Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-Finance D NO 32 1 211 2 BOWDARA ROAD VISAKHAPATNAM 530004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | L1 | Accepted-Finance Admitted being the lowest | |
| 2 | L2₹22.4 L+₹62,096 (2.85%)Rejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | L2 | Rejected-Finance L1 BEING ACCEPTED | |
| 3 | L3₹22.4 L+₹63,995 (2.94%)Rejected-Finance NO 12 25 26 KATHIRAVAN NAGAR MAHALINGAPURAM PO POLLACHI COIMBATORE 642 002 | COIMBATORE | TAMIL NADU | 642002 | L3 | Rejected-Finance L1 BEING ACCEPTED | |
| 4 | L4₹23.3 L+₹1.5 L (6.93%)Rejected-Finance | L4 | Rejected-Finance L1 BEING ACCEPTED | |
| 5 | L5₹25.0 L+₹3.2 L (14.8%)Rejected-Finance N NO 6 OLD NO 10 1ST STREET KASTHURI BAI NAGAR AVADI CHENNAI 600054 | CHENNAI | CHENNAI | TAMIL NADU | 600054 | L5 | Rejected-Finance L1 BEING ACCEPTED |
Tender Value
₹35.1 L
EMD Value
₹70,300
Closing Date
23 Jan 2024, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I) (CG) Military Engineer ServiceCGRA Meenambakkam Building No P 16 NGO Colony 4th Street Nanganallur Chennai 600 061
PROVISION OF HIGH MAST LIGHTS AT ICGS KARAIKAL UNDER GE(I) CG CHENNAI
2024_MES_636247_1
8097/E8/GE(I)CHENNAI
Open Tender
Civil Works
Item Rate
240 days
KARAIKAL
All as per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹70,300
Yes
20 Feb 2024
11 Jan 2024
25 Jan 2024
11 Jan 2024
23 Jan 2024
18 Jan 2024
Amount
Supply, Install, test and commissioning of 16 M High galvanized mast light in two section suitable for 47 m/sec wind speed alongwith head frame , luminiares carriage suitable for 6 luminiaries in symmetrical arragement and other accessories manufactured in factory with raising double drum winch, 6 mm diameter SS wire rope, trailing cable, connector, intergal power tool motor, manual handle , junction box , lighting finial , wiring material from JB to individual luminiare & MCB in base compartment are as part of installation, foundation bolts manufactured from special steel along with nuts , washers , anchor plate and common template and outdoor stand mounted feeder pillar box speificfied here in after complete all as specified and as directed. Make : Crompton / Bajaj Electricals Ltd/ Wipro/Philips/Havells . Note: The rates quoted by the tenderer shall be deemed to be inclusive of formowrk, Earth work and RCC foundation concrete and external finishes including other unforeseen itmes all as specified by Engr-in-charge.
1. High Mast Structure. a. Height of Mast (Mtrs). : 16 b. Material of Construction. : BS EN 10025 / IS 2062 c. Thickness of Material i. Top Section. : 3 mm ii. Bottom Section. : 4 mm d. Cross Section of Mast (Number of Sides) : 20 Sided Polygon e Length of Individual Section. i. Top Sec. : 8.250 Mtrs ii. Bottom Sec. : 8.250 Mtrs f. Base & Top Diameter i. Base Dia. : 360 mm (Approx.) ii. Top Dia. : 150 mm (Approx.) g. Type of Joints : Stress Slip Fit Joints h. Length of Overlap. : 1.5 times the Dia. of Insertion i. Metal Protection Treatment : Hot Dip Galvanised as per IS 4759/ IS 2629 j. Thickness of Galvanisation. : Average 70 Microns k. Size of Door Opening at Base of Mast. : 1200 mm X 250 mm l. Type of Locking on Door Panel. : Close fitting door with Allen Key, locking with suitable reinforcement to avoid Buckling at Base of Mast. m. Lighting protection finial : GI single spike of Length 1200 mm n. Size of Base Plate. i. Diameter. : 540 mm ii. Thickness. : 30 mm
2. Dynamic Loading as Prevailing At Site. a. Maximum Wind Speed ( IS 875 - 1987 ) : 47 m/s b. Number of Foundation Bolts. : 08 Nos c. PCD of Foundation Bolts. : 445 mm d. Diameter of Foundation Bolts. : M30 e. Length of Foundation Bolts : 850 mm 3. Lantern Carriage. a. Material of Construction. : 40 NB ERW Class B- M.S Pipe b. Diameter of Lantern Carriage Ring. : 600 mm (ID) c. Construction. : 06 Arm Welded d. Number of Joints. : 2 Segments e. Load Carrying Capacity. : 6 Luminaire , Symmetrical 4. Winch. a. Number of Drums Per Winch. : Double Drum. b. Gear Ratio. : 50 : 1 c. Capacity : SWL 500 Kgs. d. Method of Operation. : Motor OR Manual. e. Lubrication Arrangement. : Self Lubricating in Permanent Oil Bath f. Type of Lubricant. : SAE - 90 / 140. 5.Stainless Steel Wire Rope a. Grade : AISI 316. b. Diameter of SS Rope : 6 mm c. Construction of SS Rope : 7 / 19. d. Number of SS Ropes : 3 Nos of 6 mm for Lantern Carriage.: 2 Nos of 6 mm for Double Drum Winch
e. Thimbles & Terminals. : Provided. f. Breaking Load Capacity. : 2350 Kgs Per SS Wire Rope 6. Trailing Cable. a. Type : Flexible Copper 5 Core 2.5 Sq mm b. Material. : EPR Insulated PCP Sheathed c. Make .: I.S. Approved Brand. d. No.of circuits per mast : One 7. Power Tool. a. Model. : Integral b. Capacity(HP) : 1.5 HP c. Number of Speeds. : Single Speed. d. Reversible / Non - Reversible. : Reversible. e. Input Supply. : 415 Volts
Note for item No: 01 :Foundation shall be provided as per manufacturer design to withstand the wind velocity & soil condition and foundation diagram/design shall be got approved by Accepting officer before commencement of work.
Supply , lay and test cable in trenches XLPE insulated screend PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of 25 sqmm, 4core including jointing and jointing material complete all as specified and as directed. Make : Gloster/CCI/Universal/Havells/Finolex Note: Excavation and earth work, cable cover, sand cusioning shall be measured and paid seperately
Supply , lay and test cable PVC insulated screend PVC bedded galvanized steel strip or wire unarmoured, electric control cable (heavy duty) 1100 volts grade with stranded copper conductor of 2.5 sqmm 2 core including jointing and jointing material complete all as specified and as directed. Make : Gloster/CCI/Universal/Havells/Finolex
Supply , lay and test cable PVC insulated screend PVC bedded galvanized steel strip or wire unarmoured, electric control cable (heavy duty) 1100 volts grade with stranded copper conductor of 2.5 sqmm 3 core including jointing and jointing material complete all as specified and as directed. Make : Gloster/CCI/Universal/Havells/Finolex
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth for taking out / laying under ground cables/pipes etc and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth for taking out / laying under ground cables/pipes etc and getting out in hard/dense soil complete all as specified and as directed.
Returning fillingin, including spreading levelling, watering and well ramming in layers n-exc 25 cm in soil complete all as specified and as directed.
Removing excavated soil to a distance not exc 50 metre and depositing where directed at a level n-exc 1.5 metre above the starting pointcomplete all as specified and as directed.
Supply and spread clean M-SAND in trenches including levelling, punning for cushioning of cables complete all as specified and as directed. Note : Punned thickness of sand cushioning shall be measured.
Supply and lay in trenches dry fly ash bricks for cable protection keeping width of the brick parallel to the length of the cable complete all as specified and as directed.
Supply and fix tubes light grade ,galvanised ,50 mm dia with all fittings for cable protection,laid in trenches /fixed on wall,floors etc complete all as specified and as directed. Make : Tata/Jindal/ Zenith
Cutting road of concrete in ground floors and pavings n exc 15 cm thickness below ground level all as directed.
Material and labour for PCC 1:2:4 type D-1 using 40 mm graded aggregate for filling and foundation concrete including necessary form work complete all as specified and as directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanised iron strip 32x6 mm by means of bolts, nut, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earth test point including excavation, earth work in any type of soil, PCC Chamber 1:2:4, B1 type and precast RCC cover slab 50 mm thick with RCC 1:2:4 type B1 using 20mm graded stone aggregate and 8mm CTD bar 150c/c both ways funnels, watering pipe 20mm dia GI medium grade,wire mesh, GI Protection pipe 40mm dia light grade connecting test point and testing on completion and as directed. Note:-The rate quoted is inclusive of GI strip 32x6 mm earth conductor upto a length of 7.5m from the earth pit.
Supply & fixing of LED type single dome aviation obstruction light complete all as per directed.Make : Crompton / Bajaj Electricals Ltd/ Wipro/Philips/Havells .
Supply & fixing of 200 W LED Flood light luminaries, Fixture housing with Die cast. Fixture Cover Clear Heat resistant Toughened glass with silicon gaskets for IP66protection. LED Fixture along with cradle. System Lumen output >=110 lumen per watt. High purity PMMA individual lenses for superior performance and beam angle 60 deg. CCT5700K and CRI >70. LED High-power and LED life of 50,000burining hours as per L70 criteria. LED driver designed 4Kvsurge protection and 10KV for System. BIS approved isolated type, multistage constant current topology potted driver with>85% efficiency. The luminaire shall be with >0.95 PF and THD<10%. LEDs comply to the Photo biological safety standards as per IEC62471. Make: Crompton/havells/Bajaj/Philips,
LAKSHMI ELECTRICAL ENTERPRISES
Rajapriyaconstruction
P.Murugesan
Sri Lakshmi and Company
LEOENTERPRISES
NAVEEN ENTERPRIESES
Standard enterprises
kvs constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .