| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr Quoted ₹1.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.7 Cr+₹9.8 L (6.27%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | ₹1.7 Cr+₹9.8 L (6.27%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹1.7 Cr+₹14.8 L (9.42%)Rejected-Finance 26 8 2 PUNE MUMBAI ROAD OPP B U BHANDARI SHOWROOM EKTA PARK SOCIETY WAKDEWADI PUNE 411 003 | PUNE | MAHARASHTRA | 411003 | ₹1.7 Cr+₹14.8 L (9.42%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹1.8 Cr+₹23.1 L (14.8%)Rejected-Finance FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | ₹1.8 Cr+₹23.1 L (14.8%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹1.8 Cr+₹27.9 L (17.8%)Rejected-Finance 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | ₹1.8 Cr+₹27.9 L (17.8%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹2.2 Cr
EMD Value
₹3.0 L
Closing Date
24 Aug 2023, 6:00 pmClosed
Chief Engineer Pune Zone
HQ Chief Engineer Pune Zone Dakshin Kaman Marg Camp Pune 411001
ADDN ALTN TO OTM ACCN AT CAFVD KHADKI UNDER GE (CENTRAL) KHADKI
2023_MES_609279_1
CA NO CEPZ/KKE/T-06 OF 2023-24
Open Tender
Civil Works
Item Rate
365 days
Khadki
Class B Category a(i)
Also refer NIT
8 documents required · 8 mandatory
₹2,000
GE (Central) Khadki
₹3.0 L
Yes
12 Oct 2023
15 Jul 2023
26 Aug 2023
15 Jul 2023
24 Aug 2023
17 Aug 2023
17 Jul 2023 - 24 Jul 2023
Amount
Dismantling asbestos cement (corrugated or semi corrugated) sheets as in roof coverings complete all as specified and as directed.
Dismantling structural steel in any postion including doors, gates framed truss etc., complete all as specified and as directed.
Excavating in trenches, not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth and getting out in any type of soil all as specified and as directed.
Excavating over areas, n.exc. 1.5 m deep and getting out in any type of soil all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick all as specified and as directed.
Removing excavated material (soils) exc. 1.50 km but n exc. 5 km and depositing where directed at a level n exc. 1.5 m above the starting point .
Material and labour rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, girders, channel or flat sections) including distance pieces, cleats etc., conforming Fe 410 -W(Gde-E- 250) quality-A complete all as specified and as directed.
Supply and fix rolled mild steel as in wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.,) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified and as directed.
Supply and fix pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
Supply and fix fibre glass reinforced translucent corrugated sheeting, 2mm thick, with two corrugations side lap fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed.
Material and labour brick work with fly ash old size bricks straight or curved on plan exc. 6 m mean radius built in CM (1:6) complete all as specified and as directed.
Demolition of un-reinforced cement concrete as in ground floors and pavings not exceeding 15 cm thick (below or above ground level) complete all as specified and as directed.
Demolition of reinforced cement concrete in any position complete all as specified and as directed.
Material and labour for 75 mm thick Plain Cement Concrete, (1:4:8) type D-2, using 40mm graded stone aggregate as in sub bases, floors and paving etc., complete all as specified and as directed.
Material and labour 50 mm thick Plain Cement Concrete, type B1, (1:2:4), using 20 mm graded stone aggregate as in sub bases of floors complete all as specified and as directed.
Material and labour for machine pressed precast concrete interlocking paver blocks with grey cement and pigments, any shape and size conforming to IS 15658-2006 of 80 mm thickness, M-40 Grade, ISI marked, set over and including 25mm thick sand cushion complete all as specified and as directed.
Material and labour Granolithic floor topping (1:1:2) 30 mm thick with and including wear proof toping 30 mm thick incorporating approved metalic floor hardener (metalic floor hardener shall be measured and paid separtely) over and including 50 mm thick Plain Cement Concrete, (1:2:4), type B1 using 20 mm graded stone aggregate laid on floors finishing cement concrete surfaces even and smooth using extra cement complete as specified and as directed.
Supply only approved metalic floor hardner complete all as specified and as directed.
Demolition of brick /stone walls built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed.
Material and labour for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM (1:4) complete all as specified and as directed.
Taking down cement plaster on brick or stone or concrete walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.,complete all as specified and as directed.
Hacking for key, raking out joints of old brick work or stone work built in lime or mud or cement mortar; not previously plastered; and scrubbing down with water etc., complete all as specified and as directed.
Material and labour raised pointing in CM (1:3) to random rubble or polygonal rubble stone masonry uncoursed or brought up to courses as in wall , surface channels, roofs, etc.complete all as specified and as directed.
Material and labour for flush pointing in CM (1:3) to random rubble or polygonal rubble uncoursed or brought upto courses as in wall, surface channels, roof etc., complete all as specified and as directed by Engr-in-Charge.
Material and labour for rendering 15 mm thick in CM (1:6) on fair faces of brick work / stone masonry or concrete surfaces finished fair and even complete all as specified and as directed.
Material and labour for rendering / plastering, 15 mm thick in cement mortar (1:4 ) on fair faces of brick masonry / stone masonary or concrete surfaces, finished even and fair including liquid water proofing compound as per manufacturer’s instructions complete all as specified and as directed. NOTE : - Liquid water proofing compound will be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and as directed.
Material and labour for preparation of new or old surfaces of stone masonry / brick masonry or concrete surfaces of any description and applying three coats of white wash complete all as specified and as directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed.
Material and labour for complete removal of existing treatment on brick masonry / stone masonry / concrete surfaces of any description by mechanical means or other suitable tool including rubbing, washing down etc and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10sqm over new surfaces complete all as specified and as directed.
Material and labour for preparation of new or previously untreated surface of steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over one coat of red oxide primer complete all as specified and as directed.
Material and labour for preparation of old steel surfaces of any description, over 10cm width or girth and applying one coat of synthetic enamel paint of approved tint complete all as specified and as directed.
Material and labour plastic dividing strips of 2mm thick, width of strip 28 mm as directed by Engineer in charge complete all as specified and as directed.
Material and labour for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, fixed with self tapping screws complete all as specified and as directed.
Supply and fix 1.00mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as as specified and as directed.
Material and labour for Reinforced Cement Concrete, M-25 (design mix), using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
Material and labour TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to grade Fe 500 / Fe 500 D / Fe 550 / Fe 550 D meeting all requirements of IS 1786 complete all as specified and as directed.
Material and labour TMT steel bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Supply and fix steel rolling shutters, 1.25mm thickness of lathe, gear operated type with chain wheel and hand chain, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, including taking down existing unserviceable shutters of any type complete all as as specified and as directed.
Taking down frames with shutters (without taking off shutters from the frames) area n.exc. 1.5 sqm complete all as specified and as directed.
Supply and fix stainless steel wind driven turbo ventilators of approved make, 600mm effective throatal dia, 800mm outer dia, overall height of 490mm fixed over corrugated sheet of any type all as specified and as directed.
Supply and fix steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
Supply and fix rolled mild steel as in framed work such as grills, gratings, etc.. with ends of bars shouldered and /or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 and for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc., including taking down wrought iron of any description and in any position complete all as specified and as directed.
Surface dressing n.exc. 15 cm deep and getting out hard /dense soil complete all as specified and as directed.
Supply and fix steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) for fair finished surfaces all as specified and as directed.
Material and labour for Reinforced Cement Concrete, M-25(Design mix), using 20mm graded stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc., all as specified and as directed.
Material and labour for machine cut Kota stone slab flooring, 15-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing (granite finish) and exposed edges of Kota stone shall be rounded complete over 15mm thick screed bed in CM (1:6) all as specified and directed as in platform. NOTE :- Size of the Kota stone shall be 550mm x 450mm.
Taking down damaged steel doors area up to 20 sqm carrring out repairs including material and labour for replacement of damge steel part except MS sheet (sheeet will be measured separately) and re-fixing the door in position including neccessary greasing / oiling for proper functioning and any other work required for proper working of door complete all as specified and as directed.
Supply and fix 1.25mm mild steel, plain, black sheet as in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc., complete all as specified and as directed.
Material and labour for Plain Cement Concrete, (1:3:6), type C2, using 40mm graded stone aggregate, 75 mm thick as in plinth protection including providing neccesary constuction joints and finishing the surfaces even and smooth with out using extra cement complete all as specified and as directed.
Material and labour for chipping, removing carefully loose concrete work by low impact hammer breaker without damaging the structure, cleaning & disposal of malba outside the premises etc., & also cleaning the existing reinforced concrete including casting, repairing existing structure by using polymer modified mortar, with cement fine aggregate ratio 1:3 by weight mixed with polymer cement ratio 20% keeping water cement ratio 30% to 60% depending on required work stability make Dr Fixit or equivalent, thickness up to 40mm including leveling profile etc.. each layer shall not have more than 20mm with epoxy latex bond coat before each layer including formwork required at any height complete all as specified & directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the the premises complete all as specified and as directed.
Material and labour glazed ceramic coloured tiles as in vertical surfaces 350x 250x 7 mm / 450 x 350 x 7mm / 300 x 450 x 7mm thick or equivalent set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat in cement mortar (1:4) complete all as specified and as directed.
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc., set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Supply and fix vitrified ceramic tiles, dark shaded colours, 10mm thick (square/rectangular) polished area of each tile n.exc. 0.36 sqm as in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces complete over and including 15mm thick screed bed in CM(1:6) all as specified and as directed.
Supply and fix pressed steel frames made of 1.25 mm thick MS sheet size 105x60mm for doors, ventilator with single rebates including necessary fixing lugs, hinges, lock strike plate etc with and including PCC (1:2:4), type B1, using 20mm graded stone aggregate to fill the frame and making good complete all as specified and as directed.
Taking down chowkats and frame area exc. 1.5 sqm but n.exc. 4.00 sqm each including shutters without taking off shutter from the frame and removing from site complete all as specified and as directed.
Supply and fix second class hardwood 35 mm thick plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed.
Material and labour for preparation of new or previously untreated wooden surfaces of any description not other wise described over 10cm width or girth applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified and as directed.
Supply and fix 150 mm long aluminium anodised barrel tower bolts of extruded sections complete all as specified and as directed.
Supply and fix for 100mm size aluminium butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and as directed.
Supply and fix aluminium anodised handles of extruded section, fabricated type of size 150mm long complete all as specified and as directed.
Supply and fix aluminium alloy, anodised, sliding door bolt with hasp, staple and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 300mm long complete all as specified and as directed.
Supply and fix factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm thick plain colour PVC sheet on back face, with wood free EPS Supply and fix in frame at site as per specification & drawing all as specified and as directed.
Supply and fix in repairs solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, suppling & fixing in opening as per specification and drawing .
Supply and fix 100 mm long butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing and connections, complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections, complete all as specified and as directed.
Supply and fixing 15mm bore, steel tubing, galvanised, medium grade including all fittings with screwed and socket joints and jointing complete, fixed to walls/celling (on surface/concealed) or laid in floors all as specified and as directed.
Supply and fixing 20mm bore, steel tubing, galvanised, medium grade including all fittings with screwed and socket joints and jointing complete, fixed to walls/celling (on surface/concealed) or laid in floors all as specified and as directed.
Material and labour 40 mm thick Plain Cement Concrete type B-1, (1:2:4) using 20mm graded stone aggregate as in floors finished even and fair all as specified and as directed.
Supply and fix in repairs bib taps, brass chromium plated, fancy type with crutch or butterfly handle screwed for iron pipe for brass ferrule 15mm dia complete all as specified and as directed.
Supply and fix in repairs stop valves, brass chromium plated, screwed down, high pressure with crutch or butterfly handle,15mm bore size, screwed both ends for iron pipe or for unions and fittings and fixed complete all as specified and as directed.
Supply and fix in repairs 15 mm bore pillar taps, chromium plated brass, fancy type, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe all as specified and as directed.
Supply and fix in repairs PVC low level flushing cistern (white) of 10 liters capacity with inlet ball float valve, PVC flush pipe and necessary fixing arrangements and connecting to water pipe and WC etc.,complete all as specified and as directed.
Supply and fix in repairs vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and as directed.
Supply and fix in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and as directed.
Supply and fix in repairs vitreous china wash basin, white, flat back size 580x450 mm excluding taps but including 32 mm dia chromium plated waste fitting and PVC waste pipe 610 mm long and brackets complete all as specified and as directed.
Supply and fix in repairs vitreous china urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing and including automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and as directed.
Supply and fix PVC connections 15 mm dia with PTMT nuts, length of pipe 450 mm complete all as specified and as directed.
Material and labour for false ceiling with 12 mm thick perforated gypsum board granular finish, pre painted/plastic coated, fixed on and including GI powder coated frame work of grid size 600x600mm consisting of GI angle supports on walls of size 19mmx19mmx0.7mm and cross tee of size 24mmx32mmx0.7mm using purpose made members interlocking into each other and suspended from the roof by using GI hanger wire of dia 2.68 mm of adequate length with adjustable hook clip of 3.5 mm dia wire to be used with main runner etc., all as per manufacturer's instructions, make of GI grid work and ceiling board shall be 'Armstrong or equivalent approved makes as per Appendix 'C' complete all as specified and as directed.
Material and labour 15-20 mm thick granite (of any type) work, table rubbed and polished as in steps, jambs, pillars, window cills, cooking platforms and like, over and including 10 mm thick backing coat in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, grinding and polising complete all as specified and as directed.
Material and labour for preparing plastered or unplastered old surface of ceilings including brooming down or scrapping down with steel wire brushes, smoke soot, moulds, moss, efflorescent salts, trading oil and greasy spots and applying one finishing coat of white wash on ceiling complete all as specified and as directed.
Material and labour preparation of floor surfaces, removal of all debris, detrimental to flooring system, dirt, oil containments, grease & surface coating & test the moisture content & vapour emission rate to observe the surface dry, so that the surface is ready to achieve permanent bond with flooring as determined by manufacutrer recommended bond & moisture test, then apply 3mm thick two coats of component of epoxy coating in compliance with manufacturers installation instructions complete all as specified and directed. MKAE :- Dr Fixit, Fosroc or Equivalent.
Supply and fix in repairs UPVC pipes (SCH-40)150 mm dia as in rain water pipes fixed to walls including all fittings all as specified and as as directed.
Supply and fix in repairs UPVC(SCH-40) 150 mm dia bends or elbows, square, or obtuse including all fittings all as specified and as directed.
Supply and fix in repairs UPVC (SCH-40) 150 mm dia shoes including all fittings all as specified and as directed.
Supply and fix in repairs UPVC (SCH-40) 150 mm dia heads, hopper type, flat or corner including all fittings all as specified and as directed.
Supply and fix 4.00 mm thick sheet glass, ordinary quality and glazing with oil putty in square including removal of old glass all as specified and as directed.
Supply and fix rotational moulded polyethylene water storage tanks of 500 ltrs capacity (as per IS:12701), tripple layered, white, (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia brass float valve and polyethylene ball including taking down existing unserviceable tank of any capacity complete all as specified and as directed.
Taking down carefully existing unserviceable aluminum / copper point wiring of any description and in any position with and including existing steel conduit / PVC conduit / casing caping fixed on surface / wall / angle /girders including all fittings, accessories and fixtures such as switches, ceiling roses, pendants, regulators, sockets, sunken boxes / junction boxes and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and as directed.
Material and labour for point wiring for one light / fan / bell point controlled by one switch drawn through in and including stove enamelled steel conduit with and including all stove enamelled fittings such as elbow, bends, junction boxes, supporting clamps for proper hanging arrangements made out from 20x1mm flat aluminium patti including nuts, bolts and bending to shape etc., of appropriate size but not less than 20mm width on surface with two run sof PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sq.mm nominal cross sectional area 1100 volts grade and including one run of 1.5 sq.mm (green colour) PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire including suitable size sunken type/ surface type terminal boxes made out of 1.6 mm thick galvanised pressed sheet steel with 3 mm thick laminated hylum sheet for mounting switches, sockets etc., and making good the disturbed wall and painting the same with matching colour of the existing wall, including all required materials complete all as specified and as directed.
All as per Srl Item No. 93 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl Item No. 93 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All a s per Srl Item No. 93 above but point wiring for one five pin switch socket outlet combination, 15 Amps & 5 Amps (independent) with using 2.5 sq,mm two run and one run 2.5 sq.mm (nominal area) stranded copper conductor (FRLHS), all as specified and as directed.
Supply and fix switch piano flush type, 5 Amps, single pole, one way, 230 volts, AC circuit complete all as specified and as directed.
Supply and fix socket outlet, five pin, 5 Amps, flush type, multi purpose, 230 volts AC circuit complete all as specified and as directed.
Supply and fix switch piano flush type, 15 Amps, single pole, one way, 230 volts, AC circuit complete all as specified and as directed.
Supply and fix socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type, 230 volts AC circuit complete all as specified and as directed.
Supply and fix ceiling rose PVC / polycarbonate, isolated body, three terminals, complete all as specified and as directed.
Supply, fixing, connecting and testing in replacement industrial single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 V, AC, ‘C’ curve, 10 KA complete all as specified and directed”
Supply, fixing, connecting and testing in replacement industrial triple pole and earth enclosure with a three pin and earth with socket complete with one triple pole MCB TP 20 Amps, 415 V, AC, ‘C’ curve, 10 KA complete all as specified and directed.
Dismantling and taking out old unserviceable copper/aluminium sub main wiring / unarmoured cable (used as sub main wiring) from any height, any size and core with all connecting accessories including conduit or casing caping making good to the disturbed wall and painting the srea to match with existing wall including materials complete all as specified and as directed.
Material and labour sub main wiring at any height using two single core PVC insulated unsheathed copper conductor cable (FRLSH) of size 1.5 sq.mm 1100 volts grade drawn through and including new steel conduit of suitable size including 1.5 sq.mm PVC multi stranded copper conductor cable (FRLSH) in green colour for continuous earthing fixed on wall / roof / angle iron channel with necessary mounting arrangements all as specified and as directed. NOTE :- Two runs of 1.5 sq.mm cable one run of 1.5 sq.mm earth continuity wire and steel conduit shall be measured as one length.
Material and labour sub main wiring at any height using two single core PVC insulated unsheathed copper conductor cable (FRLSH) of size 2.5 sq.mm 1100 volts grade drawn through and including new steel conduit of suitable size including 2.5 sq.mm PVC multi stranded copper conductor cable (FRLSH) in green colour for continuous earthing fixed on wall / roof / angle iron channel with necessary mounting arrangements all as specified and as directed. NOTE :- Two runs of 2.5 sq.mm cable one run of 2.5 sq.mm earth continuity wire and steel conduit shall be measured as one length.
Material and labour sub main wiring at any height, surface type, using two single core PVC insulated unsheathed copper conductor cable (FRLSH) of size 4.0 sq.mm 1100 volts grade drawn through and including new steel conduit of suitable size including 4.0 sq.mm PVC multi stranded copper conductor cable (FRLSH) in green colour for continuous earthing fixed on wall / roof / angle iron channel with necessary mounting arrangement all as specified and as directed. NOTE :- Two runs of 4.0 sq.mm cable one run of 4.00 sq.mm earth continuity wire and steel conduit shall be measured as one length.
Dismantling and drawing out old unserviceable sub main aluminium / copper wiring from existing steel / PVC conduit of any size and any type from any height with all connecting accessories (excluding steel /PVC conduit) and making good the disturbed wall and painting the same to match with the existing wall all as specified and as directed.
Material and labour for sub main wiring at any height using two single core PVC insulated copper conductor cable (FRLSH) of size 1.5 sq.mm, 1100 volt grade drawn through existing surface/recessed Steel/ PVC conduit including 1.5 sq.mm PVC multi stranded copper conductor cable (FRLSH) in green colour for continuous earthing all as specified and as directed. NOTE :- Two runs of 1.5 sq.mm cable and one run of 1.5 sq.mm earth continuity wire shall be measured as one length.
Material and labour for sub main wiring at any height using two single core PVC insulated copper conductor cable (FRLSH) of size 2.5 sq.mm, 1100 volt grade drawn through existing surface/recessed Steel/ PVC conduit including 2.5 sq.mm PVC multi stranded copper conductor cable (FRLSH) in green colour for continuous earthing all as specified and as directed. NOTE :- Two runs of 2.5 sq.mm cable and one run of 2.5 sq.mm earth continuity wire shall be measured as one length.
Material and labour rolled mild steel as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, at any height, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint for mounting air circulator / exhaust fan / ceiling fan / high bay fittings etc for fixing arrangements complete all as specified and as directed.
Disconnecting and taking down old existing damaged metallic rigid steel conduit of any size and any type from any height with all fittings complete.
Supply and fix hot galvanised rigid steel conduit of 25 mm dia, stove enameled , at any height with and including of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, screws, clips, plugs, clamps etc. for securing cables, battens, conduits etc. to walls, steel joints etc. complete to be fixed on wall/ceiling/MS angles all as specified and as directed.
Supply and fix hot galvanised rigid steel conduit of 20 mm dia, stove enameled, at any height with and including of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, screws, clips, plugs, clamps etc. for securing cables, battens, conduits etc. to walls, steel joints etc. complete to be fixed on wall/ceiling/MS angles all as specified and as directed.
Dismantling and taking down unserviceable light fitting of any type from any location / height after disconnecting of electrical connections complete including all connected accessories all as specified and as directed.
Supply and fix LED luminaire 2’X2’, 35/36 W, 220 V, AC, recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holder and LED lamp suitable for roof celling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. MAKE :- Halonix Cat No HLFPS22-02-36-CW-R-HLI/ Bajaj Cat No BPRF 36W WHSL LED/Havells Cat No VENUSNEO2X2PLR36W LED 865G2
Supply and fix LED light fitting1X20 W, 220 V, AC, decorative box type complete with driver, holder and LED tube light including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. MAKE :- Halonix Cat No HLB-03-20-CW-AL-SQ/ Bajaj Cat No BCLAB 20W LED P / Havells Cat No LUMILINEPLUS NEO BS 20W LED 865SPCSSIND.
Supply and fix at 5 to 9 mtr height 120 Watt industrial LED highbay luminaire with > 100 Lm/W, with complete all accessories having IP 66 degree of protection, power factor >0.95, THD<10%, potted driver, internal surge protection-4KV & xternal Surge Protection-10KV, LED source including safety chain with i bolt complete all as specified and as directed. MAKE :- Surya Cat Part No. SLE HB 120W COMET NEO-N or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix exhaust fan, steel body, AC, single phase, 230/ 240 volts of size 450 mm sweep with blades, frames & louvers complete with bird screen protection including fixing / grouting of frame in wall and cutting opening embedded complete and connecting with and including 3 core, 1.5 sq.mm PVC insulated cable with multistranded copper conductors from ceiling rose to fan all as specified and as directed.
Supply and fix ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 Volts,1400mm sweep with min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) including provision of cable from ceiling rose or connector to fan, anchor bolt for fixing of ceiling fan complete all as specified and as directed.
Supply and fixsheet metal enclosure MCB SPN DB 12 way, 230 V, AC, double door, flush / surface type with 200 A rated bus bar complete all as specified and as directed.
Supply and fix sheet metal enclosure MCB SPN DB 08 way, 230 V, AC, double door, flush/surface type with 200 Amps rated bus bar complete all as specified and as directed.
Supply, fix, connecting and testing of VTPN DB, 04 way suitable for MCCB as incomer and SP MCB as outgoing made of high quality CRCA sheet, powder coated, IP 43 protection, isolated neutral bar, insulated bus bar assembly complete all as specified and as directed. MAKE :- Indoasian Cat No 811888P or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix MCB SP 6 to 32 Amps, 10 KA ‘C’ curve, 230 V, AC complete all as specified and as directed.
Supply and fix MCB SPN 6 to 32 Amps, 10 KA ‘C’ curve, 230 V, AC complete all as specified and as directed.
Supply and fix MCCB 100 Amps, 4 pole, 415 V, AC with braking capacity 25 KA, Ics= 100% Icu complete all as specified and as directed MAKE :- Indoasian Cat No 830272 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix MCCB 63 Amps, 4 pole, 415 VAC with braking capacity 16 KA, Ics= 100% Icu complete all as specified and directed MAKE :- Indoasian Cat No. 830240 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix air termination rod at any height, single pointed, aluminium rod 19 mm dia and 600 mm long to be screwed and sturdily fixed to GI pipe of 40 mm dia with and including two no sets of suitable size nut, bolt, washers (02 Nos.) including dismantling of old unserviceable one all as specified and as directed. NOTE - PCC block and GI pipe required shall be measured and paid separately under relevant items of BOQ.
Supply and fix aluminium strip at any height of size 25 mm x 3.15 mm to procelain insulator with suitable saddles, fixing screws etc., on roof or on wall (upto appx. 35 feet above GL) including of bitumen washers, nuts, bolts, etc. required to fix the strip on existing serviceable or new insulators including dismantling of old unserviceable strip complete all as specified and as directed. NOTE :- Cost of suitable fixing jobs like drilling, welding, etc., required for fixing of strip and insulators on the any existing surface like PCC wall, asbestos sheet, etc. at site is deemed to be included in the quoted rate.
Material and labour for fixing and connecting in replacement test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25 mm thick drilled and screwed including 03 Nos 8 mm dia 25 mm long hexagonal head screws fixed to GI strip bracket fixed to porcelain insulator on wall as in repairs, including dismantling of old unserviceable complete all as specified and as directed. NOTE :- Porcelain insulator will be measured and paid separetely.
Supply and fix of vitreous china porcelain insulator, white, with busbar supports, fixed on wall or on roof (upto 35 feet above GL) for fixing of any type of earth continuity strip including dismantling of old unserviceable complete all as specified and as directed. NOTE :- Cost of suitable fixing jobs like drilling, welding, etc. required for fixing of strip and insulators on the any surface at site is deemed to be included in the quoted rate.
Material and labour for earthing complete with hot dip galvanized steel pipe in pipe electrode, outer pipe 76mm dia medium grade and inner pipe 55 mm dia including testing, 3 mtr long and having 50x6 mm terminal on inner pipe to connect earthing strip with 14 mm holes for nut bolts, buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and 3.3 mtr deep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with galvanized steel earthing lead of 32x6 mm strip with minimum two Nos of GI nut bolts and connected to test point from earthing pit, area between pipes filled with dry type chemical powder, the electrode pipes should be filled with 2x 25 kg bags of carbide based BFC earthing compound, the resistance of the compound should be less than 0.1 Oms, the compound should be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities with Ph value between 7-9. connected to the earthing test point, fiber reinforced FRP pit not less than 300x300x240 mm with pit cover, including necessary returning filling and removal of extra soil, to achiev earth resistance value less than 5 Ohms including testing complete all as specified and as directed. MAKE :- U-Protect or techno commercially equivalent model in makes as per Appendix 'C'. NOTE: If the desired result not obtained after testing, the contractor shall do re-eathing without any extra cost.
Supply and fix in replacement of GI strip 32 mm x 6 mm to be buried in ground /wall as earth continuity conductor to be fixed from test point to test point including dismantling of old unserviceable complete all as specified and as directed. NOTE :- Rate for Earth work required shall be deemed in quoted rate.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core fixed on wall / laid in existing trenches etc.,complete all as specified and as directed.
Supply and fix LED street light fitting, 20 Watt 230 V, AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 / 66 protection including connecting with 1.5 sq.mm copper conductor 3 core flexible cable from fitting / connector to ceiling rose and fix on wall with clamps & nut bolts and necessary GI bracket made of 32 mm light grade GI pipe of 1 mtr length with necessary bending complete all as specified and as directed . MAKE :- HALONIX Cat No HLSLD-14-20-CWDL-R / Bajaj Cat No ENXT P 20L WH PO PC SD / HAVELLS Cat No ENDURASUNDOWNSL25WLED765PASYBOPCIHD.
S S ENTERPRISES
vishalconstruction
R J ENTERPRISES
the bhimani group of companies
UNIQUE ENGINEERS
OM INFRA
VIRENDRA FABRICATORS
United Sales Corporation
SHUBHAM SHANKAR GAIKWAD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .