Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹2.7 LAccepted-Finance | ₹2.7 L | L 1 | Accepted-Finance OK |
| 2 | L 2₹4.3 L+₹1.6 L (61.1%)Accepted-Finance | ₹4.3 L+₹1.6 L (61.1%) | L 2 | Accepted-Finance OK |
Tender Value
₹3.0 L
EMD Value
₹5,920
Closing Date
13 Aug 2026, 6:00 pmClosed
EE 19th Dn. IGNP, Jaisalmer
EE 19th Dn. IGNP, Jaisalmer
O and M of making water arrangement system for canal colony and Dabla pumping station
2026_IGNP_582005_4
NIT No. 02/2026-27
Open Tender
Civil Works
Percentage
365 days
Jaisalmer
Please refer Tender documents.
2 documents required · 2 mandatory
₹200
EE 19th Dn. IGNP, Jaisalmer
₹5,920
Yes
20 Aug 2026
4 Aug 2026
14 Aug 2026
4 Aug 2026
13 Aug 2026
4 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repair Rewinding of Submersible motor includes full servicing and rewinding (wherever required) as per manufacturers specification and to the satisfaction of Engineer Incharge. It includes the replacement of minor parts such as bushes (oil seal bush) Nut Bolts, washers, cable seal, gland ring, vent plug, water drain plug, etc. complete job 3.1.8 Above 17.5 HP to 20 HP 3.1.08.02 V-8 PHED BSR 2021 MAINTENANCE ITEM NO. 3.1 | - | each | - | - |
| 2 | SCHEDULE OF SPARES and REPAIR OF SUBMERSIBLE PUMP : Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.8 Providing and fixing Microlone Guide per piece 3.3.8.1 V-6 | - | each | - | - |
| 3 | Rewinding of three phase squirrel cage induction motor of HSC pump sets including all necessary material and of the same characteristics as original with required size of super enameled copper wire (including cost of copper wire), E class insulation material and testing of motor on no load but to be guaranteed against testing on load at site, including transportation of motor pump to and from Div/AEn/JEn store complete as per direction of engineer in charge. 3.9.3 Above 20.00 HP but up to 25.00 HP | - | each | - | - |
| 4 | Repairing of leakage in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T and P and labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost) 1.1.1 In all type Soil AC/PVC/HDPE pipe 1.1.1.5 150/160/180mm. PHED 2021 ITEM NO. 1.1.1.5 | - | each | - | - |
| 5 | Unlowering of submersible pump set along with lowering pipes with depth up to 120 mtr and submersible cable with safety from tube well, checking the pump set, transportation of pump set from tube well site to store as direction, receiving repaired / new pump set from store/ divisional store , testing the same, transportation to site and lowering back into tube well along with submersible cable, lowering pipes, specials etc and commissioning of the tube well. The job also includes cable jointing, checking of discharge of pump set, interconnection of lowering pipe from nearby distribution pipe line, checking of starter and reporting for completion of Job or fault/problem if any. (Upto 20 Km distance run by lowering machine) 2.1.1 For three Phase pump set 2.1.1.1 G.I. Double Flanged Pipe Lowering Assembly of nominal dia 2.1.1.1.3 80 mmPHED BSR 2021 MAINTENANCE ITEM NO. 2.2.1 | - | each | - | - |
| 6 | 1.4.1.31.4 Replacement of CI/ DI Double flange sluice valves,non return valves,butter fly valves etc. in existing Distribution/Rising Main/Transmission Main pipe line up to 1.5 mtr depth of sizes as
given below by digging out suitable size of pit at site of work including providing and fixing MS Nut and Bolt and rubber gasket, dewatering and providing adequate safety arrangement at site and
then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and
will arrange transportation of required material from store.(Required material such as Valve, Tail piece, CID Joints etc. shall be provided by Department free of cost) 1.4.1 In all type Soil
1.4.1.3 125 mm | - | each | - | - |
| 7 | Bolts and nuts above 300 mm in length. PWD BSR 2022 ITEM NO. 1035 | - | Quintal | - | - |
| 8 | Providing & Fixing of ISO certified company made TP&N 415 V side handle operated double break fuse switch unit in sheet steel enclosure as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 (W/O HBC fuses) including making connections with suitable lugs, testing etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .100A Rating. pwd bsr 2022 item no. 10.1.2 | - | each | - | - |
| 9 | Providing & Fixing of ISO certified company made TP&N 415 V side handle operated double break fuse switch unit in sheet steel enclosure as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 (W/O HBC fuses) including making connections with suitable lugs, testing etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 200 A rating . PWD ELE BSR 2022 ITEM NO. 10.1.3 | - | each | - | - |
| 10 | Supply and fixing of 100 Amp, 11kV Horn gap fuse set IS 9385 on existing DP structure with 6 nos 24kV/22kV post insulator (IS:5350 part III), hot dipped hard ware,fuse wire of required size etc. complete in all respect as per Discom specification etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. pwd bsr 2022 ele item no. 19.17 | - | each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
4.pdf
Tender Documents • 1.04 MB
BOQ_1034100.xls
BOQ • 0.34 MB
IMG_0001.pdf
PDF • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .