Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC PO KETEKIBARI DISTT SONITPUR TEZPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | ₹3.6 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹3.7 Cr+₹15.4 L (4.34%)Rejected-Finance | ₹3.7 Cr+₹15.4 L (4.34%) | L2 | Rejected-Finance Not Validated, other than lowest |
| 3 | L3₹3.7 Cr+₹16.8 L (4.71%)Rejected-Finance OLD HASIMARA DISTT JALPAIGURI WEST BENGAL PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | ₹3.7 Cr+₹16.8 L (4.71%) | L3 | Rejected-Finance Not Validated, other than lowest |
| 4 | L4₹3.8 Cr+₹28.0 L (7.87%)Rejected-Finance BINDA JAYANTI BUILDING 31 SEVOKE ROAD SILIGURI PIN 734001 DIST DARJEELING | SILIGURI | DARJEELING | WEST BENGAL | 734001 | ₹3.8 Cr+₹28.0 L (7.87%) | L4 | Rejected-Finance Validated, Lowest Bidder |
| 5 | L5₹3.8 Cr+₹28.0 L (7.88%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | ₹3.8 Cr+₹28.0 L (7.88%) | L5 | Rejected-Finance Not Validated, other than lowest |
Tender Value
₹3.9 Cr
EMD Value
₹4.6 L
Closing Date
15 Oct 2020, 6:00 pmClosed
HQ CE Siliguri Zone
HQ CE Siliguri Zone, Sevoke Road, PO-Salugara, Siliguri, Pin-734008
ADDITION/ALTERATION AND SPECIAL REPAIRS TO CERTAIN MARRIED ACCN AT SOUTH ZONE AND MES AREA, BINNAGURI UNDER GE(SOUTH) BINNAGURI
2020_MES_351838_1
98715/BIN(S)/SZ/E8
Open Tender
Civil Works
Item Rate
608 days
Binnaguri
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
GE(S) Binnaguri
₹4.6 L
Yes
11 Dec 2020
11 Jun 2020
16 Oct 2020
11 Jun 2020
15 Oct 2020
5 Oct 2020
11 Jun 2020 - 22 Jun 2020
Amount
B/R WORKS(Sch 'A' PART-I)
Roughening surfaces of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust and brushing neat cement slurry with 3.0 kg of cement per Sqm complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specially provided for as in Floors,surface channel etc complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and as directed.
M&L for 15mm thick screed bed or bedding layer in CM (1:6) as in floor complete all as specified.
M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11Sqm but n. exc. 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in whiter or coloured cement to match as in floor and skirting complete all as specified and as directed.
M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floor etc set and jointed in 2 mm thick (minimum thickness) polymer modified cementous tile adhesive point in polymer modified cementus tile grout whiter or coloured cement to match as in floor cand skirting complete all as specified and as directed.
S&F of coloured joint free Non skid ceramic tiles 8 to 9mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, in floor , skirting,riser and landing etc set and jointed in neat cement slurry over 15mm thick screed bed for laying floor finishes in CM (1:6) complete all as specified and as directed
M&L for joint free non skid coloured ceramic tiles 8 to 9mm thick (Square/rectangular) area of each tile exceeding 0.18Sqm but n. exc. 0.36 Sqm, in floors and skirting etc. set and jointed in 2mm thick (minimum thickness) polymer modified cementous tile adhesivepoint in polymer modifed cementus tile grout whiter or coloured cement to match as in floor complete all as specified and directed.
M&L for double nosing and steping stone 15mm thick of colour as approved (Jhonson or equivalent) as in Treads of stiarcase set and jointed in neat cement slurry over and including 15mm thick screed bed in CM (1:4) complete all as specified and directed.
M&L for Vitrified tiles 8 to 10mm thick (Square/rectangular) as in risers of staircase set and jointed in neat cement slurry over and including 10mm thick screed bed for laying floor finishes in Cement mortar (1:4) complete all as specified and as directed.
M&L for 10mm thick rendering in CM (1:4) as in vertical surfaces of skirting dados repairs to steps complete all as specified and directed.
M & L for glazed ceramic colour tiles 450X300X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile approved by Engr-in-Charge complete all as specified and directed.
M & L for glazed ceramic colour tiles 300X200X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile approved complete all as specified and directed.
M & L for 18-20 thick Zed Black Granite ,single piece minium 2 metre length as in cooking platform, shelves etc over 10 mm thick cement screed bed in CM (1:4) , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including Grinding, polishing to gratinite finish to the edges of projected portion of granite slab of cooking platform, shelves etc. chamfered to half round complete all as specified and directed.
Providing holes to cooking platform of 25mm dia for inserting cooking gas pipe in suitable place as directed by Engineer- in -Charge one no.each kitchen.
Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exceeding 5km and not exceeding 6Km in location as directed by GE including roughening of old concrete suirface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed.
M&L 50 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in sunken floor /in floorings including levelling the surface with proper slope towards spout pipe finishing the surface even and smooth using extra cement including WPC @ 3% all as directed.
M&L for cutting out cracks to 'V' section (shape) in existing roof slab terracing cleaning out and filling solidely with cement and sand mortar (1:1) complete all as specified and as directed.
M&L for 10mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for applying single component acrylic polymer modified, finished even and smooth without using extra cement complete all as specified and as directed. (NOTE : Polymeric membrane shall be measured and paid separately under relevant item of this Schedule 'A').
M & L PCC (1:2:4) type B1 (20mm graded aggregate) as in roof kerbs, slightly rounded or chamfered on edges, mixed with water proofing compound in top layer @ 3% by weight of cement or as per manufacturer instructions finished even and smooth on exposed concrete surface without using extra cement all complete as specified and as directed. (Note: Water proofing compound shall be measured and paid perarately under relevant item of schedule 'A').
M & L water proofing treatment to RCC roof slab including parapet comprising of the following course of treatement / specified from bottom to top :- (a) Applying Bituminous primer @ 0.40 Ltr per Sqm over plastered surfaces of roof including parpet surfaces. Over the priming coat laying one layer APP based polymeric membrance of approved manufacturer, 3 mm thick of weight not less than 3.60 Kgs/Sqm reinforced with non woven polyester fabric weight not less than 160 gms per Sqm. Edges of APP membren shall be inserted to vertical surfaces of wall as per relevant IS or as per manufacturer's instruction Polymeric members shall be taken to a height of 60cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrance flashing. (b) Application of two coat of bituminous aluminium paint over the polymeric membrane after necessary preparation and cleaning. NOTE :- (i) Laying APP based polymeric membrance shall be done by torch on method or as per manufacturers instructions. (ii) A minimum overlap of 100mm shall be made at the end and 75mm shall be made at the sides of the polymeric membrance respectively and sealed all ovelaps and joints as per Manufacturers instructions.
Dismantling water tanks and removing to store of capacity exceeding 500 & not exceeding 1000 ltrs complete all as specified and as directed.
S & F of 500 ltrs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) including connecting up pipes securing access covers etc as specified and as directed.
Disconnecting existing tanks of capacity exceeding 250 Ltrs and not exceeding 500 Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in same position after cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed.
Plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) in water tank platforms,filling and mass concrete complete all as specified and as directed..
S&F of 20 mm dia PVC ball cock (PVC float valves) complete high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut complete all as specified and as directed.
Taking up or down GI 15mm bore pipe and connection including cleaning for refixing or removal from site as directed.
Taking up or down GI 20mm steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed.
S&F of 15mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors fixed to wall etc complete all as specified and as directed.
Refixing old 15mm GI tubing and connections on new or old position (walls, ceilling, floor etc) complete all as specified and as directed.
S&F of 20mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors fixed to wall etc complete all as specified and as directed.
Refixing old 20mm GI tubing and connections on new or old position (walls, ceilling, floor etc) complete all as specified and as directed.
Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed.
M&L for 20mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm & 10mm) mixed with water proofing compound in top layer @ 3% by the weight of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed.
M&L for plastering 10mm thick in cement mortar 1:4 mixed with WPC as in chajjas complete all as specified and as directed. NOTE : WPC shall be measured separately.
Supply only integral water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:6) on other than fair face of brick work or concrete surface finished even & smooth (without using extra cement) complete all as specified and directed.
M&L for prepartion of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying 2mm thick cement based wall putty to wall surface complete all as specified and directed.
M&L for prepartion of old plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying 2 mm thick cement based wall care putty including complete removal of existing treatment all as specified and directed.
M&L for rendering 5mm thick plastering in CM (1:3) on ceiling, soffits of slabs, chajjas, columns and beams etc and finished the plastered surface even and smooth without using extra cement complete all as specified and as directed.
M&L preparing newly plastered or unplastered surface of ceiling and applying three coats of white washing complete all as specified and directed.
M&L for preparartion of old surfaces applying two coat of white washing on ceiling surface complete all as specified and directed.
Demolition of brick work built in cement mortar of any description complete all as specified and as directed.
M & L for brick work with sub class ‘B’ old size bricks, straight or curved on plan and any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed.
M&L for brickwork with sub class B bricks straight or curved on plan exceeding 6mtr mean radius built in cement mortar (1:6) by using old size bricks complete all as specified and as directed.
S&F of sinks with drainage board made of stainless steel 1mm thick sheet plugs, washers and waste pipe, including a pair of cantilever brackets embedded in wall with suitable size of PCC (1:3:6) type C-1 blocks and connecting union to pipe of overall size 915mm x 460mm & bowl size 410mm x 330mm x 160mm all complete as specified and as directed.
S&F in repairs vitreous china wash basin, white, flat back, size 550x400m excluding taps, waste, chain & plug & porcelain stopper including brackets incl cutting for pinning in ends of bracketes or erecting stand and fixing and supply and waste pipe complete all as specified and directed.
S&F in repair 10 ltr capacity PVC flushing cistern low level white colour including PVC connection PVC flush pipe of required length complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580x440mm white with integral foot rest complete including provision of lime concrete bedding complete all as specified and as directed.
S&F in repair vitreous china wash down water closet pan (pedestral pattern), white including connection trap and to flushing pipe, anti-syphnoge pipe etc complete all as specified and as directed.
S&F in repair PVC seat cover for pedestal pan, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminiumised hanging device complete all as specified and as directed.
S&F in repairs Bib taps fancy type cast copper alloy, chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule all complete as specified and as dierected. MAKE : ESSCO/Marc/Jaquar.
S&F in repairs stop valves fancy type cast copper alloy, chromium plated with long shank and cup (concealed type) for 15mm bore pipe, screwed both ends including necessary fittings such as sockets for pipe or for union all complete as specified and as directed. MAKE : ESSCO/Marc/Jaquar..
S&F 20mm bore Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all complete as specified and as directed.
S & F in repair 15mm bore PVC Connection with PTMT nut of length 600 mm complete all as specified and directed.
S&F of pillar taps, fency type ,cast copper alloy with capston heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe 15mm bore complete all as specified and as directed. MAKE : ESSCO/Marc/Jaquar.
S&F in repair 15 mm bore angle cock CP with flage complete all as specified and directed.
S&F in repair CP health faucet with one meter tube and hook complete all as specified and directed.
S&F for stainless steel tubular towel rail, 20mm dia, 60cm long between flanges, including fixing bracket complete all as specified and as directed.
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chomium plated bracket guard and railing 60 cm long complete all as specified and as directed.
S & F Soap dish, stainless steel of approximate size 125mm complete all as specified and as directed.
S&F in repair 0.63 mm thick stainless steel plate rack of size 31"x30"x10" complete all as specified and directed. MAKE : Model No BSKPR-314 of Blue Star/Nirali or its equivalent make.
S&F in repair swivel shower of CP with shower arm 150 mm size for fixing with 15 mm bore GI pipe complete all as specified and as directed.
S&F PVC corner shelf three tier without shutter best quality as approved by GE fixed with stainless steel screws complete all as specified and as directed.
S & F in repair Grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40gms) complete all as specified and as directed.
S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
Taking down PVC soil pipe with fittings from wall, treches of any description including fittings complete all as specified and as directed.
S&F of 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F of 110mm dia PVC bends of any radius acess door complete all as specified and as directed.
S&F 110mm dia PVC (SWR) branch piece single (single 'Y'/T) equal or unequal with acess door complete all as specified and as directed.
S&F 110mm dia PVC SWR vent cowl complete all as specified and as directed.
S&F of 75 mm bore PVC (SWR) rain water pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F of 75 mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
S&F of 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as specified and as directed.
S&F of 75 mm bore PVC (SWR) Vent Cowl complete all as specified and as directed.
M/L for 75mm PVC floor trap with grating including jointing to waste pipe fixed in cement concrete B1 (1:2:4) complete all as specified and as directed.
S&F of 75 mm bore PVC (SWR) branch piece single (Single 'Y') equal or unequal with access door complete all as specified and as directed.
Taking down chowkat with shutter exceeding 1.5 sqm and not exceeding 4.00 sqm each complete all as specified and as directed.
Taking down shutter of any description but exceeding 1 sqm and not exceeding 2 sqm each complete all as specified and as directed.
Refixing shutter of any description but exceeding 1 sqm and not exceeding 2 sqm each in same opeining etc complete all as specified and directed.
S&F for pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc., size of frame 125 x60 mm complete all as specified and as directed.
S&F for pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc., size of frame 105 x60 mm complete all as specified and as directed.
M & L for providing plain cement concrete type C-1, (1:3:6), (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. complete all as specified and as directed.
S&F factory made 35mm flush shutter, solid coare construction, with block board core and plywood face panel, commercial type on both side etc complete all as specified and directed.
All as per Serial Item No. 1.85 here-in-above but partly glazed i.e. upper panel will be wire mesh fitted externally in the clear space & lower panel will be plain colour PVC sheet 5mm thick complete all as specified and as directed.
M&L for preparation of newly small article such as rafter feet, bracket or cantilevers not exceeding 30 cm projection and blocks, lebels,etc. not exceeding 0.1 sqm each and applying two coats of sythetic enamel paint over a paint of pink primer etc complete all as specified and as directed.
S& F of 2nd class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours, articles not exceeding 200 cu. cm each complete all as specified and as directed.
S&F of 100 mm but hinges stainless steel complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section 200 mm long all as specified and as directed.
S&F aluminium handles 150mm size cast type anodised complete all as specified and as directed.
M&L for sliding door bolt of 300mm long plate Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
M&L for preparation of new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
M&L for preparation of old wooden surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed.
Solid PVC door frame of size 50x47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, supplied and fixed including fixing of hold fast as per specification and drawing complete all as specified and as directed.
S& F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification with Wood free EPS complete all as specified and as directed.
S&F 150 mm long Aluminium anodised barrel tower bolts complete all as specified and as directed.
S&F aluminium handles 125 mm size cast type anodised complete all as specified and as directed.
S&F in repair stain less steel curtain rod 25mm dia thickness not less than 0.75mm ,fixed with curtain rod holder and finials (to be paid seperately) complete all as specified and as directed.
S&F stain less steel curtain rod holding braket heavy duty fixed to wall with stainless steel screws complete all as specified and as directed.
S&F in repair stain less steel finial type stop end suitable for curtain rod 25mm dia as approved by GE complete all as specified and as directed.
M & L for providing & fixing factory made solid PVC cup board frame of size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5 mm thick PVC sheet of density 600Kg/cbm having pattam width of 50mm and thickness of 10mm. All three frame length reinforced with 19mm x 19mm MS square tube of 19 gauge. mitre cut at two corners and joined with two nos of 150mm long brackets of 15X15mm MS square tube or joint by fusion hit welding. The door frame shall be fixed to the wall thickness using 8Xthroughout the frame and metre cut at two corners and jointed with 2 nos of 150mm long brackets of 15mm x 15mm MS square tubes.The door frame shall be fixed to the wall using 8/100mm long MS screws through the frame by using PVC fasteners. A minimum 4 nos of screws to be provided for each vertical member and minimum 2 nos of screws to be provided to the horizontal mmember etc.complete all as specified and dir by Engineer in charge.
M&L for providing & fixing factory made solid PVC cup board shutter (Flush type) of 24 mm thick made from co-extruded 3 layer regid PVC foam sheet (single extruded) with density not less than 600kg/cbm outer layer (.8-1mm) thick should be of rigid PVC with density of not less than 1400kg/cbm manufactured byan ISO 9001-2015 certfied company. Door should be water proof, turmite proof, fire retardant and having good screw holding capacity all as specified and as directed..
M&L for providing and fixing factory made PVC shelf/partitation of required size consisting of 20mm thick solid PVC sandwich with 1mm thick lamination sheet on both sides suitably fixed with stainless steel heavy duly angle cleat and s/s screws , complete all as specified and directed by Engineer-in-charge.
Taking down chowkat with shutter not exceeding 1.5 sqm each (without taking off shutter from the Frame) complete all as specified and as directed.
S&F in repair stainless steel wire cloth 0.36 nominal dia wire & average width of aperature 1.40 mm fixed with stainless steel wire staples complete all as specified and as directed.
S & F in repairs 2nd Class Hard wood Plain fillets of sectional area not exceeding 3 Sq.CM square or Rectangular in section wrought chamfered or rounded on one edge or face complete all as specified and directed.
S&F Powder coated aluminium window sliding type three track (2 glazed & one gauze shutter) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing , screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surface of wall complete all as specified and as directed.
S&F Powder coated aluminium louvered ventilators of size 600X600mm with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazing cleats, rubber packing , anodised aluminium snap beading,screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangements including taking down of old existing steel ventilator and making good disturbed surface of wall complete all as specified and as directed.
S&F of anodised aluminium powder coated aluminium grill size 65 x 65 mm DECO GRILL (DG-104) with dia of bar not less than 6 mm fixed to flat aluminium windows with F or C channel (for window and ventilator) complete all as specified and as directed
M & L for 75mm Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed.
S&F 75mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick (Below or above ground level) complete all as specified and directed.
M&L 75mm thick PCC (1:3:6) type C2 as in plinth protection/footpath using 40mm graded stone aggregate finishing cement concrete surface even & smooth without using extra cement including impression and glass strip or bitumen filling in two panel etc complete all as specified and as directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed.
Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings including ridges, hips, valleys and flashings complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S & F Rolled Mild Steel sections confirming to Fe 410 - W (Gde - E - 250) Quality - A as in rafters,verticals,purlins where connected to common rafters fixed with angle cleats or other connecting plates complete all as specified and as directed.
S&F of Mild steel work in wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shapes as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embedding in concrete and screwing etc, and similar work confirming to Fe 290 Gde E-165 complete all as specified and as directed.
S & F Mild steel screw bolts of 11 to 15 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 22.5 cm and not exceeding 30 cm long complete all as specified and as directed.
Cutting Holes in brick walls built in cement mortar superficial area not exceeding 150 sqcm complete all as specified and as directed.
Cutting Holes into or through cement concrete slabs, chajjas etc reinforced or otherwise superficial area not exceeding 100 sqcm complete all as specified and as directed.
Demolition of Reinforced cement concrete of roofs,floors(other than ground floors), beams, staircase, landings, chajjas and similar suspended work complete all as specified and as directed.
S&F in repair .63 mm thick plain aluminium sheet bent to shape fixed with pins to door shutter to prevant water splashing complete all as specified and as directed.
M & for water proofing treatment to sunken floor with the following course of treatment/ specification: (i) Cleaning top surface of floors /slabs and laying 50 mm thick (avg) PCC of grade M10 (Nominal mix) , mixed with WPC as per manufactrrer's instruction laid in slope 1:20 towards spouts including coveting corners (ii) 15 mm thick plastering in CM (1:4) on sides mixed with WPC as pe rmanufacturer's instruction. (iii) Applying 1st layer of slurry @ 0.488 kg / sqm mixed wth acrylic based polymer modified cementious compound @ 0.253 kg /sqm This layer shall be allowed to air cured for 4 hrs .st layer of slurry of cement at the rate of 0.488 kg/sqm mixed with acrylic based polimer, modified cementitous composite compound at the rate 0.253 kg/sqm. This layer will be allowed to air cure for 04 hours. (iv) applying 2nd layer of slurry @ 0.242 kg/sqm mixed with accrylic based polymer modified cementenous compound @ 0.126 kg/sqm.This layer shall be allowed to air cured for 4hrs followed with water curing for 48 hrs.(v) Applying a coat of industrial bitumen 85/25 penetration @ 1.50 kg/sqm on plastered and concrete surfaces (vi) Providing 150 micron thick polyutethene paint in two coats (each of 75 micron measured dry on dry surface over a coat of PU primer including preparation. (Make of PU primer - Dek guard EP -302 of M/S Fosroc or equivalant approved brand.Make of PU paint - Dek guard PUor equivalant approved brand. (vii) 2 Nos 32mm bore GI medium grade 450mm long spout ,to be provided through external wall to drainout accumulated water.(viii) Sunken floor shall be tested for water tighness by filling water for 72 hrs before and after treatment work is carried out and ensure that no leakage /seepage exists (ix) Sunken portion shall be filled with lean concrete of grade M7.5 stone agreegate
M&l for PCC 1:4:8 (type D2) using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for applying two coats of black bituminus paints on new surfaces of any description wood, steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth Surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and as directed.
M&L for RCC (1:1.5:3) type A1 using 20mm graged stone agreegate as in chajjas and like complete all as specified and as directed.
M&L for RCC (1:1.5:3) type A1 using 20mm graged stone agreegate as in slabs supported on wall, beams and colums in floors, roofs, landings, balconies etc complete all as specified and as directed.
M&L Form work to chajjas and like finished fair complete all as specified and as directed.
All as per Serial Item No. 2.31 here-in-above but as in soffits of suspended slabs such as roof slab, floor slab landings and similar work not exceeding 200 mm thick complete all as specified and as directed.
M&L for TMT bar 10mm dia and over cut to length,bent to shape required, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for TMT bar 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Use and waste of formwork to sides and soffits of, shelves, platform etc rough finished surfeces of concret flat etc complete all as specified and as directed.
Use and waste of formwork edge of concrte flats,treads breaks in floors,window cill,concrete railing openings in concrete walls floor and roofs not exceeding 20 cm wide and sids of Rcc/Pcc bands in walls horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide complete all as specified and as directed.
M&L for salt-glazed stoneware gully traps, square or round mouthed, type `P' 150x100mm complete all as specified and as directed.
Forming construction joint 10mm wide 30m deep filled with bituminous mastric or sealing compound as in plinth protection complete all as specified and as directed.
M&L 100 mm thick Cement concrete type C2, (1:3:6) (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing complete all as specified and as directed.
M&L Plain Cement Concrete Type B0 (1:2:4) (using 12.5 mm graded stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work.complete all as specified and as directed.
Precast cement concrete (1:2:4), type B1 (using 20 mm graded stone aggregate) in landings, bed plates, pintle blocks, anchorage blocks, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar (1:4) complete all as specified and as directed.
Removing building materials and debris (other than excavated earth) to a distance of exceeding 4.5 Km but not exceeding 5 KM inside MD Land at locations specified including loading and dumping/ leveling at the destination complete all as specified and as directed.
S&F of brass cromium plated wall mixer for mixing hot and cold water, half turn type ,screwed down for iron pipe and fixed complete all as specified and as directed.
S&F of stainless steel butt hinges fixed with stainless steel screws complete all as specified and as directed.
S&F of stainless steel door handle 125 mm size fixed with S/S screws complete all as specified and as directed.
S&F of magnetic catch for cupboard shutter complete all as specified and as directed.
M & L for preparing new Plastered surfaces of walls, Chajja/Fasia etc surfaces and applying two coats of weather proof Acrylic Exterior emulsion paint of approved make and shade over a coat of Acrylic emulsion primer all as specified and directed as per manufactrers instructions and as directed. Make of Weather proof exterior acrylic emulsion and primer : Asian Apex Ultima/Berger weather coat Allguard or equivalent make as approved.
M & L for complete removal of existing treated surfaces of walls including cornices, pillasters and other wall feathers etc by washing rubbing down and stopping and applying two coats of weather proof Acrylic Exterior emulsion paint of approved make and shade over a coat of Acrylic emulsion primer all as specified and directed as per manufactrers instructions and as directed. Make of Weather proof exterior acrylic emulsion and primer : Asian Apex Ultima/Berger weather coat Allguard or equivalent make as approved.
Sub total
E/M WORKS (Sch 'A' PART-II)
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sundn terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be sone through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for the following :- Item Continued as 3.03 to 3.08
(a) One light point controlled by one way switch 5/6 amps.
(b) One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps.
(c) One socket out let 5/6 amps point on the same board
(d) One socket out let 5/6 amps point on the independent board
(e) One bell/buzzer point controlled by one bell push button
(f) One light point controlled by two two way switch 5/6 amps.
M&L for point wiring complete for one socket outlet 15 Amps point on independent board with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles.
M&L for point wiring complete for one power point for one metal plug & socket for AC or one socket for geyser point on independent board with 4.0 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 4.0 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles.
S&F socket 2 in 1, 5 Pin, 5/6 amps, 230 Volts AC (ISI Marked) white ivory finish flash type complete all as specified and directed.
S&F socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush type 5/6 amps single pole one way all as specified. Make : Anchor Penta/ Havell's Reo
S&F bell/buzzer push 5/6 amps flush type white/ivory finish complete all as specified and directed.
S&F switch piano type 2 way 5/6 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge.
S&F switch piano flush type 15/16 amps single pole one way complete all as specified and directed.
S&F call bell ding dong type AC Single pole 220/240 Volts, surface type complete all as specified and directed.
S&F ceiling rose, PVC/ polycarbonate, isolated body, three terminals, complete all as specified and directed.
M & L lamp holder, insulated PVC/ Polycarbonate body, with back plate suitable for batten/angle fittings complete all as specified and directed.
S & F deluxe fan Electronic regulator AC 50 Hz, 100 watt, rotary step type, white/ivory finish complete all as specified and directed.
S&F, IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S & F Bulk head luminaire suitable for 10 Watt LED (or nearest next higher wattage) light IP66 grade, luminaire efficiency not less than 120 lumens/watts with and including 10 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S&F IP 20, Class I, LED Mirror light fitting 1 x 10 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified.
S&F of Decorative wall light fixture made up of Polycarbonate suitable for 10 Watt (or nearest next higher wattage) LED light having B-22 base lamp holder with and including 10 watt LED lamp and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified and as directed.
M&L for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, including taking down old unsv aluminium submain wiring all as specified and as directed. NOTE : Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
S&F of Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door, Tripple pole & neutral with 200 amps rated bus bar, IP-20 protection, including four pole MCCB with blanking plates complete all as specified and directed.
S&F of MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8way, single pole and neutral, with 100 Amps rated copper bus bar (as per OEM), neutral link, ertth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and as directed.
S&F of MCB Single pole and neutral 40 amps, 240 volts, ‘C’ curve, 10KA all complete as specified and as directed.
S&F of MCB Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed.
S&F of heavy duty exhaust fan 300 mm sweep MS body with antidust painting, 4 blade with heavy duty motor and double ball bearing, 1320 RPM, single phase 230/240 volts copper wounds, Air delivery -1600 CMH complete with all accessories as bird guard/ louvers shutters etc incl making connections with 3 core flexible multistranded copper conductor of size 0.75 Sqmm run through flexible pipe all as specified and as directed including cutting holes and making good the disturbed surfaces of walls in CM(1:4) and finishing the surface as per existing color scheme.
Taking down Ceiling Fan 1200 mm sweep, sealing cable end,dismantling blades and removing fan and blades to store to keep it in safe custody and refixing/hanging only the ceiling fan and connecting up after B/R plaster work all as directed by Engr- in-charge.
M&L for earthing with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means of bolts & nuts,check nuts & washers made of galvanised steel, earth strip protected by and including PCC (1:2:4) type B1 precast RCC cover slab (M-15) reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI wire protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 2009 and testing on completion complete including dismantling the existing unserviceable earthing complete all as specified and as directed.
Supply, installation, testing and commissioning of electric water heater, storage vertical type, BEE 5 star rated, 25 ltr capacity 230 volts AC, 50 Hz comprising of high wattage heating element for instant heating, extra thick SS inner tank of superior 304 grade, rust & shock proof ABS outer body, non-ferrous pressure plate with & including provision of Pressure relief valve and grouting bolts suitably flushed to wall or any other surface including electric connection with 3 core PVC insulated, sheathed, stranded copper conductor cable/flexible chord complete all as specified and as directed.
M&L for GI water tubing medium grade 15 mm dia fixed on wall with all fittings and fixtures complete all as specified and as directed.
S&F of angle stop valve with wall flange, chromium plated, screwed down (CP) of size 15 mm fancy type complete all as specified and as directed.
M&L of 15mm bore bib taps, cast copper alloy chromimum plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F of Hot and cold water connection 450mm long for Geyser, including connection pipe complete with all necessary items complete all as specified and as directed.
Taking down unservicable DB/Main Switches/Elect Meter of any type and any capacity incl taking out MCBs(SP/SPN) complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty ISI marked) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core laid in trenches/ drawn into pipes/fixed to walls complete incl taking out old cable/service wire complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and n.exc 1.5m in depth for laying of cables etc and getting out in any type of soil complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated materialnot exceeding 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed.
M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed. NOTE : Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I.
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
Supply and fixing 40 mm dia GI tubing light grade ISI marked laid in trenches / laid under floor for protection of cable including all fittings such as elbow, bends, etc and short length complete all as specified and directed.
Sub total
S.N. GHOSH AND CO.
DEEP NIRMAN
HARBHAJDAS AGARWAL
M/S R. K. INDUSTRIES
M/S JYOTI SHARMA AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .