Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 CrAdmitted-Finance B B ROAD BARPETA ASSAM | BARPETA | ASSAM | 781301 | ₹13.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹15.5 CrAdmitted-Finance | ₹15.5 Cr | L2 | Admitted-Finance |
| 3 | L3₹15.7 CrAdmitted-Finance BHETAPARA CHARIALI ABOVE UCO BANK GUWAHATI 781028 | GUWAHATI | KAMRUP METRO | ASSAM | 781028 | ₹15.7 Cr | L3 | Admitted-Finance |
| 4 | L4₹16.0 CrAdmitted-Finance GORUBANDHA MISSAMARI 784 506 | SONITPUR | ASSAM | 784506 | ₹16.0 Cr | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Macrocosm Builders L1 | M/S SUNRISE ENTERPRISE L4 | M/S MAQ INFRA PROJECTS L2 | M/S MAYUR ASSOCIATES L3 |
|---|---|---|---|---|---|---|---|
| 1.01 | Karimganj DH Total Value | 1 | Nos | 13,29,89,999.68 ₹13.3 Cr | 16,00,57,461 ₹16.0 Cr | 15,50,46,242.55 ₹15.5 Cr | 15,72,12,762.38 ₹15.7 Cr |
Updated dates
Tender Value
₹18.0 Cr
EMD Value
₹36.0 L
Closing Date
28 Jan 2026, 2:00 pmClosed
Project Director
Sixmile, Khanapara, Guwahati - 781022
Repair and renovation work in Karimganj Civil Hospital, Sribhumi, Assam under ASSIST project
2025_MDRDE_49287_1
IN-AHIDMS-526826-CW-RFB
Open Tender
Civil Works - Building
As per bid document
Please refer Tender documents.
4 documents required · 4 mandatory
₹20,000
₹36.0 L
Yes
13 Mar 2026
16 Dec 2025
28 Jan 2026
17 Dec 2025
28 Jan 2026
12 Jan 2026
17 Dec 2025 - 22 Dec 2025
Item Description
Providing and laying non-pressure NP2 class (light duty) R.C.C. Pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
Supply, installation, testing & commissioning of Rubber Bellows on discharge side of pump conforming to EJMA with all hardwares, companion flanges & gaskets, etc.
EARTHWORK
TOTAL AMOUNT Without Taxes
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintellevel with approved block laying polymer modified adhesive mortar allcomplete as per direction of Engineer-in-Charge. (The payment of RCCband and reinforcement shall be made for seperately).
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
80 mm dia.
BASIC RATE In Figures To be entered by the Bidder Rs. P
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
SOLING WORK
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
P.C.C WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
D.P.C work
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
RCC Work
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:
Credit for demolishion of building structure etc. complete and taking away all fetched material out of campus within 30 days after completing demolition part except C&D waste kept for recycling and used the recycle product for non structural work such as in footh path, manhole, lean concrete, filling under plinth, re-filling foundation etc. or as approved by Engineer-in-charge complete in all respect. The serviceable material received from dismanting/demolishing to be kept with executing agency and take away from the site as per direction of engineer-in- charge. Quote the lump sum amount (in minus)
All works above plinth and upto floor V level
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
1.5 m. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil
All works above plinth and upto floor V level
SAND FILLING
Add for using extra cement in the items of design mix over and above the specified cement content therein.
FORMWORK
Foundations, footings, bases of columns, etc. for mass concrete
Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended floors, roofs, landings, balconies and access platform
STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Concrete of M25 grade with minimum cement content of 330 kg /cum
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
BRICKWORK
Centering and shuttering including strutting, propping etc. and removal of form for
Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources)
Cement mortar 1:6 (1 cement : 6 coarse sand)
New work (Two or more coats)
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources)
Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
Providing and fixing TAC approved fire hose cabinet to house fire hydrant & hose, including all other related accerrories fabricated from M.S. sheet (16 Gauge) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated & painted with post office red colour of size as mentioned in drawing (or as approved by the Architect) to house 15 mtr.x2 nos. hoses. The hose box size is 750 mm x 600 mm x 300 mm
DOORS
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
DOORS FITTINGS
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :
Second class teak wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing chromium plated brass handles with necessary screws etc. complete:
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing bright finished brass door latch with necessary screws etc. complete :
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :
Providing and fixing bright finished brass handles with screws etc. complete:
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
STRUCTURAL STEEL WORKS
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
ROOFING
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
PLASTERING
15 mm cement plaster on the rough side of single or half brick wall of mix :
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineerin
Supplying and installing of in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC reflective self adhesive vinyle painted foam board, complete with mirror fasteners.
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineerin
12 mm cement plaster of mix
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
1:6 (1 cement: 6 coarse sand)
Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge.
0.63 mm thick with zinc coating not less than 275 gm/ m²
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineerin
15 mm cement plaster on the rough side of single or half brick wall of mix :
0.63 mm thick with zinc coating not less than 275 gm/m²
1:6 (1 cement: 6 coarse sand)
Fire Man Axe
Effluent Treatment Plant shall include the supply, installation, testing & commissioning of the following items:
PUTTY AND PRIMER WORK
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
EXTERNAL PAINTING
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
INTERNAL PAINTING
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Two coats
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :
WOOD AND STEEL PAINTING
Applying priming coat
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
1:4 (1 cement: 4 fine sand)
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.
80mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
FLOORING & SKIRTING/ DADO
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Pressure Gauge : 0 - 10 kg/sq.cm.
Size of Tile 600x600 mm
Providing and laying Polished Granite stone flooring and tread of steps in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Glazed Vitrified tiles Matt/Antiskid finish of size
Size of Tile 600 x 600 mm
WALL TILES
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
ALUMINIUM DOORS, WINDOWS AND OTHER WORKS
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)
For fixed portion
62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top laye 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
GRANITE FLOORING / ANTISKID TILES
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineerin- charge complete.
PLINTH PROTECTION WORKS
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
FALSE CEILING
RETROFITTING AND WATER PROOFING
Anti-Corrosive treatment on reinforcement Poviding and applying two coats of two component epoxy zinc rich primer like Fosroc Nitozinc Primer or equivalent on the properly cleaned reinforcement after the required chipping and cleaning of the concreate surface as per the manufacture’s specification at a dry flim thickness of 40 micron /coat.The epoxy zinc rich primer should have a adhesive bond strength with steel greater than 1.5 N/Sqm
Epoxy Grout Providing and Sealing the cracks, in the concrete surface, after opening the cracks using suitable tools or saw cut in the crack, and cleaning the interior sides of the crack using sharp tools to remove all loose materials, using two component, high strength, non-sag, epoxy compound Nitobond PC 40 of fosroc make, inclusive of all Manpower, Material and Equipment. Injection Of Low Viscous Resin: BY Providing and grouting the cracks after fixing the injection ports at predetermine locations with the help of suitable injection grouting pumps at suitable pressures using two-component, high strength, low viscous epoxy injection resin system such as Conbextra EP 10 of Fosroc inclusive of Manpower, Material and Equipment". (Mode of measurement: Per litre of grout consumption.
DISMANTALING WORKS
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge
Providing, Supplying, transporting materials, drill
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road markingb paint of superior make as approved by the engineer-in-charge, including cleaning the surface of all dirt, scales, oil, greas and other foreign materials etc. and lining out complete.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Application of Epoxy Bonding Agent Share Anchoring Providing and applying structural grade long pot life epoxy bond coat of Nitobond EP prior to building up of section with any type of mortar/ concrete to ensure bond between old concrete & new concrete by brush application as per the manufacturer’s specifications. (Mode of measurement- per sqm of application of concrete surface )
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Micro Concreting Providing and laying micro concrete up to the required thickness as per the drawing by consultant on the designated area to the prepared slurry tight shuttering with proper shear connector and bonding agent where ever necessary, The fluid micro-concrete repair material shall be a single component, cement based, Renderoc RG or equivalent micro-concrete to which only the site-addition of clean water (and approved graded coarse aggregates where specified) shall be permitted. The micro concrete shall contain no metallic aggregates, or chlorides and shall be shrinkage compensated in the plastic state. The micro concrete in the flow able consistency should achieve a compressive strength of 50 N/mm2 after 28 days at 30C as per BS 4551-80. The unrestrained expansion shall be between 1 - 4% as per ASTM C827-1987. Again as per BS 4551-80 the flexural strength shall not be less than 5 N/mm2 @ 28 days. The micro concrete shall have a coefficient of thermal expansion 10-12 X 10¯6/°C & Thermal conductivity 1.5 W/m°C The mixed density of micro concrete shall exceed 2100-2200 kg/m3 at 27ºC
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge.
WIRE MESH
GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Total Amount without Taxes
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
With 2nd class teak wood beading 62X19 mm
20 mm cement plaster
Salvage
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
Pu Paint
Signage with printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.5cm height letters in red with white back ground. The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points.
LEAD LINE RADIATION DOOR
Providing & fixing of 2mm Lead Lined Radiation Proof Manual Swing door, 40mm Door Blade thickness with high pressure Laminate of 4mm thickness ,2mm thick lead inserts (99.97% pure (min)),1mm thick backer boards. Rubber Gasket seal non particle shredding type, Bottom Drop Seal, Aluminium alloy door Frame with Lead Inserts, Door Handle solid AISI 304 Grade Stainless Steel. (Size-1500x2100)
Providing two coats of White cement putty, Epoxy based primer of Pro Epi Shield Floor Sealer (20 micron), Top coat Aqua green WB PU Finish White (60 micron) to fnishing including scaffolding, Brush, Roller, Sand Paper, Silk Roller & Carring charges etc.
Anodized (AC 15) aluminium tubular handle bar
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Hermeticallysealed HPL OT Door
Mak Health ManualSingle Leaf sliding 100% Hermeticallysealed HPL OT door, door panel 60mmthick, 4mm HPL on both sides of 52mmthick pressure injected High GradePIR(density 45kg/m3) with AnodizedAluminium Door Profile and Rail withSpecial grade self- lubricating PA rollers,Bearings 2X per roller, Bulb &Lip designEPDM gasket with special lower sealing,28dB noise insulation with vision panel of300x300x60mm with 5mm tempered glasson both sides, planks.Size: 1500 x 2100 mm
63 mm to 45 mm size stone aggregate
53 mm to 22.4 mm size stone aggregate
Double Leaf HPL (Pre- Painted Galvanized Steel) Skin Insulated Clean Room Door with 44 mm Door thickness with HPL Skin on both sides with pressure injected High Grade PIR as Door Blade core material with Ano alu Door Frame, Rubber Gasket Non Particle Shredding Type Seal, Drop Seal, Double Insulated Glass Vison panel 300x300mm, Ball Bearing Hinges, Door Closer on active leaf, Door Lock and SS 304 Door Handle D-Type for smooth passage. Size : 1500×2100 mm
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggreg
Supplying and installing of in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC reflective self adhesive vinyl painted foam board, complete with mirror fasteners.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
INTERNAL WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cab
Group C
le etc. as required.
INTERNAL ROAD- PAVER BLOCK
2x2.5 sq.mm + 1 x 2.5 sq.mm earth wire (For 6A Power Point looping & Switchboard to Switchboard looping)
2 x 4 sq.mm + 1 x 4 sq.mm earth wire ((For 6/16A Power Point looping)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with acessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THO less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
EARTHING
Supply and laying of 25mm X 5mm G.I. strip at 0.5 mtr below ground as strip earth electrode including connection/termination with GI Nut-Bolt & Spring Washer etc as required(Jointing Shall be done by overlapping and with 2sets of GI Nut-Bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia. G.I. wire on surface or in recessed for loop earthing as required
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
12way, Double door
Group A
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
6 way (6 + 18), Double door
8 way (4 + 24), Double door
5/6 A switch
4 way (4 + 12), Double door
3 pin 5/6 A socket outlet
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
4 way (4 + 12), Double door
Triple pole
Supplying, installation, testing & commissioning of exhaust fans 300 mm. sweep. 230volt, 50Hz single phase A/C supply and complete with all standard accessories s (As per make list / atrchitect choice)
Supply, installation testing, commissioning of 20W LED TUBE LIGHT including Luminaire housing and all fixing acceessories (As per make list / atrchitect choice)
DIESEL GENERATOR
uld contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:
(A) Diesel Engine: Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.
(B) Engine mounted Instrument Panel fitted with and having digital display for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication (vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level
(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.
(D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
(E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
(F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.
(G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type)as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.
(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.
(I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminum) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the
panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:
15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning 16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date. 18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel, interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.
LAYING OF MV CABLES
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/Metal Pipes as required.
Upto 35 sq. mm
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
3.5C X 300 Sqmm. Al.
3.5C X 70 Sqmm. Al.
3.5C X 35 Sqmm. Al.
3C X 35 Sqmm. Al.
3C X 10 Sqmm. Al.
4C X 16 Sqmm. Al.
4C X 10 Sqmm. Al.
TRANSFORMER
Main LT panel
DG Incomer (From DG Sync. Panel): 1No. 630A, 4P, 36kA Microprocessor based MCCB with over current, short circuit and earth fault release consists of 3Nos. 630/5A, 15VA, CL-1 CT operated Multifunction Meter, 1 set of R,Y,B,ON,OFF,TRIP indication lamps.
Bus Bar 630A, 36kA for 1Sec, TP+N+E Aluminium Busbar. Bus barMounted Surge Protection Devices Type I & II
Department wise marking
Auto Transfer Switch :- 630A
Earthing with G.I. earth pipe 4.5mtr long,40mm dia including accessories and providing masonry encloser with cover plate having locking arrangement and watering pipe etc.with charcoal or coke and salt complete as required (IS : 3043-1987), (Panel earthing + Lightning protection)
Supply, installation testing, commissioning of 12W surface/ recess MOUNTED DOWN LIGHT including Luminaire housing and all fixing acceessories (As per make list / atrchitect choice)
EARTHING
Staircase Arrow Sign - Imported Acrylic Sheet 4mm, grade 1 autoluminscent film, preplotted media with extra over laminate at the back. Size: 6’’ x 4’’
Outgoings: 2 No. 250A, 4P, 36kA Microprocessor based MCCB with all accessories and protection, 4 Nos. 160A, 4P, 25kA Thermal Magnetic based MCCB with all accessories and protection, 4 Nos. 100A, 4P, 25kA Thermal Magnetic based MCCB with all accessories and protection, 5 Nos. 63A, 4P, 25kA Thermal Magnetic based MCCB with all accessories and protection, 1 Nos. 32A, 4P, 25kA Thermal Magnetic based MCCB with all accessories and protection.
TOTAL
3 x 4 sq. Mm ( upto 35 sqmm) additional cable
SUPPLY OF MV CABLES
4 sq. mm. 3 core Cu. Arm. XLPE cable
TERMINATION OF MV CABLES
4 sq. mm. 3 core Cu. Arm.XLPE cable
Litre
SUPPLY OF FEEDER PILLAR, OUTDOOR
INTERNAL PLUMBING
o 99%. Output power factor = 1 Hot-swappable modules. Modular redundancy in N+1 configuration. Intelligence distributed between modules. UPS Power capacity upto 25KW x 3 module Decentralised by-pass. Reduced battery charging times. BMS compatible with open protocol communicable, remote monitoring interface, 30 mins backup ( for 50 KVA) with 12V SMF battery, built in redundancy with all accessories, Battery racks, interconnecting cables etc.
EXTERNAL ELECTRICAL DSR & NSR
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, refilling the trench etc as required. protective covering and
W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing stainless steel A ISI : 304 (18/8) kitchen sink as per IS : 13983 with CI brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.
Supply & fixing of 30W LED street light Wipro LR02-331-XXX-57-XX or equivalent
Supply of decorative hot dipped galvanised mild steel step pole 6mtrs. height with grey powder finish. Compatible for street light. Window - Plasma cut & duly chamfered opening window of 300x110 mm for terminal connections & mounting accessories. Window cover is fitted with allen screws to the pole ( Excluding civil work). Havells make or equivalent
610 x 510 mm bowl depth 200 mm
15 mm C.P. brass tap with elbow operation lever
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
20 mm cement plaster of mix :
50 mm dia
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked
Metre
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
Providing and fixing C.P. brass chain and rubber plug complete for sink or wash basin: 32 mm dia
150 mm dia pipe
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. [for Basin / Urinal / Sink waste]
For 100mm diametre
For 75mm diametre
Providing and Fixing shielded coupling for Hubless centrifugally cast iron pipe.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
SS 304 grade coupling with EPDM Rubber gasket.
Providing and fixing soil, waste pipes : Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing plain bend of required degree.
Providing and fixing double equal plain junction of required degree.
100x100x100x100 mm
Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : (For RWP)
Providing and fixing double unequal plain junction of required degree :
100x100x75x75 mm
Providing and fixing single unequal plain junction of required degree :
Providing and fixing double equal plain junction of required degree.
Providing and fixing double equal plain invert branch of required degree:
Providing and fixing single equal plain junction of required degree :
Providing and fixing single equal plain invert branch of required degree :
Providing and fixingHubless centrifugally cast (spun) iron terminal guard (slotted cowl) -100 mm dia as per IS 15905
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of
cutting and making good the walls and floors :
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
100 mm inlet and 100 mm outlet
Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 12.50 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand).
32 mm nominal dia Pipes
Painting sand cast iron/centrifugally cast (spun) iron soil, waste vent pipes and fittings with paint of any colour such as chocolate, grey or buff, etc., over a coat of primer (of approved quality) for new work.
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
100mm diametre pipe
WATER SUPPLY
15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge
25 mm nominal outer dia Pipes
15 mm nominal dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gms
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Concealed Work)
40 mm nominal dia Pipes
50 mm nominal dia Pipes
65 mm nominal dia Pipes
Providing and fixing ball valves (brass) of approved quality, High or Low pressure with plastic floats complete.
15 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
20 mm nominal bore
25 mm nominal bore
(a) Internal Work- Exposed on wall
15 mm to 40 mm nominal bore
Above 40 mm nominal bore
DISMANTALING WORK FOR PLUMBING
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in Charge
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer in-Charge.
15 mm to 40 mm nominal bore
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :
Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge:
Above 150 mm dia up to 300 mm dia
Above 150 mm diameter
Above 300 mm diameter
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres
Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead.
EXTERNAL PLUMBING BOQ
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. [for Municipal and Bore Well supply to UGT/ UGR TO OHR]
65 mm diameter pipe
65 mm dia nominal bore
80 mm dia nominal bore
50 mm diameter pipe
80 mm diameter pipe
15 mm nominal bore
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coar
se sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
32 mm nominal bore
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
50 mm nominal bore
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
32 mm nominal bore
40 mm nominal bore
Cement mortar 1:4 (1 cement : 4 coarse sand)
65 mm nominal bore
Providing and fixing gun metal gate valve with C.I wheel of approved quality (screwed end).
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W pipe including bed concrete as per standard design.
150 mm Diameter S.W Pipe
200 mm Diameter S.W Pipe
300 mm Diameter S.W Pipe
1:3 (1 cement: 3 fine sand)
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
Per litre
All types of soil
100x100 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
300 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
200 mm nominal size dia
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
200 mm dia
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross Sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin- charge.
150 mm nominal size dia having minimum wall thickness 5.00 mm
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
Over Head Tank Pump
For pipes 250 to 300 mm diameter
Flow Rate-17 m3/hr (1W+1S) Head-30m
PRIMARY RO PLANT
Copper Pipe for 6.4 mm dia (OD) (Soft drawn) with tube thickness .54 mm with 19 mm thick insulation
Supply ,Testing and Commissioning of Floor Mounted R.O. Plant capable to deliver Output water at TDS < 150 PPM . The Rate Should Include Complete items inclusive of Necessary PVC Storage Tanks, Valves, Membranes, Control Panels, Pipings, Pumps, Strainers, Supports and Other accessories .Backwash once a day. Vendor to consider pre filter reqirement , if any, based on water test at their own cost. Vendor to submit design details, p&ID and plan /section drawings along with membrane calculations for approval. Vendor to submit technical datasheet including membrane details.
Copper Pipe for 12.7 mm dia (OD) (Soft drawn) with tube thickness .64 mm with 19 mm thick insulation
50 LPH WITH All Accessories and Pumps, Filters, for Fitting on Floor as per approved OEM drawings
HVAC BOQ
Air-Cooled Split Air-conditioners for cooling only of capacity given below suitable for operation on 230 ± 10 % volt, 50 Hz, 1 phase AC supply. The system shall full charge of regrigerant gas and oil. The unit shall be suitable for cordless remote operation and as per specifications. Each air-conditioner shall consist of one outdoor unit and one indoor unit and other accessories as listed below. Air-cooled condensing unit (outdoor) comprising of hermetically sealed Rotary / Scroll type compressor, condenser coil, propeller fan etc. 3 Star Inverter
Basic Price for Split AC i/c accessories, fittings, supports, Outdoor Stand, Voltage Stabilizer, ITC etc. 1.5 TR, 3 star inverter type
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping forSplit AC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
70 KLD CAPACITY MBBR TYPE SEWAGE TREATMENT PLANT
Supply, Installation, Testing & Commissioning of 1 Nos. 70 KLD Packaged Sewege Treatment plant complete with Bar Screen,all Pumps, Valves, Tanks, Pipings and accessories and necessary associated Electrical Panel and Control and Monitoring system. (The Plant shall be semi automatic with a central Control panel fully pre/site wired and with all power and control cables to all pumps and equipment including all instrumentation, level switch
Supply, installation & commissioning of 2 Nos.vertical Inline Multi Stage Centrifugal Pump for Clear Water Transfer with 50Hz, 380-415V, 2 Pole IE3 efficiency class motor (As per IEC standard). Pump shall be CI with CED quoted- Head & Base, SS 316 -Shaft and all other components will be with SS 304, Mechanical Seal (SiC vs SiC face) . Pump should have minimum 70% efficiency. (Motor Make-Siemens/ABB/Schnidler)
Supplying, installation, testing & commissioning of addressable fire controll Module complete as required.
STP Water Tertiary Treatment Plant
Metre
1 run of cable
Supplying, installation, testing and commissioning of 32 channels CCTV NVR 2 SATAPORT Network Video Recorder with all accessories such as internet connection, 2x4tb Hard Disk etc. complete in all respect to use at site.
Supplying, installation, testing and commissioning of 2MP full HD 1080p dome IP CCTV camera with all accessories complete in all respect to use at site.
Supplying, installation, testing and commissioning of 2MP full HD 1080p bullet IP CCTV camera IP-66 with all accessories complete in all respect to use at site.
Supplying, installation, testing and commissioning of 16 port rack mountable POE switch complete with all accessories .
Supplying, installation, testing & commissioning of Tertiary Plant . The Proposed WTP shall have following components in order to make the water reusable and pathogen free and safe for human and animals. Multi Grade Filter -7.5 Cum/Hr Activated Carbon Filter - 7.5 Cum/ Hr Treatiary Feed Pump of 7.5 m3/hr , 25 mts head Digital flow meter at the Final outlet
Supply, Installation, Testing & Commissioning of CAT6 patch cord factory crimp cable for connecting RJ 45 including all required like connection etc at site.
1 metre
Pump controller suitable for 2 Pumps (1W+1S) with LCD screen displays, phase loss protection (incoiming as well as for outgoing), Individual pump overload protection, individual pump under voltage protection, dryrunning protection without installing any float switch, memory function when power off and during recovery, visual and audio alarm for fault prompt, auto manual switch, and pump should operate based on the OHT water level and both pump should run together for high level. Panel should come with 2 Nos Float switch to work as per the sump water level.
Supplying, installation, testing & commissioning of cubical Feeder Pillar type double door, floor mounted, IP65, suitable for 415V, 3 Phase, 4 Wire 50 Hz AC supply system of suitable size fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing ,powder coating in approved shade, having 63 A capacity aluminium bus bars of high conductivity, Short circuit withstanding capacity of 16 KA, DMC / SMC bus bar supports, bottom base channel of MS section not less than 75 mm x 75 mm x 5 mm thick, entire panel shall have a common GI earth bar 25mm x 5mm at the rear with 2 Nos. earth stud, connections from main bus bar to switch gears with required size of copper conductor/single core cable and control wiring with 1.5 sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing and fixing of following switchgear and components complete as required.
Supplying, installation, testing and commissioning of 42 inch LED Monitor with VGA and HDMI Ports complete with all accessories .
Mandatory Inclusons in Quote Intra Unit Pipings All Valves, Stariners, Electro mechanical accessories as per SLD / Plan submitted for approval. MCC Panel common for STP & TERTIARY TREATMENT
Metre
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
speaker cable Single pair, 2-core, 1.5 sqmm
Supplying installation, testing, programming and commissioning of Audio equipment, Reference Dynamic Vocal Microphone, highest audio Performance for stage and studio.
FIRE DETECTION SYSTEM
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Grand Total STP + TERTIARY
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
10 KLD CAPACITY TYPE EFFLUENT TREATMENT PLANT
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Voice Network System.
Patch Cord Cat 6 UTP Gray 2m - Moulded SCHNEIDER/LEGRAND or equivalent make as approved by the Deptt..
Nature of Waste Water - Effluent from Labs etc Daily Effluent inflow at peak =10 M³/Day (Outlet of ETP is Discharged to STP Collection Tank) Influent Characteristic pH - 6.5 - 8.5 BOD - 500 mg/liter S. Solids - 250-450 mg/liter COD - 800-900 mg/liter Oil & Grease - 10 to 50 mg/liter Effluent discharge standard after STP Tertiary: pH - 6.5 - 7.5 BOD 5 - Less than 10 mg/liter S. Solids - Les
s than 20 mg/liter COD - Less than 50 mg/liter Oil and Grease - Traces only
Supply, Installation, Testing & Commissioning of 1 Nos. Eflluent treatment plant 10KLD having lime, alum and polyelectrolyte dozing tanks ,Bar screen,Blower . Outlet of ETP to be connected to STP inlet chamber.This is also include Raw effluent feed pump of 2 sets MCC Control panel with cables All piping & valves
Supplying including Fitting & Fixing of RJ45 Computer /Data Socket( Category 5 ( MK or equivalent Schneider/ RR /Legrand)
TV antenna socket outlet
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Voice Network System.
1 or 2 Module (75mmX75mm)
CCTV System
Public address system
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
DATA Network System.
SITC of 8 + 8 cylinder size main Oxygen manifold (header bar), complete with middle frame with chain for individual cylinder along with high pressure copper tail pipes, Non Return Valve for every cylinder. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders as per specification. Flexible tail pipes should not be used.
SITC of Fully Automatic Control Panel for Oxygen having constant flow output of over 1000 LPM or more at 55 to 60 psig Pressure as per specification
SITC of SEMI Automatic Control Panel for Emergency Oxygen Manifold having constant flow output of over 1000 LPM or more at 55 to 60 psig Pressure as per specification
Oxygen Flowmeter with Humidifier as per specification
Range: 0 to 15 LPM
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying including Fitting & Fixing of RJ45 Computer /Data Socket( Category 5 ( MK or equivalent Schneider/ RR /Legrand)
Patch Cord Cat 6 UTP Gray 1m - Moulded SCHNEIDER/ LEGRAND or equivalent
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
SITC of 1 + 1 size main Nitrous Oxide manifold (header bar), complete with middle frame with chain for individual cylinder along with high pressure copper tail pipes, Non Return Valve for every cylinder. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders as per specification. Flexible tail pipes should not be used.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
ITC of Semi Automatic Control Panel for Nitrous Oxide having constant flow output of over 450 LPM or more at 55 to 60 psig Pressure as per specification
SITC of 1 cylinder size emergency Nitrous Oxide back-up manifold (header bar), complete with middle frame with chain for individual cylinder along with high pressure copper tail pipes, Non Return Valve for every cylinder. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders as per specification. Flexible tail pipes should not be used.
Supplying installation, testing, programming and commissioning of video equipment, Mini Coax High−Resolution Cable , COAX CENTER CONDUCTOR: 28 AWG 7/36 tinned copper
MEDICAL GAS PIPELINE SYSTEM
SITC of MEDICAL VACUUM SYSTEM AS PER SPECIFICATION
Central Vacuum System Complete with Vacuum Pump, each havig 110 cfm PD with 10 Hp motor, Filter, Interconnecting Pipes, NRV, Auto Switch Gear Assembly, Exhaust Silencer and Line Filter etc.
Vacuum Tank 2000 Liters
Bacterial Filter with Drain Flask- 115 CFM FLOW RATE
Ward Vacuum Unit with Regulator, Collection Jar of 600 ml with Bracket as per specification
NITROUS OXIDE SYSTEM
Theatre Vacuum Unit mounted on Trolley consisting of Vacuum Regulator with Gauge and 2 nos. of 2000 ml Polycarbonate Jar as per specification
LP Tube
SITC of COMPRESSED AIR SYSTEM AS PER SPECIFICATION
Providing and fixing in position the following pipes cut to required lengths and necessary fittings with insulation.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
SITC of 6 + 6 cylinder size Emergency Back-up Oxygen manifold (header bar), complete with middle frame with chain for individual cylinder along with high pressure copper tail pipes, Non Return Valve for every cylinder. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders as per specification. Flexible tail pipes should not be used.
SITC of Distribution Copper Pipe as per EN 13348 - Lloyds Certified as per specification
35 mm OD x 1.2 mm thick
Compressed Air system complete with 2 nos. of Reciprocating Oil free, air cooled type, dust free, Base frame mounted Air Compressors with 10 HP Motors with Air filter 2 sets (Pre, Post and Activated Carbon)
Medical Breathing Air Dryer
Pressure Reducing Station for 4 Bar
SITC of Common Electrical Power Distribution Panel for Compressed Air System & Vacuum System as per specification complete with plant room wiring.
Air receiver shall be of 1000 litres water capacity designed considering maximim working pressure of 10 bar(g).
28 mm OD x 1.2 mm thick
22 mm OD x 0.9 mm thick
Front Loading Oxygen Outlets with probe
15 mm OD x 0.9 mm thick
Front Loading N2O Outlets with probe
Front Loading Medical Air - 4 Bar Outlets with probe
Front Loading Vacuum Outlets with probe
5 - Gas (O2,N2O, Med Air-4 Bar & Vacuum)
4 - Gas (O2,N2O, Med Air-4 Bar, sa7 & Vacuum)
SITC of Medical Gas Tubing color coded throughout their length for Oxygen, Medical Air & Vacuum
3 Gas ( O2, Air, Vacuum)
12 mm OD x 0.9 mm thick
150 mm (Wet Risers for Hydrant)
5 Gas Service ( 35 x 28 x 28 x 22 mm)
SITC of Medical Gas Outlets / Terminal Units for mounting on Wall, Bed Head Panel & Ceiling Pendant as per specification
50 mm (Drain Down Comer)
25 mm (For Internal Hose Reel Drum Conection)
150 mm (For Hydrant)
80 mm (For Internal Landing Valve)
Size : 150 mm
Size : 50 mm
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required
SITC of Medical Gas Digital Area Alarm System as per specification
63mm Single headed Hydrant Valve or Internal Landing Valve
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required
FIRE RISER SYSTEM & INTERNAL HYDRANT SYSTEM
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete. Note : The piping installation has to be put to hydraulic test to1.5 times the working pressure & as per latest applicable code & standard before applying paint etc. complete
Area Valve Service Unit with Valve & Gauge as per specification
SITC of Lockable Floor Isolation Valve with End Fittings as per specification
25mm Air release valve as per IS:14845 ISI Marked
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required
GM Branch Pipe with NOZZLE
Fire Man Axe with heavy insulated rubber handle tested to 20,000 volts as per IS:929 complete
EXTERNAL HYDRANT
Design, manufacture, supply ,installation, testing and commissioning of following Fire panel suitable for 415V, 3 phase, 4 wire, 50 hz power distribution system. The panel should be indoor, free standing, floor mounting, sheet metal clad, Cubicle, dead front, dust and vermin proof, compartmentalized design fabricated out of 14 SWG sheet steel complete with Cu busbars, a separate earth bus bar to be provided through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement, adequate size cable alley, painting, earthing numbering, damper plate etc. as required as per specifications and drawings and as per local Fire Authority requirement
Upto 1.5m depth in all classes of soil
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required
OVER GROUND
Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required
Size : 150 mm
Providing, fixing and testing forged brass 25 mm dia screwed inlet single acting air release valve with 25 mm dia Ball Valve on inlet side and pressure gauge with 15 mm isolating cock / Valve.
Excavations for pipelines in trench and pit in open areas where disposal or surplus earth is done along the alignment, including trimming and dressing sides, leveling of beds of trenches to correct grades, cutting joint holes, refilling consolidation and dewatering of refilling in 15 cm layers & restoration & unmettalled or unpaved surface to it's original condition. The rate including the cost of necessary timbering dewatering of drain water, diversion of traffic, night signals, fixing caution boars, watching fencing etc.
Orifice Plate
150 mm dia.
25 mm nominal bore Ball Valve (for Internal HRD & ARV)
Supplying, installation testing and commissioning of the following ‘C’ class MS Pipe as per IS1239 for underground/over ground pipes with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches. The work includes excavation in all types of soils and back filling, dewatering, etc., making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Architect and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes and providing and fixing pyp kote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc.
Complete as per ASTM standards/IS: 10221 for corrosion protection of pipes for the underground installation. Note: The piping installation has to be put to hydraulic test to1.5 times the working pressure & as per latest applicable codes & standard before applying paint or pipe coating or wrapping etc. complete.
oviding and fixing hydrant stand posts of 80 mm dia. With flanges and accessories and supply, fixing single headed 63 mm dia G.M. Hydrant Valve in the courtyard IS:5290 Including 2 coats of approved enamel paint (red) over a coat of primer, complete with 2.1/2” ‘Morris’ pattern instaneous couplings, etc. complete.
4 Way Fire Brigade service inlet
Providing & fixing 63mm dia RRL hose pipe as per IS 636 TYPE A TAC/ LFA approved of 15 mtr. standard length of approved pattern and size including gun metal male and female Coupling duly bound with copper wire etc. complete
Size : 50 mm
2 Way Fire Brigade draw out connection
Supplying and fixing 2 way Fire Brigade service inlet of size 150 mm dia. with 4 No. 63mm (2.1/2") size GM male outlets ( bronze male coupling) including metallic cover of mild steel and glass front, indicator plates,150mm BFV, etc. complete
Supplying and fixing 4 way Fire Brigade service inlet of size 150 mm dia. with 4 No. 63mm (2.1/2") size GM male outlets ( bronze male coupling) including metallic cover of mild steel and glass front, indicator plates,150mm BFV, etc. complete
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
FIRE PUMPS & RELATED ACCESSORIES
Supplying, installation, testing and commissioning of diesel engine driven stand-by fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.
Pump - Motor: Discharge : 180 LPM, Head : 70 mtr. (FOR JOCKEY PUMP)
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supply, laying, connection and testing bare earthing conductor for inter-connecting the earthing stations and various equipment in built up trenches, walls/ceiling, buried in ground generally as specified and shown on the drawing complete
CABLE END TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 95 sq. mm (45mm)
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required Horizontal type, multistage, centrifugal, split casing pump with bronze impeller stainless steel shaft, mechanical seal at a flow of 2280 lpm at 70 m head against all losses complete. conforming to IS 1520.Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conf
orming to IS-325.M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered with anti vibration pads.
Size : 150mm
SITC of fire brigade draw out connection with 100 mm MS suction pipe & 100 mm dia foot valve. The scope shall also include required valves, piping, M.S cabinet as required
Size : 100 mm
Supply and installation, testing and commissioning of CI Butterfly Valves ( heavy ) conforming to BS 5155 ,PN1.0 tested to 1.5 times working pressure with necessary companion flanges, bolts, nuts, gasket packing, support and any other spares, including indicator for open and shut position as per fire practice etc complete.
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
12 mm OD x 0.9 mm thick
Size : 50 mm
Size : 40 mm
Size : 25 mm
Size : 200 mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as Note: The piping installation has to be put to hydraulic test to1.5 times the working pressure (for minimum 2 hrs.) before applying paint or pipe coating and wrapping etc. Complete
SITC of Medical Gas Outlets / Terminal Units for mounting on Wall, Bed Head Panel & Ceiling Pendant as per specification
Size : 100 mm
50 mm (Drain Down Comer)
Size : 200 mm
Size : 150 mm
Non-Return Valve conforming to IS 5312 (swing type) or to API 594/598 (dual plate check type) with CI body & brass trim part, PN 1.0 having necessary companion flanges, CS hardwares. Gaskets, arrow indicating direction of flow, etc. complete. It shall be ISI Marked and approved make
9U Rack Loaded SCHNEIDER/ LEGRAND or equivalent
4K Ultra HD Smart LED TV
Supplying & fixing 63 mm dia Gun Metal Short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required
Pump - Motor : Discharge : 2850 LPM, Head : 70 mtr HYDRANT PUMPS+1 STAND BY
Pump - Motor : Discharge : 2850 LPM, Head : 70mtr (FOR STAND -BY PUMP)
Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
FIRE EXTINGUISHERS
Supplying, fixing, testing & commissioning of double flanged Sluice Valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required
Pressure Switch
6 Kg ABC (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683
ISI Marked portable fire extinguisher, 4.5kg CO2 type fire extinguishers complete in all respect including initial fill and wall suspension brackets & shall conform to IS 2878 or latest IS
Size : 40 mm
Hume Pipe : 300 NB
6Kg DCP (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
100 mm dial Pressure gauge with Syphon tubing, isolation valve & mounting accessories complete Range: 0 - 10 kg/sq.cm.
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Hose Cabinet for External yard Hydrant
FIRE MCC PANEL
Supply, installation, testing and commissioning of 25 x 6 mm GI Equipotential bar of 500 mm length with suitable. junction box to connect earthing conductor from building earthing to the equipment. (With six knock outs for connecting the equipment earthing
CABLE
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade.
Supply, installation, testing and commissioning of 25 x 6 mm GI Equipotential bar of 500 mm length with suitable. junction box to connect earthing conductor from building earthing to the equipment. (With six knock outs for connecting the equipment earthing
Supply, laying testing and commissioning of L.T. XLPE armoured / unarmoured cable confirming to IS : 7098 Part - II as per the description given below: (Note: Qty may vary +/- 15% as per actual work at site)
ISI marked (IS:15683) portable chemical fire extinguisher, Foam type capacity 9 liters with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets
Size : 25 mm
Size : 100 mm
5Kg. Clean Agent Ceiling Mounted Type Fire Extinguisher, Working Temperature -30°C to +60°C, Cylinder Testing Pressure 35 bar for 30sec., Operating Pressure 8 bar, Bulb Temp.68°C Standard, Area Coverage of 3x3 mtr., Propellant uses of Dry Nitrogen and type of Charge Clean Agent HFC-236fa (Including Internal Server & Ups Room .)
Providing and fixing TAC approved fire hose cabinet to house fire hydrant & hose, including all other related accerrories fabricated from M.S. sheet (16 Gauge) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated & painted with post office red colour of size as shown in the drawing (or as approved by Architect) to house the hydrant valve, 15 mtr.x2 nos. hose & hose reel. The hose cabinet size is 1500 x 900 mm x 450 mm
3.5 C x 95 Sq. MM. Al. XLPE ARM Cable (FIRE PANEL To Hydrant & Standby Pumps)
3.5 C x 2.5 Sq. MM. Cu. PVC Armored Cable (JOCKEY PUMP)
5 C x 2.5 Sq. MM. Cu. PVC Armored Cable
Providing and fixing Power wiring with 2
core x 1.5 sq.mm. PVC armoured copper cable for wiring pressure switches, etc. Including all required material and labour, terminations, etc. Complete.
Hose Reel Drum having 40 mtr. Hose Reel Length
Size : 200 mm
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
ApprovedMakeList.pdf
Additional Documents • 1.51 MB
BOQ_78263.xls
BOQ • 0.54 MB
DrawingKarimganjDH.pdf
Additional Documents • 26.88 MB
FinalDraftBidKarimganjDH.pdf
Tender Documents • 2.72 MB
Download all tender documents and submit your bid