Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-Finance | L1 | Accepted-Finance Valid documents received and accepted. | |
| 2 | L2₹31.7 L+₹1.8 L (6.07%)Accepted-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L2 | Accepted-Finance Valid documents received and accepted. | |
| 3 | L3₹31.7 L+₹1.9 L (6.35%)Accepted-Finance 59 ST MARY S ROAD SECUNDERABAD 500 003 | SECUNDERABAD | SECUNDERABAD | TELANGANA | 500003 | L3 | Accepted-Finance Valid documents received and accepted. | |
| 4 | L4₹32.9 L+₹3.1 L (10.4%)Accepted-Finance 728 1 JOGIWARA VISHAVKARMA MANDIR ROAD AMBALA CITY | AMBALA CITY | AMBALA | HARYANA | 134003 | L4 | Accepted-Finance Valid documents received and accepted. | |
| 5 | L5₹36.8 L+₹6.9 L (23.2%)Accepted-Finance | L5 | Accepted-Finance Valid documents received and accepted. |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
6 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Sagar Maheshwari, IDSE
GE (AFA) Hyderabad, Dundigal, Hyderabad
PROVISION OF CERTAIN MINOR WORKS OF B/R AND E/M AT AFA HYDERABAD
2024_MES_636133_3
8423/E8
Open Tender
Civil Works
Works
180 days
GE (AFA) Hyderabad
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE (AFA) Hyderabad
₹68,000
10 Jun 2024
18 Apr 2024
7 May 2024
18 Apr 2024
6 May 2024
22 Apr 2024
18 Apr 2024 - 22 Apr 2024
Amount
S&F Earthing grid indicator made out of 3 mm thick MS sheet of size 300x200 and different shapes (oval,rectangular,triangle,square with semi circle on top of it) duly welded with 500 mm long 25x25x6mm angle iron duly fixed near to the grid point with cement grout and painting of plates as directed by Engr-in-charge including writing earthing details such as earth resistance,connected to etc complete all as specified and as directed.
Supply and install Rotational moulded polythene water storage tanks of 1000 ltr capacity as per IS 12701-1996 includes securing cover,connecting up pipes (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
Supply and fix 20mm GI pipe with screwd joints, tube fillings such as bends,elbows,tees,short pieces,connectors,back-nuts,diminishing pieces,caps,plugs and unions,etc and fixing complete with clips,wall hooks,wooden plugs,or laying in trenches etc,also for cutting,screwing and waste for making forged bends on piping as required.connectors shall be inserted,where required or directed. The rates also include cutting through walls,floors,etc and their making good.
Supply and fix 25mm GI pipe with screwd joints, tube fillings such as bends,elbows,tees,short pieces,connectors,back-nuts,diminishing pieces,caps,plugs and unions,etc and fixing complete with clips,wall hooks,wooden plugs,or laying in trenches etc,also for cutting,screwing and waste for making forged bends on piping as required.connectors shall be inserted,where required or directed. The rates also include cutting through walls,floors,etc and their making good.
S &F Bib tap standard of PTMT any colour high pressure screwd for iron pipe and fixed.(minimum weight 15mm-90gms/20mm-125gms)
M&L for PCC 1:2:4, type B1 (20 mm graded stone aggregate) as in copings, bed plates, valley gutters, kerbs etc including necessary form work complete all as specified and as directed.
M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth without using extra cement complete all as specified.
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M deep and getting out in hard / dense soil/road for laying/removing of cable/pipe.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in hard/dense soil /road all as specified and directed.
Removing excavated material/surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point.
M& for test point terminal block made of gun meosphorous bronze simm drilled and screwed including3 no.s 8mm dia long hex.head screw
M & L dry river Sand covering /cushioning for underground cable protection complete all as specified and directed by Engr- in Charge.
M&L for burnt bricks sub class 'B' laid perpendicular over & cushioning for cable protectioncomplete all as specified & directed at site by the Engr- in Charge.
M & L for Point wiring with 1.5 Sqmm multistranded copper conductor wire with unsheathed, FRLS grade PVC insulated, single core with earth continuity conductor of 1.5 sqmm FRLS grade PVC insulated multistranded copper conductor and including rigid PVC conduit of suitable size but not less than 20mm dia. and all accessories fixed to the surface of the roof/ walls or in chases etc. including terminal boxes made out of MS sheet of thickness should be not lessthan 1.2mm thick for fixing of switches, fan regulators socket outlet etc along-with 3mm thick top laminated bakelite sheet for housing switches, etc complete all as specified and as directed for the following :-
(a) One light point controlled by one switch
(b) One Three Pin Socket 5 Amps Plug Point on independent board
(c) All as per Item No. 14 above but with 2.5 Sqmm Copper cable and including PVC conduit for 15 Apms socket
S&F Switch Piano type polycorbonate white 1 way, 6A, 240Volts complete all as specified and as directed.
S&F of ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
S&F LED light fitting 1x20 W 220 V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F MCB SPN 6 to 32A, 10KA rupturing capacity complete all as specified and as directed.
S&F MCB SP 6 to 32A, 10KA rupturing capacity complete all as specified and as directed.
M&L for Earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 32 mm x 6 mm GI iron strip earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40 mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 cm x 42 cm x 10 cm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways with 10 mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion including taking out existing earthing pit complete all as specified and as directed. (Note :- GI earth strip upto 7.5 mtr including testing consider in this item).
Bib tap standard of PTMT any colour high pressure screwd for iron pipe and fixed.(minimum weight 15mm-90gms/20mm-125gms)
Supply and lay GI tubing medium grade 15 mm dia with all fittings laid in trenches roof/floors in any length all as specified and directed
Suppy, installation testing & commissioning of retrofitting of emmission control device suitable for existng make and model DG set ehaust manifold (including necessary addition /alteration of as suitable according site condition and existing DG set model). The device should have emmission limits with NO + HC < 4.0 , CO < 3.5, PM < 0.2 g/k W-hr, and smoke limit ( Light Absorption Coefficient, M as existing CPCB guidelines for following capacity Dg sets all specified and directed. Note The emmission control device must be tested as per laid down standard of CPCB Norms
(a) Retrofitting of emmission control device for 100 KVA DG set
(b) Retrofitting of emmission control device for 125 KVA DG set
M&L for maintenance free chemical earthing with 3Nos of copper claded 17.2 mm dia nickel cadmium steel with high tensile strength electrode of each of 3.0 m with suitable compressive coupler planted at depth not less that 3 .0 m depth and duly covered with low resistant superior conductive powdered non corrosive, conducrete brand (imported form Canada) earth enhancing material all as directed and as per McML brand cat part specifications including connecting up to the common bus bar for a length upto 7.5 m with copper strip of size 25 x 4mm to achieve an earth resistance of below 1.0 ohms.
(i) Electrode and copper strip of size 25 x 4 mm shall be welded using exothermic welding for interconnecting the earth electrodes and from earth to grid point up to7.5 m along with 40 mm dia GI light grade protection pipe.
(ii) The carbon based compound shall have a resistance value of less than 0.1 ohm. The compound shall be of minimum 30 kg per pit.
(iii) The bore hole for earth electrode shall not be less than 100 mm dia and 2mtr deep from GL and the extended rod shall be driven to a total depth of 3 mtr.
(iv) Provn of earth pit chamber of internal size 150 x 150 x 150 mm depth with PCC 1:3:6 cover slab 40 mm thick with re-enforcement of 8mm TMT bars @ 100mm c/c both direction for each Earthing all as directed by Engineer-in-charge.
(v) Necessary earth work excavation in any type of soil, returning filling and making good the surrounding area complete.
(vi) All the joints Except test point shall be welded/ brazed properly and the copper earth strip whenever laid on the wall, floor etc shall be fixed on ceramic insulators not more than 600mm apart.
(vii) The contractor shall have to give guarantee for maintaining earth resistance of less than one ohm for a period of 05 years certified date of completion and to deposit security deposit of Rs 2000/- per each grid for a period of five years.
Note (i) Three Nos earthing shall be made for each grid and it shall be connected together for obtaining lowest earth resistance which shall be less than one ohm.
M&L prepairing the earth pits by welding(exothermic) additional length copper strip of 25x4mm upto the test point duly brazed by nuts ,bolts ,washers including constructing PCC (1:3:6) type C1 chamber of size 45cm X 45cm X 45cm including, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil &waste material to distance not exc 50 mtr.all as directed.
Supply and Fix DMC / FRP insulators, of suitable size to seperate the earth strips from the walls, duly screwed on the walls and making holes in the earth strips by drilling and fixing the earth strip rigidly with the insulators with GI bolts, nuts, washers etc complete all as specifed and directed.
M&L for Point wiring complete with 1.5 sqmm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through and including stove enamelled steel conduit and conduit accessories ISI marked fixed on wall / ceiling/ roof etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc, complete all as specified
Note : The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
(a) One light point controlled by one switch
Supply and Fixing only Switch flame proof rotary type with termination box in LM6, 16A, single pole 250 V complete all as directed
S & F DB with sheet metal enclosure 240 volts, 6 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete. Distribution Board shall be fitted out side of the explosive store complete all as directed.
S&F of flame proof LED tube light fitting 1x16 to 20W , 230 V including integral reflector made of aluminium alloy LM 6, with all connected accessories and all accessories pre-wired, connecting up with FRLS flexible copper conductor with suitable size all as specified and directed.
M&L for shifting of existing wall split unit indoor/outdoor AC complete with cordless remote control unit for operation on 230 volts, 50 Hz single phase AC supply and outdoor (condensing) unit to be installed on 25mmx25mmx 3mm new angle iron frame fixed on brackets duly painted complete in all respect of all including refilling of gas and copper refrigerant pipes for suction & discharge lines of standed size as requried duly insulated condensate water outlet PVC pipe laid up to ground level and 3 core copper wire of reqired lenght for stabiliser to indoor/outdoor unit all as specified and as directed.
M&L Motor starter 16 Amp 2 module including necessary metal box and cover plate all as directed
M&L single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 AMP 240 V 50 Hz AC complete all as directed.
M&L for Sub Main wiring with two runs of 6sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic casing & caping (as per site requirement) of suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge.
Note:-(i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
(iii) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint.
Dismantling wall and ceiling boards( fibre, pulp,insulation,etc) or insulation boards/slabs/blankets, any thickness,including cover fillets/scantling and uframed work etc of any description any type complete all as specified and as directed
Providing & fixing 12mm thick micro tegular false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99%, NRC0 .50 to 0.75 as per IS 8225 :1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1OOOmm length and L- shape level adjuster of size 85x25x2mm . Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications , drawing and as per directions of the Engineer-in-Charge.
M&L for fix in repairs 18/19mm thick Perforated particle board/tiles for insulation and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete aa as specified.
M&L for 25mm thick duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following:- (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
M&L for fix in reapirs IInd class HW of sectional area exc 13 sqcm but n.exc 25 sqcm Plain fillets square, rectangular or triangular in section, clean sawn, fixed with screw
S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as per specified and as directed by Engineer-in-Charge.
S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making openabled/sliding/fixed for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket and necessary Builder hardwares required for functioning etc, with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make , fixing with dash fasteners of required dia and size, including necessary fittings, stays, locking arrangement, rooler etc filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as per specified and as directed by Engineer-in-Charge.
S&F for 12mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice lamination in aluminium doors/partition complete all as specified and directed
S&F for 5.50 mm thick sheet glass, ordinary quality and glazing in aluminium door frames with beading not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Roughening to old concrete floor surface by hammer and cleaning by picking, sweeping clean and washing down with water to remove dust etc.
M&L for vitrified tiles light shade 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white/ coloured cement, laid over and including cement screed bed 15mm thick in cement mortar 1:4, complete all as specified.
S&F of Modular Switch type polycorbonate white 1 way, 6A, 240Volts complete all as specified.
S&F of Modular Switch type polycorbonate white 1 way, 16A, 240Volts complete all as specified.
S&F of Modular Socket outlet polycorbonate white 10A - 2/3 pin complete all as specified.
S&F of Modular Socket outlet polycorbonate white 20A - 2/3 pin complete all as specified.
M&L PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified & directed by Engineer-in-Charge.
M&L precast cement concrete block masonry exc. 10 cm width with solid block C1 (1:3:6) (using 20 mm graded stone aggregate) and setting in cement mortar (1:6) all as specified and as directed.
M&L 16 to 18mm thick granite stone (of any type ) work (table rubbed and polished) in floors, staircase tread & risers of steps, cooking platform, window cill/jambs etc incl 15 mm thick backing coat in CM (1:3) & pointed in white/coloured cement to match coloured tiles including Rounding, grinding and mirror polishing complete. (Note : Colour of granite shall be as approved by Engr-In-Charge)
Lettring, bordering, Emblem ingraining on granite stone with epoxy complete all as specified.
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 120 sqmm 3.5 core all as directed
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 70 sqmm 3.5 core all as directed.
Design, supply, erection, testing and commissioning of outdoor type LT feeder pillar box platform mounted (to be mounted on the P.C.C. brick pedestal), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating not less then 500 amps, Spreader link to incoming/outgoing MCCB for termination of incoming/outgoing cable and Aluminium connecting bars of suitable size (R-Y-B-N) for outgoing cables, duly fabricated in a CPRI approved / certified factory having modern fabrication and testing facility which includes at least seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron)with approved shade of RAL 7032. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel angle (50x50x5mm) legs of length 30 cm at bottom, suitable for mounting on the pedestal, The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation, including taking down old unserviceable. The feeder pillar shall be comprising of the followings :-
(i) Incoming : MCCB, 4 pole, 250 Amps, 415 Volts, 25 KA, with adjustable setting, – 01(One) No.
(ii) Outgoing : MCCB, 4 Pole, 160 Amps, 415 Volts, 25 KA, with adjustable setting, – 02(Two) Nos.
(iii) Outgoing : MCCB, 4 Pole, 125 Amps, 415 Volts, 16 KA, with adjustable setting, – 01(One) No.
(vi) LED indicating lamps with holder for main supply - 1Set of 3
(vi) Change Over 160 Amps - 01 Nos
Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25m below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 32 x 6 mm as earth lead by means of brazing etc all as shown in electrical plate No 3 connected to earthing test point as specified or indicated including testing on completion. Note:- (1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. 3) All the joints should be brazed only brass nuts/ bolts/ washers can be used in the test point complete all as specified and as directed.
M & L for Double Wall Corrugated (DWC) pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc of bore 110 / 93 mm, complete all as specified and as directed
M&L for cutting of road / hard standing upto 0.3m in depth and 0.3m wide for laying of cable protection pipe including refilling, watering, well ramming and finishing with PCC 1:2:4 and matching with surroundings, removing the broken P.C.C / road materials and clearing the site complete all as directed by Engineer-in-Charge.
Supply and install hi wall split air conditioner units capacity 1.5 TR indoor/outdoor complete with cordless remote control unit and with inbuilt air ioniser and plasma filter to better indoor air quality with minimum 5 star rating Engineer-in- Charge 3.2 complete all as specified and directed
Voltage stabilizer for automatic operation single phase air cooled indoor typr & designed input variation between 130 V to 300 V with output voltage stabilizer at 230 volts with accuracy of +/- 2.5 and of capacity 4 KVA. Including high / low Voltage cut out timely delay
Supply ,Fixing, Testing and commissioning of open well Submersible pump set, electric driven 415 V, 3 phase minimum discharge capacity 2000LPM with minimum head 20 mtrs complete of capacity of 12.5 HP.
Supply and fixing of Submersible cable, PVC insulated, PVC sheathed 1100 volts grade, multistranded copper conductor flat, 3 core 6 Sqmm complete all as specified and as directed.
Supply, install, testing and commissioning of LT Panel board outdoor type made out of 3.15 mm thick CRCA Sheet and MS angle iron frame with weather proof canopy, mounted on PCC pedestal, Cubical type, front and rear side openable, compartment type with hinged door lifting lugs 2 Nos, earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc and passivated nut, bolts, spring and washers and locking arrangement for each compartment, provision of air vent, dust and vermin proof, provision of cable alley with 300 Amps rated Aluminium bus bar for phase and 100 Amps for nuetral having 1100 Volts grade sleaving and internal connection should be provided with aluminium strips of suitable size to accomodate and including the following duly painted with 2 coats powder coating over a coat of anti corrosive red oxide primer should accomodate the following accessories.
MCCB 100 amps, 415 Volts, 50 Hz, 25 KA (Incoming) - 01 Nos
Star Delta Starter suitable for 12.5 HP - 02 No Make : BCH/Seimen
Single phase preventor 02 No Make PowerTech / Minilec
Digital type Ammeter 0-100 Amps with CT - 01 Nos
LED type indication lamps with switches and fuses (R,Y,B) - 01 Set
Note:- (i) The rate quoted is inclusive of necessary CTs, Control wiring and instrument fuse holder.
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core.
Supply, Laying, jointing and testing GI pipes of size 80 mm medium grade laid in floor/roofs etc in any length with screwed and socket joints together with and including with all galvanised steel fittings such as sockets, elbows, bends, tees, reduces, short pieces, unions, caps, plugs etc all as specified and directed
M & L for mild steel framed work for any description including necessary cutting,welding,jointing and making proper support of vertical delivery pipe line including clamps,nuts,bolts etc. And painting two coats with black synthetic paint over a coat of red oxide primer complete of Gde Fe-410 W (quality - A) all as specified and as directed
M&L for PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) as in coping, bed plates, etc., including weathering, slightly rounded or chamfered angles and throating, necessary form work for LT pannel foundation etc. complete all as specified and as directed.
Cutting existing PCC hard standing for making duct for laying LT XLPE cable of size 25 sqmm 4 core for LT panel all as specified and directed.
M & L for light grade galvnised pipe ISI Marked with all fitting laid in trenches under road or fixing on wall/floor, crossing nallah etc for bore 40 MM complete all as specified and as directed.
L and S ENTERPRISES
Dwarka Pershad Radhey Ramanlal
Saiansh Associates
M/s Amit Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .