Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹71.4 LAccepted-AOC ERODE 638 002 | ERODE | TAMIL NADU | 638002 | ₹71.4 L Quoted ₹72.6 L | 1 | Accepted-AOC WORK AWARDED |
| 2 | 2₹74.1 LRejected-AOC | ₹74.1 L | 2 | Rejected-AOC Second Lowest |
| Sl No | Description | Qty | Unit | R SURESHMANI L1 | R BALAMURUGAN L2 |
|---|---|---|---|---|---|
| 1.00 | Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of 1 no 20 persons Bed Cum Passenger Gearless With machine room passenger lift as per the following specifications.
1.Location: OP Block at Ambur
2.No of lift: One No
3.Type of lift: Passenger
4.Capacity of lift: 20 persons /1360 Kgs
5.Speed: 1mtr / sec
6.Type of drive: V3F drive with enhanced ride comfort and near zero level functions
7.No of floors: GF+6 Floor
8.Total travel: 3.3MtrX6=19.8 mtr
9.Leveling accuracy: High level accuracy with smooth and jerk free stopping
10. Construction of CAR: No 4 hairline finish high quality stainless steel car hand rail granite flooring and Perspex false ceiling 300mm sweep fan and minor on back side for better aesthetics.
11. Position of machine: directly above the lift well.
12. No of landing service: front side-7 no’s
13. No. of car entrance: one in the front side
14. Car entrance door: power operated automatic V3F drive center opening sliding SS door hariline finish with full length infra red sensor for better safety
15. Landing entrance door: power operated V3F drive center opening sliding SS door hairline finish with provision for emergency exit key at all landings. | 1 | No | 33,00,000 ₹33 L | 33,20,000 ₹33.2 L |
| 1.0116.Lift well Size 2260 X 2950 (MM Wide * MM Depth) as per in standards 17.Lift pit:1600 mm 18. Lift Car Inside Size 1300 X 2400 (MM Wide * MM Depth ) 19. Clear opening of Gates / Doors / Lintel : 1000 X 2000 (MM Wide * MM Height) Lintel - 2000 mm . 20.Lift machine room size:as per the standands 21. Power supply: 415/400V three phase 50HZ AC Supply for power and 230V 50HZ single phase power supply for light 22.Control: micro computer (micro processor) based simplex selective collective control with / without attendant 23. Car fittings: LED lighting (4Nos) with 1 no 300 mm sweep cabin fan. 24. Lift well: RCC construction with brick masonry to be constructed by PWD civil wing 25. Induction: UP / DOWN digital direction and position indicator for all landings and inside the car. 26.Emergency alarm bell: battery operated bell to be provided with automatic charging device 27.Emergency light: battery operated light to be provided with automatic charging device 28.Fire mans switch: to be provided at the GF 29. Minor builder works: to be provided by the lift contractor. 30. Scaffoldings: to be provided by the lift contractor. 31. Sill angles and facia plates: SS to be provided by the lift contractor. 32. Steel for lift machinery: to be provided by the lift contractor. 33. Servicing and maintenance: free comprehensive servicing and maintenance for one year Guarantee period to be provided by the lift contractor. | |||||
| 1.0234. Automatic rescue device: to facilitate the lift to the landing of the nearest floor at the time of power failure this shall consist of suitable battery system with charger inverter under voltage protection system etc. complete with all accessories. 35. Provision for intercom with phone: to be provided by the lift contractor. 36.Lift license: preparation of drawings payment of charges to CEIG and insurance policy if any and obtaining CEIG approval for the lift as per lift act should be done by the lift contractor 37. Floor position announcer: to be provided by the lift contractor. 38.Special features a) Infra red door sensor with full height screen b) Full width half height rear panel mirror c)Tubular SS hand rail in car d) Stainless steel signal features e) Vandal proof SS button with SS cover f) SS door frames for landing doors g) V3F door operator h) Call register signal i) Stainless steel facia plates for car operating panel and landing fixtures j) Steel ladder for lift machine room k) On / off switch for fan and light l) Over load warning indicator with audio announcer | |||||
| 1.03m)Voltage stabilizer for control circuits n)Braille button 39.Over speed governor phase failure and phase reversal relay alarm bell T guide brackets for car and counter weight rubber padding under the winding unit motor of adequate capacity speed reduction worm gear electromagnetic brake with compression springs car safety gears buffers electro mechanical locks emergency key side supporting angles motor over load protection devices final limit switch main suspension ropes counter weight lifting joist for mounting the machineries 40. Guarantee: guarantee at least for one year for the material and workmanship of equipments should be offered by the lift contractor. 41. Site testing in accordance with IS 14665 should be carried out at the time of handing over to the user department 42. Supply operation and maintenance manual and necessary tools for operation and a set of Spare parts required for one year. | |||||
| 2.00 | Supply , Testing Commissioning and Handing over of 1 No 250 KVA Diesel Generator set (Diesel Generator Set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specifications) of 0.8 P.F. Three phase 415V/ 420 Volts, 50Hz, 1500 RPM CPCB Approved capacity comprising of Kirloskar Engine model 6R 1080TA developing 154 BHP water cooled clock wise rotating feed pump with 100KW/ 250KVA operating capacity brushless alternator close coupled underneath fuel tank standard safeties LLOP with stop solenoid battery with lead Electric start and vibration fitting and accessories and AMF panel as detailed below including transporting & unloading charges.
(A) Engine:
Water cooled diesel engine suitable for Generator application with a shaft out put of 154BHP at 1500 RPM under NTP conditions. The Engine shall comprise the following standard fitting flexible coupling fly wheel, ai cleaner, fan blower, radiator, water pump, fuel filter, lubricating oil filter, etc.
(B) 12/24 Volt Electronic starting Equipment:
Complete with starter motor, dynamo, standard batteries with cable, flexible exhaust piping of 50cm length.
(C) ENGINE INSTURMEN PANEL / MOUNTED:
Starting push botton / starting key, lubricating oil, temperature gauge, lubricating oil pressure gauge, water temperature gauge, safety control for low lubricating oil, pressure, safety control for high water temperature, safety control for over speed, hour meter (mechnical ) and RPM indicator, battery charging ammeter. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous at full load. | 1 | No | 28,50,000 ₹28.5 L | 29,60,000 ₹29.6 L |
| 2.01(D)ALTERNATOR: 250KVA/200KW Capacity of brushless alternator, AC 3 phase, 50Hz, 415/420V, 0.8 PF, 1500 RPM under NTP conditions, conforming to IS:13364 (Part-II)/ 1992 to be means of coupling. (E) AMF CONTROL PANEL: The AMF control panel (cubical) should be fabricated with vermin proof and dust proof best quality sheet steel and floor mounted with removable rear panels and hinged front doors with enamel painted and incorporating the following with suitable provision for connection incoming and outgoing leads having been made on the control panel. 1. AC Ammeter and selector switch. 2 . Volmeter and selector switch. 3. 3Nos current transformer with suitable ratio 4. Frequency meter 5. KWH meter 6. 1 No power factor meter 7. Battery charging set comprising of the following for charging the battery from mains a. Transformer / Rectifer b. DC Ammeter c. DC Volt meter d. ON / OFF switch e. Charging rate selector switch f. push button start g. push button stop h. push button reset 8. 1 set Air break contactor with auxiliary neutral contactor for main supply | |||||
| 2.029. 1 set Low voltage HRC fuse for the short circuit protection of the main supply 10. 1 set Alternator contactor with auxiliary neutral contactor. 11. 1 set Three pole bimetal release for over load protection of alternator 12. 1 set low voltage HRC fuse for the short circuit protection of the alternator 13.1 set DC control relays incorporating engine start/ stop and failure to start / lockout 14. 1 set selector switch auto/ manual 15. 1 no Push button "Start" 16. 1 no Push button "Stop" 17. 1 no Push button "Reset" 18.1 No signal lamp for indicating load on mains 19. 1 no signal lamp for indicating load on set. 20.1no signal lamp for indicating set fails to start. 21.1no signal lamp for indicating set running. 22.1No signal lamp for indicating battery 23. 1set Pilot lamps of 3 nos 24. MCCB of 250A capacity with magnetic thermal overload release, instant start circuit trip and under voltage release switch. 25.Rectangular copper bus bars (1No for each phase, neutral and earthing terminals) of adequate capacity duly colour coded with head shrinkable PVC sleeves. | |||||
| 2.0326.1No mains voltage monitor 27.Hooter/Audio alarm for indicating set fails to start and for DG O/L. 28.1set Timers 29.Audio and Visual indicator arrangements for: a) Low lubricating oil pressure b) High water temperature c) Over speed 30.1No Earth fault relay 31.Isolator to isolate the neutral Note:- 1. The control panel should be complete with necessary fuses, cables, label, other accessories with neutral isolation arrangements. 2. The engine should trip for the following: a) Low lubricating oil pressure b) High water temperature c) Over speed 3.Supply and fitment of Auto Mains Failure Panel, 1 EB Service wih 200 Amps switch and contactors SUF Control relays, timers etc suitable for auto change over of DG & EB Service. F.FUEL TANK Fuel tank of 200 litres capacity and with inlet and outlet connections, level indicator with scale etc. G.BASE FRAME: Base frame should be fabricated with MS channel frame of rigidly welded construction for mounting of generaor set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame wih proper alignment. | |||||
| 2.04H) ACOUSTIC ENCLOSURE: The Acoustic enclosure, Self standing weather proof KG- CPCB Typed Acoustic canopy KG 250WS floor mounting type with modular construction with the provision to assemble and dismantle easily and designed to suit all weather condtions. Erection of acoustic enclosure suitable for 250KVA Diesel generator complete with all accessories as above and suitable supports etc. 1. Supply of manuals for operation & maintenance of DG set with warranty card etc. | |||||
| 3.00 | GST @ 18% | 1 | No | 11,07,000 ₹11.1 L | 11,30,400 ₹11.3 L |
Tender Value
₹71.4 L
EMD Value
₹46,000
Closing Date
6 Jan 2026, 3:00 pmClosed
The Superintending Engineer, PWD.,
The Superintending Engineer, PWD., Buildings Construction and Maintenance Circle,Tiruvannamalai-4.
Providing 1 No 20 Bed cum passenger lift and 1 No 250 KVA Generator set (CPCB IV) at OP Block Building in Government Hospital at Ambur in Tirupathur District
2025_PWD_637969_1
61/TVM-CLE/25-26/1/ Dt.16.12.2025
Open Tender
Electrical Works
90 days
Ambur
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹46,000
12 Mar 2026
31 Dec 2025
6 Jan 2026
31 Dec 2025
6 Jan 2026
31 Dec 2025
Amount
Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of 1 no 20 persons Bed Cum Passenger Gearless With machine room passenger lift as per the following specifications. 1.Location: OP Block at Ambur 2.No of lift: One No 3.Type of lift: Passenger 4.Capacity of lift: 20 persons /1360 Kgs 5.Speed: 1mtr / sec 6.Type of drive: V3F drive with enhanced ride comfort and near zero level functions 7.No of floors: GF+6 Floor 8.Total travel: 3.3MtrX6=19.8 mtr 9.Leveling accuracy: High level accuracy with smooth and jerk free stopping 10. Construction of CAR: No 4 hairline finish high quality stainless steel car hand rail granite flooring and Perspex false ceiling 300mm sweep fan and minor on back side for better aesthetics. 11. Position of machine: directly above the lift well. 12. No of landing service: front side-7 no’s 13. No. of car entrance: one in the front side 14. Car entrance door: power operated automatic V3F drive center opening sliding SS door hariline finish with full length infra red sensor for better safety 15. Landing entrance door: power operated V3F drive center opening sliding SS door hairline finish with provision for emergency exit key at all landings.
34. Automatic rescue device: to facilitate the lift to the landing of the nearest floor at the time of power failure this shall consist of suitable battery system with charger inverter under voltage protection system etc. complete with all accessories. 35. Provision for intercom with phone: to be provided by the lift contractor. 36.Lift license: preparation of drawings payment of charges to CEIG and insurance policy if any and obtaining CEIG approval for the lift as per lift act should be done by the lift contractor 37. Floor position announcer: to be provided by the lift contractor. 38.Special features a) Infra red door sensor with full height screen b) Full width half height rear panel mirror c)Tubular SS hand rail in car d) Stainless steel signal features e) Vandal proof SS button with SS cover f) SS door frames for landing doors g) V3F door operator h) Call register signal i) Stainless steel facia plates for car operating panel and landing fixtures j) Steel ladder for lift machine room k) On / off switch for fan and light l) Over load warning indicator with audio announcer
m)Voltage stabilizer for control circuits n)Braille button 39.Over speed governor phase failure and phase reversal relay alarm bell T guide brackets for car and counter weight rubber padding under the winding unit motor of adequate capacity speed reduction worm gear electromagnetic brake with compression springs car safety gears buffers electro mechanical locks emergency key side supporting angles motor over load protection devices final limit switch main suspension ropes counter weight lifting joist for mounting the machineries 40. Guarantee: guarantee at least for one year for the material and workmanship of equipments should be offered by the lift contractor. 41. Site testing in accordance with IS 14665 should be carried out at the time of handing over to the user department 42. Supply operation and maintenance manual and necessary tools for operation and a set of Spare parts required for one year.
Supply , Testing Commissioning and Handing over of 1 No 250 KVA Diesel Generator set (Diesel Generator Set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specifications) of 0.8 P.F. Three phase 415V/ 420 Volts, 50Hz, 1500 RPM CPCB Approved capacity comprising of Kirloskar Engine model 6R 1080TA developing 154 BHP water cooled clock wise rotating feed pump with 100KW/ 250KVA operating capacity brushless alternator close coupled underneath fuel tank standard safeties LLOP with stop solenoid battery with lead Electric start and vibration fitting and accessories and AMF panel as detailed below including transporting & unloading charges. (A) Engine: Water cooled diesel engine suitable for Generator application with a shaft out put of 154BHP at 1500 RPM under NTP conditions. The Engine shall comprise the following standard fitting flexible coupling fly wheel, ai cleaner, fan blower, radiator, water pump, fuel filter, lubricating oil filter, etc. (B) 12/24 Volt Electronic starting Equipment: Complete with starter motor, dynamo, standard batteries with cable, flexible exhaust piping of 50cm length. (C) ENGINE INSTURMEN PANEL / MOUNTED: Starting push botton / starting key, lubricating oil, temperature gauge, lubricating oil pressure gauge, water temperature gauge, safety control for low lubricating oil, pressure, safety control for high water temperature, safety control for over speed, hour meter (mechnical ) and RPM indicator, battery charging ammeter. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous at full load.
26.1No mains voltage monitor 27.Hooter/Audio alarm for indicating set fails to start and for DG O/L. 28.1set Timers 29.Audio and Visual indicator arrangements for: a) Low lubricating oil pressure b) High water temperature c) Over speed 30.1No Earth fault relay 31.Isolator to isolate the neutral Note:- 1. The control panel should be complete with necessary fuses, cables, label, other accessories with neutral isolation arrangements. 2. The engine should trip for the following: a) Low lubricating oil pressure b) High water temperature c) Over speed 3.Supply and fitment of Auto Mains Failure Panel, 1 EB Service wih 200 Amps switch and contactors SUF Control relays, timers etc suitable for auto change over of DG & EB Service. F.FUEL TANK Fuel tank of 200 litres capacity and with inlet and outlet connections, level indicator with scale etc. G.BASE FRAME: Base frame should be fabricated with MS channel frame of rigidly welded construction for mounting of generaor set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame wih proper alignment.
H) ACOUSTIC ENCLOSURE: The Acoustic enclosure, Self standing weather proof KG- CPCB Typed Acoustic canopy KG 250WS floor mounting type with modular construction with the provision to assemble and dismantle easily and designed to suit all weather condtions. Erection of acoustic enclosure suitable for 250KVA Diesel generator complete with all accessories as above and suitable supports etc. 1. Supply of manuals for operation & maintenance of DG set with warranty card etc.
R BALAMURUGAN (BID ID -1554305)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
BOQ_763511.xls
BOQ • 0.26 MB
AmburLift_Cond.pdf
Tender Documents • 0.53 MB
Download all tender documents and submit your bid