| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹23.2 L+₹1.9 L (9.06%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹26.3 L+₹5.0 L (23.3%)Rejected-Finance N A | NA | NA | 121004 | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹26.9 L+₹5.6 L (26.2%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹28.9 L+₹7.6 L (35.8%)Rejected-Finance PLOT NO RZ B 1 59 KH NO 534 535 BLOCK B 1 NEW ROHANPURA PP NO 1416 NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹33.3 L
EMD Value
₹66,600
Closing Date
14 Mar 2020, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
SPECIAL REPAIR TO BLDG NO. P-184 P-185 AND P-186 (THREE COOK HOUSE) OF 11 RAJRIF PROVN OF SEPTIC TANK WITH SOAKAGE WELL EACH NEAR BLDG NO P-13 AND P-28 JCOS/OR MD ACCN DUNDAHERA MILITARY STN PROVN OF LIGHTENING CONDUCTER IN BATTALION MAGZINE OF 5 MLI
2020_MES_319504_2
GE/DS-93/2019-20
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹66,600
Yes
25 Aug 2020
22 Feb 2020
16 Mar 2020
22 Feb 2020
14 Mar 2020
29 Feb 2020
23 Feb 2020 - 27 Feb 2020
Amount
M&L for Demolition of mud in roof, any thickness, including, tiles plastering and leeping upto three storey bldg incl necessary scaffolding arrangement complete all as specified and directed(whether full thickness removed or only a part there of) and removing rubbish out side the cantonment area complete all as specified and directed by Engr-in-Charge.
M&L 40 mm thick (average thickness) Cement concrete type B-0,1:2:4 (12.50mm graded stone aggregate) as in flooring/ roof pedding , finished even and smooth without using extra cement ,including cleaning the concrete surface by steel wire brushes, up to three stories bldgs, complete all as specified and directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises out side at cantonment area complete all as specified and directed by Engr-in-Charge.
Roughening surfaces of old concrete floor/wall by picking, sweeping clean and washing down with water to remove dust, etc and brushing and applying neat cement slurry with 3.0 Kg of cement per sq metre complete all as specified and directed by Engr-in-Charge.
20mm thick granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills, cooking platforms and like in CM 1:4 including pointing in white cement 1:2 using marbal dust with admixture of pigment to match with shade of granite including 15mm thick screed bed in CM (1:6) complete all as specified and directed by Engr-in-Charge.
M&L for Non skid ceramic joint free coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry with 3.00 kg per sqm and pointed in white or coloured cement to match over 15mm thick screed bed in CM(1:6) complete all as specified and directed by Engr-in-Charge.
M&L for Non skid ceramic coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm as in Vertical Surface such as skirting/Dado etc. set and jointed in neat cement slurry with 3.00 kg per sqm and pointed in white or coloured cement to match over 10 mm thick rendering in CM(1:4) complete all as specified and directed by Engr-in-Charge.
M&L for Non skid ceramic coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 sqm as in floor. set and jointed in neat cement slurry with 3.00 kg per sqm and pointed in white or coloured cement to match over 15 mm thick screed bed in CM(1:6) complete all as specified and directed by Engr-in-Charge.
M&L for Coloured Glazed ceramic tiles in vertical surface 450 x 300 x 7 mm thick, as in skirting/Dado laid on 10 mm thick rendering in CM (1:4), set and jointed in neat cement slurry at the rate of 3 kg per sqm and pointed in white/coloured cement to match the shade of tiles complete all as specified and directed by Engr-in-Charge.
M&L for Grinding including rubbing of existing kota stone flooring by Electrical operated grinder and there after applying polishing complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store, 15mm bore, complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store, 20 mm bore, complete all as specified and directed by Engr-in-Charge.
15mm bore steel tubes, (medium grade), galvanised, with all fittings and fixtures complete to walls and ceilings or laid in floors trench or concealed in wall complete all as specified and directed by Engr-in-Charge.
15mm bore steel tubes, `medium grade', galvanised, with all fittings and fixtures complete to walls and ceilings or laid in floors trench or concealed in wall complete all as specified and directed by Engr-in-Charge.
Cutting chases, pinning in, in brick walls, making good to facings where required and pointing in cement mortar1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engr-in-Charge.
Dismantling water tanks of capacity exceeding 500 litres but not exceeding 1000 litres complete all as specified and directed by Engr-in-Charge.
Rotational moulded polyethlene water storage tanks three layers (cylindrical vertical with closed top) hoisted and fixed in position screwed for iron pipe or brass ferrule and fixed all as specified in SSR Part-I of 1000 litres capacity, complete all as specified and directed by Engr-in-Charge.
Ball valves 20mm dia , high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed of minimum weight 210 gms complete all as specified and directed by Engr-in-Charge.
S&F in repairs Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20 mm bore complete all as specified and directed by Engr-in-Charge.
S&F PVC connections 450mm long with PTMT union at both ends suitable for 15mm bore pipe, complete all as specified and directed by Engr-in-Charge.
S&F in repair 15 mm angle stop valves, cast copper alloy , chromium palted, fancy type screwed down high pressure with crutch and butter fly handles , screwed with iron pipes or for union complete all as specified and directed by Engr-in-Charge.
S&F in repairs bib tap, brass chromium plated fancy type, long body screwed down, screwed for iron pipe 15 mm bore complete all as specified and directed by Engr-in-Charge.
S&F in repair, PVC valveless , syphonic action type flushing cisterns 10 ltrs capacity , low level , white, with inlet ball valves , float and handle including brackets and pvc flush pipe 32 mm dia for low level complete all as specified and directed by Engr-in-Charge.
S & F in repair Vitreous china wash basin, white, flat back, size 550 x 400mm, including necessary waste pipe and coupling, brackets and cutting for and pinning in ends of brackets, complete all as specified and directed by Engr-in-Charge.
Taking down rain water pipe (any size) or pattern incl all fittings, head shoes, bends swan necks etc incl cleaning or re-fixing or removal to store(measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) pipes, 110mm dia single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed by Engr-in-Charge.
PVC(SWR) bends/Tee any radius, 110mm bore complete all as specified and directed by Engr-in-Charge.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed by Engr-in-Charge.
Taking down chowkats for frame with shutters (without taking off shutter from the frame) exceeding 1.50 Sqm but not exc 4 Sqm each complete all as specified and directed by Engr-in-Charge.
S&F Pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engr-in-Charge.
S&F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube ,supplying and fixing in opening as per specification and drawing complete all as specified and directed by Engr-in-Charge.
Second class hardwood, Glazed and skeleton shutters ,35mm thick, open rebated and prepared to receive glass gauze, etc.divded into squares plain, cham-fered or rounded, mitred and rebated sash bars, any numbers and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed by Engr-in-Charge.
S&F, Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tube for top and bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strips of 20 mm with stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail , lock rail & bottom rail on either side & as gap inserted for top rail & bottom rail , panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement in the frame at the site as per specification & drawing complete all as specified and directed by Engr-in-Charge.
S&F stainless steel butt hinge (ISI Marked) size 100 mm complete all as specified and directed by Engr-in-Charge.
S&F Aluminium anodised barrel tower bolts (ISI Marked) 150 mm long , of extruded section and fixed complete all as specified and directed by Engr-in-Charge.
S&F Aluminium handles (ISI Marked), 150 mm size, Fabricated type ,complete all as specified and directed by Engr-in-Charge.
S&F aluminium alloy anodised sliding door bolts of 250 mm long with hasp,staple (bolt type) fixing clips of sheet cast or extruded section , fixing bolts and sliding bolts of extruded section and fixed complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new wooden surfaces of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge.
Hacking out old broken glass (any thk,size,quality or description ) from metal frame incl punching out or drilling out old glazing pins /springs clips complete all as specified and directed by Engr-in-Charge.
M&L for 3.0 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane complete all a specified and directed complete all as specified and directed by Engr-in-Charge.
S&F in repair stainless steel wire cloth, 0.63mm nominal dia of wire and average width or aperature 1.40 mm, fixed with tinned tacks or galvanised wire staples in doors/steel windows complete all as specified and directed by Engr-in-Charge.
M&L for Welding exc 2.5 cm but not exc 5 cm in length and thickness of metal be welded exc 6mm but n.exc 9mm, complete all as specified and directed by Engr-in-Charge.
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr-in-Charge.
M&L for Rendering 15mm thick in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for Rendering 5mm thick in cement mortar 1: 3 on concrete surfaces of ceiling,chajja,etc finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed by Engr-in-Charge.
M&L for preparaing newly plastered surfaces on walls and applying three coats of white wash complete all as specified and directed by Engr-in-Charge.
M&L for Complete removal of existing treatment , from internal surfaces of walls/ceiling through electrically operated grinder/sand paper, steel patti, wahsing complete all as specified and directed by Engr-in-Charge.
M&L for preparation of surface as filling of holes with filler material and applying 3mm thick wall care putty in two layers inlcuding grinding with sand paper & levelling of surface complete all as specified and directed by Engr-in-Charge.
M&L for applying two coats of distemper oil emulsion, on white or tinted over existing prepared putty base surface complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old surfacace and applying three coats of white wash on walls complete all as specified and directed by Engr-in-Charge.
M&L for preparion of surface as filling of holes with filler material etc and applying three coats of white wash as in ceiling complete all as specified and directed by Engr-in-Charge.
M&L for complete removal of existing treatment on walls by electrical grinder/ sand paper/ steel patti thereafter prepartion of walls by filling of holes and cracks with wall care putty, specified for external surface as required area of surface and applying two coats of Cement base paint over a coat of cement primer complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old wooden surfaces of any description not otherwise described over 10 cm width or girth and apply one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old Steel surfaces of any description not otherwise described over 10 cm width or girth and apply one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc for manholes, pipes, wells etc not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in any type of soil, complete all as specified and directed by Engr-in-Charge.
All as per item No 56 above but exc 1.5m depth, but n.exc 3m depth complete all as specified and directed by Engr-in-Charge.
Returning, filling in, inluding spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25cm thick each in trenches, after the pipes have been laid and tested, complete all as specified and directed by Engr-in-Charge.
Removing excavated material any type of soil exc 50 m but not exc 250 m deposited where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
M&L for Brick work with sub class 'B' bricks strainght or curved on plan not exceeding 6m mean radius built in cement mortor 1:6 complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brickwork/ concrete surface, finished even and smooh without using extra cement, complete all as specified and directed by Engr-in-Charge.
Supply only integral water proofing compound, complete all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping and similar work etc. including weathering, slightly rounded or chamferred angles and throating and including necessary formwork, complete all as specified and directed by Engr-in-Charge.
M&L for Precast reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in cover slab etc. set laid and dry, including necessary formwork, complete all as specified and directed by Engr-in-Charge. Note : (i) Reinfocement shall be measured and paid seperately.
M&L for Mild steel TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including muld seel wire (annealed) not less than 0.9mm dia, complete all as specified and directed by Engr-in-Charge.
M&L for Mild steel of Gde Fe-290 (Gde E-165) as in bend, straps, rungs, handle, holdfast, manhole cover frame and similar small articles, complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete (1:4:8) , type D-2, using 40mm grade stone aggregate as in concrete bed to drain pipes laid to falls in trenches in any depth including packing under and haunching against the sides of pipes for 150mm bore pipes with concrete after the pipes are laid and tested, complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete (1:4:8) , type D-2, using 40mm grade stone aggregate as in concrete bed to drain pipes laid to falls in trenches in any depth including packing under and haunching against the sides of pipes for 200mm bore pipes with concrete after the pipes are laid and tested, complete all as specified and directed by Engr-in-Charge.
M&L for SGSW drain pipes 150mm dia laid in trenches and jointed in CM (1:3), complete all as specified and directed by Engr-in-Charge.
M&L for SGSW drain pipes 200mm dia laid in trenches and jointed in CM (1:3), complete all as specified and directed by Engr-in-Charge.
M&L for reinforced concrete pipes 200mm dia, class NP2, laid in trenches and jointed in CM (1:3), complete all as specified and directed by Engr-in-Charge.
M&L Plain cement concrete(1:2:4) type B-I using 20mm graded stone aggregate as surface channel/drains inside the manholes and like including weathering, slightly rounded or chamfered angles and throating as directed and provision of necessary formwork to any extent and finished exposed surface even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge.
Extra over surface channel inside of manholes for forming fair finished drains of channels 30 cm inner girth in cement concrete using extra cement inclding forms, moulds, mitred/stopped ends, complete all as specified and directed. (Inner girth only be measured and paid), complete all as specified and directed by Engr-in-Charge.
Construction of septic tank in ordinary soil, foundation in PCC (1:2:4), for 25 users, brick work in CM 1 : 4 (with top of slab at ground level) including necessary excavation and earth work in any type of soil and disposal of surplus soil as directed, RCC manholes covers having 6mm plate embedded all around/fibre reinforced cover with angle iron welded frame complete all as per drg No TD DZ-171, vent shaft with cowl and sludge chambers etc, complete, all as specified and directed by Engineer-in-Charge.
Construction of soakage well 2.4 mtr dia and 4.50mtr deep in ordinary soil below inlet (depth) from inlet pipe to ground level 45 cm, including excavation and earth work in any type of soil, PCC (1:3:6), type C-2 (using 40 mm graded stone aggregates) in foundation, walling honey combed , cover slab of M-25 design mix, including intercepting chamber, screen chamber in brick work in CM 1:4 , RCC cover slab in M-25 /RR masonary/filling with brick bats complete all as per drg No TD DZ-1124 (R) and directed by Engineer-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep in soft/loose soil and getting out including clearing all grass vegetation, saplings, shrubs, brush woods under growth roots and trees exceeding 30 cm girth, complete all as specified and directed by Engr-in-Charge.
M&L for 100 mm thick, cement concrete type D2, (1:4:8) 40 mm graded stone aggregate finished complete all as specified and directed by Engr-in-Charge.
M&L for chequered cement concrete tiles 20cmx 20cm x 25mm thick with gray cement and pigments , set and jointed and pointed in neat cement slurry in floors , laid over 15 mm thick cement screed bed of CM(1:4). complete all as specified and directed by Engr-in-Charge.
Taking down carefully the old u/s Aluminium/ Copper point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as specified and directed by Engr-in-Charge.
M&L for point wiring complete with single core multi strand copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 Volts grade electrical cable in and including concealed PVC conduit medium grade and sunk in new pressed steel terminal boxes of required size factory made and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet (ISI Marked) of required color with screwed and cup washer with all accessories including 1.5 Sqmm single core with multi strand copper conductor PVC unsheathed cable earth and connected to earth dolly complete for One light /fan/Bell point controlled by one way switch all as specified and directed by Engr-in-Charge Note:- The rate is inclusive cutting /chasing and making good the disturbed surface with cm 1:3 and same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash.
All as per above Ser Item No 81 but here-in-before one 3 pin socket outlet 5 Amps independent board complete all as specified and directed by Engr-in-Charge
All as per above Ser Item No 81 but here-in-before one 3 pin socket outlet 5 Amps point on same board complete all as specified and directed by Engr-in-Charge
All as per above Ser Item No 81 but here-in-before one 3 pin socket outlet, 15 Amps on independent board with cable 2.5 Sqmm for main current and 2.5 sqmm as earth wire as power point complete all as specified and directed by Engr-in-Charge.
All as per above ser Item No 81 but here-in-before cable 4 Sqmm for main current and 4 sqmm as earth wire as power point for AC/Geyser complete all as specified and directed by Engr-in-Charge.
S&F in replacement for switch piano, flush type 5 Amps single pole one way, ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in replacement for socket piano flush type 2 in 1, 3 pin, 5 Amps complete all as specified and directed by Engr-in-Charge.
S&F in replacement for switch piano, flush type 15 Amps single pole one way, ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in replacement for socket piano flush type 2 in 1, 3 pin 5&15 Amps flush type complete all as specified and directed by Engr-in-Charge.
S&F in replacement for ceiling rose surface Bakelite 65x50 three terminals, ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in replacement for ceiling fan regulator electronic type AC 230V single pole ISI marked complete all as specified and directed by Engr-in-Charge.
S&F LED Integrated Batten T5, 20 Watt, 4 Ft White, indoor decorative PVC extruded T5 LED battern -integrated type complete with including fliexble wire in replacement of old unsv existing 36 Watt tube light fitting complete all as specified and directed by Engr-in-Charge. Make: Cat Part No HLB-03--20-CW-AL of Halonix or its equivalent as specified Make
Sub main wire using FRLS insulated unsheathed mulitistrand copper conductor FRLS PVC cable 2 runs of size 6Sqmm for phase and neutral and 4 Sqmm for earthing drawn through rigid PVC casing caping/PVC condute pipe not less than 25mm dia fixed on wall/ground/ceiling etc, and complete all as specified and directed by Engr-in-Charge. Note:- Phase should be Red/Yellow /Blue, neutral should be black and earthing wire should be green colour. Two run of cable for phase /neutral and one run of cable for earth incl casing caping / conduit pipe will be measured and paid as one unit length.
S&F in replacement for sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail SPN 12 way complete all as specified and directed by Engr-in-Charge. Make : Legrand/Siemens/Hager
S&F in replacement for sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail SPN 8 way complete all as specified and directed by Engr-in-Charge. Make : Legrand/Siemens/Hager
S&F in replacement for MCB SPN 32/40 Amps 240 volts complete all as specified and directed by Engr-in-Charge. Make : Legrand/Siemens/Hager
S&F in replacement for MCB SP 5 to 40 Amps 240 volts complete all as specified and directed by Engr-in-Charge. Make : Legrand/Siemens/Hager
S&F in replacement for sheet metal enclouser MCCB DB IP 43 double door bus bar neutral link earth bar and din rail TPN 4 way complete all as specified and directed by Engr-in-Charge. Make : Cat Part No 607790 (DPX 125+12) of Legrand or its equivalent as specified make.
S&F in replacement for distribution board MCCB 125 Amps 4 pole 415 Volts 16 KA complete all as specified and directed by Engr-in-Charge. Make : Legrand/Hager/Siemens.
S&F in replacement for MCB TPN/ Isolator 4P, 63 Amps 415 volts, 'C' Series 10 KA complete all as specified and directed by Engr-in-Charge. Make : Legrand/Hager/Siemens
S&F in replacement for LED Security Light fitting 45 Watt including bracket for fixing of security light fitting of GI pipe light grade of 32/40 mm dia with suitable size of clamps, anchor faster, nut bolts and washer complete all as specified and directed by Engr-in-Charge. Make : Cat Part No : HLSLD-15-45-CWL-R of Halonix or its equivalant as specified make.
S&F in replacement for LED 6 watt white Bulk head in engineering plastic housing with clear prismatic including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and directed by Engr-in-Charge. Make : Cat Part No CG80IB6WLED of C&S or its equivalant as specified make.
S&F in replacement for ceiling fan 1200 mm sweep, 5 star rated with copper wound in White colour complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge. Make : Cat Part No Pacer of Havells or its equivalent as Bajaj/ Usha. Note : Old ceilling fan to be deposited in MES Store.
S & F in replacement for metal body exhaust fan 450 mm sweep, 230 Volts with louver and copper wound including necessary electric connection with appropriate size of PVC copper wire from ceiling rose/switch board to exhaust fan including fixing of nut-bolts of suitable size and making good the disturbed surface of wall with OBD/White wash to match with existing complete all as specified and directed by Engr-in-Charge. Make : Cat Pt No - Krypton (HDEF) of Halonix or its equivalent as specified. Note : Old Exhaust fans to be deposited in MES store.
S&F metal body exhaust fan 300 mm sweep, 230 Volts with louver and copper wound including necessary electric connection with appropriate size of PVC copper wire from ceiling rose/switch board to exhaust fan including fixing of nut-bolts of suitable size and making good the disturbed surface of wall with OBD/White wash to match with existing complete all as specified and directed by Engr-in-Charge. Make : Cat Part No : Krypton (DBB) of Halonix or its equivalent as Bajaj/ Usha. Note : Old Exhaust fans to be deposited in MES store.
S&F in replacement of water heater storage type (Geyser) of capacity 25 ltrs, BEE 5 star, body of ABS plastic material, copper inner tank, auto cat adjustable temperature, safety valve, thermal cut out input voltage 230 volts, power consumption 2 kw including all fittings 4 sets of nut, bolts and washers of monimum dia 10 mm, grouting in wall, 2 No's PVC connection 45 cm long switable for hot/cold water and two No's brass CP 15 mm bore stop valve, 01 No's NRV, 01 PRV, 01 plug top 16 Ampr and making all electric and water connection. complete with heating element, thermostat,3 core lead, Plug top, safty valve, inluding electric and water connection and making good to disturbed surface complete all as specified and directed by Engr-in-Charge. Make : Cat Part No Monza of Havells or its equivalant as specified make. Note : Old Geyser to be deposited in MES store.
Taking down of old unserviceable ceiling fan/exhaust fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site and reinstallation and testing complete all as specified and directed by Engr-in-Charge. Note : Rewinding will be measured and paid under respective item of this Schedule.
M&L for Rewinding of ceiling fan 1200 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, ball bearing where ever required and applying two coat of synthetic enamal paint first quality by using machine spray including filling cavities with filler and marking of MES number as per existing complet all as specified and directed by Engr-in-Charge.
All as per above Ser Item No 108 but here-in-before for exhaust fan 450 mm sweep complete all specified and directed by Eng-in-charge.
S&F in replacement for Batten holder with PVC body and back plate suitable for LED Bulb B-22 cap complet all as specified and directed by Engr-in-Charge. Make : Cona/Kinjal/Havells
S&F LED RETROFIT Lamp of 12 Watt for fixing in batten holder point complete all as specifed and directed by Engr-in-Charge. Make : C&S\Havells\Philips
S&F single pointed air termination copper rod of 12 mm dia 300 mm long complet all as specified and directed by Engr-in-Charge.
M&L for copper strip 20mm X 3mm for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required (all joint shall be propperly rivettted & brazed/welded) complet all as specified and directed by Engr-in-Charge.
S&F aluminium strip 32mmx6 mm complete with saddle and procelin insulator fixing & screws of or roof conductor/down conductor above ground complet all as specified and directed by Engr-in-Charge.
S&F test point terminal block made of gun metal of phosphorus bronze size 75X75X25 mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hex. Head screw complet all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanised steel earth plate 600mmX600mmX6 mm thick, buried directly in ground (earth pit not les than 2.25 M deep below normal ground level) with top edge of plate not less than 1.50 m below normal ground level, connected with GI earth strip of 32 X 6.3 mm as earthing leads by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 (duly protected with 40 mm dia light grade GI pipe upto 7.5 m from the earth plate) and connected to GI steel earth plate including charcoal dust, common salt necessary excavation in soft/looe soil, returning filling in and removal of surplus soil to a distance not exceeding 50m from the satrting point, watering pipe 20mm dia GI light grade treated with one No PGI funnel, pit of PCC (1:2:4) type B1chamber( using 20 mm gradedcrushed stone aggregate) RCC 1:2:4 type B1( using 20 mm gradedcrushed stone aggregate) pit cover 75 mm thick reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, complete connected to earth test point including testing complete all as secified and directed by Engineer-in-Charge.
S&F MCB DB SPN 12 Way with metal double door, (IP43 Protection) flush mounting epoxy powder control having 200 Amps rated bus bar complete all as specified and directed by Engr-in-Charge.
Sub main wire using FRLS insulated unsheathed mulitistrand copper conductor FR PVC cable 2 runs of size 10 Sqmm for phase and neutral and 6 Sqmm for earthing drawn through rigid PVC casing caping/PVC condute pipe not less than 25mm dia fixed on wall/ground/ceiling etc, and complete all as specified and directed by Engr-in-Charge. Note:- Phase should be Red/Yellow /Blue, neutral should be black and earthing wire should be green colour. Two run of cable for phase /neutral and one run of cable for earth incl casing caping / conduit pipe will be measured and paid as one unit length.
S&F sheet metal enclouser MCCB DB IP 20 double door bus bar neutral link earth bar and din rail VTPN 4 way complete all as specified and directed by Engr-in-Charge. Make : Cat Part No 607752 (DPX 63+12+12) of MDS Legrand or its equivalent as specified make.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicate dsituation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed by Engr-in-Charge.
S&F Metal clad plug and socket 20 Amps with MCB SP and steel enclosure complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised earth plate electrode 60 cmx 60 cmx 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of the plate not less than 1.5M below normal ground level connected to GI wire 4mm as earthing lead by means of nut,bolts and check nut and washer,GI light grade protection pipe 15 mm dia. upto 7.5 m,GI watering pipe 20 mm dia,RCC cover with funnel,excavation in any type of soil,PCC pit charcoal ,salt all as shown in electrical plate No 2 of SSR Part I, including earth test point up to pannel board, including testing on completion, complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable sub main wiring of any type and any size complete and making good disturbed surface complet all as specified and directed by Engr-in-Charge. Note:- The rate is inclusive cutting /chasing and making good the disturbed surface with cm 1:3 and same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash.
S&F in replacement for surface mounting tube light fitting, 1X20 watt, 230 volts 4 ft LED CRCA batten including retrofit T8 glass (LED tube rod) with and internally pre wired with all accessories and including connecting up to fitting, complete all as specified and directed by Engr-in-Charge. Make-C&S Cat Part No TARA-Mi/20 or equivlent in Havells/Philips/Benlo
S&F in replacement surface mounting tube light fitting, 1X10 watt, 230 volts 2 ft LED CRCA batten including retropit T8 glass (LED tube rod) with and internally pre wired with all accessories and including connecting up to fitting complete all as specified and directed by Engr-in-Charge. Make-C&S Cat Part No TARA-M/10 or equivlent in Havells/Philips/Benlo
S&F in replacement of building security light fitting 30W LED 5000K new Powder coated pressure die cast aluminium compact LED Street light suitable for and including pole dia 40 mm of bracket duly fixed with clamps, nut, bolts & washers etc complete all as specified and directed by Engr-in-Charge. (Make: C&S Model : INDUS E-SERIES or equivalent in specified make
S&F in replacement TPN DB 4 way double door type for fixing MCCB upto 100 amps as incomer and MCB as out going with metal door and IP 43 protetions & connecting complete all as specified and directed by Engr-in-Charge. Make:- Legrand/ABB/Crabtree.
S&F in replacement SPN DB 8 way double door type with metal door and IP 43 protetions flush mounting for MCBs & connecting complete all as specified and directed by Engr-in-Charge. Make- Legrand/ABB/Crabtree.
S&F in repair MCB DP 40 amps 'C' series, breaking capacity 10 Ka, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and directed by Engr-in-Charge.
S&F in repair MCB SP 5 to 32 amps 'C' series, breaking capacity 10 Ka, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 100 Amps 3 pole 415 volts fixed type with breaking capacity 36 KA 415 volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement concealed double door sheet metal enclosures with socket plug top and 20 amps MCBs for geyser complete all as specified and directed by Engr-in-Charge.
S&F in replacement of water heater storage type (Geyser) of capacity 50 ltrs, BEE 5 star, body of ABS plastic material, copper inner tank, auto cat adjustable temperature, safety valve, thermal cut out input voltage 230 volts, power consumption 2 kw including all fittings 4 sets of nut, bolts and washers of monimum dia 10 mm, grouting in wall, 2 No's PVC connection 45 cm long switable for hot/cold water and two No's brass CP 15 mm bore stop valve, 01 No's NRV, 01 PRV, 01 plug top 16 Ampr and making all electric and water connection. complete with heating element, thermostat,3 core lead, Plug top, safty valve, inluding electric and water connection and making good to disturbed surface complete all as specified and directed by Engr-in-Charge. Make : Cat Part No Monza of Havells or its equivalant as specified make. Note : Old Geyser to be deposited in MES store.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
verma enterprises
Vipul Construction
M/S.M.S.Devi.Const.Co
M/S CHANDER MUNI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .