| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.4 L+₹99,281.50 (6.87%)Rejected-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹16.0 L+₹1.6 L (11.0%)Rejected-Finance 300 STREET NO 10 PREM BASTI SANGRUR PB PUNJAB 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | Jawandha Enterprises L2 | NARINDER KUMAR SONS L1 | krishna engineers L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling and taking out old broken prestressed concrete poles in any location and of any size complete all as specified and as directed. | 4 | Each | 2,500 ₹10,000 | 1 ₹4 Lowest | 50 ₹200 |
| 2.00 | Taking down old aluminium conductors including GI wire, insulators of any type from poles in any location complete all as specified and as directed. | 1 | Per Qtl | 500 ₹500 | 1 ₹1 Lowest | 50 ₹50 |
| 3.00 | Dismantling cross arms of MS channel or angle section etc. from poles /2 pole/ 4 pole structures complete all as specified and as directed. | 2 | Per Qtl | 500 ₹1,000 | 1 ₹2 Lowest | 50 ₹100 |
| 4.00 | Taking down insulators of any type, any size shape from any location complete all as specified and as directed. | 18 | Each | 50 ₹900 | 1 ₹18 Lowest | 50 ₹900 |
| 5.00 | Supply and fixing in repairs high tension lightning arrestor expulsion type suitable for 11000 Volts complete with all fittings transmission class discharge capacity 65 Kilo Amps complete all as specified and as directed | 4 | Set of Three | 2,700 ₹10,800 | 2,000 ₹8,000 Lowest | 2,000 ₹8,000 Lowest |
| 6.00 | Supply and errecting prestressed concrete pole 11 mtr long 152mmx152mm at top and 152mmx260mm at bottom of class 9, including painting with five strips of 30cm each black and white paint in alternate strips from the top of coping of pole upto1.5mtr height complete, spray painting with two coat of synthetic enamel paint of superior quality complete all as specified and directed. | 4 | Each | 7,500 ₹30,000 | 10,000 ₹40,000 | 4,500 ₹18,000 Lowest |
| 7.00 | Supply and fixing in repair pin type porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height,150 mm dia for 11000 Volts grade complete all as specified and as directed. | 12 | Each | 500 ₹6,000 | 100 ₹1,200 Lowest | 250 ₹3,000 |
| 8.00 | Supply and fixing in repair Disc type insulator, porcelain,vitreous 145mm high and 255mm dia ball and socket type white brown or green single disc assembly for tension with tension clamps for conductors working pressure 11000 Volts complete all as specified and as directed. | 6 | Each | 850 ₹5,100 | 100 ₹600 Lowest | 250 ₹1,500 |
| 9.00 | Supply and fixing in repairs triple pole mechanically operated (GOD) mounted on 12 insulators and steel frame with operating mechanism worked from ground level of 11000 volt grade for current rating 200 Amps with dropout fuse (barrel type) of capacity 40 Amps, made out of copper complete all as specified and as directed. | 6 | Each | 11,500 ₹69,000 | 10,000 ₹60,000 Lowest | 16,000 ₹96,000 |
| 10.00 | Supply laying & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 Volts grade, of 95 Sq mm 3 core after removing old unserviceable PILCA/XLPE cable & cable covers etc complete all as specified and as directed.Note:- (Excavation, earth work,sand cushioning and cable cover will be measured and paid separately). | 390 | RM | 900 ₹3,51,000 Lowest | 900 ₹3,51,000 Lowest | 1,000 ₹3,90,000 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
8 Aug 2025, 6:00 pmClosed
HQ CWE PATIALA
HQ COMMANDER WORK ENGINEER BLDG NO 26 NEW LALBAGH PATIALA 147001 CONTACT NO 01752200082
REPAIR REPLACEMENT OF EXTERNAL ELECTRIC HT CABLE SUPPLY AND MISC WORK AT SANGRUR UNDER GE S PATIALA
2025_MES_719958_1
CWE/PAT/T-16/2025-26
Open Tender
Civil Works
Item Rate
150 days
PATIALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE SOUTH PATIALA
₹30,000
25 Sept 2025
11 Jul 2025
11 Aug 2025
11 Jul 2025
8 Aug 2025
25 Jul 2025
11 Jul 2025 - 22 Jul 2025
Amount
Dismantling and taking out old broken prestressed concrete poles in any location and of any size complete all as specified and as directed.
Taking down old aluminium conductors including GI wire, insulators of any type from poles in any location complete all as specified and as directed.
Dismantling cross arms of MS channel or angle section etc. from poles /2 pole/ 4 pole structures complete all as specified and as directed.
Taking down insulators of any type, any size shape from any location complete all as specified and as directed.
Supply and fixing in repairs high tension lightning arrestor expulsion type suitable for 11000 Volts complete with all fittings transmission class discharge capacity 65 Kilo Amps complete all as specified and as directed
Supply and errecting prestressed concrete pole 11 mtr long 152mmx152mm at top and 152mmx260mm at bottom of class 9, including painting with five strips of 30cm each black and white paint in alternate strips from the top of coping of pole upto1.5mtr height complete, spray painting with two coat of synthetic enamel paint of superior quality complete all as specified and directed.
Supply and fixing in repair pin type porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height,150 mm dia for 11000 Volts grade complete all as specified and as directed.
Supply and fixing in repair Disc type insulator, porcelain,vitreous 145mm high and 255mm dia ball and socket type white brown or green single disc assembly for tension with tension clamps for conductors working pressure 11000 Volts complete all as specified and as directed.
Supply and fixing in repairs triple pole mechanically operated (GOD) mounted on 12 insulators and steel frame with operating mechanism worked from ground level of 11000 volt grade for current rating 200 Amps with dropout fuse (barrel type) of capacity 40 Amps, made out of copper complete all as specified and as directed.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 Volts grade, of 95 Sq mm 3 core after removing old unserviceable PILCA/XLPE cable & cable covers etc complete all as specified and as directed.Note:- (Excavation, earth work,sand cushioning and cable cover will be measured and paid separately).
Supply and fixing in repair cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and as directed.
Supply and fixing in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and as directed.
Supply and fixing in repairs anti climbing device, spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and as directed.
Supply and fixing in replacement danger notice plate 11 KV of 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps out of flat iron 50x4mm, bolts and nuts of approved size for HT 25x20cm size complete all as specified and as directed.
Material and labour for aluminium conductor,steel reinforced (weasel,Ferret,monk),stringing,streaching and binding with insulator, on existing RCC/steel HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections with aluminium binding wire of 14 SWG on insulators complete all as specified and directed.
Material and labour for cross arms, bracings, supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size and inclusive of one primer coat one under coat and one finishing coat of paint complete all as specified and as directed.
Supply and fixing galvanised steel wire 4 mm dia for continuous earth conductor in earthings, making cradles in hexagonal / rectangular shape as per site requirement to guard HT over line complete all as specified and as directed.
Servicing of HT VCB 630 Amps,11 KV including calibration/ setting of all parameters and repairs of VCB of Crompton Greaves make 2013 model complete incl cleaning and greasing and replacement of unserviceable parts, replacement of unsv copper wiring as per existing and testing for satiafactory operation and smooth functioning as per manufacturer's standards complete all as specified and as directed.Notes :- (i) Spares shall be measured and paid seperately.(ii) Servicing shall be carried out by authorised rep of OEM.
Supply and repacement VCB indicator lamps LED type as per existing colour code and making all connections as per existing complete all as specified and as directed
Supply and fixing in replacement of tripping and closing coil of VCB trolly as per existing incl taking out unsv complete all as specified and directed.
Supply and replacement of VCB vacuum interrupter as per existing and making all connections as per existing complete all as specified and directed.
Supply and replacement of DC power pack having AC input 220 volt and DC output 24V incl 2 nos of 7 AH batteries as per existing make and making all connections as per existing complete all as specified and directed
Supply and replacement of VCB over current & earth fault protection relay as per existing and making all connections as per existing complete all as specified and directed.
Supply and replacement only 220 Volts AC/DC spring charging motor suitable for VCB (CG Make) 11 KV complete all as specified and as directed
Supply and replacement of VCB CT of ratio 60-30/5+5A as per existing make and model and making all connections as per existing complete all as specified and directed.
Supply and replacement of VCB insulators as per existing make and model and making all connections as per existing complete all as specified and directed.
Supply and replacement of VCB Trip & Close (T&C) switch as per existing make and model and making all connections as per existing complete all as specified and directed.
Supply and replacement of VCB digital ampere meter per existing make and model and making all connections as per existing complete all as specified and directed.
Supply and replacement of VCB digital volt meter as per existing make and model and making all connections as per existing complete all as specified and directed.
Material and labour for earthing in repairs complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip 32x6 mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel suitable size GI Pipe for protection of GI Strip and Watering pipe 15 mm dia with funnel all as shown in electrical plate No. 4, connected to machinary /panel complete including PCC pit in PCC(1:3:6) type C-1, pre cast RCC nominal mix cover slab reinforced with 8 mm dia mild steel TMT bars 15cm c/c and suitable handle of 10 mm dia round bar including necesary excavation earth work in soft/loose soil and disposal of soil to a distance n.exc 50m complete all as specified and as directed.
Material and labour for complete removal of old paint and primer by scratching, rubbing from transformer any capacity and of any make and size including XPM wire mesh complete,applying by spray painting machine with two coat of synthetic enamel paint of first quality dark grey/ivory colour over a coat of red oxide primer and marking SM No complte as directed complete all as specified and as directed.
Disconnecting the electric connections of incoming and outgoing cable and taking down the defective transformers indoor/ outdoor type 11 KV/433 Volts of capacity 75 KVA to 315 KVA from any position by hiring Crane service for lifting up & down and arranging suitable size vehicle for transporting to auth workshop for rewinding of transformer, repairs, shifting back the same to site after repairs and installing & testing at original position complete all as directed, connecting up, commissioning and testing. Notes : (a) The item includes for draining out transformer oil, opening up transformer taking out core, HV and LV windings to detect faults, reassembling the transformer after necessary repairs including replacement of top rubberised/ fiber gasket and worn out fastners such as nuts, bolts and washers for fixing of top covers (b) Spare parts i.e HT/ LT insulated copper winding, HT, LT Brass rod shall be measured and paid separatelty. (c) Proper care should be taken during dismantling/transportation of the transformer,if the transformer is damaged due to the neglegency,contractor shall be responsible for the same and cost of the same will be paid by the contractor at no extra cost.
supply and replacement of burnt defective HT copper coil of existing size, winding with superior quality enamelled copper winding wire/strips of approved make of suitable size/guage and number of turns matching with the existing impendence and insulated including all allied materials such as cork sheet, fiber glass insulation/paper insulation/Lathoride paper, cotton, empire tape and wooden blocks, bolts, nuts & washers (Brass) soldering/welding and other packing material etc required for entire winding of coils complete all as specified and as directed .
All as per serial item no.33 here-in-before but defective LT copper coil complete all as specified and as directed.
Supply and replacement of HV brass rods with porcelian bushing, nuts, bolts, washers gaskets suitable for 100 KVA to 250 KVA transformer of any type complete all as specified and as directed..
Supply and replacement of LV brass rods with porcelain bushing , nuts, bolts, washers gaskets suitable for 100 KVA to 250 KVA transformer of any type complete all as specified and as directed. .
Supply and replacement of air breathers transparent type suitable for transformers 11 KV / 433 Volts of capacity up to 315 KVA of any type complete all as specified and as directed.
Supply and replacement of Silica gel of breathers of transformers of type, any capacity and in any location complete all as specified and as directed.
Material and labour for servicing of transformer by arresting leakages by tightning nuts, bolts, replacement of unsv gasket, worn out washer of top cover and LV bushings, HV bushings etc complete all as specified and as directed.
Dehydration and filteration of transformer oil of transformer any capacity indoor/ outdoor type with dehydration machine including checking of dielectric strength of transformer oil before and after dehydration complete all as specified and as directed. Note :- Dielectric strength should be 50-60 KV for 1 mm gap.
Supply and topping up the transformer oil for transformer of appropriate grade confirming to IS- 335 with latest amendments suitable for 11 KV/433 Volts step down transformer complete all as specified and as directed. Note:- Dielectric strength test report alongwith purchase voucher will be submitted by contractor to Engr-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation of poles, struts,stays and laying of cables etc and getting out in Hard/dense soil complete all as specified and as directed.
All as per item No. 42 here-in before but depth exceeding 1.5 m and not exceeding 3.00 m complete all as specified and as directed.
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer in Hard/dense soil complete all as specified and as directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Material and labour for laying clean dry fine river sand in trenches /ducts for bedding and cushioning to cable, 8 cm thick before laying the cable and 15 cm thick after laying the cable including punning down the sand to over all 18 cm thickness, levelling and consolidation complete all as specified and as directed. Note:- (i) Consolidated/ punned thickness of sand will be measured for payment purpose.
Material and labour for laying un-reinforced precast concrete cable covers conforming to IS-5820-1970, class HV, type 1 flat of size 300mm x 180mm x 40mm laid in trenches as protection to cables complete all as specified and as directed.
Supply and fixing in repair GI tube light grade 80 mm bore in trenches/ along poles under roads/floor etc complete all as specified and as directed.
Material and labour for cement concrete type D-2 1:4:8 using 40 mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and as directed.
Material and labour for cement concrete type C2 1:3:6 using 40 mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and as directed.
Material and labour for cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in platform, filling and mass concrete, coping to new/existing pole etc, including necessary form work if required and applying two coats of white wash to exposed surfaces of coping/platform including dismantling/ demolition of the existing concrete complete all as specified and as directed.
Repair/Maint day to day HT electrical network in the jurisdiction of AGE B/R Sangrur cantt area scattered within 1 KM radius intimated by Engineer-in-charge, JE , SBA as well as users by deploying dedicated team having good knowledge of HT line and fault rectification the defect of day to day working as under :- Note:- Store/material required will be issued by department
Cleaning of all type breakers/switchgears, Transformer, Panels, tightening of connections in HT breakers/ switchgears installed in sub station No -1, 2, 3, 4, 5, 6, 7, 8, 9,10,11,12,13 & 14 at various locations compete all as specified and as directed.
Replacement of HT fuse wire all as specified and as directed by Engineer-in-charge.
Repair/replacement of HT jumper all as specified and as directed by Engineer-in-charge.
Repair/replacement of GOD male/female contact all as specified and as directed by Engineer-in-charge.
Finding and rectification of fault on HT line and repair the HT line as specified and as directed by Engineer-in-charge. Note (A) : (a) Contractor will provide all T&P, communication device (Mobile Phone) to deployed persons required for repair of HT/LT Electrical switch gear including safety equipments such as all types of T&Ps (Bambooladders, screw drivers, wire/cable cutters with blades, multi meters, cutting pliers, tourch lights etc) for routine maintenance and protection of the trademan as well as daily activity incl safety dress, hand gloves, rubber boots, safety belts and helmets etc, complaint register, job card and necessary transportation required for attending complaints/faults/brake downs duty wiil be provided by the contractor without any extra cost. (b) On intimation of any type of fault tripping of HT/LT switch gear incomer as well as outgoing feeder the contractor is responsible to locate the fault by the dedicated team comprising tradesman helpers required numbers as per the gravity/nature of the work involved to restorethe power supply and communicate with SBA on duty and getting permit card for working on HT lines and deposit the permit card after rectification of fault, all the activities shall be carried out within reasonable time as given by the Engineer-in-charge. (c) Periodical maintenance of following feeders which includes trimming of tree branches which are touching with HT and LT feeders and overhead line, maintenance of GOD, jumpers, maintenance of defective disc or pin type insulators, tightening of jumpers, fixed and moving parts of GODs, restretching of HT/LT overhead line conductors falling due to storms. Note (B) : Penalty Charges : If any of the activity mentioned above is not performed by the contractor than recovery as under will be affected :- (a) Not providing T&P, protective clothing or safety equipment and not used by the team - Rs 500 per Job. (b) Not providing mobile phones duly re-charged or suitable transportation as per specified above or not attending the call - Rs 500 per job per mobile. (c) Not taken repair action within 01 hour after receiving job workt - Rs 500 per job.
Jawandha Enterprises (BID ID -3379882)
krishna engineers (BID ID -3377391)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .