Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.9 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹3.0 L+₹6,250 (2.16%)Rejected-AOC | 2 | Rejected-AOC L2 | |
| 3 | 3₹3.4 L+₹48,411 (16.7%)Rejected-AOC JAMMU AND KASHMIR JAMMU AND KASHMIR | JAMMU | JAMMU AND KASHMIR | 181122 | 3 | Rejected-AOC L3 | |
| 4 | 4₹3.5 L+₹57,051 (19.7%)Rejected-AOC H NO 92 LANE NO 17 HARI NAGAR TALAB TILLO JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | 4 | Rejected-AOC L4 | |
| 5 | Not Admitted-Fee/PreQual/Technical 213 BAHARTI NAGAR SUBASH NAGAR JAMMU JAMMU JAMMU JAMMU KASHMIR 180007 | JAMMU | JAMMU AND KASHMIR | 180007 | - | Not Admitted-Fee/PreQual/Technical Others-not uploaded relevant experience |
Tender Value
Refer Docs
Closing Date
17 Aug 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer MID Akhnoor/Nowsh
Office of the Executive Engineer MID Akhnoor/Nowshera
Upgradation by way of providing/fitting of protection panel cum automatic star delta Starters for pumping unit no. 01 02 with allied works at LIS Meeni
2022_IFC_181147_1
60/MID/AN
Open Tender
Machineries/ Mechanical Engg Items
Item Wise
AKHNOOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Office of the Executive Engineer MID Akhnoor/Nowsh
Exempted
Office of the Executive Engineer MID Akhnoor/Nowsh
20 Sept 2022
27 Jul 2022
18 Aug 2022
27 Jul 2022
17 Aug 2022
2 Aug 2022
29 Jul 2022
Upgradation by way of providing/fitting of protection panel cum automatic star delta Starters for pumping unit no. 01 & 02 with allied works at LIS Meeni Description of panel Designing, fabrication, installation, testing and commissioning of LT control panel 415 volts, AC-3 Phase, 50 Hz. for pumping unit no. 01 & 02 at L.I.S Meeni. The panel shall be dust and vermin proof fabricated out of 16 SWG CR Sheet supported on M.S. angle of suitable size and having provision for fixing it on the ground with the help of foundation bolts. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking /sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should be given two coats of anti rust primer and two coats of steel grey enamel paint. The panel should have equipped with following components / features: M.C.C.B.The panel should be fitted with an M.C.C.B. of 250 Ampere capacity, 1 no. volt meter, 1 no ammeter along with a set of CTs, 1 No. V.S.S., 1 No. A.S. switch and a set of RYB indicators at incoming side including the bus bars . Outgoing no. 1 : The panel should be fitted with a 50 HP automatic star delta starter comprises of 3 Nos. air break contactors compatible with 50HP induction motor (2 nos. 80 A for main and delta supply, 1 No. air break contactor 70A for star operation), 1 No. timer for change over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor, 1 No. indicator .1 No. MCB for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables/ bus bars to complete the star delta circuit of out going supply for pumping unit no. 1 Outgoing no. 2: The panel should be fitted with a 50 HP automatic star delta starter comprises of 3 Nos. air break contactors compatible with 50HP induction motor (2 nos. 80 A for main and delta supply, 1 No. air break contactor 70A for star operation), 1 No. timer for change over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor, 1 No. indicator .1 No. MCB for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables/ bus bars to complete the star delta circuit of out going supply for pumping unit no. 2 Protections device / fault analyzer : A protections devise / fault analyzer shall be fitted with the panel with capability to protect each motor by isolating the power supply of motor by de-energizing the starter/panel from following electro-mechanical faults which may otherwise damage the motor windings : A. Voltage related fault: Single phasing, under voltage, over voltage, unMeeniance voltage. B. Current related fault: Over current / load, dry running, unMeeniance current / load, earth leakage, short circuiting. C. Display line current of RYB Phase and also line voltage of RY ,YB and BR phase. Bimetal overload relay: Bimetal over load relay of suitable range should be fitted with in the each starter as an extra protection to protect the motors in case of failure of fault analyzer . The job also includes Providing/ fitting of 25 sq mm single core copper cable ( 24 mtrs. approx.) from starter no. 01 &02 to motor no. 1 &2 as per site conditions. Complete job includes cost of providing/ fitting ,transportation charges ,hire charges of tool and tackles charges, hire charges of skilled and unskilled labour, and all kinds of taxes thereof. complete job Make of MCCB – Any reputed make as per ISO standards.. Make of contactor – Any reputed make as per ISO standards... Make of cable – Any reputed make as per ISO standards.. .
SMART TECH AND CO
SUNIL KUMAR SURI CONTRACTOR
JAY AAR ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .