Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC HOSHIARPUR CANAL CIRCLE PUNJAB | ₹1.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.0 Cr+₹22.4 L (12.3%)Rejected-AOC | ₹2.0 Cr+₹22.4 L (12.3%) | L2 | Rejected-AOC L2 |
| 3 | L3₹2.1 Cr+₹25.5 L (14.0%)Rejected-AOC 282 NASIRABHAD GANDHI CHOWK AJMER RAJASTHAN 305601 | AJMER | RAJASTHAN | 305601 | ₹2.1 Cr+₹25.5 L (14.0%) | L3 | Rejected-AOC L3 |
| 4 | L4₹2.1 Cr+₹27.1 L (14.9%)Rejected-AOC 35 MODEL TOWN G T ROAD JANDIALA GURU DISTRICT AMRITSAR | JANDIALA GURU | AMRITSAR | PUNJAB | ₹2.1 Cr+₹27.1 L (14.9%) | L4 | Rejected-AOC L4 |
| 5 | L5₹2.4 Cr+₹56.2 L (30.9%)Rejected-AOC | ₹2.4 Cr+₹56.2 L (30.9%) | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | subhash and sons L3 | EMM ENGINEERS L5 | NEO ENERGY SOLUTIONS L2 | Manoj Electricals L1 | Star construction company L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Solar Panel 500KW Top-Con Bifacial Inverter at Pojewal Lift Scheme at RD 112526m of Kandi Canal Stage-2 in District SBS Nagar . Design,Supplying,Installation of Project including Following works . Structure Hot Dipped Galvanised Moudule Mounting Structure (Ground/Roof Mounted) 2mm thickness ,Cable DC-4mmAC-3.5C-150mm Aluminum Armoured,ACDB Box of Approved Make-Main AC Distribution Box complete with 1 Nos ClassI +II Surge Protective Device, with CT & Multifunction Meter. DCDB of Approved make with fuses & DC SPD 2 in2 out. Lighting Arrestor of Approved make Lighting Arrestor Conventional 150 Mtrs , RAdius with Mounting Structure for Lighting Arrestor.Earthing of approved Make Chemical Gel based. Nut Bolts Hot Dipped and Related Civil WorkG (Inclusive of taxes,GST,duties and Transportation) including Testing and commissioning of the system after the completion of the work to the entire satisfaction of Engineer-in-charge and this work include operation and maintenance of the Work for 5 years . | 1 | each | 2,07,37,252 ₹2,07,37,252 | 2,38,09,518 ₹2,38,09,518 | 2,04,26,985 ₹2,04,26,985 | 1,81,86,955 ₹1,81,86,955 Lowest | 2,09,00,000 ₹2,09,00,000 |
Tender Value
₹2.9 Cr
EMD Value
₹5.9 L
Closing Date
1 Dec 2025, 10:00 amClosed
Xen,Kandi Canal Stage2 Division,hoshiarpur
Xen,Kandi Canal Stage2 Division,hoshiarpur
Estimate for Installation of On Grid Solar System on Pojewal Lift Scheme at RD 112526m of Kandi Canal Stage-2
2025_WR_153369_1
12/2025-26
Open Tender
Electrical Works
Item Rate
60 days
Hoshiarpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
₹5.9 L
Yes
Xen,Kandi Canal Stage2 Division,hoshiarpur
15 Jan 2026
10 Nov 2025
1 Dec 2025
10 Nov 2025
1 Dec 2025
10 Nov 2025
26 Nov 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Solar Panel 500KW Top-Con Bifacial Inverter at Pojewal Lift Scheme at RD 112526m of Kandi Canal Stage-2 in District SBS Nagar . Design,Supplying,Installation of Project including Following works . Structure Hot Dipped Galvanised Moudule Mounting Structure (Ground/Roof Mounted) 2mm thickness ,Cable DC-4mmAC-3.5C-150mm Aluminum Armoured,ACDB Box of Approved Make-Main AC Distribution Box complete with 1 Nos ClassI +II Surge Protective Device, with CT & Multifunction Meter. DCDB of Approved make with fuses & DC SPD 2 in2 out. Lighting Arrestor of Approved make Lighting Arrestor Conventional 150 Mtrs , RAdius with Mounting Structure for Lighting Arrestor.Earthing of approved Make Chemical Gel based. Nut Bolts Hot Dipped and Related Civil WorkG (Inclusive of taxes,GST,duties and Transportation) including Testing and commissioning of the system after the completion of the work to the entire satisfaction of Engineer-in-charge and this work include operation and maintenance of the Work for 5 years . | - | each | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.64 MB
BOQ_310963.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .