Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹32.2 LAccepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹39.3 L+₹3.9 L (11.2%)Rejected-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹42.6 L+₹7.3 L (20.6%)Rejected-AOC | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹43.2 L+₹7.8 L (22.2%)Rejected-AOC | L-4 | Rejected-AOC L-4 | |
| 5 | Rejected-Technical 6 341 RATAN VIHAR NANGLOI DELHI 110041 | DELHI | WEST DELHI | DELHI | 110041 | - | Rejected-Technical No, not enlisted in eligible category. |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
17 Dec 2022, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINT OF CERTAIN E/M FIXTURE/FITTINGS, CEILING FAN, EXHAUST FAN, GEYSER, STREET/BUILDING SECURITY LIGHT AND OTHER CONNECTED WORKS AT DIPAS, DIPR, CFEES, RAC LAB INCLUDING ZONE B AREA UNDER GE I RnD DELHI
2022_MES_563773_1
GE/RND-83/DLI/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class-D, Cat-b(i), b(ii)
2 documents required · 2 mandatory
₹500
Yes
GE I RND DELHI
₹1 L
Yes
18 Jan 2023
17 Nov 2022
19 Dec 2022
17 Nov 2022
17 Dec 2022
5 Dec 2022
Amount
Taking down ceiling fan carefully and depositing in MES E/M store yard for greasing, oiling, minor repairs i.e. bush, capacitor, rubber reel, bearings etc and painting with synthetic enamel white paint using spraying machine and providing the MES No to fan using black paint refixing the same and testing complete all as specified and directed.
S&F in replacement sheet metal enclosure with socket plug top and MCBs single pole and neutral enclosure with 2 pin and earth plug and socket with one single pole MCB 32 Amps complete all as specified and directed.
S&F in replacement Bell Ding Dong type AC 230 Volts single Pole complete all as specified and directed.
Taking down of exhaust fans of any type/ size and connecting up of cable from ceilling rose to connector of fan for painting or servicing or rewinding of fans and refixing the same complete all as specified and directed. Note:- Rewinding, servicing & painting etc required shall be measured seperately under respective item of BOQ.
All as per item Ser No 4.00 above but wall mounted fans.
M&L for painting of exhaust fans of any type/size including motor blade cover bracket /arms with synthetic enamel paint by spary painting, filling cavities with filler, one coat after celaning all dust etc.and writing MES No with black synthetic enamel paint complete all as specified and directed.
M&L for servicing of exhaust fans of any type/size cleaning the dust, oiling, greasing, replacing unserviceable bearing, split pin etc complete all as specified and directed. Note :- Bearing, split pin etc (minor parts) are deemed in a quoted rate.
M&L for rewinding of exhaust fans by removing burnt out windning wire without damaging the rotar, cleaning the slots and rewinding with appropriate gauge super enameled copper wire, putting wedges with polythene paper, varnishing, heating, greasing and testing complete all as specified and directed.
All as per item ser No 8.00 above but wall mounted fans of any size.
S&F in replacement lamp holder angle /batten type PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F in replacement LED 10 Watt fitting with Decorative ultra slim square profle LED lighting fixture with extruded polycarbonate, environmental friendly, energy effcient with aluminium housing & integral electronic driver with LED tube 10 watt including connection with 1.5 Sqmm 2 core flexible copper conductor cable complete all as specified and directed.
S&F in replacement LED 6 watt surface mounted downlight with white powder coated polycarbonate housing and pressure die cast heat sink having high efficiency including connection with 1.5 Sqmm 2 core flexible copper conductor cable complete all as specified and directed.
S&F in replacement LED 12 watt surface mounted downlight with white powder coated polycarbonate housing and pressure die cast heat sink having high efficiency including connection with 1.5 Sqmm 2 core flexible copper conductor cable complete all as specified and as directed.
S&F in replacement LED 20 Watt fitting with Decorative ultra slim square profle LED lighting fixture with extruded polycarbonate, environmental friendly, energy effcient complete with aluminium housing & integral electronic driver including connection with 1.5 Sqmm 2 core flexible copper conductor cable complete all as specified and directed.
S&F in replacement LED 18/16 Watt fitting with decorative end cap complete with aluminium housing & integral electronic driver with LED tube 18 watt complete including connection with 1.5 Sqmm 2 core flexible copper conductor cable complete all as specified and directed.
S&F in replacement LED 36 watt surface mounted 600x600x70mm (2'x2') with soft light and glare free symmetrical illumination having high efficiency including connection with 1.5 Sqmm 2 core flexible copper conductor cable complete all as specified and directed.
S&F in replacement LED 36 watt recessed mounted 600x600x70mm (2'x2') with soft light and glare free symmetrical illumination having high efficiency including connection with 1.5 Sqmm 2 core flexible copper conductor cable complete all as specified and directed.
S&F in replacement ARD Battery for lifts 12 Volts 7 AH complete all as specified and directed.
S&F in replacement ARD batteries 18 AH 12 volt for lift complete all as specified and directed.
S&F in replacement of lead acid battery 12 volt 180 AH for DG set complete all as specified and directed.
S&F in replacement of ACB 4 pole, 415 V, breaking capacity 50 KA with thermal magnetic release (Manual fixed type) of capacity 630 Amps complete all as specified and directed.
S&F in replacement of ACB 4 pole, breaking capacity 50 KA manual draw out (MDO) with microprocessor based lcd protection release 415 volt 50 Hz Thermal magnetic release (Manual fixed type) of capacity 800 Amps complete all as specified and directed.
All as per item Ser No 22.00 above but 1250 Amps capacity.
All as per item Ser No 22.00 above but 1600 Amps capacity.
S&F in replacement of RMU protection relay model No- CSDPR-V2 type CSDR-V2-300-D-L-P, Frequence-50Hz, UN-in-1A, UV-18-60 volt DC and control rating-5A @ 220 volt AC and making as per existing make (C&S) with all connected accessories & testing complete all as specified and directed.
S&F in replacement of heating element 1.5 KW for 25 Ltr water heater complete including connection complete all as specified and directed.
S&F in replacement inlet/outlet assembly to match the existing 25/50 Ltr capacity geyser including fixing and testing complete all as specified and directed.
S&F in repalcement thermostat switch for 25/50 Ltr geyser including LED indicator lamp complete all as specified and directed.
S&F in replacement of heating element 2 KW for 25 Ltr water heater complete including connection complete all as specified and directed.
S&F in replacement of PVC connection pipe 15 mm bore 600 mm long with brass nut and rubber washer suitable for hot/cold water complete all as specified and directed.
M&L in replacement for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25X4 mm by means of nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified shown in electrical plate No 3 of SSR Part-I & testing on completion of the following:- (a) GI strip of size 25 mm x 4 mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick reinforced with 8 mm dia TMT bars 75 mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover. (e ) Apply two coat of syntheticnenamel paint over one coat of red oxide primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces.
M&L Galvanised iron strip 25x4mm buried in ground complete all as specified and directed.
M&L in replacement for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25 meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron wire 4 mm dia by means of Copper nuts, bolts and washers. GI wire shall be laid in 15 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified shown in electrical plate No 3 of SSR Part-I & testing on completion of the following:- (a) GI wire of size 4 mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick reinforced with 8 mm dia TMT bars 75 mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover. (e ) Apply two coat of syntheticnenamel paint over one coat of red oxide primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces.
S&F GI Wire 4mm dia for connecting earthing complete all as specified and directed.
S&F LED post top lantern 20 luminaire with diffuser and painted spun aluminium deflector including taking down old unserviceable lantern complete all as specified and directed.
S&F in replacement LED bollard light 9 watts IP-65 and diffuser at the upper porton1 metre height and connected with all accessories complete all as specified an directed.
S&F in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm, 3.5 core complete all as specified an directed.
All as per item Ser No 37.00 above but 150 Sqmm 3.5 core.
All as per item Ser No 37.00 above but 120 Sqmm 3.5 core.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping and around pole including demolition of old PCC complete all as specified and directed.
S&F in replacement lift car fan as per OEM make with complete accessories complete all as specified and directed.
S&F in replacement lift siren as per OEM make with complete accessories complete all as specified and directed.
S&F in replacement LOP ( Lift operating panel) as per OEM make with complete accessories complete all as specified and directed.
S&F in replacement of LOP up down button for lift as per OEM with accessories complete all as specified and directed.
S&F in replacement LED lift light as per OEM with accessories complete all as specified and directed.
M&L for disconnecting of unserviceable 400 to 750 KVA transformer from power mains and dismantling the same from platform mounted sub station by crane including HT and LT side cables and transporting the same to work shop and opening the transformer cover draining out of transformer oil, removing of the burnt part ie tape paper insulating strings etc gently and carefully washing of the dust, rust and dirt from all parts including taking out cooling tubes welding and re-assembling after carrying out required repair and transporting back to site and installed on existing platform with necessary fixing arrengement including connecting up electrically, commissioning and testing complete all as specified and directed.
Note: (i) The contractor shall produce test certificate as per IS-2026 along with high voltage test from the firms after repair. (ii) To certain the fault of transformer at installed location the transformer will be tested with HT 10 KV megger, multimeter in the presence of AGE E/M. All T&P required like HT megger 10 KV , multimeter and cables will be arrenged by contractor. (iii) All the transformer shall be opened in presence of Engr-in-Charge and the various repairs/replacement involved and the transformer shall be assembled in the presence of Engr-in-Charge after necessary repair/replacement. (iv) All the transformer shall be tested in the factory/workshop in the presence of Engr-in Charge and also in addition the transformer where specified to be installed and commissioned on the platform and also shall be tested by the contractor in the presence of Engr-in-Charge. (v) All the testing arrangement shall be provided by the contractor without any extra payment. (vi) The contractor shall also furnished a guarantee certificate himself for rectification of the defects. If any noticed defect during liability period for 1 year from the certified date of completion. (vii) The above shall however does not absolve the responsibility of the contractor for rectification of any defect, if any noticed during gurantee period of 01 year as per condition 46 of IAFW-2249 and the contractor shall be solely responsible for entire completion of work and for rectification of the defect/replacement of items/parts and required pointed out by the GE during defect liability perod. Payment only for dehydration of the transformer oil and painting of the transformers replacement of certain items considered separetly here in- after shall only be made for separately all other minor repair/replacement as required and ordered by Engr-in-Charge .
(viii) The contractor shall also clear the breathers. The unit rate quoted by the contractor shall included this aspect also. (ix) Contractor shall provided all arrengament for carefully handling/conveyance of transportation of equipment by means of crane/chain pully/recovery van and vehicle as per requirements and directed by Engr-in-Charge. (x) Transformer oil tank rubberised 6 mm thick gasket sheet pasted using gasket cement, oil level gauge, drain valve, painting inner side tank by zinc chromate paint and side by appoved include in this item rate. (xi) The rate quoted by contractor shall include all these aspect from (i) to (x) while quoting his tender that quoted rate also include the provision of providing electric connection to existing system.
Dismantling and segregation of HT/LT leg coil from transformer and making new HT/LT leg coil with insulating copper wire of existing gauge, craft paper, cotton tape HT/LT insulation as per specification of old transformer including ovening & heating after marking of coil as per required of following capacities :-
HT leg Coil copper.
LT leg coil copper.
Disconnecting HT/LT connection of any type transformer capacity, opening of transformer cover at site for carrying out testing/repair such as replacement of internal/external damage parts and re-assembling after carrying out required repair in the transformer and testing complete all as specified and directed. Note: Parts replaced of transformer shall be measured and paid separetly under respective items.
M&L for shifting of transformer of capacity 400 to 750 KVA from existing PCC platform and fixing on platform by suitable cap of crane including necessary connection on HT & LT side and testing on completion complete all as specified and directed.
M&L in repair HT bushing for 400 to 750 KVA transformer complete with metal part gasket set, nuts, bolt and washers for any type of transformer at site/workshop complete all as specified and directed.
M&L in repair LT bushing for 400 to 750 KVA transformer complete with metal part gasket set, nuts, bolt and washers for any type of transformer at site/workshop complete all as specified and directed.
M&L in repair HT bushing rod (brass) for 400 to 750 KVA transformer complete with nuts, bolt and washers for any type of transformer at site/workshop complete all as specified and directed.
M&L in replacement LT bushing rod (brass) complete with nuts, bolt and washers for any type of transformer at site/workshop for 400 to 750 KVA transformer complete all as specified and directed.
M&L in replacement tap changer switch complete with rod and gasket for 400 to 750 KVA transformer complete all as specified and directed.
M&L in replacement oil drain valve for 400 to 750 KVA transformer complete all as specified and directed.
M&L in replacement de-hydrating breather with first fill of de-hydrating agent(silica gel) for 400 to 750 KVA transformer complete all as specified and directed.
S&F in replacement 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celcius with metal guard having maximum perimeter temperature reading indicator with re-setting device complete all as specified and directed.
S&F in replacement rubberized gasket sheet for oil tank in the tank top cover 6 mm thick and pasted using gasket cement including fixing the top cover with conservator in the 400 to 750 KVA transformer capacity complete all as specified and directed.
S&Fin replacement rubberized gasket 6mm thick duly cut as per the size of bushing and pasted with gasket cement including cleaning and removing of carbon from HT/LT bushing, replacement of rubber oil seals assembling the LT/HT bushing and fixing connection with terminals as directed for 400 to 750 KVA transformer complete all as specified and directed.
M&L in replacement oil level indicator glass for any capacity of transformer complete all as specified and directed.
M&L in replacement Arc flash electrical suit kit 11 kv of all sizes with tools viz ( trouser, jacket, with hood glooves, belt , spiner kit) complete all as specified and directed.
M&L in repair cooling pipe of transformer of any capacity at site for rectification of leakage including welding/brazing etc complete all as specified and directed.
M&L for dismantiling of transformers indoor/outdoor type complete opening top cover by unscrewing nuts, bolts, unserviceable HT/LT coil of transformer, gaskets, bushing core tap changer, draning out transformer oil and keeping safely for reuse after filtration, cleaning the inner body with caustic soda/ detergent and washing to remove sludge etc, painting the outer side tank by zinc chromate paint and preparing the same for re-assembling for 400 to 750 KVA transformer complete all as specified and directed.
S&F in repair copper strip size 20 to 25 cm long on LT side of transformer at site duly drilled holes for transformer studs & LT cable fixed with GI bolts, nuts, washers of appropriate size for 400 to 750 KVA transformer complete all as specified and directed.
S&F aluminium lugs for HT bushing for 400 to 750 KVA transformer of suitable size by means of using crimping tool after removing existing unserviceable lugs complete all as specified and directed.
S&F aluminium lugs for LT bushing for 400 to 750 KVA transformer of suitable size by means of using crimping tool after removing existing unserviceable lugs complete all as specified and directed.
Supply and topping up transformer oil having dielectric strength not less than 45 KA complete all as specified and directed.
M&L for Servicing of VRF inverter split type 3 phase AC of capacity 14 TR. of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note:- (i) Any unserviceable items need to be replaced/gas charging etc shall be measured & paid separately under respective items.
M&L for Servicing of VRF inverter /ductable split type 3 phase ac of capacity 8 TR. of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note:- (i) Any unserviceable items need to be replaced/gas charging etc shall be measured & paid separately under respective items.
M&L for Servicing of casette/inverter/ductable/ non inverter type three/ single phase AC of cap 5.5 / 4.1/.3 TR. of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note:- (i) Any unserviceable items need to be replaced/gas charging etc shall be measured & paid separately under respective items.
M&L for Servicing of the window AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note:- (i) Any unserviceable items need to be replaced/gas charging etc shall be replaced & paid seperately under respective items. (ii) The cost of dismantling, taking out window AC 1.5/2.0 ton from window and shifting to location where directed for proper washing and servicing and refixing the same shall be deemed to be included in item quoted rate.
All as per item Ser No 71.00 above but for split type AC/Inverter type AC 1.5/2 TR capacity.
M&L in replacement Fan Motor of AC (Window/ Split Type) 1.5 TR Capacity of approved Make and required Size to suit existing AC including taking out the unserviceable Fan Motor from the AC complete all as specified and directed.
All as per Item Ser No. 73.00 above but AC (Window/Split Type). 2/3 TR Capacity
M&L Rewinding Fan Motor of AC 1.5 to 3.0 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including taking out burnt winding complete all as specified and directed.
M&L in replacement Air circular Blower Fan Motor of AC (Split/ cassette type), 1.5 to 3.0 TR Capacity including taking out unserviceable Air circular Blower Fan Motor complete all as specified and directed.
M&L in replacement Air Filter suitable of AC (Window type) 1.5 to 3.0 TR Capacity including taking out unserviceable Air Filter from AC complete all as specified and directed.
M&L in replacement Air Filter suitable of AC (Split/cassette type) 1.5 to 3.0 TR Capacity including taking out unserviceable Air Filter complete all as specified and directed.
M&L in replacement Capacitor Running 36 mfd – 45 mfd suitable for AC (Window/Split /cassette type) 1.5 to 3.0 TR Capacity and of any make including taking out unserviceable Capacitor from AC complete all as specified and directed.
M&L in replacement Capacitor Starting 80 mfd – 120 mfd suitable for AC (Window/Split/cassette type) 1.5 to 3.0 TR Capacity and of any make including taking out unserviceable Capacitor from AC complete all as specified and directed.
M&L in replacement Fan Motor Blades AC (Window/Split/cassette type) 1.50 to 3.0 TR capacity including taking out unserviceable Blades of Fan Motor from AC complete all as specified and directed.
M&L in replacement Fan Motor Capacitor 4 mfd of suitable for AC (Window/Split /cassette type) 1.5 to 3.0 TR capacity including taking our unserviceable Fan motor capacitor from AC complete all as specified and directed.
M&L Fan Motor in replacement Capacitor 6 mfd suitable for AC (Window/Split/ cassette type) 1.5 to 3.0 TR capacity including taking our unserviceable Fan motor capacitor from AC complete all as specified and directed.
M&L in replacement Front Plastic Grill (as per Sample) of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC complete all as specified and directed.
M&L in replacement Front Plastic Grill for inner unit (as per Sample) of AC (Split type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC complete all as specified and directed.
M&L in replacement Runner for air blower motor of AC (split/cassette type) AC 1.5 to 3.0 TR capacity (As per sample or as per site requirement) including Runner of Air Blower Motor from AC complete all as specified and directed.
M&L in replacement Starting Relay of AC (Window/Split/cassette type) 1.5 to 3.0 TR capacity including taking out unserviceable Starting Relay from AC complete all as specified and directed.
M&L in replacement Strainer with Capillary Tube of AC Window/ Split/cassette type) 1.5 to 3.0 TR Capacity including taking out unserviceable Strainer with Capillary Tube from AC complete all as specified and directed.
M&L in replacement Thermostat Switch of AC (Window/Split/cassette type) 1.5 /2/3 TR Capacity including taking out unserviceable Thermostat Switch from AC complete all as specified and directed.
S&F in replacement cooling coil suitable for window type room AC 1.5/2 ton including taking out unserviceable cooling coil complete all as specified and directed.
S&F in replacement Condensing coil suitable for window type AC 1.5/2 ton including taking out unserviceable Condensing coil complete all as specified and directed.
S&F in replacement Condensing coil suitable for split type AC of 2 ton capacity including taking out unserviceable Condensing coil complete all as specified and directed.
S&F in replacement cooling coil suitable for split type AC of 2 ton capacity including taking out unserviceable cooling coil complete all as specified and directed.
S&F in replacement Indoor unit suitable for 1.5 TR split type AC including taking out unserviceable Indoor unit complete all as specified and directed.
S&F in replacement outdoor unit suitable for 1.5 TR split type AC with compressor including taking out unserviceable outdoor unit complete all as specified and directed.
S&F in replacement Indoor unit suitable for up to 2 TR split type AC including taking out unserviceable Indoor unit complete all as specified and directed.
S&F in replacement outdoor unit suitable for up to 2 TR split type AC with compressor including taking out unserviceable outdoor unit complete all as specified and directed.
S&F in replacement of Hermitacally sealed compressor for split/ window type AC capacity 1.5 Ton complete all as specified and directed.
All as per item Ser No. 100.00 above but for capacity 2.0 Ton.
All as per item Ser No. 100.00 above but for 5.5/8.5 TR ductable AC.
Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt compressor Sealed Unit and providing new Compressor Rotary/ Reciprocating as per site requirment of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 including re-connection of Electric Connections, functioning AC complete in all respect and Testing, complete all as specified and directed. Note:- Compressor shall be procured from authorised dealer and submit purchase vouchers alongwith written guarantee/warantee as per manufacturer.
All as per Item Ser No. 103.00 above but AC 2.TR Capacity (Window/Split type)
M&L in replacement PCB with remote for window type AC up to 2 Ton capacity including taking out unserviceable PCB complete all as specified and directed.
M&L in repair of PCB with remote for Split type AC 2 to 3 Ton capacity including taking out unserviceable PCB complete all as specified and directed.
M&L in replacement PCB & motherboard with remote complete set for Inverter Split type AC up to 2 Ton capacity including taking out unserviceable PCB and mother board complete all as specified and directed .
Supply only in replacement Remote of AC ( Window/Split Type) 1.5/2.0 TR capacity (As per sample or as per site requirement) complete all as specified and directed.
S&F in replacement wiring kit suitable for 1.5 to 2.0 ton capacity AC complete including taking out unserviceable wiring kit complete all as specified and directed.
S&F in replacement gas charging pin valve complete including taking out unserviceable pin valve complete all as specified and directed.
Taking out window type AC complete unit from any height/ any floor (up to four storey building) and shifting to another location in the same or other building in the complex including refixing of the unit complete all as specified and directed.
Taking out split type AC complete indoor and outdoor unit from any height/ any floor (up to four storey building) including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiion in the same or other building in the complex including refixing of the unit complete all as specified and directed.
Supply and charging the gas refrigerant R22 (including refrigerant) of window/split/cassette/ ductable type AC for 8.5/5.5/3/2/1.5 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed.
All as per item Ser No. 113.00 above but R- 410 for split type/VRF AC up to 14 TR capacity.
All as per item Ser No 113.00 above but R-32 for split/window type AC 4 TR capacity.
S&F in replacement of casing window type AC including company fitted condensing & cooling coil complete including PCB and compressor complete all as specified and directed.
M&L for replacement of split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed.
All as per item Ser No. 117.00 above but 1/2".
S&F in replacement compressor shut off valve 3/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S&F in replacement compressor shut off valve 5/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S&F in replacement of electrolyte grade copper tubing of size 1/4" suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building.
All as per item Ser No. 121.00 above but size 1/2".
All as per item Ser No. 121.00 above but size 3/8".
All as per item Ser No.121.00 above but size 5/8".
S&F in replacement PVC conduit 20mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F in replacement PVC conduit 25mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F in replacement of synthetic rubber foam for insulation for refrigerant copper piping of existing of size 1/4" to 5/8" internal dia split type AC complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building.
S&F in replacement Oil Room Heater 2900 Watt Suitable for 11 Fin, minimum weight 18 Kg with fan complete all as specified and directed.
S&F in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 4 core complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and n. exc 1.5 m depth and getting out in soft/loose soil for poles/laying UG cables of various sizes etc complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm in soft/loose soil complete all as specified and directed.
Removing surplus excavated materials to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
Supply and laying in trenches burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable complete all as specified and directed.
Supply and spread clean dry river sand in trenches ,ducts including levelling for cushioning of cables (8 cm below & 15cm above the cable) complete all as specified and directed. Note : Punned thickness of sand cushioning shall be measured.
S&F of sound proof canopy for 320 KVA DG set with following accessories :- (a) Platform (frame) size channel 5"x 5", Length -18 feet 6 inch, height - 8 feet, wide-7 feet-1 No. (b) Residence silencer - 1 No (c) Lock ( Left-3 & Right-3) - 6 Nos (d) Paint green (e) Door right-3 & Left-3 ( both open), back-1 & front-1 door (f) Heinze sudheer type ( male/female) - 12 Nos (g) Rock Bul 96 x 50 (h) Motor 3 HP, 2.2 KW 3 phase (for cooling) - 1 No (j) XL Fan - 28"-1 No (k) CRC sheet (l) Door bidding (m) Enclosure thickness 4 inch (n) Radiator partition (o) Jali 4 mm complete. Note : The sound proof enclosure should low noise (70 to 72 DBA at 1 mtrs. These are sufficient air for engine aspiration and proper heat dissipation is the fans maintain proper cross flow. Specially designed residential silencers which maintain low noise level.
Supply and laying in replacement of 150 mm dia GI pipe light grade ISI marked complete all as specified and directed.
Supply and laying in replacement of 100 mm dia GI pipe light grade ISI marked complete all as specified and directed.
M&L for painting of transformer indoor/outdoor on platform/plinth/pole with one coat of synthetic enamel paint with compressor spray gun after removing all dust, rust, paint shall confirmed to IS-2032 for 400 to 750 KVA transformer complete all as specified and directed.
S&F in repair Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22, 8.5 metres long poles shall be coated with two coats of black bituminus paint through out internally and externally upto plinth depth. The remaning portion of the exterior shall be painted with one coat of red oxide primer complete all as specified and directed. Note : PCC earth work shall be measured and paid separately.
S&F in replacement of Timer switch Astronomical type ,415 Volt three Phase of 63 Amps rating with Three Pole ML-4 contactor including one Toggle switch for Auto, off and Manual function and incomming MCB TP internally pre wired complete and Fitted inside steel enclosure complete all as specified and directed.
Supply and laying UG cable XLPE insulated, armoured, heavy duty with aluminum conductor, 1100 volts grade of cross sectional area 16 Sqmm, 4 Core in trenches, fixed to wall/pole/tray etc including taking out old unserviceable cable complete all as specified and directed.
All as per item Ser No 141.00 above but 25 Sqmm, 3.5 Core
All as per item Ser No 141.00 above but 35 Sqmm, 3.5 Core
All as per item Ser No 141.00 above but 10 Sqmm, 2 Core
All as per item Ser No 141.00 above but 95 sqmm, 3.5 core
All as per item Ser No 141.00 above but 50 Sqmm, 3.5 Core
Supply and fixing 4 pole MCCB 400 Amps 415 volts, 50 Hz, breaking capacity 36 KA including taking out old unserviceable MCCB and reconnecting with cable complete all as specified and directed.
All as per item Ser No 147.00 above but of capacity 250A- 25 KA.
All as per item Ser No 147.00 above but of capacity 200A, 25 KA
All as per item Ser No 147.00 above but of capacity 320A, 25 KA
All as per item Ser No 147.00 above but of capacity 160A, 25 KA
All as per item Ser No 147.00 above but of capacity 630A-50 KA
M&L in replacement of GI bracket made of 40 mm medium grade GI pipe bend to shape of 1.2 mtr length including Clamps etc complete for fixing of street light complete all as specified and directed.
S&F in repair Junction box SMC KIOSK box water proof of size 140x140x95 mm including fixing of terminal connector 100A 4 pole suitable for in and out connection of 4 core cable fixed on pole complete all as specified and directed.
S&F in replacement Copper cable 2.5 Sqm 3 core PVC sheathed multi core for connection of street light inserting from top in side the pole and connecting in junction box complete including making Hole in Pole etc as per Site condition complete all as specified and directed.
S&F LED Post Top Lantern 40 watt luminaire with diffuser and painted spun aluminium deflector including taking down old unserviceable lantern complete all as specified and directed.
S&F in replacement of Powder coated pressure die cast aluminium SMD LED street light of 45 watt with heat resistant toughened glass including taking down old unserviceable complete all as specified and directed.
S&F Powder coated pressure die cast aluminium SMD LED street light of 90 watt with heat resistant toughened glass including taking down old unserviceable complete all as specified and directed.
S&F Powder coated pressure die cast aluminium SMD LED street light of capacity 120 watt heat resistant toughened glass including taking down old unserviceable complete all as specified and directed
S&F Powder coated pressure die cast aluminium SMD LED street light of 70 watt with heat resistant toughened glass including taking down old unserviceable complete all as specified and directed.
S&F LED flood light with pressure die cast aluminium housing 80 Watt completed with connection including taking down old unserviceable complete all as specified and directed.
S&F LED flood light with pressure die cast aluminium housing 120 Watt completed with connection including taking down old unserviceable complete all as specified and directed.
M&L pole painting 9.0 mtr long with a coat of aluminium paint after preparation of old painting surface by scrappining including marking of black and yellow strip not less than 30 cm width with sythethic enamelled paint from couping to upto height 1.5 mtr of pole alternative way including necessary `MES & Pole number to be wriiten in the circular yellow batch on the pole complete all as specified and directed.
Supply and laying 50 mm dia GI tubes, 'light grade', galvanised, with all fitting laid in trenches complete all as specified and directed.
Supply and laying 80 mm dia GI tubes, 'light grade', galvanised, with all fitting laid in trenches complete all as specified and directed.
S&F Junction box SMC KIOSK box water proof of size 340x280x130 mm incl fixing of terminal connector 100A 4 pole suitable for in and out connection of 4 core cable fixed on pole complete all as specified and directed.
S&F LED flood light with pressure die cast aluminium housing 180 Watt completed with connection including taking down old unserviceable complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) for foundation of electric pole complete all as specified and directed.
M&L for boring of holes under road , pavement , hard standing by trenches techonology using ultra sound technology/ mannualy mechanically and necessary machine for 100 mm dia GI pipe complete all as specified and directed.
Disconnecting old LT panel and earthing outdoor type floor mounted in replacement and supply and fixing / installed, fabricated with 3.15 mm thick CRCA sheet duly CPRI approved, both side openable and size 1200 x1200 x500 mm, outdoor type 3 phase and neutral 4 wire 440 volts cubical type duly powder coating painted having busbar chamber and separate compartment for out going / incoming with and including alluminium bus bar of cap 500 amps-4 Nos on apoxy insulator 1100 volt grade, panel shall be mounted minimum frame 300 mm height from GL, copper internal wiring/connection with and including for following accessories INCOMMING (a) MCCB 415V, 350 A, 4 Pole,35kA, 50Hz with complete accessories- 01 No (b) Alluminium busbar 500A TPN duly screwed. (c) Ammter -01 No (d) LED indications for R-Y-B - 1 set of 3 (e) Volt meter-01 No OUTGOING (a) MCCB 415V,100 A, 4 Pole, 35kA, 50Hz with complete accessories - 5 Nos
S&F of LT cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) for foundation of electric pole complete all as specified and directed.
SNOWY ENGINEERING INC
AARYANS GLOBAL INDIA
Grid Infratech Pvt Ltd
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .