| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder for the work | |
| 2 | L2₹29.5 L+₹1.2 L (4.28%)Rejected-AOC 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L2 | Rejected-AOC Other than the lowest bidder | |
| 3 | L3₹30.2 L+₹1.9 L (6.60%)Rejected-AOC 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | L3 | Rejected-AOC Other than the lowest bidder | |
| 4 | L4₹30.6 L+₹2.3 L (8.15%)Rejected-AOC | L4 | Rejected-AOC Other than the lowest bidder | |
| 5 | L5₹30.8 L+₹2.5 L (8.81%)Rejected-AOC | L5 | Rejected-AOC Other than the lowest bidder |
Tender Value
₹29.6 L
EMD Value
₹59,200
Closing Date
1 Mar 2021, 6:00 pmClosed
Commander Works Engineer Bhopal
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
SPECIAL REPAIR AND IMPROVEMENT TO BLDG NO P-16 TO P-18 (12 QTRS) OR MD ACCN OF GE DRONACHAL UNDER GE DRONACHAL
2021_MES_418281_1
83619/E8_CWE BHOPAL
Open Tender
Civil Works
Item Rate
180 days
Bhopal
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Yes
GE Dronachal
₹59,200
Yes
18 Mar 2021
2 Feb 2021
3 Mar 2021
2 Feb 2021
1 Mar 2021
16 Feb 2021
Amount
Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level)
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed.
Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately.
Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
Supply only integral water proofing compound.
M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer-in-charge.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
M & L for brick work with fly ash bricks of class designation 7.5 and modular size as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 30 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge.
M & L for chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 25 cm X 25 cm X 22 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 20 mm thick bedding of cement mortar(1:4) all as specified and as directed.
S & F in repairs vitreous china squatting pan, 'Orissa" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S' trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
S & F in repairs 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
S & F in repairs 15 mm nominal size, screw down stop valves, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed.
M & L for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
S & F in repairs 15 mm nominal size, nonrising spindle type fancy pillar taps as per IS 8931: 1993, cast copper alloy body with knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F in repairs 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F in repairs 15 mm nominal size, nonrising spindle type fancy concealed stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed
S & F in repairs grating square 150 mm size of PTMT (Minimum weight 100 gms) complete all as specified and as directed.
Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge.
S & F in repairs 20 mm dia harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed.
S & F in repairs sink made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers & 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to draft wall or including fixing cantilever brackets & connecting union to pipe, overall size 495 mm X 420 mm, bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed.
S & F in repairs Kitchen stainless steel plate rack of size 31" X 36" X 10" as per catalogue No. P-348 of Prayag or equivalent of Make mentioned under Appendix ‘B’ to Particular Specification including necessary fixing / fittings & making good the existing surfaces complete all as specified and directed.
S & F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed.
S & F towel ring of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (Minimum weight of 90 Gms) complete all as specified and as directed by Engineer-in-Charge.
S & F shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 300 gms) complete all as specified and as directed.
S & F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes of size 100 mm jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipes of size 75 mm jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
S & F cast iron, sand cast, socket and spigot, nominal dia 100 mm soil, waste and vent pipe as per IS 1729: 2002 in any length with cement joints, fixed to walls complete all as specified and as directed.
S & F cast iron, sand cast, socket and spigot, nominal dia 75 mm soil, waste and vent pipe as per IS 1729: 2002 in any length with cement joints, fixed to walls complete all as specified and as directed.
S & F cast iron bends (any radius) with duck's foot or heel rest (larger bore measured) without access door for soil, waste and vent pipes of nominal size 75 complete all as specified and as directed.
S & F cast iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches without access door for soil, waste and vent pipes of nominal size 100 mm complete all as specified and as directed.
S & cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) without access door for soil, waste and vent pipes of nominal size 100 complete all as specified and as directed.
S & F cast iron vent cowl for 100 mm bore pipe complete all as specified and as directed.
Providing and fixing galvanised steel holder bat clamps of approved design to 100 mm dia/ bore rain water pipe/ soil waste pipe embedded in and including cement concrete blocks 100 mm X 100 mm X 100 mm of Nominal Mix (M15) using 20 mm nominal size graded crushed stone aggregate and cost of cutting holes and making good at any floor complete all as specified and as directed.
Preparation of old or previously untreated steel surfaces of any description, over 10 cm width or girth and applying one coat of black Japan paint complete all as specified and as directed by Engineer-in-Charge.
Supply and fix PVC (SWR) 'P' trap plain including jointing with adhesive, size 125 mm X 110 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed.
M & L for non skid, rectified, colour ceramic floor tiles (group B II), area of each tile exceeding 0.04 sqm but not exceeding 0.12 sqm, length less than 340 mm, minimum 7 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed.
M & L for non skid, rectified, colour ceramic floor tiles (group B II), area of each tile exceeding 0.22 sqm but not exceeding 0.40 sqm, length more than 460 mm but less than 650 mm, minimum 10 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed.
M & L for non skid, rectified, colour ceramic floor tiles (group B II), area of each tile exceeding 0.22 sqm but not exceeding 0.40 sqm, length more than 460 mm but less than 650 mm, minimum 10 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate, 25 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
M & L for glazed ceramic tiles coloured, digital printed with highlighter and bath concept as per design and pattern approved by GE of size 450 mm X 250 mm X 8 mm or 450 mm X 300 mm X 8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc.
M & L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
Taking down wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and as directed.
Taking down and refixing in same opening wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and as directed.
M & L for plain, solid, straight chowkhats and frames made out of timber species of group I and durability class I as per IS 12896: 1990 and first grade as per IS 4021: 1995, wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
S & F flush door shutters, 30 mm thick, solid core of particle board construction, FAT-I or XPS designation, bonded with BWR adhesive with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed.
M & L for 30 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-2): 1994, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (b) complete all as specified and as directed by the Engineer-in-Charge.
S & F prelaminated particle board (decorative lamination on both sides), 20 mm thick, grade I or II & type IV (Designation PLB-14 or PLB-24), made out of medium density particle board (flat pressed-three layer or multilayer and graded (grade I or grade II), bonded with BWR adhesive), fixed with screws to timber/ steel frame work for vertical applications as panelling, partitions, cupboard shutter, etc. complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. not exceeding 10 kg each brackets (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and as directed.
Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge.
Providing and fixing 30 mm thick factory made solid panel PVC door shutter as per IS 15931: 2012 with 19 gauge thickness mild steel tube and tapering 20 mm in 45⁰ angle on both sides forming styles and on the inner side to form top and bottom rail and on both sides to form lock rail complete all as specified and as directed.
S & F butt hinges, extruded aluminium alloy with brass wire pin, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, hinge designation 75C21 as per IS 205: 1992 complete all as specified and as directed.
S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F extruded aluminium alloy handle, fabricated type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F in repairs aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than
S & F in repairs floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 150 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 40 & 45 mm thickness of door shutter, fixed in floor complete all as specified and as directed.
S & F timber species of group I for frames and durability class I as per IS 12896: 1990 for small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like articles not exceeding 200 cucm each complete all as specified and as directed.
Dismantling of wrought or mild steel work of any description not otherwise described into primary parts.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S & F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and as directed.
S & F stainless steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F in repairs stainless steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles complete all as specified and as directed.
M & L for preparation of surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint complete all as specified and as directed.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
Refixing 15 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed.
Refixing 20 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed.
Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., not exceeding 10 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Disconnecting existing water tanks capacity exceeding 250 litres but not exceeding 500 Litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required, reconnecting and re-fixing in position. (cleaning repairing, etc. measured separately)
Dismantling water tanks capacity exceeding 250 litres but not exceeding 500 Litres and keeping aside for credit complete all as specified and as directed.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
S & F in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed by the Engineer-in-Charge.
S & f nipple suitable for HDPE water tank and 20 mm bore dia pipe (minimum weight 20 mm-45gm) ball as specified and directed
Complete removal of existing treatment of wall and Material & Labour for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over 1 mm thick wall care putty complete all as directed
Material & Labour for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over 1 mm thick wall care putty complete all as directed
Preparation of old decorated surfaces on walls and applying one coat of white wash complete all as specified and as directed.
Preparation of newly plastered surfaces/boards on ceilings and applying three coats of white wash complete all as specified and as directed.
Preparation of old decorated surfaces on ceilings and applying one coat of white wash complete all as specified and as directed.
Preparation of old painted steel surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M & L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Providing & applying evenly a coat of industrial bitumen 85/25 @ 1.2 kg per sqm including cleaning over primed surfaced (interval between 1st & 2nd coat shall be as directed by Engineer-in-Charge)
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise not exceeding 100 sq cm
S&F UPVC Pipes 50mm bore with pressure rating 10 Kg/ sqm fixede to walls ceilings and floors work
M & L for flush pointing to brick on edge pavings in cement mortar 1:3 complete all as specified and as directed.
M & L for structural timbers of group B, first or second choice as per IS 3629: 1986 in fillets, square, rectangular or triangular in section, clean sawn, secured with screw, area not exceeding 3 sqcm complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
M & L for concealed point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
M & L for concealed point wiring for one light controlled by two 2-way switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
S & F buzzer, din dong, suitable for single phase, AC, 240 volts complete all as specified and as directed.
S & F batten including tube light 18W, Polycarbonate housing, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 140 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1800, lumen efficacy of minimum 100 lumens per watt, integral electronic driver (SMPS based constant current output) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, CRI greater than 80%, THD less than 20%, CW available CCT of 6500K, power factor of minimum 0.95, life span of minimum 50000 working hours as per catalogue No. LHEXBLP5PN1W018 of Havells or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.
S & F batten including tube light 10W, Polycarbonate housing, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 140 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1000, lumen efficacy of minimum 100 lumens per watt, integral electronic driver (SMPS based constant current output) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, CRI greater than 80%, THD less than 20%, CW available CCT of 6500K, power factor of minimum 0.95, life span of minimum 50000 working hours as per catalogue No. LHEXACP7IN1W010 of Havells or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed.
S & F LED Bulb/ lamp non-dimmable type 10 watts with high power LEDs as light source and electronic driver complete all as specified and as directed.
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F switch, 6 A, single pole, two way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F isolator TPN, 63 A, 240 V complete all as specified and as directed.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
Taking down main switch/MCB DB/ MCCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.
Taking down ceiling fan 1200/1400 mm sweep / exhaust fans including disconnection of electric connection, dismantling blades and removing fan and blades to store complete all as specified and as directed.
S & F ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, minimum air delivery 200 m³ per minute, minimum service value 4 m³ per minute per watt, maximum power input 50 watt, 3 Nos metal blades protected with corrosion resistance paints, class I type with double insulation, insulation class A for temperature rise, ISI marked including capacitor to ensure power factor more than 0.9, five star rating as per Bureau of Energy Efficiency complete all as specified and directed by Engineer-in-charge.
S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 300 mm sweep, 4 pole, heavy duty with louvers, metal body, 4 Nos blades, Insulation Class A, 5 star rated as per Bureau of Energy Efficiency (BEE) including capacitor to ensure power factor more than 0.9 complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Taking down old unserviceable submain wiring 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface to match the existing surface complete all as specified and as directed.
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good complete all as specified and directed by Engineer-in-charge. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)
S & F electronic energy meter, single phase, 240 V, 50 Hz, AC supply, accuracy class-I. current rating 5 to 30 Amp, LCD display, polycarbonate body, tamper proof design, communication port as per Model No. SPPB1310000002OC00 of HPL or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.
S & F meter box made out of FRP, IP55 protection, size of 400 mm X 300 mm X 190 mm as per Model No. GSJB-4030 of M/s Sintex or equivalent of Make mentioned under Appendix "B" and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Cutting hole of area exceeding 400 sqcm but not exceeding 1000 sqcm into or through brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete and making good in cement mortar 1:3 or cement concrete M15 (Nominal mix) using 12.5 mm nominal size coarse aggregate complete all as specified and as directed.
M & L in repairs for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
Supplying, installing, testing & commissioning, storage water heater (geyser), 25 litres capacity, standing loss less than 0.562 Kwh per day for 45⁰C difference of temperature as per IS 2082 (five-star rated as per BEE), reheating time less than 60 minutes, mixing factor less than 20%, shock proof high density PUF insulation body material, glass lined inner tank material having warranty 7 years on tank material, 4 years on heating element and 2 years on other spares parts comprising following fittings (a) glass coated incoloy element (b) capillary type thermostat (c) digital display unit (d) thermal cutout (e) multifunction valve (f) earth leakage circuit breaker (g) magnesium anode rod cathodic protection (h) flexible cable of suitable length with 3-pin plug of 16A capacity (i) drain plug (j) fusible plug fitted on the crown of water heater with operating temperature between 100⁰C to 110⁰C including fixing by grouting and fastener complete all as specified and as directed.
S & F bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
Taking up or down 25 mm or 32 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
Taking up or down 40 mm or 50 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supplying & laying in trenches 50 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in trenches 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S & F in repairs 50 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
S & F in repairs 25 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
Cutting galvanised mild steel pipe of nominal bore 25 mm or 32 mm for alterations or additions (each cut measured) complete all as specified and as directed.
Disconnecting, taking out old unserviceable under ground cable of rated voltage 1100 V, nominal cross sectional area of main conductor 10 sqmm, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) all as specified and directed by the Engineer-in-Charge.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Supplying & laying in trenches, in road cutting and along pole 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
M/S Shanti Enterprises
POONAM ELECTRIC INDUSTRY
RAJPATI CONSTRUCTION
M/S BRIJLAL UPADHYAY
ROYAL CONSTRUCTION
M/S Shanti Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .