Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 CrAccepted-AOC 660 POLICE LINE AREA HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹12.2 Cr | L1 | Accepted-AOC reasonable lowest bid |
| 2 | L2₹12.8 CrRejected-Finance | ₹12.8 Cr | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹13.4 CrRejected-Finance UNIT B2 AUTONAGAR VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530012 | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹13.4 Cr | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹13.6 CrRejected-Finance | ₹13.6 Cr | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹14.4 CrRejected-Finance | ₹14.4 Cr | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹12.4 Cr
EMD Value
₹9.4 L
Closing Date
6 Dec 2021, 6:00 pmClosed
CE RandD Secunderbad
CE RandD Secunderbad Opp Jubilee Bus Station
PROVISION OF CIVIL WORKS FOR MACHINE PLANNING SYSTEEM AND DUAL MODE SEEKARS MPDMS AT RCI HYDERABAD
2021_MES_479341_1
CA NO.CERD/SEC/TOKEN/06 OF 2021 -2022
Open Tender
Civil Works
365 days
Hyderabad
As per NIT
8 documents required · 8 mandatory
₹3,000
GE (I) R and D RCI Hyderabad
₹9.4 L
Yes
CE RandD Secunderbad
31 Dec 2021
4 Oct 2021
13 Dec 2021
4 Oct 2021
6 Dec 2021
29 Nov 2021
4 Oct 2021 - 18 Oct 2021
14 Oct 2021
Amount
Schedule 'A' Part - I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl. item No. 1.01 to 1.08) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for Construction of technical building (G+2) with provision of future expansion, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of AC Plant room, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of Sub station building, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of Car parking shed-1, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of Car parking shed-2, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of Motor cycle parking shed, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of RCC septic tank of 100 users, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of Soakage well of size 2.40 m dia and 4.50 m effective depth, complete all as shown on drawings and as specified.
Schedule 'A' Part-II (SITE CLEARANCE AND EARTH WORK EXCAVATION) This Schedule (contains under mentioned Sl item No. 2.01 to 2.23) is not prepriced by MES and the prepriced rate indicated in Col 5 as `0.00 indicates this fact only. The tenderer is required to quote their rates in Col 6. The unit rates quoted against item No. 2.01 to 2.23 is deemed to be included execution of work either manually or by mechanical means.
Surface excavation not exceeding 30m deep and averaging 15cm deep soft / loose soil complete all as specified and directed.
Surface excavation not exceeding 30m deep and averaging 15cm deep hard / dense soil complete all as specified and directed.
Surface excavation not exceeding 30m deep hard / dense soil complete all as specified and directed.
Excavation over areas not exceeding 1.5m deep and getting out in soft / loose soil complete all as specified and directed.
Excavation over areas not exceeding 1.5m deep and getting out in hard / dense soil complete all as specified and directed.
Excavation over areas not exceeding 1.5m deep and getting out in soft / disintegrated rock complete all as specified and directed.
Excavation over areas not exceeding 1.5m deep and getting out in hard rock complete all as specified and directed.
Excavation over areas exceeding 1.5m deep and not exceeding 3m in hard / dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding1.5m depth and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding1.5m depth and getting out in hard / dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding1.5m depth and getting out in soft / disintegrated rock complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in hard rock complete all as specified and directed.
Excavation in trenches exceeding 1.5m deep and not exceeding 3m deep in hard / dense soil complete all as specified and directed.
Excavation in trenches exceeding 1.5m deep and not exceeding 3m deep in soft / disintegrated rock complete all as specified and directed.
Excavation in trenches exceeding 1.5m deep and not exceeding 3m deep in hard rock complete all as specified and directed.
Returning, filling in excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removal of surplus soil to a distance exceeding 50m and depositing where directed to a level not exceeding 1.50m above the starting point complete all as specified and directed.
Removal of surplus rock to a distance exceeding 50m and depositing where directed to a level not exceeding 1.50m above the starting point complete all as specified and directed.
Removal of excavated soil to a distance exceeding 50m and not exceeding 250m depositing where directed to a level not exceeding 1.50m above the starting point complete all as specified and directed.
Removal of excavated soil to a distance exceeding 250m and not exceeding 500m depositing where directed to a level not exceeding 1.50m above the starting point complete all as specified and directed.
Removal of excavated rockl to a distance exceeding 500m and not exceeding 1.5 KM depositing where directed to a level not exceeding 1.50m above the starting point complete all as specified and directed.
Forming embankments including raising (or lowering) earth, spreading in layers not exceeding 30cm thick, watering, ramming / rolling and finishing to requried size, shape etc, not exceeding 1.50m high from base complete all as specified and directed.
Demolition of concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Lump sum price worked out by the Contractor for “ ROADS AND CULVERTS ” as listed in Schedule ‘A’ Part - III representing _______ % ______________ percent Above / Below the lump sum price of `38,24,717.90 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “ SEWAGE DISPOSAL ” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of `6,01,762.15 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for " AREA DRAINAGE” as listed in Schedule ‘A’ Part - V representing _______ % __________________ percent Above / Below the lump sum price of `19,89,219.58 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for " GATE / RAIN WATER HARVESTING” as listed in Schedule ‘A’ Part - VI representing _______ % __________________ percent Above / Below the lump sum price of `4,23,038.41 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VII representing _______ % _________________ percent Above / Below the lump sum price of `40,853.92 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “ INTERNAL ELECTRIFICATION / UPS WIRING” as listed in Schedule ‘A’ Part - VIII representing _______ % _________________ percent Above / Below the lump sum price of `9,85,776.05 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part - IX representing ______ % _________________ percent Above / Below the lump sum price of ` 1,49,906.40 inserted by the MES in Schedule ‘A’ Part - IX
Lump sum price worked out by the Contractor for “ LIGHTENING PROTECTION ” as listed in Schedule ‘A’ Part - X representing ______ % _________________ percent Above / Below the lump sum price of `1,50,783.30 inserted by the MES in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “ EXTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’ Part - XI representing ______ % _________________ percent Above / Below the lump sum price of `55,70,631.22 inserted by the MES in Schedule ‘A’ Part - XI
Lump sum price worked out by the Contractor for “ FIRE ALARM SYSTEM ” as listed in Schedule ‘A’ Part - XII representing ______ % _________________ percent Above / Below the lump sum price of ` 5,10,846.00 inserted by the MES in Schedule ‘A’ Part - XII
Lump sum price worked out by the Contractor for “ FIRE FIGHTING SYSTEM ” as listed in Schedule ‘A’ Part - XIII representing ______ % _________________ percent Above / Below the lump sum price of ` 21,35,617.24 inserted by the MES in Schedule ‘A’ Part - XIII
Schedule 'A' Part - XIV This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 15.00 to 122.00
ROADS AND CULVERTS Supply and fix, retro reflective traffic road cautionary sign boards made of 14 guage (2.00mm) thick aluminium sheet of size 800 x 600 mm rectangular having one coat of zinc chromate stoving primer and two coats of stoving enamel on back side only and front surface fully covered with white encapsulated lens retro-reflective sheeting of high intensity grade. The sheet is to be adhered to the base by HLVA process. The size of border and sign shall be as per IRC-67/1977, the board shall have back support frame of MS angle of size 35x35x5 mm and shall have arrangements for fixing to post complete all as specified and directed.
M&L for 100 mm bore MS pipes as in post of wall thickness 4.5mm conforming to IS-1161-1979 of grade St-240 and 10 ft long including excavation in post holes and PCC bed block 1:2:4 type B-1 of size 450x450x600mm, removal of surplus soil and levelling the ground including two coats of epoxy post to MS post complete all as specified and directed.
M&L for Road Marketing Strips, Lines, Dashes, Arrows, Letters etc of 2.5mm thick (Reflective Type} of colour white or Golden Yellow on roads, pavements and the like exceeding 10cm wide with Hot Thermo Plastic Material by fully automatic thermoplastic paint applicator machine, fitted with profile shoe, glass beads dispenser, skilled operator on road surface including cleaning the road surface of all dirt, scales, oil grease and foreign materials etc complete all as specified and as directed.
AREA DRAINAGE Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
GATE / RAIN WATER HARVESTING Boring hole 250mm dia by DTH cum Rotary method to a 120 mtr depth below the ground level in any kind of rock/soil including disposal of surplus soil to a distance not exc 50 metres away all as specified and directed by Engr-in-Charge.
M&L for gravel filling (River stone) of size 40 to 60mm dia in under pit / Bore holes complete all as specified and directed.
M&L for gravel filling (River stone) of size 60 to 100mm dia in under pit / Bore holes complete all as specified and directed.
S&F PVC (SWR) pipe 160mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipe 300mm dia single socketed in any length with rubber ring joints laid in trenches / bore holes complete all as specified and directed.
S&F PVC (SWR) perforated pipe 300mm dia single socketed in any length with rubber ring joints laid in trenches / bore holes complete all as specified and directed.
S&F PVC (SWR) 160mm dia vent cowl complete all as specified and directed.
ARBORICULTURE Moorum/red bajri brought from out side MD land filling in floors or paving layers in n.exc 15 cm thick, spread, levelled and rammed incl watering Note: Measurement shall be taken after consolidation. The rate is deemed to be inclusive of required manner complete all as specified and directed.
Supply only approved earth without pebble brought from outside MD land for planting grass complete all as specified and directed.
Supply only clean river sand free from dust organic and other extremious matter and shall not contain 5% clay /silt for planting grass complete all as specified and directed.
Labour only for mixing spreading/levelling, watering and well ramming sand with approved earth in the proportion 1:2 for planting of grass in layers n.exc 25 cm thick including, bome metal insecticides as per the requirement and as directed by Engineer-in-charge complete all as specified and directed.
Continuous brick edging with width equal to the depth of the brick, laid dry on end at the required angle with old size bricks sub-class 'B' bricks. Note: The rate includes for embedding bricks in the ground depth as directed and tamping ground around bricks and also removing any surplus soil complete all as specified and directed.
Supply and planting mexicam grass (Carpet Grass) including providing manure complete all as directed.
Supply and planting Koren grass (Carpet Grass) including one year maintenace complete all as directed.
Supply & planting sycus leaf plant complete all as directed.
Supply & planting shampane palm complete all as directed.
Supply & planting triangle old palm complete all as directed.
Supply & Planting travellers palm complete all as directed.
Supply & Planting Royal Palm complete all as directed.
Supply & Planting Tables palm complete all as directed.
Supply & Planting Tables palm complete all as directed.
Supply & Planting Fan Pan Palm complete all as directed.
Supply & Planting Red Palm complete all as directed.
Supply & Planting Yellow palm complete all as directed.
Supply & Planting Acciminas complete all as directed.
Supply & Planting Ficus palm complete all as directed.
Supply & Planting Golden Syprus complete all as directed.
Supply & Planting Sun Cool Palm complete all as directed.
Supply & Planting Hybycus palm complete all as directed.
Supply & Planting Agave Palm complete all as directed.
Supply & Planting Rose plant complete all as directed.
Supply Planting Alamanta palm complete all as directed.
Supply & Planting U-Forvia complete all as directed.
Supply & Planting Lescora Plant complete all as directed.
Supply & Planting Stage Palm complete all as directed.
Supply & Planting Podesperman complete all as directed.
Supply & Planting Dracenara Leaf complete all as directed.
Supply & Planting Phonic Leaf plant complete all as directed.
Supply & Planting Nullina leaf plant complete all as directed.
Supply & Planting CTC Red Leaf Plant complete all as directed.
Supply & Planting Thunia Leaf Plant complete all as directed.
Supply & Planting Thercoma Orange Leaf Plant complete all as directed.
Supply & Planting Arcaria Leaf Plant complete all as directed.
Supply & Planting Lantena (Border Plants) complete all as directed.
S & F Brass Water Splinkler complete all as directed.
M&L for item No. 31 to 63 include for watering, manure, pesticides as required and maintenance of the grass / plants during the maintenance period of 6months from the date of completion of the project. During the maintenance period water will not be supplied by the MES, contractor has to make his own arrangements complete all as directed.
One light point controlled by one way modular switch.
One fan point controlled by one way modular switch.
One Exhaust fan point controlled by one 5 Amps one-way modular.
One light point controlled by two 2-way switches.
S&F LED tube light fitting. 20 W, 230v . complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed.
S&F suspension mounting 40W LED luminaire CCT 5700 K, CRI>=80 system lumen output with primary suspension kit and main cable, high brightness SMD LEDs complete with all accessories including driver pre-wired complete all as specified.
S&F flat panel 2X2 surface mounting 42W LED luminaryCCT 5700 K CRI>= 80 system lumen output 4650 lm for glare free symmetric soft light with high brightness SMD LEDs complete with all accessories including driver pre-wired complete all as specified.
S&F, flat panel 2x2, recess mounting LED luminaire power consumption not more then 42W ,system lumens output 4250 or above, CCT 5700K, suitable for Armstrong/Grid ceiling with high brightness SMD LEDs complete with all accessories including driver pre-wired complete all as specified.
Supply & fix light duty,metallic exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and directed.
Supply & fix heavy duty exhaust fans AC single phase 230/ 240 V of size 450 mm sweep with louver complete all as specified and directed.
Supply and fix BLDC BEE 5 star ceiling fans 230V, 1200mm sweep ,power consumption less then or equal 32W and including down rod upto 2 meter, complete all as specified and directed.
S&F Sheet metal enclosure for pre wired distribution board double door, vertical type powder coated triple pole & Neutral 4 way with out MCCB, three phase 415 volt with 200 Amps rated tinned electrolytic copper bus bar with neutral link complete all as specified and directed.
S&F Sheet metal enclosure for pre wired distribution board double door, vertical type powder coated triple pole & Neutral 8 way with out MCCB, three phase 415 volt with 200 Amps rated tinned electrolytic copper bus bar with neutral link complete all as specified and directed.
S&F MCB SPN 40 Amp, 240 volts 10 KA complete all as specified and directed.
S&F MCB SP 6-32 Amps, 240 volts 10 KA complete all as specified and directed.
M&L Wiring for circuit / submain wiring alongwith earth wire with 4 runs of 2.5 Sqmm for Phase and neutral and 2 runs of 2.5 Sqmm for earth FRLS PVC insulated copper conductor, single core multi stranded cable in 25mm dia PVC conduit and conduit accessories concealed as required complete all as specified and directed. Note: Four runs of 2.5 Sqmm cable, two runs of 2.5 Sqmm earth conductor and one run of PVC conduit shall be measured as one run.
M&L Wiring for circuit / submain wiring alongwith earth wire with 2 runs of 4 Sqmm for Phase and neutral and 1 run of 4 Sqmm for earth FRLS PVC insulated copper conductor, single core multi stranded cable in 25mm dia PVC conduit and conduit accessories concealed as required complete all as specified and directed. Note: Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of PVC conduit shall be measured as one run.
M&L Wiring for circuit / submain wiring alongwith earth wire with 2 runs of 6 Sqmm for Phase and neutral and 1 run of 6 Sqmm for earth FRLS PVC insulated copper conductor, single core multi stranded cable in 25mm dia PVC conduit and conduit accessories concealed as required complete all as specified and directed. Note: Two runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit shall be measured as one run.
M&L Wiring for circuit / submain wiring alongwith earth wire with 4 runs of 10 Sqmm for Phase and neutral and 2 runs of 10 Sqmm for earth FRLS PVC insulated copper conductor, single core multi stranded cable in 25mm dia PVC conduit and conduit accessories concealed as required complete all as specified and directed. Note: Four runs of 10 Sqmm cable, 2 runs of 10 Sqmm earth conductor and one run of PVC conduit shall be measured as one run.
M&L Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, GI light grade 15mm dia pipe for earth lead protection including necessary excavation earth work in any type of soil and getting out and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and as directed.
S&F LED Security Light made up of pressure diecast aluminium housing with arcylic cover as diffuser with IP66 protection made impact resistance of IK07 with 10KV inbuilt surge protection device of capacity 48W complete all as specified and directed.
S&F bracket suitable for street light fitting made out of 40mm dia GI tubing light grade 1.5m long bent to shape, fixed with necessary nuts bolts and clamps of size 32X6mm complete all as Specified and directed.
S&F Timelite DB including 32 Amps 3 pole MCB, ML2 power contactor and programable digital time switch suitable for street light control all as speciefied and directed. NOTE- Make of DB, MCB power contactor and time switch should be same.
S&F sheet metal enclosure for pre wired distribution board double door, powder coated VTPN, 8 way with out MCCB, three phase 415 volt with 200 Amps rated tinned electrolytic copper bus bar with neutral link, flushed in wall, complete all as specified and directed.
EXTERNAL WATER SUPPLY M & L Cutting GI pipe of any size and reducing to required length before laying and insertion of 'T's of 50X50X50mm and branches for 50 mm all as specified and as directed.
M&L for brick Masonry valve chamber of internal dimentions of 750 x 750 x 750 mm including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 fundation, brick work in CM (1:6) plastering internal surface 15mm thick in CM (1:4) PCC (1:3:6) type C1 coping 50 x 50 x6 mm angle iron 6 mm thick MS Plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as shown on drawing and as specified
M&L, Cutting the existing roads to a width of 60cm and 75cm in depth for laying GI pipe of 80 to 100 mm bore including returning, filling in and top surface of road 15cm shall be made good with PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed.
LIGHTNING PROTECTION Supply and fixing epoxy spacer insulator with one GI stud bolt with nut and washer with necessary drilling for bolt hole for holding / fixing roof conductor / down conductor of lightning conductor at any height complete all as specified and as directed.
M & L Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth strip 32X6 mm by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore , wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI light grade 40mm dia pipe for earth lead protection including necessary excavation earth work in any type of soil including getting out and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking up of old GI earth plate all as specified and directed.
LIFT Supply, installation, testing & commissioning gear less, machine room less lift electrically operated with microprocessor, based controls, complete with power driven automatic stainless steel (SS) sliding car doors and landing doors having stainless steel (SS) car enclosure suitable to carry Goods lifts (1000 kgs) at speed of 1.0 M/Sec to serve upto 3 floors (G+2) with all standard features mentioned below and human interface device (HID) and along with (ARD) automatic rescue device complete all as per following technical specification. (a) Type & capacity : elevator for goods lift (1000 kgs). (b) Type of drive : V3F. (c) Speed: 1.0 meter per second. (d) Travel: Suitable for goods travel for Ground floor, 1st floor & 2nd floor (three floors, three stops, three levels and for opening on same side) approx 9 Meter travel. (e) Shaft size: 2400mm Width x 2200mm Depth (f) Power supply:415/440 Volts, three phase 50 Hz AC. (g) Car diamension's width 1600 mm, depth 1600 mm and clear opening width 1400 mm. (h) Car Enclosure: Stainless steel panel, SS flase ceiling handrall SS. (j) Flooring : Chequered plate - Aluminium (k) Electric light: LED light fitting. (l) Fan : Pressure fan, 400 mm sweep-01 No. (m) Car Entrance: Automatic certre opening in stainless steel hairline finish. (n) Clear Opening height: 2000mm
SPECIAL EARTHING Material and Labour for maintenance free chemical earthing consists of earth electrode CU (copper) bonded steel rod 17.2 mm dia 3000mm length and 250 microns back filled with 30 Kg carbon based campound including 17.2 mm tin coated brass clamps both sides, The pit shall be installed with a man hole with top cover including laying of 25x3mm copper strip from the earth pit to panel/equipment up to 7.5m using 40mm GI Pipe buried in ground from earth pit to building equipment earth strip including earth Resistance measurment and provide test report all as per direction of Engg-in-Charge. Note:- The earth resistance value for each location should be lesss than 2 Ohms and to measured and calibrated with earth resistance megger and same has to be certified by concerned user department.
Supply & Fix Earth continuity conductor with 20x3mm copper strip fixed to wall on batten or recess or chases with necessay epoxy insulators or buried in ground or drawn in conduit/pipe/wall or any ther indicated situation for loop earthing etc complete all as specified and as directed.
Supply and fixing epoxy spacer insulator with one GI stud bolt with nut and washer with necessary drilling for bolt hole for holding / fixing earth continuity conductor complete all as specified and directed.
WATER COOLERS Supply, installation, commis-sioning of Water cooler partially stainless steel, electric driven single phase having approx storage of 80 ltr and nominal cooling capacity 40 Ltr per hour all as specified and directed.
Supply and fix voltage stablizer for automatic operation single phase naturally cooled indoor type & designed for input variation between 170 to 250V which output voltage stablizer 230V with accuracy of 2.5% and capacity 2KVA.
DG SET Supply, installing, testing and commissioning manufacturer/ OEM asembled silent type (DG) diesel engine genarating set with AMF panel having prime power rating of 320 KVA/ 256 Kilo watt at power factor of 0.8 lagging , 415 Volts, AC, 3 phase four wire, 50HZ , 1500 RPM , alternator directly coupled with diesel engine mounted on, common base frame complete with Acoustic enclosure with inbuilt fuel tank, fuel line and accessories PCC foundation work as per manufacturers instructions anti vibration pads, OEM recommended standrd panel showing standard parametrs of engine and alternator, exhaust pipe & other standard aceessories and comprising the following: - (a) ENGINE (Prime Mover): Diesel Engine four stroke inline six cylinders, liquid / water cooled turbo charged, after cooled modal confirming to ISO 8528-5 G2 class performance with capacity of 10% over loading for one hour in 12 hour duration, capacity of giving adequate BHP not less than 399 at 1500 RPM to drive alternator capable of delivering minimum 320 KVA(256 KW) at outdoor atmospheric conditions at Hyderabad and capable of taking 10% over load for one hour after 12 hours of continuous operation , complete with the standard fititings fixtures as per manufacture and following accessories as specified and directed.
(b)(i)Fly wheel housing and fly wheel (ii) Air cleaner dry type replaceable paper element type restriction indictori (iii) electronic governor (iv) Dual fuel filter including water separator , fuel pump, fuel injection pump (FIP) and injectors (v) Radiator, Fan & water pump assembly (vi) proced lubrication - Pump, Lub oil filter & Lub oil cooler. (vii) Exhaust silencer and necessary stack as per CPCB norms with necessary support and fundation suitable per Hyderabad weather Cost of stack , support and foundation deemed to be included. (viii) First fill lub oil and coolant and diesel during commisision and testing (ix) exhaust gas driven turbo charge Alternator: Alternator shall be self excited. Self regulated, brush less for 320 KVA / 256 KW at the speed of 1500 RPM at 415 Volts , 50 Hz, three phase four wire system with advance electronic voltage regulator to ensure high voltage accuracy with + 1% with class H insulation and IP 23 ingress protection, directly coupled with engine through fexible couplng and confirming BS - 2613/SI-4722 complete-1 No. (c) BASE FRAME & FOUNDATION : Common base frame for engine & alternator made from structural steel chanel. PCC foundation including adequate number of suitable anti-vibration pads all as per the recommendeation of the manufacturer
(d) ELECTRICAL STARTING SYSTEM: Electric starting system 24 Volts DC with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 180AH capacity each as recommended by OEM/ manufacturer including interconnecting cables/leads with terminals complete with starting/stopping switch, voltmeter etc - 01 Set. (e) ACOUSTIC ENCLOSURE: Corrosion resistant, acoustic and weather proof enclosure with durable industrial locking system on doors with gasket made of high quality EPDM material with arrangement for fresh air intake for cooling of engine & alternator, extraction and discharging of hot air to the atmosphere, made out of CRCA sheet with 9 tank pre treatment process and UV resistant powder coating and high quality noise absorbant & fire retardant grade acoustic insulation materials (rockwool) complying to IS 8183 well suitable for 320 KVA DG set to reduce noise level to 75 db (A) measured at 1.00, meter distance @ 75% load under field condition confirming to CPCB II norms. Enclosure will have inbuilt base frame mounted inside fuel tank of capacity min 750 Liters fabricated out of 14 SWG MS sheet mounted inside the enclosure along with fuel piping from tank to engine capacity as recommended by OEM with drain valve, air vent, inlet, outlet, connection and suitable exhaust pipe duly cladded with glass wool and covered with aluminum sheet inside the encloser and exhaust trail pipe with muffle complete all as per manufacture 's design.
Supply and Fixing of GI Strip 32 x 6 mm buried in ground 150 mm below normal ground level including connecting up with earth electrode plates of earthing on both ends with GI nuts, bolts & washers, in addition to welding and also including all excavation, earth work and returning filling-in, leveling, compacting, etc complete all as specified and directed.
TELEPHONE AND LAN S&F Modular Telephone RJ 11 Socket, 1 module in a concealed flush box in wall including connected items complete all as specified and as directed.
S&F Modular LAN RJ 45 Socket, 1 module in a concealed flush box including connected items complete all as specified and as directed.
M&L for 25 mm dia PVC conduit medium grade and conduit accessories, concealed in walls complete all as specified and directed.
AIR CONDITIONING Supply, install, test and commissioning BEE,5 star rating, split type capacity of 2 TR air conditioning unit (inverter type) complete with driver motor copper winding with air cooled condenser with all assessories varied speed and dual rotary compressor including fixing the out door units as per manufacture recomendation and fixing of room (high wall) unit on wall provoding and making interconnection including refregrant piping with nitryle rubber insulation and control cable from indoor to outdoor up to a distance of 3 meter power cabling (max 3 meter from isolator/encloser) to unit ,first recharging of refrigrant gas incliding cordless remote , drain pipe of 25mm dia for connecting drain line from indoor unit to maximum of 3.0 meters to nearest drain point complete as required capacity of 2TR all as specified and directed by eng-in-charge.
Supply and fix voltage stablizer for automatic operation single phase naturally cooled indoor type & designed for input variation between 170 to 250V which output voltage stablizer 230V with accuracy of 2.5% and capacity 5KVA.
Supply and fix copper pipe size of 12.70mm (1/2”) and 6.35mm(1/4”) including tubular heat/ cold resistant rubber foam type insulation complete all as specified and as directed.
FIRE FIGHTING AND FIRE ALARM SYSTEM Supply and fix fire hydrant stand post 80 mm dia with single flanged end with provision of double outlet conforming to IS 908.
M&L for cutting existing MS pipe line of 150mm dia and inserting of Tee 150 x 150 x 100mm including jointing and earthwork in any type soil complete all as specifie and directed.
Supply and fix Branch pipe Nozzles Stainless Steel of size 63 mm dia complete all as IS standard
supply and fix Cast iron Air release valves with single air outlets, confirming to IS 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mmm dia.
Supply and fix auto dialing system for addressible system consist of storage capacity of 10 to 15 telephone Nos programmable type, complete all as specified and as directed
Supply and fix PVC 2 core 1.5 sqmm FRLSH armoured copper cable as per IS drawn through and including 25mm PVC conduit medium grade and conduit accessories concealed to wall/ roof/ false ceiling/ floors complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply, installation, testing and commissioning of 11 KV, 3-Phase, 50 HZ, 400 Amps, 250 MVA, 13.1 KA Vacuum Circuit Breaker, extensible as per site condition indoor type with motorized and manual spring charging facility breaking capacity 13.1 KA for 3 Seconds, SCADA compatible, having pad lock, provision for earth switch complete with all necessary accessories and standard fittings (e.g. Relays, C.T.s, P.T.s, Power pack, spring charging motor, trip coil, ammeter, voltmeter, indication lamps etc) all as specified, required at site and as directed Make: comprising of followings: - (i) 11 KV, 3 Phase, 50 HZ, 400 Amps, 13.1 KA, VCB having short circuit current withstand capacity not less than 13.1 KA for 3 Seconds, having manual and automatic charging mechanism, by DC/Universal motor suitable for 110 Volts/230 Volts AC/DC or as per OEM's recommendations, shunt trip coil, indication lamp, on off switch padlock, provision for earth switch etc complete all as specified and directed. (ii) Double Core and Double Ratio type dry type current transformers (C.Ts) of ratio 50/25/%+5 Amps, Suitable for 11 KV, 3 Phase, 50 HZ, having 15 VA burden or as per OEM's recommendation with 0.5 Class accuracy for metering and %P10 accuracy for protection-01 Set of three. (iii) Dry type 11 KV/110 Volts potential transformer(P.T.s) Suitable for 11 KV, 3 Phase, 50 HZ, connected to bus bar Class-1 accuracy of 100 VA burden or as per OEM's recommendations complete all as specified and directed-01 Set
Supply, installation, testing and commissioning of factory made LT Panel board manufactured by CPRI Approved firm made out of CRCA sheet 2.0 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V including suitable capacity of Busbar complete with powder coating, necessary internal electric connection as required and provision of the following: - a) Suitable capacity of Aluminium Bus bar, TPN full for phase and neutral with colour code PVC sleeves. - 01 Job
Incoming: (Main Panel) a) ACB 2500 Amps, Microprocessor Release , Electrical Draw Out type, 4 Pole, 50 KA rating 415 Volts, 50 Hz. Outgoing: a) ACB 630 Amps, Microprocessor Release , Electrical Draw Out type, 4 Pole, 415 Volts, 50 Hz, 50 KA- 5 Nos c) MCCB 63 Amps, adjustable type Thermal Magnetic, 4 Pole, 415 Volts, 50 Hz, 16 kA - 01 d) 40 MCB Amps, TPN - 1No (e) Timer 10 KV Nos-01 (f) Power contactor AC3 rating ML-3 - Nos - 01 g) LED RYB indicating lamps – 01 set h) LED Ammeter and voltmeter witn necessary CTs and display of required rating . j) Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job k) Interconnection of busbar with MCCB, , contactor with suitable size aluminium strip - 01 Job l) Provisioning of cable glands and cable lugs for all incoming and out going cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. - 1 Job
Supply, installation, testing and commissioning of APFC Panel of capacity 525 KVAR With capaciors of 450 KVAR (6x50KVAR+6X25KVAR), for future expansion without capacitors of capacity 75KVAR (1x50KVAR+1X25KVAR ), Mounting base ISMC - 75 mm auto Switch type, indoor floor mounting with 2mm thick CRCA sheet for outer frame, doors and 1.6 mm thick CRCA sheet for inner partition, provision for cable entry at bottom with 3mm thick gland plates for cable entry and interior / exterior after 7 tank process powder coated as per shade RAL7032 Siemens Gray painting complete with 1000A rated aluminium bus bar fixed on SMC insulators in 3 phase and half neutral pattern along with 1.5 Sqmm copper cables for CT wiring etc and provision of partition for switchgear complete all as specified and directed. consists of this following: - (i) MCCB 630 Amps, 4P 36KA microprocessor based fitted with extended rotory handle with over load and short circuit protection as a incomer, (ii) Ultra heavy duty capacity with 7% detuned reactors and actives hydbrid harmonic filters to have smooth functioning over UPS loads, microprocessor based 14 stage APFC relay with box type energy capacitors of 450 KVAR rating in steps of 50 KVAR -6 Nos and 25 KVAR -6 Nos. Three phase sensing of PF and control of PF in smooth manner needs to be provided. (iii) MCCB 100Amps, 3P 36 KA fitted with extended rotory handle for 50KVAR capacity - 7 Nos (iv) MCCB 63 Amps, 63 Amps 36 KA MCCB fitted with extended rotory handle for 25 KVAR capacity - 7 Nos (v) 14 Stage APFC relay along with capacity duty contractor, digital voltmeter, Ammeter and PF Meter,indicating lamps, Push button CT's for measurement and cooling arrangement with suitable exhaust fan and airfilter and any other accessories required complete all as specified and directed.
Supply, installation, testing and commissioning of Factory made LT Panel board manufactured by CPRI approved firm made out of CRCA sheet 2.0 mm thick Indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V including sitable capacity of Busbar complete with powder coating, necessary internal electric connection as required and provision of the following: - a) Suitable capacity of Aluminium Bus bar, TPN full for phase and neutral with colour code PVC sleeves. - 01 Job Incoming: (Ground Floor ) a) ACB 630 Amps, Microprocessor Release, Electrical Draw Out type, 4 Pole, 415 Volts, 50 Hz, 50 kA Outgoing: a) 125 MCCB Amps, 4 Pole, 415 Volts, 50 Hz, 25 kA - 6 No b) 63 MCCB Amps, 4 Pole, 415 Volts, 50 Hz, 16 kA - 4 No c) MCB, TPN, 40/32 Amps, 10 kA, - 01 No. d) LED RYB indicating lamps – 01 set e) LED Ammeter and voltmeter witn necessary CTs and display of required rating.
f) Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job g) Interconnection of busbar with MCCB, contactor with suitable size aluminium strip - 01 Job h) Provisioning of cable glands and cable lugs for all incoming and out going cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. - 1 Job
Supply, installation, testing and commissioning of factory made LT Panel board manufactured by CPRI approved firm made out of CRCA sheet 2.0 mm thick Indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V including sitable capacity of Busbar complete with powder coating, necessary internal electric connection as required and provision of the following: - a) Suitable capacity of Aluminium Bus bar, TPN full for phase and neutral with colour code PVC sleeves - 01 Job Incoming: (1st Floor) a) ACB 630 Amps, Microprocessor Release , Electrical Draw Out type, 4 Pole, 415 Volts, 50 Hz, 50 kA Outgoing: a) 125 MCCB Amps, 4 Pole, 415 Volts, 50 Hz, 25 kA - 7 No b) 63 MCCB Amps, 4 Pole, 415 Volts, 50 Hz, 16 kA - 6 No c) MCB, TPN, 40/32 Amps, 10 kA, - 01 No. d) LED RYB indicating lamps – 01 set e) LED Ammeter and voltmeter witn necessary CTs and display of required rating.
f) Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job g) Interconnection of busbar with MCCB, contactor with suitable size aluminium strip - 01 Job h) Provisioning of cable glands and cable lugs for all incoming and out going cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. - 1 Job
Supply, installation, testing and commissioning of Factory made LT Panel board manufactured by CPRI approved firm made out of CRCA sheet 2.0 mm thick Indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V including sitable capacity of Busbar complete with powder coating, necessary internal electric connection as required and provision of the following: - a) Suitable capacity of Aluminium Bus bar, TPN full for phase and neutral with colour code PVC sleeves. - 01 Job Incoming: (2nd Floor) a) ACB 630 Amps, Microprocessor Release , Electrical Draw Out type, 4 Pole, 415 Volts, 50 Hz, 50 kA Outgoing: a) 125 MCCB Amps, 4 Pole, 415 Volts, 50 Hz, 25 kA - 6 No b) 63 MCCB Amps, 4 Pole, 415 Volts, 50 Hz, 16 kA - 6 No c) MCB, TPN, 40/32 Amps, 10 kA, - 01 No. d) LED RYB indicating lamps – 01 set e) LED Ammeter and voltmeter witn necessary CTs and display of required rating .
f) Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job g) Interconnection of busbar with MCCB, contactor with suitable size aluminium strip - 01 Job h) Provisioning of cable glands and cable lugs for all incoming and out going cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. - 1 Job
Supply, installation, testing and commissioning of Factory made LT Panel board manufactured by CPRI approved firm made out of CRCA sheet 2.0 mm thick Indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V including sitable capacity of Busbar complete with powder coating, necessary internal electric connection as required and provision of the following: a) Suitable capacity of Aluminium Bus bar, TPN full for phase and neutral with colour code PVC sleeves. - 01 Job Incoming: (DG Set ) a) ACB 630 Amps, Microprocessor Release , Electrical Draw Out type, 4 Pole, 415 Volts, 50 Hz, 50 kA Outgoing: a) 160 MCCB Amps, Electric , 4 Pole, 415 Volts, 50 Hz, 25 kA - 2 No b) 100 MCCB Amps, Electric , 4 Pole, 415 Volts, 50 Hz, 16 kA - 1 No c) 63 MCCB Amps, Electric , 4 Pole, 415 Volts, 50 Hz, 16 kA - 6 No d) MCB, TPN, 40/32 Amps, 10 kA, - 01 No. e) LED RYB indicating lamps – 01 set
g) LED Ammeter and voltmeter witn necessary CTs and display of required rating. h) Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job j) Interconnection of busbar with MCCB, contactor with suitable size aluminium strip - 01 Job k) Provisioning of cable glands and cable lugs for all incoming and out going cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. - 1 Job
M & L Earthing complete with copper earth plate electrode 600 x 600 x 3mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to copper earth lead 20x3mm strip. by means of brass bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, GI light grade pipe 40mm dia for earth lead protection including necessary excavation earth work in any type of soil including getting out and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I.
Supply and fix, Street light control junction box 205 x 255 x 112mm upto 25Sqmm 4 core cables made out of FRP sheet moulded and arrangement for incoming and outgoing 3 phase 4 wire system with R,Y,B & N studs and control for incoming and outgoing cables with MCB SP 10Amp 230 volts with neutral link including flat iron 25 x 3mm “D” clamps, 2 No suitable to pole of any size including bolts nuts & washers etc., completed all as specified and directed. Note: The unit rate quoted shall be deemed to include for incoming & outgoing cables glands & lugs of size up to 25Sqmm 4 core.
S&F prefabricated, perforated type cable tray of size 100x80x1.5mm including cover of size 100x15x1mm for fixing cable and including arrangement as per site condition.
S&F prefabricated, perforated type cable tray of size 150x50x2.0mm thick GI sheet including MS supports/ threaded rods and anchore fasterners wherever required as per site conditions, complete all as specified and directed.
Supply and laying of 100 mm dia stainless steel pipe complete all as specified and directed.
M&L Cable route indicator marked with HT CABLE made of GI plate 3mm thick and 150mm dia duly marked with working voltage, size of cable and route , fixed on MS angle iron 40x40x6mm thick with a height of 60 cm above ground level and burried in gound grounted in P:C:C 1:2:4, type BI of size 200x200x200 mm, complete all as specified and directed
Sri Raghava Constructions Ltd
GOPAL TEKNOCON PRIVATE LIMITED
R. Wadhumal and Sons
UNITED TECHNO PROJECTS PVT LTD
M/s. P S REDDY
GOVARDHAN AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid