| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1Accepted-AOC | ₹1 Quoted ₹8.52 | L1 | Accepted-AOC L1 |
| 2 | L2₹9.35+₹0.83 (9.74%)Rejected-Finance | ₹9.35+₹0.83 (9.74%) | L2 | Rejected-Finance REJECTED |
| 3 | L3₹985+₹976.48 (11461.0%)Rejected-Finance | ₹985+₹976.48 (11461.0%) | L3 | Rejected-Finance REJECTED |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | FLEXICARE MEDICAL (INDIA) PRIVATE LIMITED L3 | LIFE O LINE TECHNOLOGIST L1 | HUTCH SURGICAL L2 |
|---|---|---|---|---|---|---|
| 33.00 | Biopsy Gun, TRUS Biopsy Needle(Core Needle biopsy gun)- Tissue biopsy needle, 18 G , 20/25 cm, Biopsy needle/ 14G (10CM,16CM) / 16G (16CM) / 14G (10CM,16CM,20CM) | 4,000 | Each | - | - | - |
| 34.00 | Biopsy Gun, Kidney Biopsy Gun 10X16G | 3,000 | Each | - | - | - |
| 35.00 | Double Layered (3 ply) Washable Green Mask. | 1,00,000 | Each | - | - | - |
| 36.00 | Disposable dual heated neonatal and pediatric ventilator circuit: • The circuit should be compatible with Infant Ventilator with flow > 4 L/min as well as < 4 L/ min. • The circuit should be dual-heated. • The length of inspiratory limb should be at-least 1 m and should be supplied with 0.3 m incubator extension. • It should have an autofeedhumidifier chamber. • The expiratory tube should have heating element with-in the circuit in-order to avoid condensation or rain drop-out. • The length of expiratory limb should be at-least 1.5 m. • It should have humidifier connection tube with NO port, swivel wye-piece, pressure line, different adaptors for ventilators in use in various hospitals (Drager/Maquet& SLE ventilators). • Limbs shouldn’t made with natural rubber latex. • It should be disposable according to hospital protocol. | 1,200 | Each | - | - | - |
| 37.00 | SUCTION MACHINE & APPARATUS : Powder Coated Mild Steel Cabinet • Rotary Vane Type Pump with -710 ± 10 mm Hg • Noise level of suction apparatus is 50 dB ± 03 dB • 2 X 2.0 Ltrs. Glass jars with overflow safety device • Free air displacement 28 ~ 33 Ltrs • Electrical Requirement - 220~230VAC, 50Hz, 1Phase • Heavy duty HN-50 Castors • 1/2 H.P. Crompton motors. • 63 mm Vacuum Gauge • Non collapsible Suction Tubing | 600 | Each | - | - | - |
| 38.00 | High Flow Nasal Cannula–Newborn, Infant, & Paediatric: The cannula should be anatomically contoured to fit preterm, term neonates, infants and pediatric population. Nasal cannula diameter should be suitable to fit preterm, term neonates, infants and pediatric population to deliver wide range of flows to allow flexibility of treatments. Suitable for delivery of flows between 2-25 l/min. Made of soft material to minimize nasal trauma & should be made of free tubing’s materials e.g. latex free / thermoplastic elastomer (TPE) / Medical PVC. Should have adhesive that stick on skin to secure prongs. The material of adhesive tape should be suitable for use in preterm neonates (preferably hydrocolloid). Adhesive pads should be easily replaceable in case of long duration use. | 1,200 | Each | - | - | - |
| 39.00 | MICROPIPETTE , AUTOMATIC FIXED VOLUME DISPENSER OF DIFFERENT VOLUME WITH SPARE PARTS 10, 20, 50, 100, 200, 500, 1000 MICRO LITRE IS 4364, IS 5155 | 500 | Each | - | - | - |
| 40.00 | APD Cassette 4 Prong
Specification : Automated PD set W/4 Prong cassette ; 4 inlets ; 1 outlet; 1 patient connect more than 5ft tube; compatible with APD cycler | 3,24,000 | Each | - | - | - |
| 41.00 | CA 250 Line
Specification : CA 250 Line - Prismaflex Calcium line/ CA250 lines: Used with Regional Citrate Anticoagulation for compensating patients Calcium | 600 | Each | - | - | - |
| 42.00 | Manual PD Drain Bag 2 Lits
Specification : CAPD Sample disconnect set for 2 Its compatible PD bags compatible with patient used transfer set | 6,48,000 | Each | - | - | - |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
15 Oct 2025, 12:00 pmClosed
THE DY. DIRECTOR OF HEALTH SERVICES (E AND S)
Central Medical Stores 141, A J C Bose Road, Kolkata 700014
E-TENDER FOR PROCUREMENT OF SOME CONSUMABLE ITEMS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC)
2025_HFW_901360_2
WBHF/CMS/ HST/1P-151-2025/SCI/2025/360
Open Tender
Equipments
Item Wise
730 days
KOLKATA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1 L
Yes
18 May 2026
11 Sept 2025
15 Oct 2025
11 Sept 2025
15 Oct 2025
24 Sept 2025
Biopsy Gun, TRUS Biopsy Needle(Core Needle biopsy gun)- Tissue biopsy needle, 18 G , 20/25 cm, Biopsy needle/ 14G (10CM,16CM) / 16G (16CM) / 14G (10CM,16CM,20CM)
Biopsy Gun, Kidney Biopsy Gun 10X16G
Double Layered (3 ply) Washable Green Mask.
Disposable dual heated neonatal and pediatric ventilator circuit: • The circuit should be compatible with Infant Ventilator with flow > 4 L/min as well as < 4 L/ min. • The circuit should be dual-heated. • The length of inspiratory limb should be at-least 1 m and should be supplied with 0.3 m incubator extension. • It should have an autofeedhumidifier chamber. • The expiratory tube should have heating element with-in the circuit in-order to avoid condensation or rain drop-out. • The length of expiratory limb should be at-least 1.5 m. • It should have humidifier connection tube with NO port, swivel wye-piece, pressure line, different adaptors for ventilators in use in various hospitals (Drager/Maquet& SLE ventilators). • Limbs shouldn’t made with natural rubber latex. • It should be disposable according to hospital protocol.
SUCTION MACHINE & APPARATUS : Powder Coated Mild Steel Cabinet • Rotary Vane Type Pump with -710 ± 10 mm Hg • Noise level of suction apparatus is 50 dB ± 03 dB • 2 X 2.0 Ltrs. Glass jars with overflow safety device • Free air displacement 28 ~ 33 Ltrs • Electrical Requirement - 220~230VAC, 50Hz, 1Phase • Heavy duty HN-50 Castors • 1/2 H.P. Crompton motors. • 63 mm Vacuum Gauge • Non collapsible Suction Tubing
High Flow Nasal Cannula–Newborn, Infant, & Paediatric: The cannula should be anatomically contoured to fit preterm, term neonates, infants and pediatric population. Nasal cannula diameter should be suitable to fit preterm, term neonates, infants and pediatric population to deliver wide range of flows to allow flexibility of treatments. Suitable for delivery of flows between 2-25 l/min. Made of soft material to minimize nasal trauma & should be made of free tubing’s materials e.g. latex free / thermoplastic elastomer (TPE) / Medical PVC. Should have adhesive that stick on skin to secure prongs. The material of adhesive tape should be suitable for use in preterm neonates (preferably hydrocolloid). Adhesive pads should be easily replaceable in case of long duration use.
MICROPIPETTE , AUTOMATIC FIXED VOLUME DISPENSER OF DIFFERENT VOLUME WITH SPARE PARTS 10, 20, 50, 100, 200, 500, 1000 MICRO LITRE IS 4364, IS 5155
APD Cassette 4 Prong Specification : Automated PD set W/4 Prong cassette ; 4 inlets ; 1 outlet; 1 patient connect more than 5ft tube; compatible with APD cycler
CA 250 Line Specification : CA 250 Line - Prismaflex Calcium line/ CA250 lines: Used with Regional Citrate Anticoagulation for compensating patients Calcium
Manual PD Drain Bag 2 Lits Specification : CAPD Sample disconnect set for 2 Its compatible PD bags compatible with patient used transfer set
Oxiris Specification : Having three layers for removing Cytokines, Endotoxins and performing CRRT all together. AN69 layer removes Cytokines, PEI layers remove Endotoxins and a Heparin graft is present for maintaining thrombogenecity. Applicable for more than 30kg patient. Filter surface area 1.5m2. Extracorporeal Blood Bolume: 193ml. Specifically indicated for Sepsis+AKI
PD Drain Bag 15 Lts (In pairs) Specification : Cycler Drainage set / 15 its APD drain bag ; compatible with patient used 4 prong APD cassette
Peel apart Introducer for Tenckhoff catheter Specification : 16 Fr. Pull Apart sheath and dilator, introducer needle, guide wire all compatible with 31, 37 and 42 cm Tenckhoff PD catheter
Peritoneal Dialysis Catheter Set w/2 Cuffs 57 CM coiled Specification : Catheter 57cm straight with coiled tip; should come in a sterile pack, numerous inflow/outflow holes, made of translucent medical grade silicon rubber, radiopaque stripe, Beta-cap adapter, Beta-cap clamp, Two attached cuffs.
Peritoneal Dialysis Catheter Set w/2 Cuffs 62 CM coiled Specification : Catheter 63 cm straight with coiled tip; should come in a sterile pack, numerous inflow/outflow holes, made of translucent medical grade silicon rubber, radiopaque stripe, Beta-cap adapter, Beta-cap clamp, Two attached cuffs.
Prismaflex HF20 Specification : Filter having PAES Membrane for more bio compatibility, Applicable for 8-11kg patient. Filter surface area 0.2 m2. Extracorporeal Blood Volume: 58ml.
Prismaflex M60 Specification : Filter having AN69 Membrane , Applicable for 11-30kg patient. Filter surface area 0.6m2. Extracorporeal Blood Bolume: 93ml.
Prismaflex M100 Specification : Filter having AN69 Membrane , Applicable for more than 30kg patient. Filter surface area 0.9m2. Extracorporeal Blood Bolume: 152 ml.
Prismaflex M150 Specification : Filter having AN69 Membrane , Applicable for more than 30kg patient. Filter surface area 0.9m2. Extracorporeal Blood Bolume: 152 ml.
Quinton Catheter Accessories Specification : HD permanent single cuff staggered tip catheter double lumen straight 14.5 Fr (tip to cuff 19cm, right side); Catheter should come in a kit with carbothane/Silicon Catheter, introducer needle, guide wire, syringe, dilator, island dressings, sealing caps and 16 Fr. Pull Apart sheath and Tunneling stylet.Flow Rate min 450 ml/min. Catheter should be US/FDA Approved.
Soft Tenckhoff PD Catheter 37 cm Straight double cuff. Specification : Catheter 36cm straight ; should come in a sterile pack, numerous inflow/outflow holes, made of translucent medical grade silicon rubber, radiopaque stripe, Beta-cap adapter, Beta-cap clamp, Two attached cuffs.
Soft Tenckhoff PD Catheter 42 cm Straight double cuff. Specification : Catheter 42-43cm straight ; should come in a sterile pack, numerous inflow/outflow holes, made of translucent medical grade silicon rubber, radiopaque stripe, Beta-cap adapter, Beta-cap clamp, Two attached cuffs.
Stiff PD catheter (Paediatric) Specification : Stiff Tenckhoff-type catheter for peritoneal dialysis (PD), suitable for surgical, laparoscopic, or percutaneous insertion. Designed for optimal inflow/outflow, with biocompatible materials for temporary or permanent access. Material (• Medical-grade biocompatible silicone • Non-toxic, non-pyrogenic, latex-free, DEHP-free •Radiopaque for X-ray visibility)• Straight or curved configuration with double Dacron cuffs • Multiple side holes near tip for optimal dialysate flow • Includes removable/fixed stiffening wire or stylet. Outer Diameter (OD)-3.5–4.5 mm (10–12 Fr).Length - 30–36 cm. Cuff Position- Proximal: 1–2 cm from exit , Distal: 6–8 cm from tip.Two (double cuffed), Straight (preferred). Accessories(• Stylet or stiffening wire • Tunneler • Trocar (if applicable) • Transfer set connector/adaptor • End cap • Sterile pack with user manual)• ETO sterilized or equivalent • Shelf life: Minimum 3 years • SAL: 10⁻⁶. • CE marked / US FDA / CDSCO approved • Manufacturer must be ISO 13485 certified.• Individually sterile-packed • Label must include product code, size, expiry, batch number, manufacturer, sterilization method.• Supplier to provide user training/demo if needed • Certificate of Analysis (CoA) and sterility certificate with each batch • Warranty against manufacturing defects
Stiff PD catheter (Adult) Specification : Stiff Tenckhoff-type catheter for peritoneal dialysis (PD), suitable for surgical, laparoscopic, or percutaneous insertion. Designed for optimal inflow/outflow, with biocompatible materials for temporary or permanent access. Material (• Medical-grade biocompatible silicone • Non-toxic, non-pyrogenic, latex-free, DEHP-free •Radiopaque for X-ray visibility)• Straight or curved configuration with double Dacron cuffs • Multiple side holes near tip for optimal dialysate flow • Includes removable/fixed stiffening wire or stylet. Outer Diameter (OD)-4.5–5.5 mm (14–16 Fr).Length - 42–48 cm. Cuff Position- Proximal: 1–2 cm from exit ,Distal: 8–10 cm from tip. Two (double cuffed), Straight or Curved. Accessories(• Stylet or stiffening wire • Tunneler • Trocar (if applicable) • Transfer set connector/adaptor • End cap • Sterile pack with user manual)• ETO sterilized or equivalent • Shelf life: Minimum 3 years • SAL: 10⁻⁶. • CE marked / US FDA / CDSCO approved • Manufacturer must be ISO 13485 certified.• Individually sterile-packed • Label must include product code, size, expiry, batch number, manufacturer, sterilization method.• Supplier to provide user training/demo if needed • Certificate of Analysis (CoA) and sterility certificate with each batch • Warranty against manufacturing defects
Urine Collecting Bag, Disposable, 2000 ml, Kink resistant flexible tubing not less than 90 cm in length, should have non-return valve, Top drainage outlet, Graduated Bag
ENDOTRACHEAL TUBE, Double Lumen Endotracheal Tube: 1. Sizes: Left & right (assorted)2. Soft round Bever tip to minimize trauma to patients. 3. Should contain intubation stylet and super slip suction catheter.
ECG PAPER ROLL FOR TWELVE (12) CHANNEL ECG MACHINE. Size- 210 mm X 20mtr.
Oxygen delivery musk : 1. Vinyl soft mask with shouldered crush resistant 2mtr, 2. oxygen tubing
Oxygen Mask, vinyl o2 mask with pre mounted star lumen crush o2 tubing
CVC 3 Fr. with Anti Kinking Nitnol Guide Wire (Paediatric)- 6CM/10CM * 3Fr. Thermosensitive Polyurethane Double Lumen Paediatric CVC. * It has Anti Kinking Nitnol Guide Wire
DISPOSABLE NEEDLES 23G
DISPOSABLE NEEDLES 24G
DISPOSABLE NEEDLES 26G
Capillary tubes Specifications: 1. The Capillary tubes should be specifically designed for use with Siemens Epoc Blood Gas Analyzers. 2.The tubes should be compatible with Siemens Epoc Blood Gas Analyzers. 2. The tubes should be designed for collection, transportation and dispensing of samples for blood gas analysis. 3. The tubes should contain a suitable anticoagulant (e.g., Calcium balanced heparin) to prevent clotting and ensure accurate test results. 4. The tubes should be made of a durable, non-reactive material that minimizes the risk of sample contamination. 5. The tubes should have clear labeling and instructions for use.
Important Note: 1. All prospective bidders are requested to quote the rate in BOQ AS PER ACCOUNTING UNIT (AU) REPEAT AS PER ACCOUNTING UNIT (AU) & item specifications as mentioned in the Table-1. WRONG QUOTING OF THE RATE in BOQ will be dealt with as per penal provisions of the T&C of the Tender. 2. Quality of the product supplied, may be ascertained by testing / physical examination by the experts at any stage of the tender period. 3. The equipment should be US FDA/ CE/ BIS/ CDSCO approved (US FDA/ CE requirements will be applicable only when the Indian Standards like BIS/ CDSCO is not available). 4. The prospective Bidders of the said Tender are requested to make a declaration in Affidavit under Annexure VI(b) in case of sole manufacturer/importer (i.e. proprietary in nature). 5. If the Item(s) under sole manufacturer / importer is (are) Proprietary in nature, quarterly intimation is solicited from the approved Bidders positively regarding the status of their Item(s) Proprietary in nature, otherwise their Item(s) will be blocked in the SMIS. 6. In case of Tie Bid, decision will be taken by the TIA as per G.O. No. 2320-F(Y), dated 07.06.2022 issued from Finance Department Audit Branch (Group T).
HUTCH SURGICAL (BID ID -7073584)
FLEXICARE MEDICAL (INDIA) PRIVATE LIMITED (BID ID -7064713)
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.95 MB
Technical_Data_Sheet_360.xls
Tender Documents • 2.77 MB
BOQ_2037274.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .