Loading…
Loading…
Tender Value
₹12.7 L
EMD Value
₹31,770
Closing Date
25 Sept 2026, 4:00 pmClosed
North Western Karnataka Road Transport Corporation
Divakar S Yaragoppa
Providing metering cubicle replacing of old service mains and UG Cable for providing power supply to the commercial shops at New Bus station at Dharwad.
NWKRTC/2026-27/EL/WORK_INDENT98
NWKRTC/2026-27/EL/WORK_INDENT98
Open
Electrical
Two Tender Document System(Two Cover)
North Western Karnataka Road Transport Corporation Head Office
3 documents required · 3 mandatory
To Qualify for award of this contract, the Tenderer must have appropriate valid Class - I Licensed Electrical Contractor (LEC), issued by the Electrical Inspectorate Govt. of Karnataka, as on the Date of Tender Notification. Scanned copy of valid Electrical Contractor license, issued by the Electrical Inspectorate Govt. of Karnataka.
To qualify for award of this contract, the tenderer must have a financial turnover Certificate. Scanned copy of year wise financial turnover. (Certified by Chartered Accountant only. Statement issued by others will not qualify for eligibility).
not applicable
not applicable
To Qualify for award of this contract the assessed available tender capacity of the tenderer should be more than the amount put to tender. Note: The bid capacity of the tenderer is calculated based on the formula. Assessed Available Tender Capacity : ( (A X N x 2.5) - B) Where A : Maximum value of Civil Engineering works, updated to 2025-26 price level, executed in any one year during the last five years.( Completed as well as works in progress ).B : Value at 2025-26 price level of existing commitments and ongoing works to be completed during the next two years. N : Number of years prescribed for completion of the work for which tender is invited.2.5 : Multiplying factor for assessing the available tender capacity for works costing upto Rs.100.00Lakhs. The Bidder/Contractor must upload the Scanned copy of details of existing commitments and ongoing works to be completed in the prescribed format only (Annexure-B) duly signed. In case the Bidder does not have any existing commitments, the same should be indicated as NIL in the prescribed format, duly signed. Details uploaded in any other format or uploaded documents in which the Bidder himself has calculated the Bid capacity will not be considered for evaluation and also will not qualify for eligibility.
₹500
₹31,770
10 Sept 2026
10 Sept 2026
28 Sept 2026
17 Sept 2026
Providing metering cubicle replacing of old service mains and UG Cable for providing power supply to the commercial shops at New Bus station at Dharwad.
Internal Wiring: Open Conduit System, Supplying heavy gauge PVC conduit pipe 19/20mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste...
Supplying heavy gauge PVC conduit pipe 25mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and fixing using inverted wood pl...
Supplying PVC/GI flexible conduit pipe 25 mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge ...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed ...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed ...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed ...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed ...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed ...
Control Switch Gears & Accessories: Fabricating supplying and mounting MS box made out 16 SWG suitable for floor /wall mounting, fully weather proof with provision f...
Supplying 100 A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, ...
Supplying 100 A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, ...
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then ...
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V. CSR 2023-24, Volume-6, Part-III ,Utilizat...
Supplying & fixing & Wiring Electronic Trivector (ETV) 5 to 20 A Single phase Class-I Accuracy with tamper Proof Energy Meter.(HESCOM APPROVED). Csr 2023-24,VOL-VI, SRP 19 of 105 / 5-30
Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. CSR 2023-24,Volume-VI,SRP 19 of 105/ 5.35
Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32 Amps fuse cutouts. 2023-24,Volume-VI,...
Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 19 of 105, 5.34
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for ...
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, d...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle...
Supplying of on load changeover switches 4poles,AC-23ADuty, 415V, 50Hz, ACSupply. Withallaccessories. (SM Enclosure Sheet Metal Execution) CSR 2023-24,Volume-VI,SRP 17 of 105/ CSR 2023-24,Volume-VI...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, e...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, e...
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and feetCfeet Type curve, indicator ON/...
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and feetCfeet Type curve, indicator ON/...
L.T.Underground Cables: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistiv...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.
Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, pla...
Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, . In Hard Soil. ...
Cutting of Road surface for cable trenches and disposing of the excavated earth, as directed including Barricading, Danger Lighting then Refilling the Cable Trench...
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT Cable: 2.5 to 25 SQmm. CSR 2023-24, Volume-6,...
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT Cable: 35 to 95 SQmm. CSR 2023-24, Volume-6, ...
Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting sockets /Couplings /Tees / Bends /End caps of same materials in existing trench as per IS 14930 part-II s...
Digging of Pit for providing GI Pipe type Earthing. Hard Soil. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 43 of 81, 22 / 1.6.2.
GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg. CSR 2023-24, Volume-6, Part-III ,Utilization, ...
Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 22 of 81, 390 / 51.02
Good Quality Salt for grounding purposes packed in 50 Kg gunny bag. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 22 of 81, 391 / 51.03.
Providing Laying & Fixing of G I Pipes confirming ti IS:1229-1990 with latest amendments completewith G I Fittings ( excluding cost of fittings) with cuts & Threads wherever necessary including testin...
GI/Copper strips for grounding connections,using necessary fixing materials as required. 600X600X3mm Copper plate. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 55 of 105, / 12.58.11.
Supplying & fixing of DANGER BOARD made out of MS sheet metal with two coats of non corrossive enamel paint. CSR 2023-24/ SRP 13 COST DATA SHEET-1/14 ( Material Cost Rs:131-00+ Labor Cist Rs:71-00 = ...
Supplying & Installation of RUBBER MAT 1mt X 1 mt-10mm thick. Complete including cost of materials. Labour, usage charges of machinaery complete as per specifications. CSR 2023-24,COL-6, SRP 93 of...
Engaging Skilled electricians for repairingElectrical faults , and other allied works ,
PWD CSR 2023-24 .SL.No.II/6.67.Page No.A-49, Rs: 742.86/Per day.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Annexure B Bid Capacity.doc
Others - Annexure B Format • 0.03 MB
Tender notification Dharwad NBS Electr.docx
Instructions to Tenderers • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .