Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹7.4 L+₹21,040 (2.91%)Rejected-Finance PO BUD BUD DIST BURDWAN WEST BENGAL PIN 713 403 | BUD BUD | BURDWAN | WEST BENGAL | 713403 | L2 | Rejected-Finance Due to L2 | |
| 3 | L3₹8.7 L+₹1.4 L (19.6%)Rejected-Finance 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L3 | Rejected-Finance Due to L3 |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
2 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Vinay Gupta GE
GARRISON ENGINEER AIR FORCE PANAGARH MES AIR FORCE STATION PANAGARH POST BIRUDIHA DIST BURDWAN WEST BENGAL 713148
REPAIR AND CLEANING OF SEWAGE LINE AND ALLIED WORKS AT AF STN ARJAN SINGH
2021_MES_409468_1
8617/E8
Open Tender
Civil Works - Water Works
Item Rate
330 days
AF Station Panagarh
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF Panagarh
₹18,000
Yes
17 Feb 2021
5 Jan 2021
4 Feb 2021
5 Jan 2021
2 Feb 2021
19 Jan 2021
60 days
Amount
Labour only for cleaning the blockage of NT/FT including clearing the waste pipe line upto gully trap including necessary tools etc.and make it service completed.
Labour only for cleaning the blockage of EWC/IWC including clearing the soil pipe line upto first manhole trap including necessary tools etc.and make it service completed.
Mechanical Cleaning of Septic Tank of capacity 25 users by using Mobile High Pressure Super Sucker Machine consisting of two tanks (a water tank and a sludge tank), or alternatively two vehicles (Super Sucker unit and Dump Tanks), a high pressure water jet pump and a high flow jetting blower or vacuum pump for suction. Pumping out Sewage Water, accumulated Night Soil, Sludge’s, (both Solid and Liquid) and other obstructive materials into dump tank and removing to outside of Defence land immediately for disposal, re-fixing the Cover after complete Cleaning of Septic Tank, complete all as specified and as directed by Engr-in-Charge. Note :- 1. After removal of the sludges from the pits, the septic tank to be cleaned thoroughly with water. 2. Cleaning to be confirmed by the Engr-in-Charge of the work. 3. Care shall be given to maintain hygeinic condition while removing sludge/foul materials to outside of Defence land. 4. Dates of measurment and location shall be recorded commensurate with users certificate of compliance in a register duly signed by the contractor & Engr-in-charge. 5. Cleaning of tanks once carried out shall not be repeated without written request of the user and approval of Engr-in-charge/GE. 6. Contractor should quote rate on whole job basis.
All as per Item No. 1 here-in-above but of capacity 50 Users.
All as per Item No. 1 here-in-above but of capacity 100 Users.
Cleaning of existing sewage lines of any depth by roding manually or with machine as required at site from manhole to manhole, removing blockage of any type , flushing the line with pressure water jets and making the line fully functional complete all as specified and as directed by Engineer-in-charge
Cleaning of Manhole depth not exc. 1.50 METRE by opening Cover and Taking out accumulated sludge Brick Bats, Garbage, Silts or any Other Items, removing and carrying same to a distance exc 250.00 METRE but not exc. 500.00 METRE, and buried under Ground (minimum 300 mm below Ground Level), Sprinkling Bleaching Powder on deposited Sludge’s at Pit including Excavation of Pits, Returning, Filling in and dress-ing of Surplus Soil/Ground to Slope as required, again Spreading Bleaching Powder on Filled Earth and upto 1.00 METRE around the Trenches/Pit not less than 500 GRAMS PER SQUARE METRE,, re-fixing the Cover after Cleaning of Manhole, complete all as specified and as directed.
Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 mtr in depth and getting out soft/loose soil complete all as specified.
Returning, filling in, trenches including Spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick all as specified.
Removing of surplus soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.50 metre above the starting point all as specified.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified.
Material and labour for Brick Work with fly ash bricks’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 METRE mean Radius, built in Cement Mortar (1:4), complete all as specified and as directed.
All as per Item No. 12 here-in-above but except bricks.
Material and labour for 15 mm thick Rendering on brick wall or concrete wall in Cement Mortar (1:4), finished the Surfaces even and smooth without using extra cement complete all as specified.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified.
Demolition/Breaking up Drain Pipes (Salt Glazed Ware) 150mm Bore (dia), Jointed in Cement Mortar of any description including PCC of Packing and Haunching to Sides of the Pipes with Bed, complete all as specified and as directed.
Material and labour for Salt-Glazed Stoneware Drain Pipes of Internal dia 150mm, Grade ‘A’, laid in Trenches in Foul Condition, Jointed in Cement Mortar 1:1 complete all as specified and as directed.
Material and labour for cement Concrete (1:3:6) Type C1 (20mm Graded Stone Aggregate) Bed for Drain Pipes of Bore 150mm including Packing under and Haunching against the Sides of Pipes after they are laid in Foul Condition and Testing, complete all as specified and as directed.
Demolition of plain cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) as directed by Engineer-In-Charge.
Material and labour for cement concrete type B-0,1:2:4 (12.5mm graded aggregate) as in coping incl surface channel of drain and manhole including necessary formwork complete
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for as directed by Engineer-In-Charge.
Material and labour for providing precast Re-inforced cement concrete type B-1, 1:2:4 (Using 20mm Graded Stone Aggregate),set in Cement Mortar 1:4 as in cover slab for manholes, drain, septic tank/soak well all as specified.
Material and labour for Mild steel TMT bars of Fe 500 or Fe 500D, 8 mm to 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified.
Cleaning of SWT by pumping out water and desilting including removing of silt to a distance exceeding 50mtr and n.exc 100mtr and applying bleaching powder after cleaning of SWT all as directed by Engr-in-Charge. Note : For measurement purpose, only volume of SWT will be measured
Supply and fix framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified.
Supply and fix in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joint and including necessary bends as required fixed to wall complete all as specified. Note: Bend shall be measured and paid separately.
Supply and fix in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joint and including necessary bends as required laid in trenches or in floors complete all as specified. Note: Bend shall be measured and paid separately.
Supply and fix in repairs Salt-glazed stoneware gully traps, square or round mouthed, tvpe 'S' of size 150 x 150mm setting and jointed with solvent cement complete all as direcred by Engr-in-Charge.
Supply only 110 mm bore PVC (SWR) bends of any radius with oval access door complete all as specified.
Supply and fix in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joint and including necessary bends as required laid in trenches or in floors complete all as specified. Note: Bend shall be measured and paid separately.
Supply only 75 mm bore PVC (SWR) bends of any radius with oval access door complete all as specified.
Supply and fix as in repairs Vitreous China wash down water closet pan (pedestal pattern),white (including fixing bolts, flushing cistern,flush pipe, PVC sheet cover) including 'P' or 'S' trap connecting to union of flushing cistern and drain pipe as directed by Engineer-In-Charge. Make of Pan Jquar/ Marc/ Johnshon
Supply and fix as in repairs vitreous china squatting pan of Orrisa pattern size 580 mm x 440 mm, white, with integral foot rests (including flushing cistern and flush pipe) including 'P' or 'S' trap and lime concrete bedding connection making good to floor all as specified. Make Parryware Cat No C0117* / Cera Cat No CADELL S3020102/ Johnshon Cat No P0461PW* OP23
Supply and fix in repairs of PVC(SWR) cowls including jointing with solvent cement, suitable for 110 mm bore pipe.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed and specified.
Material and labour for 7 mm to 8 mm thick premium quality anti skid ceramic coloured tiles of size 300 mm x 300 mm , confirming to IS-13755 with water absorption of 3%< E < 6% Group (B II a) laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 20 mm thick screed bed in CM(1:6) complete all as specified
Material and labour for joint free premium quality glazed ceramic tiles (coloured) of size 450 mm x350 mm x 7mm confirming to IS-13755 with water absorption of E> 10% Group (B III) as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick backing coat in CM (1:3) complete all as specified
Supply and fix vitreous China urinals, bowl type urinal flat back,minimum size of 440 mm x 345 mm x 250 mm white , with grating and union for discharge pipe (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; complete all as specified. Make Parryware Cat No C0501*/ Johnshon Cat No CNS-WHT-801/ Cera Cat No S4030101
Supply and fix PVC (SWR) floor trap for 75mm outlet dia, plain with grating including jointing with solvent cement including taking out the existing one.
Supply and fix in repairs Grating doom 150 mm dia of PTMT (Minimum weight 25gms)
ROY ENTERPRISE
R K CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .