| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.7 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹48.9 L+₹2.1 L (4.56%)Rejected-Finance MOHANPUR PT LL HOUSE NO 00 CITY TOWN SILCHAR P O KATIRAIL P S KATIGORAH DISTRICT CACHAR PIN 788804 | CACHAR | ASSAM | 788804 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹49.5 L+₹2.7 L (5.81%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹50.0 L+₹3.2 L (6.80%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹50.0 L+₹3.2 L (6.91%)Rejected-Finance BIDHAN PALLY OODLABARI P O MANABARI P S MALBAZAR DIST JALPAIGURI | JALPAIGURI | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
27 Nov 2021, 6:00 pmClosed
GE SEVOKE ROAD
POST SALUGARA DIST JALPAIGURI
REPAIR OF STP INCLUDING OUTSOURCING OF STP AND LT PANEL UG CABLE AND OTHER CONNECTED ITEMS AT SEVOKE UNDER GE SEVOKE ROAD
2021_MES_481573_1
GE/SEV/49 OF 2021-22
Open Tender
Civil Works
Item Rate
270 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹96,000
Yes
10 Feb 2022
13 Oct 2021
29 Nov 2021
13 Oct 2021
27 Nov 2021
22 Nov 2021
13 Oct 2021 - 23 Oct 2021
Amount
M & L for dismantling defective sewage non clog type sewage pump set of 10/7.5 HP capacity at site opening suction, delivery pipe line connections,coupling nut bolts and taking out the pump set to contractors workshop for repair, machine work including refixing, assembling coupling with motor,lowering down and testing on full load for 04 hours incl providing gland packing and making the pump leak proof incl any other minor work as required at site and directed by Engineer-in-Charge. Note :-i) Spare parts replaced shall be measured and paid separately as supply only under respective item of schedule ii) Transportation charges for the motor to wksp & back are deemed to be included in rates quoted, no extra payment will be made on this account. iii) Pump set issued for repair must be returned & installed duly repaired within seven days otherwise Rs 100 per day per pump will deducted from the bill as penalty. iv) Minor items like nut/bolts, bearing grease, packing gaskets of required size to be taken in consideration while quoting the rates. No extra payment will be made on this account.
Supply only spare parts for submersible sewage pump set of capacity 10HP / 7.5HP
Impeller sets for one pump
Mechanical seal set
Oil Seal
Rubber gasket sealing
M & L for rewinding burnt coils of Induction Motor stator of following capacity with super enamelled copper winding wire as per existing size and guage to achieve the required /specified RPM including taking out old unserviceable winding ,cleaning/ repairing damaged slots , complete all as specified and as directed. Note :-i) Spare parts replaced shall be measured and paid separately as supply only under respective item of schedule. ii) Transportation charges for the motor to workshop & back are deemed to be included in rates quoted, no extra payment will be made on this account. iii) Motor issued for rewinding must be returned & installed duly repaired within seven days. (iv) Contractor will arrange testing of motor on full load for contineous eight hours. Contractor or his rep will be present on the site during the testing period. v) Minor items like nut/bolts, bearing grease, packing gaskets of required size to be taken in consideration while quoting the rates. No extra payment will be made on this account.
Supply only flat submersible cable 3 core multi stranded copper conductor of size 6 sqmm.ISI marked complete all as specified and as directed.
Supply only Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length and fixed with clamps, nuts & bolts and washers etc for holding column pipes / GI pipes of submersible pump set complete all as directed by Engr-in-Charge.
S&F in repair FASD starter FN 32 with 3 Nos 10 A fuse, star contactor MNX 9 240 V delta and main contactor MNX 12, 240V add on block 2 No, 2NC over load relay MN2 , 3-5, MPPR 300-4-11 range single phasing, over load, phase reversal, lock rotar, over voltage and under voltage relay with panel enclosure and wiring, 5 HP motor rating AC-3 duty, 415V, 50Hz, 3 phase all as specified and directed by Engr-in-Charge.
S&F in repair FASD starter FN 32 with 3 Nos 20 A fuse, star contactor MNX 9 240 V delta and main contactor MNX 12 240V add on block 2 No, 2NC over load relay MN2 , 6-10, MPPR 300-8-221 range single phasing, over load, phase reversal, lock rotar, over voltage and under voltage relay with panel enclosure and wiring, 10 HP motor rating AC-3 duty, 415V, 50Hz, 3 phase all as specified and directed by Engr-in-Charge.
M & L for blocking of incoming sewage water in sump,dewatering desilting / taking out accumulated sludge, Silt, Mud etc. from sewage collection sump and connected channels including scrapping down and cleaning internal surface of walls, Floors, Roofs, Mechanical Parts and cleaning blockage of wash out channels, pipes Drainage system etc. and removing the same to a distance not exc. 50 Metre and reopening of blockage of sump complete all as specified and as directed. Note:- Quoted rate deemed to included the followings:- (a) Diesel/ electric Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved and directed. (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge. (d) Painting of external surface should be cement baised paint
Removal of Filter media from DMF and ACF filters and reloading the same after cleaning and new media reloading complete all as specified and directed by Engineer-in- Charge.
Supply in replacement Bio media made of plastic and corrugated shape having surface area 260 sqm/cum in MBBR as directed by Engr-in-charge. Make: MM Aqua, Bharat, SIMA
Supply only quartz silica sand 32-64 grade complete all as specified and directed by Engr-in-charge.
Supply only quartz silica sand 16-32 grade complete all as specified and directed by Engr-in-charge.
Supply only quartz silica sand 8-16 grade complete all as specified and directed by Engr-in-charge.
Supply only quartz silica sand 4-8 grade complete all as specified and directed by Engr-in-charge.
Supply only activated carbon IV 1000 complete all as specified and directed by Engr-in-charge.
Material & Labour for painting to exposed CI/GI/MS pipe lines of header/suction/delivery of pumps any type/make/size including sluice valves, fittings and non return valves at water supply installations as per specified colour code after cleaning and scraping out old paint including writing/marking complete including removing and refixing the pipes after thoroughly cleaning the pipes all as specified and directed by Engineer-in-charge
S & F in repairs Dry run protection relay as per existing size complete all as specified and as directed. Cat part No CS90863 of make L&T or equivalent ABB/LEGRAND/SIEMENS/SCHNEIDER
S&F of 3 phase Digital panel volt Meter Flush Mounting 96x96mm, Accuracy Class-I, input voltage measurement range 17-520V AC (P-P), including taking out unserviceable complete all as specified and as directed.
S&F of 3 phase 5A, Digital panel ammeter Flush Mounting 96x96mm, Accuracy Class-I, CT/PT Site programmable including taking down existing unserviceable one complete all as specified and as directed.
S&F of 3 phase indicator lamp including taking down existing set complete all as specified and as directed by Engr-in-Charge
Supply, laying , jointing, welding & testing MS pipe ( Heavy duty Class 'c') including fitting as required of following sizes laid in treches or laying on floor for connecting to various STP accessories and to connect outgoing water main including taking down the unserviceable pipe all as directed by Engr-in-charge. Note:- MS flange and flange joint complete with jointing material shall deemed to be included in the unit rate of this item.
100 mm bore
80 mm bore
50 mm bore
Material and labour for CI butterfly valve of following sizes, stainless steel disc as per IS 13095 class PN-1.0 complete with nuts, bolts, washer and rubber gasket including taking out old unserviceable butterfly valve complete all as specified and directed by Engr-in-charge.
25 mm bore
80 mm bore
100 mm bore
M&L for Overhauling of air compressor coupled with blower motor 30 HP capacity Installed at Sewage treatment plant including necessary arrangement to transporting to workshop fro re-grinding of shaft , oiling ,greasing etc and replacement of wornout bolts ,nuts ,washers, silencer, belt drivers, pressure guage, air-filter, bearings, rings etc . Re-assembling the compressure with blower motor , commissioning and testing to the entire satisfaction of Engineer - in - charge .
Supply only compressure oil all as specified and directed by Engineer - in- charge .
M&L for replacement of Ball bearing of the electric motor of cap 10 -15 HP 3 phase / single phase complete all as directed. Make: SKF/TATA/NBC.
M&L for replacement of MS Shaft of the electric motor of cap 10-15 HP 440 Volts in repairs complete all as directed.
M&L for Servicing of NC Horizontal Multi staging pump including Taking out Pump from its Position by decoupling from Motor and disconnecting , degreasing bearing and display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts, Replacement of Gasket set and gland packing rope,greasing the bearing with bearing grease ,Reassembeling the Pump complete with all existing serviceable parts, Reinstall the Pump at its existing Position , couple with the Motor and connecting all suction delivery water connections and testing on completion complete all as specified by Engineer-in- Charge.
S&F in replacement motor compatible with centrifuge pump set of make: Alfa Laval Cat Part No 61195730-00 with tapar lock D28, Torque 31 NM and motor plate, IEC NX 904 including accessories with electric connection and testing complete all as specified and as directed by Engr-in-Charge.
Surface excavation in soft/ loose soil,not exceeding 15cm deep for cleaning the area by cutting the unwanted bushes/vegetation growth in and around the area of installation/around the valve pit chamber/along the pipeline routes if reqd etc all as specified and directed by Engr-in-charge.
M & L for Scraping old paint of Electric Panel (internal annd external) and Painting with two coats of synthetic enameal paint over a coat of red oxide primer including disconnecting electric connection and re-wiring without any damage of existing parts as directed by Engnr-in-Charge complete as all specified and as directed.
M&L for cement concrete 1:3:6 type C-2 (40mm graded stone aggregate) as in sub base complete all as specified and directed.
Supply and mixing of Sodium hypochloride having 10% chlorine content.
Supply and mixing of Dewatering Poly Electrolite 100 % Purity.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550mpa as in roof covering/clading to wall, fixed with self taping screws as specified complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint on newly primed steel surfaces exceeding 10cm in width or girth complete all as specified and directed.
M&L 100mm hardcore of broken stone or boulders of gauge not exceeding 63 mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100mm cement concrete PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for 100mm cement concrete PCC 1:2:4 type B-2 (40mm graded stone aggregate) as in sub base complete all as specified and directed.
S&F rolled mild steel sections any type including hollow section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates FE -290 Gde E-165 complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance n exc 50 cm and making good surface soft/loose soil complte all as specified and as dirceted.
M&L for cement concrete in foundation, filling mass concrete type-C2, 1:3:6, (40mm graded aggregate) all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out excavated material for laying/ taking out pipe line, cables, etc in soft/ loose soil complete all as specified and directed
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in each layer in soft/ loose soil complete all as specified and directed
Removing excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and as directed.
M&L for providing sand cushioning for protection of UG cable in trenches with dry sand approved quality including filling, spreading and punning down to desired thickness complete all as specified and directed. Note- Punnned thickness shall be measured.
Supply and laying burnt clay sub class B brick as cable protection all as specified and directed.
Supply and fixing GI pipe 50 mm light grade for UG cable protection with all fitting fixed to pole or laid in trenches or laid in floor/road all as directed.
Supply and fixing GI pipe 40 mm light grade for UG cable protection with all fitting fixed to pole or laid in trenches or laid in floor/road all as directed.
M & L for laying LT underground Cable, including takingdown existing u/s XLPE insulated, heavy duty armoured sheathed 1100 volts grade 10 Sq mm, 2 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete incl making necessery cable end connection all as specified and as directed.
All as per item No 53 above but 16sqmm, 4 core all as specified.
All as per item No 53 above but 25sqmm, 3.5 core all as specified.
All as per item No 53 above but 35sqmm, 3.5 core all as specified.
All as per item No 53 above but 70sqmm, 3.5 core all as specified.
All as per item No 53 above but 95sqmm, 3.5 core all as specified.
All as per item No 53 above but 120sqmm, 3.5 core all as specified.
M&L for boring holes 2mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m. (Note: Connected items like Pipes is measured and paid seperately under relevant items).
Supply and fixing thermoplastic cable junstion box with terminals having protection IP 66/67 "weather proof" for outside installation with metric knockout entry for cable of size 16 sqmm 4 core and size 155x210x92mm with terminals and provision of one MCB SP 6A complete with all pole brackets and fixing arrangements all as specified and as directed.
M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings with MCB SP in junction box, complete all as specified and directed.
S&F in repair 3 phase street light panel made of CRCA sheet IP54 with digital 24hrs timer, 65A triple pole contactor, 63A MCB triple pole and necessery complete wiring with max load 12KW of frame size 2 incl all connection and fixing arrangements on wall/floor/pole mounted of make Havells cat part no: IHXTS09120 Engr in charge.
M&L in repair for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore light grade galvanized steel tubing up to 7.5 mtr length for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete.
Taking down overhead LT ACSR conductor from directed location all as specified and directed by Engr-in-Charge.
M/S BHARAT CONSTRUCTION
M/S ASOKE KUMAR MAJUMDER
SRI SURAJIT SENGUPTA
RAJIV DEY SARKER
SAROJ DEVI AGARWAL
M/S TARAN INFRACON
M/S Banerjee construction co
M/S AJIT GARAGE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .