Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC NO 5 MOOGAMBIGAI NAGAR MANOJIPATTI ROAD M C POST THANJAVUR 613004 | THANJAVUR | TAMIL NADU | 613004 | L1 | Accepted-AOC Lowest bidder accepted. | |
| 2 | L2₹38.1 L+₹1.1 L (3.04%)Rejected-AOC | L2 | Rejected-AOC Other than the Lowest bidder not accepted. | |
| 3 | L3₹38.2 L+₹1.2 L (3.23%)Rejected-AOC | L3 | Rejected-AOC Other than the Lowest bidder not accepted. |
Tender Value
Refer Docs
EMD Value
₹37,000
Closing Date
9 Jul 2024, 3:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer, Planning and Designs Circle, Chennai - 5.
Provision of Internal and external Lighting with strengthening of exisiting power mains arrangements in the SAMBHAJI RAJAH BHONSLE QUARTERS, Heritage Building in Thanjavur Palace at Thanjavur District.
2024_PWD_456960_1
03/PAD/2024-25
Open Tender
Electrical Works
Lump-sum
60 days
Thanjavur
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹37,000
Yes
16 Dec 2024
24 Jun 2024
10 Jul 2024
24 Jun 2024
9 Jul 2024
24 Jun 2024
Amount
Rewiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling and switch drop portion PVC rigid pipe concealed in wall with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of Suitable colour for PVC Light point / fan point (for electronic regulator) ( 4 points / Coil) Higher End. (SD 327)
Rewiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling and switch drop portion PVC rigid pipe concealed in wall with PVC accessories with Module GI switch box in flush wall with 6A one way module switch with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) ( 5 points / Coil) Higher End. (SD 329)
Renewal by Supply and fixing of bakelite battern holder with 9 W LED lamp for BH point.(DATA-A)
Renewal by Supply and fixing of single box type 4’20W LED fitting with TW round blocks on wall/ceiling with 4’20W LED tubewith PVC unsheathed Copper leads from terminals to the fitting (Higher end).(DATA-B)
Renewal by Supply and fixing of 1x1 30 W LED recessed type mounting fitting (Havells / equilvalent ) complete with LED Driver with PVC unsheathed Copper leads from the terminals to the fittings (Make: Philips /Havells /Crompton / equivalent).(DATA-C)
Renewal by supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18")(SD 549)
Renewal by supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .(SD 535)
Renewal by Supply and fixing of 3nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End (SD 476)
Renewal by Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End (SD 488)
Renewal bySupply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.(SD-427)
Renewal by Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour. (SD 429)
Renewal by Supply and Run of 4 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour. (SD 439)
Renewal by Supply and Run of 4 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigd pipe on wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour. (SD 441)
Renewal by Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End. (SD 605)
Renewal by Supply and fixing of 63A TPN MC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only.(SD-166)
Renewal by Supply and fixing of Vertical type 4 way triple pole neutral MCB distribution board in sheet steel enclosure double door metal cover with IP 42 protection with 63A 4 pole MCB Isolator as incoming 6 Nos. 6 A to 32 A SP MCB , 2 nos 32 TP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB’s should be with the ISI mark (like Legrand(MDS)/Hager(L&T) make) (DATA-D)
Renewal by Supply, erection, testing and commissioning of 2.0 TR (6000 K. cal/ hr) ABS plastic split type Air conditioner conforming to IS: 1391 (Part-2) 1992 with Rotary compressor operating on Non- CFC refrigerant suitable for wall mounting for operation on 230V, 50 HZ single phase AC supply with Three Star rating as per BEE specification and capable of performing the functions of (I) Cooling (II) Dehumidifying. (III) Air circulating. (IV) Filtering.
The installation works for the split type AC unit includes the following 1. Mounting/fixing indoor and outdoor units at the respective locations. 2. Laying refrigerant pipe line of required length not exceeding 6 mtrs distances and connecting both units after drilling holes in the wall if required. Thickness of the copper tube shall not be less than 0.7 mm. 3. Insulating the section pipe with expanded Polyethylene frame 5 mm tubing. 4. Laying 15 mm dia flexible PVC drain pipe to condemn ate water being formed with in the indoor unit. 5. Leakage testing the entire system. 6. Charging refrigerant gas in the unit. 7. Suitable electrical wiring to be provided with 2.5 Sq.m.m PVC Insulated copper wire between indoor & outdoor unit type 6 mtr. Length and upto switch with in the 3 mtrs of location of indoor unit. (Blue Star,Carrier,Voltas) (3 star Rated) (SR)
Renewal by Supply and fixing of 5 KVA Electronic automatic Voltage stabilizer ‘ V ’ Guard make VGS 500 ( or ) Equivalent with input range of 170V to 270V and output range of 200V – 240V unit with and low voltage cut off and 3Mintes time delay with demonstrations decorations complete.(SR )
Renewal by Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection completet .(SD-129)
Renewal by Supply and fixing of 3 phase 63A aerial fuse unit for 3 Nos. 63A fuse units (500V) on suitable MS sheet covered with 6mm thick hylem sheet on suitable angle iron work the tapping pole with necessary clamps.(DATA-E)
Renewal by Earthing as per P.W.D standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work.(SD-234)
Renewal by Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection(SD-458)
Renewal by Supply and fixing of 30 W LED Flood light with integrated driver with necessary connection (DATA-F)
Supply and erection, testing, commissioning uninterrupted power supply OFFLINE (Sinewave) with copper wound Transformer of 1100VA with Input supply of 230V, 50Hz AC supply with 150 AH Tubular Battery to work at full load capacity for 2 Hours back up including transportation with following specification. 1) Input Voltage : 230, 50Hz single phase AC supply 2) Output Voltage : 220V to 240V 50HZ AC supply 3) Battery charging device of suitable rating 4) Circuit board of suitable capacity 5) Over load and short circuit protection 6) Visual Indication for ON/OFF / Trip / battery charging/mains failure/ Low Battery etc., 7) Mode setting for Bypass/Reset 8) 12V 150AH battery - 1 No. 9) Trolly for heavy UPS & Battery(Make : Exide / Microteck/Amron/Equivalent)(SoR 23-24/M-2100)
Renewal by Supply and clamping of 3½ X 25 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.(SD-222)
Renewal by Supply and laying 3½ X 25 sq.mm PVC Armoured LTUG Cable a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.(SD-204)
Renewal by Supply and fixing of brass cable gland for 3½ X 25 sq.mm PVC Armoured LTUG Cable with earth connection.(SD-186)
Renewal by Supply and providing cable end termination of 3½ X 25 sq.mm PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.(SD-235)
Renewal by Supply and fixing of 1No.MS pillar box of size 3”x3”x2” (HxWxD) made up of 16SWG MS sheet for outer body and mains chamber with angle iron frame work of size 11/2”x11/2”x1/4” for outer frames and intermediate supports for mains chamber and fuse unit sets and bottom supports. The pillar box should be mounted on suitable foundation concrete on ground with one coat of red oxide and two coats of synthetic enamel paint with lock and key arrangements and DANGER board and necessary superscriptions complete housing service mains. .(EER.TVR.No.291/22-23)
Supply and fixing of 20A DP plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug)(SD 140)
Renewal by Supply and fixing of special type wall bracket with warm white LED Bulb brass coated antique design suitable for the existing wall décor enhancing the ambience (DATA-G)
Renewal by Supply and fixing of special type ornamental pole of 5 ft height with LED light brass coated antique design suitable for the existing wall décor enhancing the ambience (DATA-H)
Renewal by Supply and clamping of 4X 16 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.(SD-203)
U.S. ELECTRICALS (BID ID -1077876)
KARTHIKEYAN ELECTRICALS (BID ID -1077945)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_543381.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .