EE RWS ZP KOLHAPUR
EE RWS ZP KOLHAPUR
DETAILED ESTIMATE OF CIRCULATING FLUIDIZED BED BIO-REACTOR (PRE-FAB STP) 25 KLD AT NRUSINH-WADI. TAL SHIROL DIST - KOLHAPUR.
2025_KOLHA_1243267_5
28/2025-26
Open Tender
Civil Works - Water Works
Percentage
365 days
AT PACHGOAN TAL KARVEER DIST - KOLHAPUR.
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,900
₹29,298
Yes
22 Dec 2025
22 Dec 2025
2 Jan 2026
22 Dec 2025
2 Jan 2026
22 Dec 2025
Sub Work No. 1 :- Prefab Sewage Water Treatment Plant - 25 KLD Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete.
Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 1/259) Lift 0 to 1.50 M
Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) Lift 0 to 1.50 m 0 to 1.50 m depth
Below 1.50 m depth
Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264)
Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags /cum) Spec. No. - Bd E /1, Page No. 287 and B-7, Page No. 38 b) In PCC M-100
Filling in plinth and floors / trenches with contractor's murum for bedding in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-11/263)
Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, anikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) c) In RCC M - 250
Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) RCC PARDIES c) In RCC M - 250
Providing and casting in situ Cement Concrete of trap/ granite / quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineerincharge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) For all types of Columns c) In RCC M-250
Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) For Beams c) In RCC M-250
Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) For Slab c) In RCC M-250
Providing and laying Cast in situ/ Ready Mix cement concrete in M-20 of trap /granite /quartzite /gneiss metal for R.C.C. coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, coverblocks, laying/pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Typemixer/ concrete Batch mix plant (Panmixer) etc.complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F- 17/306) b) Tor Steel
Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd- A-9/261)
Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using water proofing compound at 1 Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
Providing and Fixing Sewage Equalization Tank of rectangle shape as per site condition , capacity 5-6 M3, Retention is 6-8 Hours Average Flow,and Air Grid with Minimum storage of of 3 hours at peak flow while pumping. Once submersible pump as per schedule shall be provided with level switch control., aeration tank immersed Piping Minimum storage of of 3 hours at peak flow while pumping. Once submersible pump as per schedule shall be provided with level switch control., aeration tank. As per Approved Quotation
Providing and Fixing Inlet manual bar screen, size 500 X 750 mm of Aarvi Energy, inlet bar screen provide in and fixing in the bar chamber of equailization tank as per instruction of incharge. - As per Approved Quotation
Providing and placing in oil Skimmer of Belt type 50 mm wide, having capacity 2.5 LPH as per instruction of incharge. - As per Approved Quotation
Providing and fixing Equailized water transfer submersible pump having capacity 1.5 to 3.0 m3/Hr having cast iron Impeller/shaft:SS304 as per instruction of incharge. - As per Approved Quotation
Providing and fixing fine screening system (rotating drum type fine screen) of size 0.50 M3/Hr. of 0.25 HP motor. as per instruction of incharge. - As per Approved Quotation
Providing and fixing Rectangular shape Aerobic tank having capacity 6 M3 of propeller SS304 type 7.5 HP mixer.as per instruction of incharge. - As per Approved Quotation
Providing and fixing Rectangular shape Aeration Cum Fluidized Bed Reactor Tank having capacity 6 M3, size as per site condition and as per instruction of incharge. - As per Approved Quotation
Providing and fixing Air Blower for Equilization Tank, Aeration Tank with Fluidized Bed Reactor Tank having capacity 50 M3/Hr , as per site condition and as per instruction of incharge. - As per Approved Quotation
Providing and fixing Rectangular shape type Separation Tank having capacity 3-4 M3/Hr with tube media, as per site condition and as per instruction of incharge. - As per Approved Quotation
Providing and fixing Rectangular shape Collection tank with fludization 2 M3 , as per site condition and as per instruction of incharge. - As per Approved Quotation
Providing and fixing Mechanical Centrifugal type Permeate Pumps 2-3 M3/Hr , as per site condition and as per instruction of incharge. - As per Approved Quotation
Providing and fixing Sludge recirculation Pump having capacity 2-3 M3/Hr with diffuser 90 X 1000 mm, as per site condition and as per instruction of incharge. - As per Approved Quotation
Providing and fixing Electronic solenoid operated, wall or base mounting chlorination System integrated UV disinfection system as per site condition and as per instruction of incharge. - As per Approved Quotation
Providing and fixing Electronic solenoid operated, wall or base mounting Chemical and Dosing System as per site condition and as per instruction of incharge. -As per Approved Quotation
Providing and fixing Drum type autocut off system with 2 HP drum type centrifuge, with hypo chlorination system as per site condition and as per instruction of incharge. - As per Approved Quotation
Providing and fixing mild steel grill railing weighing 15 Kilogram / One Square Metre. with PVC handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete/ other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing PVC handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, etc. complete. Spec. One Number : As directed by Engineer in charge.
Providing and fixing 45 cm wide mild steel ladder of 40 mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 cm x 30 cm x 30 cm and painting the ladder complete. (AntiCorossive Paint)
Providing, laying and fixing P.V.C. pipe of 25 mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing, laying and fixing P.V.C. pipe of 40 mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing 90 cm x 60 cm Granite plate engraving 10 cm. Height letter, figures including painting the lefters /figures with approved colour and shade complete
Structural Engineering charges (3% RCC & Steel Work Amount)
Sub Work No.2- Solar Power System PART-A Supplying, installing, testing and commissioning of 5 kWp ON-GRID Solar PV Each System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 15 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 years including net charges for RMS system, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
PART-B Solar PV mounting structure hot deep galvanized/pre galvanized with necessary fitments which should withstand high wind velocity upto 150km/hr Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259).
Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259)
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below,stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 4/259)
Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. (Bd-A- 5/259)
Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) Soling
Providing and laying in situ Cement Concrete M15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) PCC-M15
Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) RCC-M20 Footing
Providing and casting in situ Cement Concrete of trap/ granite / quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineerin- charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Column
Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineerincharge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Beam
Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (BdF17/306) c) Corrosion Resistant Steel (Fe 500)
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)
For structure Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates, etc. as per detailed design and drawing or as directed by Engineer-in- charge including cutting, fabricating, hoisting, erecting and fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd-C-8/278)
For structure (LESS Painting Charges) Providing and applying two coats of oil paint and one coat of primer/red oxide of Iron Paint externally including cleaning the surface of pipe with steel scrapers wire brushes and metal cleaning solution etc complete.
For structure Providing and applying material & labour for hot dip galvanizing of above structure including transportation for galvanizing as per R.C
For structure- Transporting charges of vehicle per trip for Appox. 50 km ead including loading unloading & stacking charges.
Rent for Crane for erection of structure-
Providing and erecting chain link fencing 1.6M. height with G.I. chain link of size 50x50mm, 8gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40x40x6 mm size, including excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450x450x670 mm. at 1.75M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25x25x5 mm size and vertical M.S. flat 35x5 mm and 25x5 mm horizontal including cross support of 40x40x6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450x450x670 mm including 3 coats of oil painting etc.complete.
Providing and fixing 50mm. dia. medium class G.I. pipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in c.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.68 MB
NIT.pdf
Tender Documents • 2.53 MB
SBD.pdf
Other Document • 1.35 MB
BOQ_2175268.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .