Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹10.2 L+₹1,975.16 (0.19%)Rejected-Finance | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹10.2 L+₹2,718.45 (0.27%)Rejected-Finance | L3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L4₹10.2 L+₹5,281.65 (0.52%)Rejected-Finance OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L5₹10.2 L+₹6,255.15 (0.62%)Rejected-Finance | L5 | Rejected-Finance BEING L5 BIDDER |
Tender Value
₹9.2 L
EMD Value
₹18,400
Closing Date
7 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Darjeeling
P.O. Jalapahar Dist- Darjeeling (WB) Pin- 734103
REPAIR MAINTENANCE OF EXTERNAL ELETRIFICATION AND ALLIED WORKS AT LEBONG UNDER AGE I DARJEELING
2023_MES_594436_1
9050/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Darjeeling
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE (I) Darjeeling
₹18,400
Yes
13 Jun 2023
12 May 2023
9 Jun 2023
12 May 2023
7 Jun 2023
26 May 2023
Amount
Dismantiling existing ACSR (of any size or type) from over head electric line carefully without making any damage to the other existing lines and removing unserviceable conductor from the site complete all as specified and as directed by Engineer-in-charge.
Dismantling of GI earth wire and guard wire from existing OH lines complete all as specified and as directed by Engineer-in-charge.
Dismantiling of cross arms, bracings, supports etc. of MS channel or any other section complete and removing unserviceable portion from the site complete all as specified and as directed by Engineer-in-charge.
Dismantiling of insulator of any type / size / grade from over head electric line and removing unserviceable insulator from the site complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5 m in depth for foundation etc. or for laying UG cable etc not exc. 10 sqm on plan and not exc. 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed by Engineer-in-charge.
Supply & Laying of old size fly-ash bricks laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
Dismantling / Taking out old unserviceable service connection /underground cable, of any grade/type of size as below from pole / wall / cable duct / underground trench etc, complete all as specified and as directed by Engineer-in-charge.
Supply, laying, jointing and testing of LT UG cable of size 16 Sqmm 4 Core, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured, multi-stranded aluminium conductor cable, laid in trenches / ducts or fixed to poles / walls or laid under roads / paths / drains / culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection incl cable route indicator, complete all as specified and as directed by Engineer-in-charge. Note:- Excavation & earth work and pipe / sand / bricks shall be measured and paid for separately.
All as per serial item No. 11 above but cable of size 150 Sqmm 3.5 core.
All as per serial item No. 11 above but cable of size 25 Sqmm 3.5 Core.
All as per serial item No. 11 above but cable of size 10 Sqmm 2 Core.
Supply & fixing or laying galvanised steel tubing light grade (ISI marked) for protection of under-ground cable on poles/ walls alongwith fixing clamp, nuts, bolts & washers or under road crossing etc. of size 50 mm bore, complete all as per specified and as directed by Engineer-in-charge.
All as per serial item No.15 above but pipe of size 40 mm bore.
M&L for cutting existing road / hard standing not exc 20 x 30 cm in width & depth getting out excavated material for laying cable / GI tube, returning filling & well ramming watering and finish surface 10 cm from top using PCC 1:3:6 type C-1 (20mm graded stone aggregate); including removal of surplus soil, complete all as per specified and as directed by Engineer-in-charge.
M&L for outdoor type Busbar Chambers (for one incoming and two outgoing) fabricated by MS Sheet of suitable size and gauge mounting on pole suitable for 415 Volts, 3 phase, 4 wire AC supply system as specified and with and including aluminium bus bar of cap 400 amp installed on porcelain insulators. The pole box shall be dust proof, vermin proof, and made out of 14 SWG CRCA sheet and 50 x 50 x 6 mm angle iron frame work, front opening with locking arrangement incl painted with two coats of grey synthetic enamel paint over a coat of red oxide primer on the outside and two coats of red oxide primer in the inside including taking down old unserviceable busbar chamber, complete all as per specified and as directed by Engineer-in-charge.
M&L for Multistandarded Copper Conductor cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to Street Light Fitting, Post Top Lantern & etc including taking down old unserviceable cable, complete all as per specified and as directed by Engineer-in-charge.
M&L for earthing complete including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth strip 32 x 6 mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 40 mm dia. light grade pipe and watering pipe shall be 20 mm ore medium grade PCC pipt with pre cast RCC cover, charcoal/salt funnel etc. including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge. NOTE : (i)The concrete pit shall be PCC 1:3:6 tye C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @10 cm C/C on both sides with suitable cast iron handle shall be provided in liew of cast iron cover shown in electrical plate No. 3 of MES SSR Part-1 (ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) Item includes the cost of 7.5 mtr length earth strip.
M&L for preparation of old painted steel surfaces removing of rust from any kind of steel surface, clamps etc for of any description and repainting with one coat of synthetic enamel paint over a coat of red oxide primer, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing old plastered surfaces and applying two coats of cement base paint on walls including complete removal of existing treatment complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C-1 (20mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as per specified and as directed by Engineer-in-charge.
Disconnecting from OH conductor/ conductor on panel/ FPB, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining after dressing and re-alignment incl saddles etc to restore electric supply all as specified and as directed. Note :- (i) Cable protection Pipe if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of lugs/ sockets and cutting and removing the pole coping and inserting the cable alongwith protection pipes. (iii) coping shall be measured and paid separately.
M&L for stay assembly comprising of MS stay plate 6 mm thick and of size 300 x 300 mm and 20 mm dia MS stay rod, 2150 mm long including thimbles GI stay strand 7/3.15 mm dia of required length complete all as shown on electrical plate No.1 on page No.495 of MES SSR Part-I 2009 including necessary excavation PCC 1:3:6 Type C2 (using 40mm graded stone aggregate), loop insulator as specified in SSR and including taking down old unserviceable one complete all as per specified and as directed by Engineer-in-charge.
M&L for loop type insulator, vitreous porcelain, white, brown or green, large size with overall dimensions 90 x 140mm size, clearance of hole 25.5 mm complete all as per specified and as directed by Engineer-in-charge.
M&L for cross arms i.e bracing supporting clamps back plates, nuts, bolts and washers complete including one under coat and one finishing coat with synthetic enamel paint over a coat of red oxide primer complete all as per specified and as directed by Engineer-in-charge.
M&L for ACSR jumpers in LT over head line upto 10 mm dia as that of existing size including binding wire, nuts & bolts washers including taking down old unserviceable one complete all as per specified and as directed by Engineer-in-charge.
M&L for danger notice plate of 1.6mm thick, and of size 20 x 15 cm made of mild steel sheet, vitreous enameled white, with letters, figures and convention skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size including taking down old unserviceable one, complete all as per specified and as directed by Engineer-in-charge.
M&L for Cradles, hexagonal/rectangular fabricated with galvanised steel 4mm dia. including taking down old unserviceable one complete all as per specified and as directed by Engineer-in-charge.
M&L for ACSR conductor, steel reinforced for LT over head lines on poles including streching tightining of poles insulator with binding wire of suitable size with insulator / streching of ACSR conductor, complete all as per specified and as directed by Engineer-in-charge.
M&L for maintenance of earthings of installations like cleaning of earth pits, treatment of earthing by pauring salt water, replacement of perished wire mesh, unserviceable funnel and repair works like patch works with cement mortar 1: 4, complete all as per specified and as directed by Engineer-in-charge.
M&L for restreching/restringing, tightening and repair to overhead line ACSR conductor of any size on LT poles including necessary Aluminium binding wire connectors PVC sleeves for jumper, fixing of insulators and prunning of tree, complete all as per specified and as directed by Engineer-in-charge.
M&L for shingle filling in floors or pavings of Gauge 40 to 63 mm, deposited, spread and levelled in layers not exc. 150mm thick, watered and rammed to a true surface, complete all as per specified and as directed by Engineer-in-charge.
Supply, lay, commissioning and testing of cable jointing Kit Heat shrinkable type for 1100 V grade cable for straight through joint with jointing material and accessories suitable for LT UG cable of size 16 to 50 Sqmm, 3.5 Core, complete all as per specified and as directed by Engineer-in-charge.
All as per serial item No. 35 above but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core, complete all as per specified and as directed by Engineer-in-charge.
All as per serial item No. 35 above but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 150 Sqmm, 3.5 Core, complete all as per specified and as directed by Engineer-in-charge.
All as per serial item No. 35 above but suitable for aluminium conductor cable of size from 185 sqmm, 3.5 Core to 240 Sqmm, 3.5 Core, complete all as per specified and as directed by Engineer-in-charge.
Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for outdoor End termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 to 50 Sqmm, complete all as per specified and as directed by Engineer-in-charge.
All as per serial item No. 39 above but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core.
All as per serial item No. 39 above but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 150 Sqmm, 3.5 Core.
All as per serial item No. 39 above but suitable for aluminium conductor cable of size from 185 sqmm, 3.5 Core to 240 Sqmm, 3.5 Core. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S TSHERING BHUTIA
BIMAL BHATTRAI
Damdoo Bhutia
HIRA SINGH
SANJAY KAUSHIK
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .