Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC ADAM KANAN JHARGRAM 721507 | JHARGRAM | WEST BENGAL | 721507 | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.3 L+₹2,830.59 (1.25%)Rejected-Finance GHORADHARA JHARGRAM | L2 | Rejected-Finance L2 | |
| 3 | L3₹2.3 L+₹3,396.66 (1.50%)Rejected-Finance 211 2 NARAYANTALA EAST BAGUIHATI KOLKATA | KOLKATA | WEST BENGAL | 700001 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹5,265
Closing Date
25 Feb 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE,MMSD-I,PHED DTE.
Government of West Bengal Office of the Assistant Engineer, Midnapore Mechanical Sub-Division-1 P.H. Engineering Directorate Inda P.H.E. Complex, Kharagpur
Repairing and rectification of Dual use solar PWSS at Chilgora Primary School , Block Medinipur Sadar , Dist. Paschim Medinipur under Midnapore Mechanical Division, P.H.E. Dte.
2023_PHED_477516_2
WBPHE/AE/MMSD1/NIeT11OF202223
Open Tender
Electrical Work/ Equipment
Item Wise
7 days
Inda, Kharagpur, Paschim Medinipur
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,265
22 Mar 2023
20 Feb 2023
28 Feb 2023
21 Feb 2023
25 Feb 2023
21 Feb 2023
Withdrawing of the existing India MK-II hand pump set with all accessories along with installed submersible solar pump-motor set including HDPE delivery line part by part by engaging skilled manpower with hiring of required tool-tackles, necessary mobilization charges all complete as per direction of E.I.C.
Supply, delivery at site solar panel based DC submersible pumping machinery (preferably with stainless steel fabricated components) with solar cable and cable connector kit, controller, Overload protection, Dry Run protection, Auto restart facility, Float switch with water level sensors, software for start-up of motor, making necessary connection with supplying G.I. Controller box including maintenance for entire installations for 5 years as per direction of E.I.C. i) submersible pump having shutoff head 120m (max)with water output 5000lit/day from a total dynamic head of 90 mtrs coupled with 1 H.P. brass less DC motor with efficiency more then 90% , Vmax 102V ,operating voltage 72-96V Rpm 2300to 2450. ii)Maximum installation depth 60 mtr. iii)pump outlet size 25-32 mm pump controller contains DCMCB, Backup Diode having MPPT Technology, inbuilt data logger with wireless access, multiple analog & digital inputs and outputs ,Auto restart and IP54 protection. (Make-As per MNRE approved vendor list)
Float sensor with 3core 1sq. MM cable of sufficient length.
1.1 KV grade 3 core 2.5 mm2 Cu flat submersible cable as per IS-694 (Make- As per approved vendor list of PHED vide no- PHE/IV/2277/W-181/19 dated 25.09.2019 with latest arnendments.) cable for motor .
1.1 KV grade 3 core 1.5 mm2 Cu wire as per IS-694 (Make- As per approved vendor list of PHED vide no- PHE/IV/2277/W-181/19 dated 25.09.2019 with latest arnendments.) cable for sensor & earthing.
Repairing of Rising main, delivery main, over flow, wash out pipe line with supplying fitting & fixing PVC pipe (ASTMD schedule-80,medium duty) conforming to ASTMD-1785 and threaded to match with G.I. pipes as per IS,1239 (part-I) with all necessary accessories valves and fitting as per ISI marks, including laying UPVC distribution main as per departmental speciation to feed the water nearest to houses at least one habitation gate water through stand post and complete the all works as per drawing & as per direction of E.I.C. A) 32 mm UPVC
B) 25 mm UPVC
C) 15 mm dia. bib cock ( as per site requirement)
Rectification of existing M. S. structure top frame (for mounting of SPV) to make 20 to 25 inclination for getting better solar irradiation effect by gas cutting the existing one, Welding buy supplying of M.S angles channel etc of existing size as required to complete the job cost in all respect including hearing charges of required nos. of labour, tool-tackles, consumables like electrode etc. And providing other safety measures all complete as per entire satisfaction of E. I. C.
Painting of the existing Steel structure after cleaning and preparation of surface by emery paper and providing to cost of synthetic enamel paint over one cost of red oxide primer all complete as direction of E. I. C. including washing of 5000ltr.water tank, pipe line washing etc.
Single earthing the whole installation by ISI medium GI pipe complying with IE rule including Supplying of all necessary earthing materials (7/14SWG G.I.wire -35 mtr) to complete the job as direction of E. I. C.
Lowering & re-installation of IM-II set along with delivery pipe line ,other parts as necessary and as direction of E. I. C.
Surface dressing and preparation of the ground after removal of shurbs, single brick flat soling of picket bricks including ramming and dressing bed upto required level and filling joints with local sand as per complete satisfaction of E.I.C.
Ordinary cement concrete (1:2:4) with graded stone chips (20 mm pakur variety)without any reinforcements on the brick soling area upto a thickness of 50mm.
wire net fencing 1.22 mtr high from ground level approximately 2mtr. x 2mtr. And 1mtr. Wide Gate with iron angle support at least 9nos. ISA65 medium grade.
Supply, delivery and installation double layer HDPE water storage tank having capacity of 5000 lit. at a staging height of 3mtr of approved make and brand including punching of required nos. .of holes and necessary pipeline connection all complete as per direction of E. I. C. (Make-Approved make, the supplied HDPE tank should have warranty of 5 years.)
SUJOY RANJAN BHOWMICK
P K ENGINEERING
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .