Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | ₹32.3 L Quoted ₹32.8 L | L1 | Accepted-AOC L1 Bid found in order |
| 2 | L2₹33.0 LRejected-AOC | ₹33.0 L | L2 | Rejected-AOC Other than L1 bid |
| 3 | L3₹39.5 LRejected-AOC | ₹39.5 L | L3 | Rejected-AOC Other than L1 bid |
| 4 | L4₹41.0 LRejected-AOC | ₹41.0 L | L4 | Rejected-AOC Other than L1 bid |
| 5 | Rejected-Technical | - | - | Rejected-Technical Adverse remarks in WLR QE Jun 2025 as per CE 31 Zone |
| Sl No | Description | Qty | Unit | M/s Manmeet Builders L1 | M/S MANZOORAHMAD LONE L4 | m/s mohd saleem and co L2 | M/S GHULAM AHMAD BABA L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling wall and ceiling boarding (Fibre, pulp, insulation, etc) any description, fixed in any position with nails including cover fillets complete all as specified and directed. | 110 | Sqm | 10 ₹1,100 | 25 ₹2,750 | 10 ₹1,100 | 30 ₹3,300 |
| 2.00 | Demolition of brick/stone masonry work built in cement mortar of any description complete all as specified and directed. | 12.07 | Cum | 200 ₹2,414 | 300 ₹3,621 | 10 ₹120.70 | 375 ₹4,526.25 |
| 3.00 | Dismantling floor, hearth or wall tiles including cement mortar bedding complete all as specified and directed. | 170 | Sqm | 50 ₹8,500 | 30 ₹5,100 | 10 ₹1,700 | 28 ₹4,760 |
| 4.00 | Taking down of shutter exc 1 sq. m and n exc 2 sq. m each complete all as specified and directed. | 11 | Each | 100 ₹1,100 | 140 ₹1,540 | 10 ₹110 | 88 ₹968 |
| 5.00 | Taking down chowkats with shutters (without taking off shutters from the frame) n exc. 1.50 sqm each & removing from site complete all as specified and directed. | 5 | Each | 100 ₹500 | 140 ₹700 | 10 ₹50 | 80 ₹400 |
| 6.00 | Refixing of door/window in same opening of shutter n exc 1 sq. m each complete all as specified and directed | 5 | Each | 200 ₹1,000 | 140 ₹700 | 100 ₹500 | 80 ₹400 |
| 7.00 | S&F 35mm thick second class soft wood Glazed and skeleton door shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. | 12.5 | Sqm | 2,000 ₹25,000 | 2,400 ₹30,000 | 2,500 ₹31,250 | 2,500 ₹31,250 |
| 8.00 | S&F 35mm thick second class soft wood Plain, framed, panelled shutters for door (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed. | 8 | Sqm | 2,100 ₹16,800 | 2,400 ₹19,200 | 3,500 ₹28,000 | 2,500 ₹20,000 |
| 9.00 | M&L for Aluminium sliding three track window with powder coated aluminium (minimum thickness of powder coating 50 micron) frame of aluminium section 62.5mm x 37mm x 1.5mm thick with two glass shutters and one mosquito proofing shutters with but 0.56 mm nominal dia of wire and average width of aperture1.18mm having style and rails of aluminium section 47.62mm x 44.45mm x 1.5mm thick including joining cleats, glazing clips, rubber packing, aluminium snap beading, screws anodized aluminium fittings such as hinges, tower bolts, handle etc., including 4.5 mm thick sheet glass, wire netting fixed in repairs, complete all as specified and directed. | 7 | Sqm | 6,500 ₹45,500 | 14,500 ₹1.0 L | 10,000 ₹70,000 | 12,500 ₹87,500 |
| 10.00 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. | 15 | Sqm | 600 ₹9,000 | 550 ₹8,250 | 600 ₹9,000 | 550 ₹8,250 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹75,600
Closing Date
25 Dec 2025, 6:00 pmClosed
GE 874 EWS
GE 874 EWS Kupwara
SPL REP TO BLDG NO P-85, PROVN OF TOWER POST AND REPLACEMENT OF OH LINE TO UNDERGROUND CABLE UNDER THE AOR OF GE 874 EWS.
2025_MES_741145_1
GE 874/EWS-70/2025-26
Open Tender
Civil Works
210 days
KUPWARA
As per NIT
6 documents required · 6 mandatory
₹500
Yes
GE 874 EWS
₹75,600
Yes
11 Feb 2026
22 Nov 2025
27 Dec 2025
22 Nov 2025
25 Dec 2025
8 Dec 2025
Amount
Dismantling wall and ceiling boarding (Fibre, pulp, insulation, etc) any description, fixed in any position with nails including cover fillets complete all as specified and directed.
Demolition of brick/stone masonry work built in cement mortar of any description complete all as specified and directed.
Dismantling floor, hearth or wall tiles including cement mortar bedding complete all as specified and directed.
Taking down of shutter exc 1 sq. m and n exc 2 sq. m each complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutters from the frame) n exc. 1.50 sqm each & removing from site complete all as specified and directed.
Refixing of door/window in same opening of shutter n exc 1 sq. m each complete all as specified and directed
S&F 35mm thick second class soft wood Glazed and skeleton door shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F 35mm thick second class soft wood Plain, framed, panelled shutters for door (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
M&L for Aluminium sliding three track window with powder coated aluminium (minimum thickness of powder coating 50 micron) frame of aluminium section 62.5mm x 37mm x 1.5mm thick with two glass shutters and one mosquito proofing shutters with but 0.56 mm nominal dia of wire and average width of aperture1.18mm having style and rails of aluminium section 47.62mm x 44.45mm x 1.5mm thick including joining cleats, glazing clips, rubber packing, aluminium snap beading, screws anodized aluminium fittings such as hinges, tower bolts, handle etc., including 4.5 mm thick sheet glass, wire netting fixed in repairs, complete all as specified and directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F 2nd class soft wood wall panelling 10 to 12 mm thick of good quality wood planed one side and edges tonged and grooved or rebated other side and dovetailed joints, chamfered both sides fixed to frame with secret nails as in wall panelling including cornice and beading as required and applying two coat of varnish over a fillet coat of thin varnish after preparation of surface complete all as specified and directed.
S&F 6 mm thick Plywood, grade BWR, type BB, fixed with nails to timber frame work as in ceiling complete all as specified and directed.
S&F 6 mm thick Plywood, grade BWR, type BB, fixed with nails to timber frame work as in wall complete all as specified and directed.
S&F in repair Grating doom 100mm dia of PTMT (minimum weight 25gms) suitable for floor taps, complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete as specified and directed.
M&L for 25 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) in sub base of floor complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 complete all as specified and directed.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4, on external wall finished even and fair mixer with integral water proofing compound @ 3% by weight of cement or in the manner specified by the manufacture and in the proportion indicated complete all as specified and directed. Note:- WPC shall be measured and paid separately.
M & L for 15 mm thick rendering on stone masonry surfaces or surfaces other than fair faces of brick work in CM 1:6, rendering finishes even and smooth (without using extra cement) complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
S & F 3 mm thick plain sheet glass ordinary quality and glazing with oil putty or wooden beads in square area not exc. 0.5 Sqm in each pane including hacking out old broken glass of any thickness size from wooden or steel frames complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 20 cm x 20cm size and 25 mm thick Chequered cement concrete tiles (in any colour & shape/pattern), set, jointed and pointed in neat cement slurry in floors with grey cement & no pigment over and including 20 mm screed bed in CM 1:6 complete all as specified & directed.
S&F 20mm thick 2nd class softwood boarding, planed one side, with butt joints and fixed with nails in facia eaves boarding including dismantling complete all as complete all as specified and directed.
M&L for ceramic tiles 10mm thick light shade area of each tiles not exceeding 0.36 sqm as in flooring, set & jointed in neat cement slurry and pointed in white or coloured cement to match alongwith 15mm thick screed bed in CM 1:4 etc complete all as specified and directed.
M&L Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match colour tile over and including rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and directed.
M&L Non skid ceramic coloured tiles 7-8 mm thick, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, of each tile in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile on 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
Dismantling Stone slabs and tiles laid beaded and pointed in cement mortar of any description or thickness in floors, aprons etc. complete all as specified and directed.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 in floor complete all as specified and directed.
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed including 10mm thick rendering in cement mortar 1:4 backing coat for fixing complete all as specified and directed
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 15 mm screed bed or bedding layer in CM 1:4 complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling complete all as specified and directed.
M & L for fixing Second class soft-wood, clean sawn scantlings unframed timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section including dismantling of old unservicable scantling complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over one coat of pink primer by preparing of new wooden surfaces of any description, not otherwise described over 10cm width or girth complete all as specified and directed.
M&L for Preparation of old painted surfaces and applying two coat of synthetic enamel paint on wooden surfaces of any description not other wise described over 10 cm width or grith etc complete all as specified and directed.
M&L for IInd class soft wood Plain fillets exc 3 & n exc 6 sqcm square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
M&L for preparation of old plastered wall surfaces and applying two coats of cement based paint complete all as specified and directed.
M&L Preparing newly plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M&L for preparation of old plastered/unplastered surface of wall and applying one coats of Distemper oil emulsion complete all as specified and directed.
M&L for complete removal of existing treatment from surfaces of wall and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
S&F extruded aluminum alloy with galvanised mild steel hinge pin Butt hinges 100mm long type B-21 complete all as specified and directed.
S&F Aluminum anodised, barrel tower bolts of extruded section and fixed 150 mm long complete all as specified and directed.
S&F extruded aluminium alloy handles 150 mm, fabricated type, anodised complete all as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) 250mm long not less than 12mm dia with and including minimum of 06 bolts and nuts, 4 on plate and 2 on staple and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, plate and fixed complete all as specified and directed.
M&L for galvanised steel tubes medium grade 15 mm dia bore fixed to wall or ceiling or laid under floor, complete with necessary fittings including taking up or down old unserviceable tubes any type complete all as specified and directed.
M&L for galvanised steel tubes medium grade 20 mm dia bore fixed to wall or ceiling or laid under floor, complete with necessary fittings including taking up or down old unserviceable tubes any type complete all as specified and directed.
M&L for cement concrete 75 mm thick, type C-2, 1:3:6 (20mm graded aggregate) as in plinth protection/path sub base of floor complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
M&L for mild steel work as in roof trussed (framed) purlins crane gantries rail & fastening and heavy bracket (beam tea angle channel or flat section) including distance pieces cleats of grade FE 410W (e 250) Quality-A etc complete all as specified and directed.
S&F in repair Vitreous China Wash hand basin, white, flat back of size 550x400mm including brackets, waste coupling PTMT (half or full thread) for 32mm bore dia of discharge pipe, and waste pipe PVC 32mm dia including cutting for and pinning in ends of brackets or erecting stand etc, complete all as specified and directed.
S&F in repair for CP Pillar taps, with capstan head chromium plated 15 mm bore fancy type complete all as specified and directed.
S&F in repair Bib tap cast copper alloy chromium plated fancy type with crutch of butterfly handle, screwed down, screwed for iron pipe of for brass ferrule of 15mm bore (ISI marked) complete all as specified and directed.
S&F in Repairs 15mm dia chromium plated fancy type angular Stop valves/angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F in repair soap dish of CP brass 100 X 150mm size complete all as specified and directed
S&F vitreous China bowl urinal flat back, size of 465x355x265mm white (minimum), with urinal spreader, with grating and union for discharge pipe (including waste pipe) complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store complete all as specified and directed.
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
M&L for concrete bed to drain pipes 100-110mm dia pipe including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C2 including excavation, returning filling and ramming complete all as specified and directed
S& F in repairs 1000 Ltr capacity Rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S & F in repair gun-metal, globe or gate valves of 15mm dia bore, with iron wheel head, screwed both ends for iron pipe and fixed etc complete all as specified and directed.
S&F ball valve 20mm bore high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed, (minimum weight 210 gms) complete all as specified and directed.
Demolition of Concrete (Reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for pre-cast cement concrete type B1 (1:2:4) (20mm graded aggregate) for landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including form work complete all as specified and directed
M&L for Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
S & F stainless steel drapery or curtain rods, 25 mm dia, with end brackets, decorative type, cut to length as required size, colour coating including matching socket and brackets, complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc in soft/loose soil complete all as specified and directed.
M&L plain Cement concrete as in foundation, filling & mass concrete type D-2 1:2:4 (using 40 mm graded aggregate) complete all as specified and directed.
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.in soft/Loose soil complete all as specified and directed.
M&L for removing excavated material/soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed
All as per item No 69 above but for additional 1.50m or there part of in depth beyond the first 1.50 mtr. complete all as specified and directed
M & for PCC 1:4:8 type D-2 (40 mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M & L for RCC M-30 design mix (20 mm Graded aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
M & L for RCC M-30 design mix (20 mm Graded aggregate) in Columns, pillars, piers, posts and struts concrete complete all as specified and directed.
M & L for RCC M-30 design mix (20 mm Graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M & L for RCC M-30 design mix (20 mm Graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M & L for TMT mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M & L rendering 5 mm thick in CM 1:3 on fair faces of brick work or concrete surfaces as in roof slab etc complete all as specified and directed.
M & L for non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws of minium size 605 x 605 mm as in ceiling complete all as specified and directed
M & L for Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to entre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed
M L for preparing new plaster surfaces and non asbestos fibre cement building boards of ceiling and applying three coat of white wash complete all as specified and directed
M L for Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed
M&L for cement concrete type D-2, 1:4:8 (40mm graded aggregate) 75 mm thick as in sub base for floor finishes complete all as specified and directed.
M&L for cement concrete 40 mm thick, type B-1, 1:2:4 (20mm graded aggregate) as in floor finishes and even and smooth without using extra cement complete all as specified and directed.
M&L Hard drawn steel wire fabric dia 3.8 mm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement complete all as specified and directed.
M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, of Fe-410-W (Gde E-250) quality A without any attachment complete all as specified and directed.
M&L for mild steel work as in Stairs (framed) including stringers, treads, landing, balusters, hand rails etc. including cleats, brackets, etc. of Fe-410-W (Gde E-250) quality A complete all as specified and directed.
M&L applying two coats of synthetic enamel paint on new steel surfaces of any description over 10cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed.
M&L applying two coats of synthetic enamel paint on new steel surfaces of any description not exc 10cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed.
S & F mild steel work as in bands, straps, hold fasts and similar small articles conforming to Fe 290 Gde complete all as specified and directed.
S&F MS press handles 100 mm size cast type, anodised complete all as specified and directed.
M & L for 25mm thick 2nd class softwood boarding, planed one side, with butt joint fixed with nails in Fascia, eaves boarding complete all as specified and directed.
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F 1.00 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings, removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specified and directed.
Taking down DB's including MCB's etc complete all as specified and directed.
Taking down carefully unserviceable sub main wiring of any size/core/type including making good the disturbed surfaces complete all as specified and directed.
M & L for point wiring with PVC insulated unsheathed single core multistranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLSH, drawn through PVC casing caping/ PVC Conduit of suitable size (as per site requirement) including accessories and provision of PVC boxes for mounting switches, switch socket, fan regulator, modular metal flush boxes (metal switch board of any type and size) with modular metal frame plate and white cover for housing switch required on site or as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) earth wire and connected to earth dolly One light /one fan/one bell point controlled by one switch complete all as specified and directed.
All as per item No 106 here in before but for one socket outlet 5 pins 5 amps controlled by one switch on same board .
All as per item No 106 here in before but for one socket outlet 5 pins 5 amps controlled by one switch on independent board.
All as per item No 106 here in before but wiring with 2.5 sqmm copper wire (FRLS) and 2.5 sqmm earth wire for socket outlet 6 pin 15 amps on independent board.
S&F Modular switch 1 way 6A, 1 module complete all as specified and directed.
S&F Modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.
S&F Modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and directed.
S&F Modular bell push 6 A, 1 Module, complete all as specified and directed.
S & F Buzzer, Ding Dong Bell AC,230 Volts, Single pole complete all as specified and directed.
S&F lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed.
Supply and fix LED Bulb 9 Watt complete all as specified and directed.
S&F 20W surface / wall mounted batten LED luminaire, extruded aluminium housing with PC diffuser and independent electronic driver with high efficiency long life, CRI = 80 (Minimum), PF > 0.95, luminous efficacy > 100 lumens/Watt operating voltage 140V-240V, CCT (K) > 6500, THD < 10% complete including 20W LED tube rod with all accessories internally prewired and including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting prewired and including making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceiling rose/PVC connector to light fittings complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
S & F LED light fitting 1x9W/10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F LED light fitting 10W Focus light including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
M & L for providing/cutting the round/ square hole of required size in wall finishing the disturbed surfaces as per existing finishes and supply and fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writing MES No. with black synthetic enamel paint 2.0 cm high complete all as specified and directed.
M & L for providing/ cutting the round/ square hole of required size in wall finishing the disturbed surfaces as per existing finishes and supply and fixing exhaust fan made of x exhaust fan, steel body AC single Phase. 230V of size 450m sweep with, blades, and frame and louvers and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writing MES No. with black synthetic enamel paint 2.0 cm high complete all as specified and directed.
Supply and fix water heater storage type, electric capacity 25 ltr along with all accessories BEE 5 star rated, complete all as specified and directed.
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F building security light fitting in repair LED 35 Watt for Energy saving and environmental friendly long life made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07 including driver unit and bracket made up of GI tube of suitable size (1.2 Mtr Length) etc complete all as specified and directed.
M & L for sub main wiring with two single core 6 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor FRLS ISI marked drawn into & including medium grade PVC conduit/ casing caping 25 mm dia with all fittings and accessories and one continuous run of 6 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC casing / conduit (not less than 25mm outer dia) with all fittings and accessories fixed concealed/ surface including taking down old unserviceable submain wiring and making good disturbed surface complete all as specified and directed.
M & L for sub main wiring with two single core 4 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor (FRLSH) ISI marked drawn into & including medium grade PVC conduit/ casing caping 25 mm dia with all fittings and accessories and one continuous run of 2.5 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC casing / conduit (not less than 25mm outer dia) with all fittings and accessories fixed concealed/ surface including taking down old unserviceable submain wiring and making good disturbed surface complete all as specified and directed.
S&F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 8 way including blanking plate as required with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed.
S&F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 4 way including blanking plate as required with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed.
MCB single pole & neutral 40 to 63 Amps 230 Volts 'C' series, 10 KA complete all as specified and directed.
S&F MCB's single pole 240 volts 6 to 32Amps 10 KA 'C' series, complete all as specified and directed.
S & F in repair distribution boards VTPN, 8 way, double door 415 volts 50 Hz ,AC incl fixing on suitable rectangular block complete all as specified and directed.
S & F in repair MCCB ,100 Amp, 4 Pole breaking capacity 16KA, 415 Volt, 50 Hz with sheet metal enclosure complete all as specified and directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable of size 16 Sqmm complete all as specified and directed
M&L earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, complete all as specified and directed.
S&F switch piano flush button single pole, one way 5 amps complete all as specified and directed.
M & L for Switch socket combination 2 in 1, 3 pin, 6 Amps flush type complete all as specified and directed.
Supply and fix Axis cabin wall mounting fan of size 400mm sweep complete and connecting up including provision of with copper standard conductors cables from ceiling rose/connector to fan complete all as specified and directed.
M & L for ceiling rose, PVC/Polycarbonate three terminals complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED bulb 5W suitable for fixing in PVC angle holder complete all as specified and directed.
Taking up the unserviceable XLPE LT UG cable 3.5/ 4 core 16 Sqmm to 95 Sqmm from trenches or walls complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core
Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified.
Material and labour for burnt Sub class 'B' bricks laid dry, flat, width wise along the length of cable in trenches after sand cushioning for protection of under ground cable complete all as specified and directed.
Supply and lay in trenches, fixed to wall/pole UG Cable XLPE insulated screened PVC beaded galvanised steel strip or wire armed heavy duty electric cable with multi stranded Aluminium conductor, 1100V grade of size 16 sqmm 4 core complete all as specified and directed.
Dismantling of ACSR conductor of any Size and capacity complete all as specified and directed.
Dismantling of LT steel poles/struts, of 9 mtr size complete all as specified and directed
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m complete all specified and directed.
Dismantling insulators any type, any size complete all as specified and directed
Dismantling stay assembly complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed
Supply and fixing copper thimble of size 10 sqmm to 120 sqmm complete all as specified and directed.
M & L for GI Tubing light grade 80mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole complete all as specified and directed.
M & L for GI Tubing light grade 40 mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole complete all as specified and directed.
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars of Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 2.00 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size including the provision of space to accommodate the under mentioned items. The scope of work includes the following:-
(a) Incoming
(i) MCCB 4 pole, 415 volts AC grade, 400 Amps rating and 38 KA rupturing capacity Adjustable Thermal & Fixed Magnetic - 01 Nos
(ii)Aluminium bus bar of size 25x5mm and capacity 400 Amp-04 Nos
(v) LED Indicating lamps : 01 set of three
(vi) Secure 3 Phase, 1 Element, 4 Wire 440 V Digital Power Factor Meter - 01 Nos
(vii) Current & Potential Transformer : 01 Nos
(b) Outgoing
(i) MCCB 4 pole, 415 volts AC grade,160 Amps rating and 26 KA rupturing capacity Adjustable Thermal & Fixed Magnetic - 04 Nos
(c) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone,15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level.
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars of Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 2.00 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provision of 65mm Godrej (Freedom) lock with 2 keys, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size including the provision of space to accommodate the under mentioned items. The scope of work includes the following:-
(a) Incoming
(i) MCCB 4 pole, 415 volts AC grade, 160 Amps rating and 38 KA rupturing capacity Adjustable Thermal & Fixed Magnetic - 01 Nos
(ii)Aluminium bus bar of size 20x3mm and capacity 220 Amp-04 Nos
(v) LED Indicating lamps: 01 set of three
(vi) Secure 3 Phase, 1 Element, 4 Wire 440 V Digital Power Factor Meter - 01 Nos
(vii) Current & Potential Transformer: 01 Nos
(b) Outgoing
(i) MCCB 4 pole, 415 volts AC grade,80 Amps rating and 26 KA rupturing capacity Adjustable Thermal & Fixed Magnetic - 04 Nos
(c) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level.
Supply installation, connect, testing and commissioning of 3 phase 4 wire 50 Hz 440 volts out door type bus bar enclosure 0.9 x 0.9 x 0.4mtr size compartmentalised cubical type with canopy, dust and vermin proof free standing floor mounting type mounted on and including 1:3:6 PCC platform with required mounting channel feeder pillar box fabricated out of 3.15 mm thick CRCA steel sheet duly pre-treated and powder coated factory fabricated including cable glands of suitable sizes and consisting of the following ;-
(a) Aluminium bas bar 100 amps - 04 Nos,
(b) Incoming TPN MCB 4 Pole 40 to 100 Amp -01 Nos,
(c) Outgoing MCB SPN 40 to 63 Amp - 04 Nos and supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.
Supply installation, connect, testing and commissioning of 3 phase 4 wire 50 Hz 440 volts out door type bus bar enclosure 0.9 x 0.9 x 0.4mtr size compartmentalised cubical type with canopy, dust and vermin proof free standing floor mounting type mounted on and including 1:3:6 PCC platform with required mounting channel feeder pillar box fabricated out of 3.15 mm thick CRCA steel sheet duly pre-treated and powder coated factory fabricated including cable glands of suitable sizes and consisting of the following ;-
(a) Aluminium bas bar 63 amps - 04 Nos,
(b) Incoming TPN MCB 4 Pole 40 to 100 Amp -01 Nos,
(c) Outgoing MCB SPN 32 Amp - 04 Nos and supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized earth strip of size 32x6mm by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, all as specified and directed.
m/s mohd saleem and co (BID ID -3503242)
M/S GHULAM AHMAD BABA (BID ID -3507331)
M/S MANZOORAHMAD LONE (BID ID -3508005)
Bidder Name
M/s Manmeet Builders
M/S MANZOORAHMAD LONE
M/S GHULAM AHMAD BABA
m/s mohd saleem and co
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
BOQ_829897.xls
BOQ • 0.33 MB
70TENDER.pdf
Tender Documents • 1.89 MB
Download all tender documents and submit your bid