| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L1 | Accepted-AOC Tender awarded to M/s Trade Link being L-1 | |
| 2 | L2₹18.0 L+₹2.0 L (12.3%)Rejected-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L2 | Rejected-AOC Not being lowest | |
| 3 | L3₹18.6 L+₹2.6 L (16.1%)Rejected-AOC 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L3 | Rejected-AOC Not being lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
23 Jun 2022, 6:00 pmClosed
GE
GE 860 EWS
REPAIR/MAINTENANCE OF CENTRAL HEATING PLANT AND REPLACEMENT OF INSULATION PPR PILES, CONTROL VALVES, HEATERS, TOPPING UP OF GLYCOL, HOT WATER SUPPLY AND CAPTIVE REPAIR TO VARIOUS DG SET SERVICES AND REPLACEMENT OF MINOR PARTS, CONTROL PANELS AND ALLI
2022_MES_526407_1
8146/2022-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Tangtse
Class E Category b i and c i
9 documents required · 9 mandatory
₹500
Yes
GE 860 EWS
₹50,000
Yes
6 Aug 2022
26 May 2022
30 Jun 2022
26 May 2022
23 Jun 2022
9 Jun 2022
Amount
M & L for Dismantling of burner rod assy and removing of side cover of boiler capacity 3 lakh kilo/cal/hr and complete servicing the boiler by using coil shine chemical and removing the complete carbon/oil deposits including repair to coil assy if there is any leakage found or any other repair required at site and reassembling/testing the same complete all as specified and directed by Engr-in-Charge.
M & L for sequence controller suitable for 03 lakh Kilo/Cal/hr burner rod assy all as specified and directed by Engr-in-Charge. Make:Seimens/L&T/Schneider
M & L for ignition rod suitable for 3 Kilo/Cal/hr burner rod assy all as specified and directed by Engr-in-Charge.
M & L for replacement of Ignition Transformer electronic type suitable for 03 lakh Kilo/Cal/hr burner rod assy all as specified and directed by Engr-in-Charge.Make:Seimens/L&T/Schneider
M & L for replacement of diesel filters suitable for boiler of capacity 3 Lakh K cal/Hr as per existing complete all as directed by Engr-in-Charge.
M & L for complete servicing of diesel pumps suitable for boiler of capacity 3 Lakh K cal/Hr including replacement of bearings, seal etc as per site requirement complete all as directed by Engr-in-Charge.
Supply and replacement of old diesel burner set of capacity 1 Lac kcal/hr comprising of diffuser,nozzle,electrodes,blast tube,solenoid valve,air damper adjustment,gear pump,coupling set,oil supply pipe,gasket,ignition transformer,reset button,flame detector and controller complete. Make:Ecoflam,Aquatherm,Rapid therm
Supply and fixing of 1 HP Motor Electric driven single phase 230 volts complete all as specified and directed by Engr in Charge.
supply and fixing temp controller digital type DTC 503 with sensor suitable for 3 lakh Kilo/Cal/Hr LAL 2.25 burner rod assembly ,complete all as specified and as directed. Make- Siemens or equivalent.
Supply and fixing in replacement of High Pressure Fuel pipe 1.5 Mtr as per existing ,complete all as specified and directed by Engr in Charge.
Supply and fixing in replacement of Electrode suitable for burner of capacity 1-2 Lakh k/cal/hr, complete all as specified and directed by Engr in Charge.
M & L for Dismantling of burner rod assy and removing of side cover of boiler capacity 3-4 lakh kilo/cal/hr and complete servicing the boiler by using coil shine chemical and removing the complete carbon/oil deposits including repair to coil assy if there is any leakage found or any other repair required at site and reassembling/testing the same complete all as specified and directed by Engr-in-Charge.
M & L for sequence controller suitable for 03-04 lakh Kilo/Cal/hr burner rod assy all as specified and directed by Engr-in-Charge. Make:Seimens/L&T/Schneider or as per existing make
M & L for ignition rod suitable for 3 lakh Kilo/Cal/hr burner rod assy all as specified and directed by Engr-in-Charge.
M & L for replacement of Ignition Transformer electronic type suitable for 03-04 lakh Kilo/Cal/hr burner rod assy all as specified and directed by Engr-in-Charge.Make:Seimens/L&T/Schneider
supply and fixing temp controller digital type DTC 503 with sensor suitable for 3-4 lakh Kilo/Cal/Hr LAL 2.25 burner rod assembly ,complete all as specified and as directed. Make- Siemens or equivalent.
Supply and fixing burner nozzle suitable for 3-4 Lakh kilo/Cal/hr complete all as specified and as directed by Engr in Charge.
M & L for complete servicing of diesel pumps suitable for boiler of capacity 3-4 Lakh K cal/Hr including replacement of bearings, seal etc as per site requirement complete all as directed by Engr-in-Charge.
Supply and fixing in replacement of High Pressure Fuel pipe 1.5 Mtr as per existing ,complete all as specified and directed by Engr in Charge.
M & L for replacement of digital type Amp meter complete with touch control switch and suitable CTs 0 - 300 Amps complete all as directed by Engr-in-Charge. Make : AE/L&T/ Schneider
M & L for replacement of indicating lamps RYB as per existing complete all as directed by Engr-in-Charge.Make : AE/L&T/ Schneider
M & L for replacement of push botton type ON/OFF switches as per existing complete all as directed by Engr-in-Charge.
Supply and filling of Methy/Ethylene Glycol(MEG) of 99% purity and minus forty degree centigrade fressing temperature in Sealed Container for Central heating Plant Complete all as specified and directed by Engr in Charge.Note : Container is a deposited to MES Store Yard.
M&L for Cleaning of MS diesel storage tanks of capacity up to 10000 ltrs by removing of sludge from tank and scraping the side walls by means of wire brush or emery paper and wash the same with castic soda and clear water and painting the internal walls with two coats of black rubber immelsion paint and painting the complete tank from out side with two coats of synthetic enamel paint complete all as specified and directed.
M&L for Cleaning of MS overhead Glycol storage tank of any capacity including all type of T&P and chemical required for the same, including welding work to leakage surface including opening and refixing the existing insulating materials to the external surfaces of the tank.
M&L for cleaning of MS overhead POL storage tank of capacity 2000/1000 Ltr including all type of T&P and chemical required for the same, including welding work to leakage surface including opening and refixing the existing insulating materials to the external surface of storage tank.
S&F in replacement insulation 13mm thick as per existing with all fixing arrangements to the all sizes of pipes properly complete all as specified and directed. Make-Caflese, K-Flex.
Supply only over load relay 1.25 to 2 Amps for contactor matching ser no 49 series 3 TF 33 Make- Siemens, complete all as specified and directed.
Supply and fixing in replacement PVC flexible copper multistranded wire 3 core of 6 Sqmm , complete all as specified and as directed.
S&F in replacement of FCU connection flexible pipe 20/16 mm as per existing, complete all as specified and directed. Make- Jindal/Kitetac.
S&F in replacement of inlet/outlet forged brass ball valve 15/20/25 mm with Y Stainer for FCU, hot water for -25 to 90 degree temperature as per existing,including supply and fixing suitable size of MS / GI nipple of size inch including welding work, cutting the existing rusty unserviceable MS/GI nipple complete all asspecified and directed.
M&L for Electrical Control Wiring for FCU of any size including electronic display complete as per sample all as specified and directed.
M &L for Servicing and Maint of existing FCU installed at 34 AP by detecting leakage and rectify the leakage by using clamps, washer, nut bolts etc all as directed at site by Engr-in-charge.
M&L for Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comprising of Engine/ Alternator/ Control panel) of the following capacity for smoth functioning complete all as per manufacturers instructions and all as directed by Eng in Charge A. (a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and correcting the same (c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tension properly (e) Cleaning of air filters (f) Checking and readjusting the valve clearance (g) Change of Oil/Fuel filters and engine oil if necessary (h) Checking of starter motor battery and charger (i) Checking of cooling system and fuel system (j) checking of all power cables and AVR connections and mounting bolt tightnees of alternator (k) checking the function of AVR genaral checks (l) Checking of control panel meters and gadgets functiong (m) Checking of all control and safety wirings B. (a) Checking of flexible coupling of engine and alternator (b) Cleaning of crank case ventilation pipe (c) Checking of injectors and fuel pump (d) Checking of alternator and carbon brushes of following capacity DG sets NOTE: (1) Cost of Spare parts required will be paid and measured separately (2) Servicing/routine check up carried out through authorised service centre of manufacturer (3) Make of spare recommendation by auth service centre of manufacturer.
320 KVA DG Sets
160 KVA DG Set
100/125 KVA DG Set
63 KVA DG set
35/40 KVA DG set
S&F in replacement of Air Cleaner Element (inner & outer) suitable for following capacity of DG Set. Air cleaner will be changed after every 500 hrs or when reqd complete all as specified and directed.Make MICO/Sakura/ Fleetguard
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
S&F in replacement of Fuel filter Element (Primary & Secondary) for following capacity of DG Set: (Fuel filter will be changed after every 250 hrs or when reqd) complete all as specified and directed.
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
S&F in replacement of Lub Oil Filter Element for DG Sets of following capacity (Lub oil filter will be changed after every 250 hrs or when reqd) complete all as specified and directed .
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
S&F in replacement of ‘V’ belt suitable for alternator of following capacity of DG Sets complete all as directed by Engr in Charge:-
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
Replacement of 'V' belt for radiator/water pump suitable for following capacity DG Sets complete all as specified and directed by Engr-in-Charge. Make Kirloskar/Cummins/Greaves
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
Replacement of fuel pipe with banjo bolt at both side suitable for following capacity DG sets complete all as specified and directed by Engr-in-Charge.
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
Repair of Dynamo/Alternator Assy for following capacity DG Set complete all as specified and directed by Engr-in-Charge.
320 KVA DG Set
160 KVA DG Set
100 KVA DG Set
63 KVA DG set
M & L for changing /toping up of best quality of engine oil 20W50 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed
Supply only cotton waste for daily use for cleaning the DG sets complete all as specified and directed.
Supply and fill batteries distilled water for the DG sets of all Dg set complete all as specified and directed.
Supply and fill batteries electrolyte for the DG sets at all DG Sets complete all as specified and directed.
S&F replacement of auotmatic voltage regulator(AVR) 24 volt all as specified and directed by Engr in Charge.
320 KVA DG Set
160 KVA DG Set
63 KVA DG set
M& L for Replacement of water pump assembly for following capacity DG sets complete all as specified and directed by Engr-in-Charge.
320 KVA DG Set
63 KVA DG set
Supply and replacement of self starter for following capacity DG Set complete all as specified and directed by Engr-in-Charge.
320 KVA DG Set
63 KVA DG set
Replacement of Turbo charger assy.for following capacity DG sets complete all as specified and directed by Engr-in-Charge.
320 KVA DG Set
63 KVA DG set
M&L for Replacement of Fan Hub assembely for following capacity of DG Set complete all as specified and directed by Engr in Charge.
320 KVA DG Set
63 KVA DG set
M & L for taking out burnt winding of exciter of following capacity of DG Sets including re-winding copper wire of super quality, of existing size, No of turns, varnishing, heating complete including testing on full load to entire satisfaction of Engr in Charge.
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
M & L Cleaning of radiator for following capacity DG sets by using Keroscene oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and necessary welding/brazing and Re-assembling after painting of the same complete all as directed.
320 KVA DG Set
63 KVA DG set
35/40 KVA DG set
Supply & fixing in replacement of DC wiring of following capacity of DG Sets , complete all as specified and directed by Engr-in-Charge.
63 KVA DG set
35/40 KVA DG set
Supply & fixing in replacement of Hose Pipe of following capacity of DG Sets complete all as specified and directed by Engr-in-Charge.
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
M&L for Strip opening of alternator 100 KVA DG set , removing rotor from the stator and rewinding to CT coils complete with super enameled copper winding wire of appropriate size including insulating material and replacing the following parts of the alternator.Note: Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.
Supply and Replacement of lub oil pump suitable for following Capacity DG Sets complete all as specified and directed by Engr-in-Charge.
100 KVA DG Set
63 KVA DG set
Supply and Replacement of Thermostate valve suitable for following Capacity DG Sets complete all as specified and directed by Engr-in-Charge.
320 KVA DG Sets
160 KVA DG Set
125/100 KVA DG Set
63 KVA DG set
35/45 KVA DG set
Supply and Replacement of Oil seal front and rearsuitable side for following Capacity DG Sets Complete all as specified and directed by Engr-in-Charge.
320 KVA DG Set
160 KVA DG Set
100/125 KVA DG set
63 KVA DG set
35/40 KVA DG set
Supply and Replacement of battry terminal for DG Sets complete all as specified and directed by Engr-in-Charge.
Supply and fixing battery cable assy. with copper conductor multistranded RED and BLACK colour 2mtr long 21sqmm for connection to self starter unit to Battery unit complete.
M & L for Calibration of Injector unit including supply & fixing in replacement O-Ring, Pin roll, barrel, Pin spring, washer and testing up to 320 KVA Set complete all as specified and as directed by Engr in Charge.
M & L for Calibration of FIP including supply & fixing in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring, washer and testing for following capacity of DG Set complete all as specified and directed by engr in Charge.
320 KVA DG Set
160 KVA DG Set
63 KVA DG set
35/40 KVA DG set
M&L for supply and fixing in replacement of Crank wheel suitable for 63/125/100 KVA DG set complete all as specified and directed by Engr-In-Charge
M&L for supply and fixing in replacement of Crank wheel suitable for 320 KVA DG set complete all as specified and directed by Engr-In-Charge
Supply and topping uo of best quality antifreezing ,inhabitor (Coolant) liquid for DG Set of various capacity and locations complete all as specified and directed.
M & L for replacement of exhaust silencer of 63/100 KVA DG set complete all as specified and directed by Engr in Charge.
Calibration of electronic panel of 160 KVA Cummins DG set with Laptop and fixing all fault by cummins engineer all as directed at site
Dismantling of electronic nozel from 160 KVA DG Set and Calibrate electronic nozel from company and refixing the same all as directed by engineer in charge
Supply and fixing DG Set battery of 12 V 180 AH including first filling of distrilled water all as directed at site.Make : Exide/Amaron
Supply and fixing diode kit of 160 KVA stamford alternator of Cummins DG Set all as directed at site.
Supply and fixing head geskit set of 160 KVA DG Set of Cummins
national engineering
EESSI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .