping unit only) to slipring / Squirrel cage screen protected drip proof induction motor / motors of standard make such as Crompton / NGEF / GEC / Seimens /Jyoti/ Kirloskar BHEL / ABB suitable for operation on 415 (+/-15%) volts. 50 Cycles /Sec. 3 phase AC electric supply of 2900 RPM.The power of electric motor/ motors should be at least +10% in excess of the maximum power required by the pump / pumps in the Operation range of (+10%) and (-15%) of the duty point head. The motor / motors as per IS 325 IS -1978 with upto date amendments read with IS 900 -1972. It should include cost of Bearing. Nuts, Bolts and painting etc. and should meet the following requirements.
Discharge =( Q) 17.36 LPS
Total Head = ( H) 197.33 Mts.
a) LWL In clear water Tank = 299.96 mtr
b) R.L. of shaft = 299.96 Mtrs.
c) R.L. of discharge Point. =401.30 mtrs.
d) Suction lift. +tive mtrs.
e) Discharge Head =401.30 mtrs.
f) Static Head = 101.34 mtrs.
Rising main.
Length = 8310 mtrs.
Diameter = 200mm. Dia GMSERW pipe
Class GMS Tube (MG)
Pumping hours. 8 hours.
Altitude of installations above M.S.L 407 mtrs.
Characteristic of Water
a)Temperature ___20_____Deg.Col.
b)Turbidity ________ JTU
c) Alloanity _________ mg/1 ca Co3
d)Size of solids __________ mm
e) Others.
(a) Pumps: Specifications:
i)Make
ii)Model.
iii)No.of stages:-
iv)Manufacturers
certificate to be attached.
Performance
i)Discharge:-
ii)Total Head:-
iii)B.H.P.
iv)Efficiency:
vi)Performance Curve to be attached.
b)Motors: Specifications.
i)Make
ii)Model
iii)Rating
iv)Speed.
v)Insulation.
(C) Coupling:
(d) Base Plate.
Providing ICTP Main Switch with HRC fuses of L&T/ Havells/ Standard / Kilburn / Siemens make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board i/c angle iron post of suitable height & size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising & capable of mounting the following accessories with all internal connections.
OCB of kilburn / L&T / Havells / Standard make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments.
ELCB/ELR of recommended make L&T Havells / Standard / Kilburn as per IS ;2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault.
The Voltage Monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage, reverse phasing, overloading and phase voltage difference as per IS; 3842 ( Latest Edition )
Power factor meter of standard make as per relevent IS code with upto date ammendments.
Frequency meter of standard make as per relevent IS code with upto date ammendments.
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments.
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments.
Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB.
Providing suitable starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments.
Providing & fixing double flanged Cast Iron Sluice valve of Leader / Krloskar / Suchdeva / LP / Kartar / and any other approved make of 200 mm dia for suction pipe of pump and capable of with standing normal Seat Pressure as per IS 14846 with upto date ammendments. Class PN 1.00
Providing and fixing double flanged Cast Iron Sluice valve of Leader / Krloskar / Suchdeva / LP / Kartar / and any other approved make of 150 mm dia for the delivery line of pump and capable of with standing normal Seat Pressure as per IS 14846 with upto date ammendments. Class PN 1.00
Providing double flanged swing type cast iron Reflux Valve of Leader / Krloskar / Suchdeva / LP / Kartar / and any other approved make of 150 mm dia having Bye pass arrangement on the delivery line of the of the Pump and capable of withstanding normal Seat Pressure as per IS :5312-1984 (P-I) (Cast Iron) with latest ammendments
Providing double flanged swing type cast iron Reflux Valve of Leader / Krloskar / Suchdeva / LP / Kartar / and any other approved make of 200 mm dia having Bye pass arrangement on the Rising Main of the Pump and capable of withstanding normal Seat Pressure as per IS :5312-1984 (P-I) (Cast Iron) with latest ammendments
Providing and fixing circular dial pressure gauge of Precision / Fiebig make complete with all accessories such as stop cock,Copper tubing etc.as per IS: 3624-1987 with upto date ammendments.
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and Fixing double flanged GMS/GMSERW piping work ( Layout to be approved by Engineer-in-Charge). for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as bends,Tees, Reducers / Inceasers with companion flanges matching with the relevant specifications of the accessories as indicated in the Drawing including rubber / asbestos gasket of 3 mm thickness as per IS : 2712-1972 and required number of Nuts and Bolts as per 1364-1983.-the pipes shall be as per relevent IS code and to withstand 1.50 times total head.
i) Suction Pipe 200 mm dia.
ii) Delivery Pipe 150 mm dia.
iii) Common Header 200 mm dia. and will extend upto 5 metres from the outer wall of the pump house in the direction of Rising main of 200 mm dia to be joined.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor.
Providing and fixing double loop earthing with GI plate of 600x600x6.30mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge.
Civil work (C/O of Pump house cum attendant room, boundary wall , toilet, 2Nos. Single room Pump Houses, collection tank 2,00,000 lirs cap, 2Nos. Storage tank 3,50,000 ltrs cap each , internal wiring of pump houses and automation).
Providing and laying Cement Concrete 1:6:12 ( 1 cement : 6 sand : 12 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts and as per the direction of the .Engineer-in-Chaarge.
Providing and laying Cement Concrete 1: 3: 6 ( 1 cement : 3sand: 6 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts and as per the direction of the .Engineer-in-Chaarge.
Ist class brick work using common burnt clay building bricks of appraoved quality in foundation and plinth in cement mortar 1:6 (1cement:6sand) in all leads and lift to the entire satisfaction of Engineer-in-charge.
Ist class brick work using common burnt clay building bricks of approved quality in super structure in cement mortar 1:6(1cement:6sand) in all leads and lift to the entire satisfaction of Engineer-in-charge.
Half brick work using common burnt clay building bricks in super structure in cement mortar 1 : 4 ( 1 cement :4 sand) of 1st Class bricks complete in all lead and lifts as per the direction of the Engineer-in-Charge.
Boulder filling under floor dry hand packed tightly in all leads and lift to the entire satisfaction of Engineer-in-charge in foundation and plinths in all leads and lift to the entire satisfaction of Engineer-in-charge.
Providing form work with steel plate 3.15 mm thick welded with angle iron frame 30x30x5mm so as give a fair finish including centring, shuttering, strutting and propping etc with wooden battens and ballies, height of propping and centring below supporting floor to ceiling upto any height and removal of the same for in site-reinforced concrete and plain concrete work in
Foundation,footing & bases of columns and the like mass concrete with in all leads and lifts complete in all respect.
Square, rectangular or polygonal in plan with in all leads and lifts complete in all respect.
Circular in plan with in all leads and lifts complete in all respect.
Beams,cantilivers,girders and lintels sides and soffits of beams,beam haunchings, cantilivers , girders, bressumers with in all leads and lifts complete in all respect.
Flat surfaces such as soffits of suspended floors,roofs,landing and the like floor etc. up to 20 mm in thickness including all leads and lifts complete in all respect.
Edges of slab and breaks in floors and walls under 20 cm wide including all leads and lifts complete in all respect.
Vertical surfaces such as walls (any thickness) partitions and the like i/c attached pillasres buttresses, plinth & string courses and the like including all leads and lifts complete in all respect.
Providing of form work of ordinary timber planking so as to give a rough finish including centering, shuttering , strutting and propping etc. height of propping and centering below supporting floor to ceiling and removal of the same insitu reinforced concrete and plain concrete work in all leads and lifts and as per the direction of the Engineer- in - Charge.Arches beyond 6.00 mts.span
Providing and laying cement concrete using M - 30 concrete mix (not less than 1:1.5:3) with graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :
Suspended floor roofs, landing and shelves and their support balconies, beam girderes bressumers and cantiliver.
Foundation,footing & bases of columns and the like mass concrete with in all leads and lifts complete in all respect as per the direction of the Engineer-in-charge.
Wall (any thickness,but not less than 0.10 mtr.thickness) attached pilasters,buttresses,plinth & string courses etc. upto all heights complete within all leads and lifts as per the direction of the Engineer-in-charge.
Arches upto all heights complete within all leads and lifts as per the direction of the Engineer-in-charge.
Providing and laying cement concrete 1:2:4 ( 1cement:2 sand: 4graded stone aggregate 20 mm nominal size ) and curing complete excluding the cost of form work and reingorcement for reinforced concrete work in:-
Foundation footings bases of columns and the like and mass concrete in all leads and lifts and as per the direction of the Engineer-in-Charge.
Square or rectangalar in Plan in all leads and lifts and as per the direction of the Engineer-in-Charge.
Circular in plan in all leads and lifts and as per the direction of the Engineer-in-Charge.
Suspended floor roofs, landing and shelves and their support balconies, beam girderes bressumers and cantiliver upto all heights in all leads and lifts and as per the direction of the Engineer-in-Charge.
Providing Tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete in all respect in all leads and lifts & as per direction of the Engineer-in-Charge
Providing and fixing pressed steel doors frames manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges, jump lock jamb, beed and if required angle threshold of mild steel angle of section 50X25 mm or base ties of 1.25 mm pressed mild steel welded or regidly fixed together by mechanical means, adjustable lugs with split and tails to each jamb including steel but things 2.5 mm thick with gaurds, lock strike plate and shock as specified and applying a coat of approved steel primer after pretreatment of the surface as directed by Engineer-in-charge.
Profile-A
Profile-B
Providing and fixing, panelled glazed or panelled & glazed shutter for doors, windows & clearstory windows including bright finished black enamelled from butt hings with necessary screw in all leads and lift to the entire satisfaction of Engineer-in-charge. 2nd class deodar wood 40mm thick.
Providing and fixing MS grill of required pattern in wooden frames / pressed steel frames of windows etc. with M.S. Flat square or rounded bar 12mm dia round headed bolts and nuts or by screws and or square bars, ruled spacing to wooden frames windows and clearstory windows etc within all leads and lifts as per direction of Engineer-in-charge.
Providing and laying cement concrete flooring 1:2:4(1cement:2sand:4graded stone agg., 20mm nominal size) laid in one layer finished with a floating coat of neat cement within all leads and lifts as per direction of Engineer-in-charge. 40mm thick
6mm cement plaster to ceiling in CM 1:3 ( 1Cement :3 Sand) in all leads and lifts and as per the direction of the Engineer-in-Charge.
15 mm cement plaster in single coat on rough side of brick masonry for interior plastering upto floor two level including arrises, internal rounded angle, chamfers and or rounded angles not exceeding 80 mm in girth and finished even and smooth with cement mortor 1:6 ( 1 cement :6 sand ) in all leads and lifts as per the direction of the Enginner-in-Charge.
Pointing on brick work with cement mortor 1:3 (1cement : 3 sand) Raised and cut in all leads and lifts and as per the direction of the Engineer-in-Charge.
Providing RCC work smooth finishing of the exposed surface with cement mortor1:3(1cement:3 sand ) in all leads and lifts and as per the direction of the Engineer-in-Charge.
White washing with lime on undecorated wall surfaces two coats to give an even shade including thoroughly brooming the surface to remove all dirt , dust and other foreign matters in all leads and lifts and as per the direction of the Engineer-in-Charge.
Hirmachi colour wash on undecorated wall surfaces (Three coats) to give an even shade including thoroughly brooming the surfaces to remove all dirt,dust, mortar drops and other foreign matter complete in in all respect as per the direction of the Engineer-in-Charge.
Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on undecorated wall surfaces to give an even shade sand papered smooth in all leads and lifts and as per the direction of the Engineer-in-Charge.
Applying priming coat on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,greese,dirt and other foreign matters,sand papering and knotting.Ready mixed paint brushing wood primer pink in all leads and lifts and as per the direction of the Engineer-in-Charge.
Painting two coats (excluding priming coat) on new wood and wood based surfaces,with enamel paint to give an even shade including cleaningthe surface of dirt ,dust and other foreign matters sand papering and stopping with enamel paint other than white in all leads and lifts and as per the direction of the Engineer-in-Charge.
Applying priming coat over new steel and other metal surfaces after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign metter and scoured with wire brushes fine steel wool scrapers and sand paper complete with ready mixed priming paint brushing red lead, red-oxide/ zinc oxcide chrome.in all respect as per the direction of the Engineer-in-Charge.
Painting two coats (excluding priming coat) on new steel and other metal surfaces with enamel paint to give an even shade including cleaning the surface of dirt ,dust and other foreign matter with enamel with enamel paint other than white complete in all respect as per the direction of the Engineer-in-Charge.
Providing and fixing anodised M.S. sliding door bolts with bolts and nuts screws etc in all leads and lifts and as per the direction of the Engineer-in-Charge.
Providing and fixing anodised MS tower bolts ( barrel type) with screws etc. in all leads and lifts and as per the direction of the Engineer-in-Charge
Providing ad fixing anodised MS handles with necessary screws etc. in all leads and lifts and as per the direction of the Engineer-in-Charge. 125 mm
Providing and fixing MS Hooks and eyes in all leads and lifts and as per the direction of the Engineer-in-Charge.250 mm.
Providing plinth protection 50mm thick cement concrete 1:3:6(1cement:3asand:6graded stone agg., 40mm nominal size) including finishing the top surface concrete smooth within all leads and lifts as per direction of Engineer-in-charge.
Proving under layer for plinth protection of 75 mm thick (unconsolidated) bed dry brick / stone Aggregate 40 mm nominal size will rammed with rammed and consolidated and grouted with fine sand including preparation of ground within all leads and lifts as per direction of Engineer-in-charge.
White glazed tiles 6 mm thick in flooring cement mortar 1:3 (1cement : 3 sand) finished with flush pointing in white cement within all leads and lifts as per direction of Engineer-in-charge.
White glazed tiles 6 mm thick in Skirting with neat cement finished with flush pointing in white cement within all leads and lifts as per direction of Engineer-in-charge.
Steel work welded in built up sections,trusses and framed work including cutting hoisting fixing in position and applying a priming coat of red lead paint in all lead and lifts as per the direction of the Engineer-in-Charge.
Providing & fixing 0.60 mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 micron over 5 micron primer coating to back coat of polyster of 5 micron over 5 micron primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm diameter s with prepainted limpet rubber washers complete with all accessories as required within all lead and lifts as per the direction of the Engineer-in-Charge.
Providing ridges or hips 60cm over all in plinth with galvanised iron G.I. sheet fixed J or L hooks bolts and nuts 8mm dia G.I limpet and bitumen washers complete within all lead and lifts as per the direction of the Engineer-in-Charge.
Providing valley 90cm over all in plain G.I. sheets fixed with galvanised iron J or L hooks bolts and nuts 8mm dia G.I. limpet and bitumen washers complete within all lead and lifts as per the direction of the Engineer-in-Charge.
Excavation in earth work and filling in 15 cm. layers in foundation & plinths including ramming, watering and consolidating complete in all respect including carriage of materials within all leads and lifts and as per the direction of the Engineer-in-Charge.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surface (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt & remains of loose powdered materials complete within all lead and lifts as per the direction of the Engineer-in-Charge.
Providing and laying Damp proof course 38 mm thick cement concrete 1:2:4 (1 Cement : 2 sand:4 graded stone aggregate 12.50 mm nominal size ) in all leads and lifts and as per the direction of the Engineer-in -Charge.
Applying a coat of hot bitumen ( Mexphalt 80/100 of equivalent ) using 1.70 Kg/sqmtrs. On damp proof course after cleaning the surface with a piece of cloth lightly soaked with kerosene oil within all lead and lifts as per the direction of the Engineer-in-Charge.
Providing and fixing of angle iron door, window, clerestory windows manufactured from MS angle iron section of 40x40x6mm thickness including hinges jamb, lock, jamb, bead and if required angle threshold of mild steel angle 50x25 mm welded or rigidly welded by mechanical means, lungs withsplit end tail to each jamb i/c. steel butt hinges 2.5 mm thick with provision for locking arrangement & shock observer as specified & applying a coat of approved steel primer after pretreatment of furface within all lead and lifts as per the direction of the Engineer-in-Charge.
Providing and fixing of 1 mm thick MS Sheet garage door with frame of 40x40x6mm angle iron 3.15 mm gusset plates at the junctions and corners, all necessary fitting complete including applying a priming coat of red lead paint using flats 30x5mm for diagonal braces and central cross pieces complete within all lead and lifts as per the direction of the Engineer-in-Charge..
Providing 40x3mm flat iron hold fast 40 cms long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15 cms 1:3:6 ( 1 cement :3 sand : 6 graded stone aggregate 20 mm nominal size ) complete in all respect as per the direction of the Engineer -in- Charge.
Providing / fixing vitreous china water closet squatting pan ( Indian type WC pan ) size 580 mm ( Earth work, bed concrete, foot rest and trap to be measured and paid for seperately Orissa pattern.
Providing / fixing of PVC "P" Trap complete within all lead and lifts as per the direction of the Engineer-in-Charge.
Providing / fixing of PVC bend 50 mm dia complete within all lead and lifts as per the direction of the Engineer-in-Charge.
Providing / fixing of PVC waste pipe and ventilating pipes within all lead and lifts as per the direction of the Engineer-in-Charge. 100 mm dia
Providing / fixing of PVC waste pipe and ventilating pipes complete within all lead and lifts as per the direction of the Engineer-in-Charge. 50 mm dia
Providing / fixing of wall ceiling and floor galvanized MS tube (Light) tube fitting and clamps including making good the wall ceiling and floor 15 mm thick within all lead and lifts as per the direction of the Engineer-in-Charge.
Providing / fixing of CP brass bib cock with capstan head 15 mm dia complete within all lead and lifts as per the direction of the Engineer-in-Charge.
Providing / fixing of CC Hume pipes each 750 mm dia 1200 mm lo9ng required for excavation at site complete within all lead and lifts as per the direction of the Engineer-in-Charge.
Providing / fixing of 10.00/12.50/15.00 litres vitreous china low level flushing cistern with a pair of C.I. or mild steel brackets, complete with fitting such as lead valves less syphon, 15 mm nominal size brass ball valves with polygthene float. C.P. Brass handles unions and coupling for connections with inlet, outlet and over flow pipes , 40 mm dia C.P. flush bend including cutting holes in walls and making good the same and connecting the flush bend with cistern and closet ( Overflow) pipe to be measured and paid for seperately complete within all lead and lifts as per the direction of the Engineer-in-Charge..
P/F MS fan clamps type 1 of 16 mm dia bar bent to shape with hooked ends in RCC slab during laying including painting the exposed portion of roof as per standard design complete within all lead and lifts as per the direction of the Engineer-in-Charge..
Pdg, Laying jointing and testing in trenches GMS Tubes (L/M class) tube fitting (Earth work in trenches to be measured & paid for separatly) 100mm dia complete within all lead and lifts as per the direction of the Engineer-in-Charge..
Providing and fixing C.I.sluice valve ( With hand whell ) of Leader / Krloskar / Suchdeva / LP / Kartar / and any other approved make as per IS 780 class for following dia ( including brass spindle and as per IS 2906 class-II including MS Flange, bolts, nuts, rubber insertion etc. complete in all respect i/c carriage of material within all leads and lifts.100mm dia complete within all lead and lifts as per the direction of the Engineer-in-Charge.
Constructing chamber for sluice valve, with CI surface box 100 mm top dia.,160 mm bottom dia. & 180 mm deep(inside) with chained lid RCC top 1:2:4 mix (1 cement :2 sand :4 graded stone aggregate 20 mm nominal size) 100 mm thick foundation concrete 1:5:10 mix (1cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) & inside plastering with cement mortor 1 :3 (1 cement : 3 sand) finished with a floating coat of neat cement i/c curing complete. 600 x 600 x 750 mm inside size With 150 mm thick walls of RCC 1:2 :4 (1 cement :2 sand :4 graded stone aggregate 20mm nominal size) complete with form work & reinforcement with 6 mm bars at not exceeding 150 mm centres both ways complete within all lead and lifts as per the direction of the Engineer-in-Charge.
Prov. & fixing SFRC Man hole cover with frame having frames size of 560 mm internal dia.should not be less than 100 kg complete within all lead and lifts as per the direction of the Engineer-in-Charge..
Wiring for light/Fan point/Exhaust fan point/call bell point with 1.5 Sq.mm PVC insulated copper conductor cable in surface/recessed PVC conduct at required including carriage of all material within all leads and lifts. Group "C"
Wiring for light/power plug with 2 x 4 Sq.mm PVC insulated copper conductor or single core cable in surface/recessed steel conduit alongwith 1 No. 2.24 mm dia bare copper wire for loop earthing as required including carriage of materials within all leads and lifts.
Wiring for circuit wiring with 2 x 2.5 Sq.mm PVC insulated copper conductor single core cable in surface/ recessed steel conduit as required including carriage of material within all leads and lifts.
Wiring for sub-main wiring with the following size of copper conductor single core cable in surface/recessed steel conduit as required i/c carriage of materials upto all leads and lifts. 2x6 Sq.mm
Supplying and fixing metal box of 180 x 100 x 60mm deep (Nominal size) on surface/recess with suitable size phonolic leminated sheet cover fixing 3 pin 15/16 amps socket tumber/piano type switch connections painting etc. including carriage of materials within all leads and lifts.
Supplying and fixing metal box of 180 x 100 x 60mm deep (Nominal size) on surface/recess with suitable size phonolic leminated sheet cover fixing 3 pin 5/6 amps socket tumber/piano type switch connections painting etc. including carriage of materials within all leads and lifts.
Supplying and fixing backellite batten/angle holder including connection as required.
Providing, installing, testing and commissioning of ceiling fan and regulator including wiring the rod of standard length (upto 30cm) with 1.5 Sqmm PVC insulated copper conductor single core cabe etc. as required sweep type.
Category "A".
Category "B".
Providing, installation, testing and commissioning of prewired flourscent tube fitting complete with ballast, starter and capactors but excluding flourscent tube rod, suitable to operate on 230 volts single phase A.C.supply directly on surface with copper wiring as required including carriage of materials within all leads and lifts tube fixture 1 x 36 watt Box type Category "A".
Supplying and fixing 40 Amps to 63 Amps rating 240 Volts "L" series miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including carriage of material within all leads and lifts. Category- A, 63 Amps.
Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recessed completed with tinned, copper busher neutral link, earth bar, detachable gland plate inter -connections, including painting, earthing etc. as required Bus bar
Supplying and fixing 5 Amps to 32 Amps rating 240 volts, G series miniature circuit breaker of following poles in the existing MCB, DB complete with connections testing and commissioning etc. as required Category "A", single pole.
Earthing with G.I. pipe earth, pipe 4.5 mtrs length, 40mm dia including accessories and providing masonry enclousres with cover plate having locking arrangement and watering pipe etc.( but without charcal coke and salt) complete as required including carriage of materials within all leads and lifts.
Extra using salt and charcoal for pipe earth electrode as required, including carriage of materials within all leads and lifts.
Supplying and laying 6 Sqmm G.I.wire at 0.50 mtr below ground level for conductor earth electrode, including soldering etc. as required including carriage of materials within all leads and lifts.
Providing, fixing & testing Street Light Fixture with CFL of 36 watt, copper ballast, G.I. Pipe bracket, complete in all respects.
Supplying and fixing of integral CFL Post Top Lantern of following capacity, cast aluminium spigot, spun aluminium canopy, opal acrylic diffuser, complete with all accessories but excluding CFL lamp including making connections,testing etc. as required. 2x18 Watt
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured / XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:-
Armoured cable 4 sq. mm (twin core)
Armoured cable 6 sq. mm (twin core)
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB),having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. RCCB 63 Amps. Cat-A.
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages,connections, testing and commissioning etc. as required:-
Exhaust Fan, Heavy duty, 300 mm sweep
Exhaust Fan, Heavy duty, 600 mm sweep
Providing and fixing of Street Light Aqua Roadway Lumairies " WAVE" (IP-66) single pole peice, pressure die cast aluminium housing top opening luminaries ( IP-66) with all accessories i/c cost of lamp ISI Mark BGWRLL-150-SV FG PDC make complet with all accessories and balast i.e 15/16 Amp Switch and socket with board copper wire 8 SWG ( 4mm dia ) bracket and suitable angle lamps for fixing and other fittings etc complete in all respects.
Providing, fixing & testing Street Light Fixture with CFL of 36 watt, copper ballast, G.I. Pipe bracket, complete in all respects.
Supply, delivery, erection and commissioning of pressure transmitter, GSM based remote terminal unit with analog and digital parameter,GSM/GPRS wireless communication modem, electromegnatic flow meter, equators,SCADA software, latest configuration PC with printer unit , star delta starter/soft starter, butterfly / sluice valves of suitable capacity to centralised control or any other equipment required for tubewell, pumping machinery, collection tank and storage tanks complete in all respect.
MS Kamal Dev Sharma
SS RANA CONSTRUCTION PRIVATE LIMITED
Kashmirilal Constructions Pvt. Ltd.
Thakur Constructions
Universal Electric Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .