Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | ₹34.7 L Quoted ₹36.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹38.1 L+₹1.4 L (3.85%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹38.1 L+₹1.4 L (3.85%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹45.3 L+₹8.6 L (23.4%)Rejected-Finance D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | ₹45.3 L+₹8.6 L (23.4%) | L3 | Rejected-Finance Other than L1 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
27 Mar 2024, 6:00 pmClosed
CWE NO 2 DELHI CANTT-10
HQ CWE NO 2 DELHI CANTT-10
REPAIR / MAINT OF EXTERNAL ELECTRIFICATION, HT CABLES, VCB, TRANSFORMERS AND CONNECTED WORKS AT CABINET SECTT NBC COMPLEX UNDER GE SOUTH WEST NEW DELHI-03
2024_MES_644266_1
CWE/SW/TOKEN-38/2023-24
Limited
Electrical and Maintenance Works
Item Rate
330 days
GE SOUTH WEST NEW DELHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE SOUTH WEST NEW DELHI
₹99,000
17 May 2024
27 Feb 2024
29 Mar 2024
27 Feb 2024
27 Mar 2024
20 Mar 2024
Amount
Disconnecting HT supply and taking out defective trolley of VCB/SF6 breaker HT 11 KV, 630 Amps of any make and type and servicing of trolley of VCB by cleaning isolating contacts moving parts removing dust particles from bus bar chamber spout gear mechanism and moving parts, repair to motor charge spring mechanism tightening of nut & bolts, clamps of entire trolley components and replacement of all unserviceable spares as required and all as directed, inserting in trolley, testing commissioning and putting the supply on load with proper caliberartion complete all as specified and directed. Note:- (i) Servicing/repairs will be carried out by OEM or authorised dealer only . (ii) Spares as required for replacement will be of the same company as of existing make or as recommended by the OEM. (iii) Cost of spares shall be measured and paid separately under relevant items as "Supply only"
Supply only roller assembly suitable for HT 11 KV VCB of rating 800/630 Amps as per existing make and model complete all as specified and as directed.
Supply only rocking gear assy with pin suitable for HT 11 KV VCB of rating 800/630 Amps as per existing make and model complete all as specified and as directed.
Supply only bell crank assy with rack suitable for HT 11 KV VCB of rating 800/630 Amps as per existing make and model complete all as specified and as directed.
Supply only spring guide assy suitable for HT 11 KV VCB of rating 800/630 Amps as per existing make and model complete all as specified and as directed.
Supply only operating link assy with spring suitable for HT 11 KV VCB of rating 800/630 Amps as per existing make and model complete all as specified and as directed.
Supply only Closing coil assembly as per existing make and model complete all as specified and as directed.
Supply only tripping coil assembly 24 Volts DC as per existing make and model complete all as specified and as directed.
Supply only push trip assy suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only release coil assy suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only tulip contact & spring suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only primary isolating contact assy suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only fixed plug contact assy suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only FRP tie bar suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only Guide bracket assy suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only close release lever bearing assy suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only close prop roller lever assy suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only L-link assy suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only crank lever stop pin suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only close release lever stop pin suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only reset spring for crank lever suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only pin for rocker arm suitable for HT 11 KV VCB of rating 630 Amps as per existing make and model complete all as specified and as directed.
Supply only vacuum interrupter bottle type (VG2) suitable for HT VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only driving pin for indication suitable for HT VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only plug &socket board assy suitable for HT VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only coil mech complete for O/L shunt trip or E/L trip suitable for HT VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only in reverse trip falcrum pin suitable for HT VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only epoxy housing body suitable for HT VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only grommet suitable for HT VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only shroud suitable for HT VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only drive insulator assy with nyloc nut & washer suitable for HT VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only breaker bushing suitable for HT VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only ratchet wheel assy suitable for HT VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only motor charge mechanism which include ratchet wheel assy, charging pawl set, handle block assy, essentric drive and bearing with pin suitable for HT VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only limit switch suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only charging motor button suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only mechanical castle interlock assembly with key suitable for HT 11 KV VCB of rating 800/630 Amps as per existing make and model complete all as specified and as directed. (Make-AREVA)
Supply only raising and lowering handle suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only emergency charging handle for motor mechanism suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only rectifier monoblock suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only busbar support insulator suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only thermostat for space heater suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only space heater suitable for HT 11KV VCB chamber as per existing make and model complete all as specified and as directed.
Supply control motor 110V /220V AC/DC suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified and as directed.
Supply only RC spout assy with plug shutter, adapters complete suitable for HT 11KV VCB 630 Amps as per existing make and model complete all as specified and as directed. Note for item no 1.01 to 1.44:- Fixing charges of materials from item no 1.01 to 1.44 are included in quoted rate of item no 1.00. No additional charges will be levied on department.
Disconnecting HT supply and taking out PT 11KV/ 110V and CT having ratio of 400-200/5 + 515 suitable for HT 11 KV of any make, servicing by cleaning the parts, removing dust particles by using high speed blower, tightening nut bolts of all the components of PT/CT and bus bar chamber and replacement of all unserviceable spares as required, testing commissioning and putting the supply on load (including maintain the load equally on all phases), caliberating all the relays and testing for full load to work efficiently complete all as specified and directed. Note:- (i) Servicing/repairs shall be carried out by OEM's authorised dealer only. (ii) Spares as required for replacement shall be of the same company as of existing make or as recommended by the OEM. (iii) Cost of spares shall be measured and paid separately under relevant items as "Supply only".
Supply only neoprene rubber cap for PT bushing suitable for HT 11KV as per existing make and model complete all as specified and as directed.
Supply only PT spout for RC plug-in chamber suitable for HT 11KV as per existing make and model complete all as specified and as directed.
Supply only PT plug-in chamber with fittings suitable for HT 11KV as per existing make and model complete all as specified and as directed.
Supply only HT fuse for primary side of PT suitable for HT 11KV as per existing make and model complete all as specified and as directed.
Supply only LT fuse for secondary side of PT suitable for HT 11KV as per existing make and model complete all as specified and as directed.
Supply only current transformer resin cast copper wound double core 400-200/5 +5 Amp HT 11 KV having connectors for internal wiring with 15VA burden class complete all as specified and as directed.
Supply only copper strip connector with proper insulation ( heat shrink sleev/ tube) for CT with nut & bolts suitable for HT 11 KV complete all as specified and as directed. Note for item no 2.01 to 2.07:- Fixing charges of materials from item no 2.01 to 2.07 is included in quoted rate of item no 2.00. No additional charges will be levied on department.
S&F in replacement LED indicator lamp suitable for operating at 110 V AC for RYB as per existing make and model complete all as specified and as directed.
S&F in repairs insulating mat of size 2m x 1m x 2.5 mm thick suitable for HT installations complete all as spaecified and as directed.
S&F anolog type winding temp. indicator with complete fitting suitable for transformer of 11/.433KV as per existing make and model complete all as specified and as directed.
S&F anolog type oil temp. indicator with complete fitting suitable for transformer of 11/.433KV as per existing make and model complete all as specified and as directed.
Preparation of old painted surfaces by brushing/cleaning stain, greasy spots with thinner outside cover of bus riser & supports and spray painting with two coat of synthetic super enamelled paint to match with existing colour complete all as specified and as directed.
M&L for attending major breakdown on HT lines, UG cables including replacement of insulators/ conductors and laying of temporary cables etc. Note:- (i) The contactor shall immediately attend breakdown on short notice as & when required with T&P and transport on receipt of information in required to breakdown on the direction of Engr-in-charge. (ii) In case contractor fails to attend and rectify the fault within 6 hrs after intimation by department by any means, he will liable to bear the recovery @ Rs 2000/- per hour. After intimation of 24 hours, department will rectify the fault through other agency on contractor risk and cost and double amount should be recovered from contractor's dues.
S&F in repair Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 185 sq. mm, 3 core complete all as specified and as directed.
All as per item No 11.00 here-in-before but 120 sqmm.
S&F in replacement of marshalling box including 03 Nos PT-100 Sensors for the distribution transformer 11/0.433 KV indoor dry type of capacity 1600 KVA complete testing complete all as specified and as directed.
M & L for Chemical earthing with copper earth plate 900mm x 600mm x 5mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper earthstrip 32x6mm earthing electrode as per CPRI drawing 76mm 3 Mtr long tested on 52.kA, yield strength 329, tensile strength 426, Elongation Bend / Flattering. Filled with highly conductive compound which increase the life of earthing electrode by means of bolts, nuts, check nuts and washers all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. Earthing electrode filled with highly conductive compound which increase the life. Composition of chemical filled in electrode water solubility, acid solubility. Grain size 100mesh, along with BFC Compound non toxic, non reactive, non explosive and non corrosive, including earthing pit and chamber cover complete all as specified and as directed.
S&F in repairs of DDC panel with all necessary spares for installation on 1No. HT panel having 8 breakers at Cabinet Secretariat Building. The said DDC panel must be capable of acquiring the data from various relays/ meters/ breakers/hard-points, etc., conditioning data for transmitting, transferring data through DDC panel to the server/ LED screen as per direction given by Engr-in-Charge. Also, the unit should be able to perform bidirectional communication for future use.Must have monitoring and control (along with automation logic capability) for inputs/ outputs for 1 No. HT having 48 Digital inputs. Shall also be monitoring DC supply. Contractors shall consider at least 48 DIs . Along with RS485 and TCP interfaces for multifunction meters and relays (minimum 3 points per relay) The system should be mounted in a panel of size 400mm x 800mm x 300mm (minimum) fabricated from 1.6mm thick CRCA sheet and must be powder coated. It shall be installed at outdoor site and, and shall be consisting of following:
S&F in repair multifunction meters with RS485 for mounting on 1 No. of HT panels (replacing analog ampere meters) using existing current transformers. The meter shall be of acc cl 1.0 and shall be able to record V, A, KW, KWh, PF, F. In addition, All meters shall also be able to record THD (current and voltage) with all wiring cabling, cutting of cabinets, etccomplete all as specified and as directed.
Reprogramming, Testing and Commissioning of all building management software screens, Annual Reporting Modules, Alerts and Alarms as follows: 1. Reprogramming and development of schedulars to ensure that local jobs are not down; and to kickstart the same. Development of site-based scheduling algorithms for the same. 2. The module shall be self programmable with training and support. Programming, configuration and customisation of the Smart Platform with respect to the water/ Chiller/ DG Modules as per actual site conditions and requirement of the engineer. Creation of Day wise Reports for :- (i) Run hours of HT VCB's panels (ii) HT VCB's controlling operation failures (iii) Active/Return status of each equipment with date and time. (iv). Configuring notifications, alerts and alarms as per preset logic. (v). Consumption Patterns - Daily, Weekly, Monthly and Annual reports for the following must be provided: 1. HT VCB's 1a. Grid supply availability. Periodic flow and level in the tanks 2. HT VCB'S ON/ OFF Any other reports upto 40 numbers shall be provided as deem fit by Engineer-in-Charge. The engine is to be build on existing Building Management System all as specified and as directed.
M&L in replacement for laying RS 485 Communication cable, two pairs stranded copper, (7*32) tinned copper conductors, polyethylene insulation, twister pairs, aluminium/Polyster 100% coverage, Tinned copper braid shield 90% coverage, 24 AWG strained tinned copper drain wire, armoured , PVC jacket with the following specifications: (i) Outer jacket : Polyvinyl Chloride, 0.34 in (ii) Conductor DCR: 24 Ω/1000ft (iii) Nominal outer shleid DCR: 2.2 Ω/100ft (iv) Nominal capacitance conductor to conductor: 12.8µF/ft (v) Nominal capacitance conductor to other conductor to shield: 23µF/ft (vi) Nominal characterstics impedence: 120 Ω (vii) Frequency : 1 Mhz (viii) Nominal insertion loss: 0.6 DB/100m
M&L in replacement for laying High-Performance CAT-6 Rated LAN cable - The RJ 45 cord with 24 AWG CCA wire provides universal connectivity for LAN network components upto 10 Gbps Speed, male to male ,bandwidth tested up to 550 MHz. Required Steel/PVC conduit. Including conduit and all accessories to mount/fix the cable, complete all as specified and directed.
M&L in replacement for laying 2 Core 1.5 Sqmm multistrand copper cable PVC insulated, laid up together PVC inner sheathed, GI wire braided, flexible armouring, overall PVC sheathed, steel braided cables as required complete all as specified and directed. (Note: Rates include Power cables to be laid as specified with GI/PVC pipe protection whereever deemed necessary)
S&F in repairs ground 10 Core 1.5 Sqmm PVC insulated & PVC Copper armored cable with heavy duty PVC Saddles 60 cm apart complete all as specified and as directed.
Reprogramming, Testing and Commissioning of all building management software screens, Annual Reporting Modules, Alerts and Alarms as follows: 1. Programming and development of schedulars to ensure that local jobs are not down; and to kickstart the same. Development of site-based scheduling algorithms for the same. 2. Reports as per MES requirements to multiple mailboxes. The module shall be self programmable with training and support. Programming, configuration and customisation of the Smart Platform with respect to the water/ Chiller/ DG Modules as per actual site conditions and requirement of the engineer. Creation of Day wise Reports for :- (i) Run hours of DG's (ii) Grid supply availability. (iii) DG's controlling & operation failures. (iv) Active/Return status of each equipment with date and time. (v). Configuring notifications, alerts and alarms as per preset logic. (vi). Consumption Patterns - Daily, Weekly, Monthly and Annual reports for the following must be provided: (vii). DG's KW and Start/ Stop Any other reports upto 40 numbers shall be provided as deem fit by Engineer-in-Charge. The engine is to be build on existing Building Management System all as specified and as directed by Engr -in-Charge.
S&F in replacement maintence free rechargeable battery 160/180 AH 12 Volts for DG set including all connected accessories complete all as specified and directed.
M&L for Preparation of old painted inner and outer surfaces of indoor/out door HT panels, spray painting the same with two coat of synthetic enamel paint grey (or as per direction givrn by Engr-in-Charge) and a coat of red oxide primer to achive smooth finish including writing of Machine No. complete all as specified and as directed.
S&F in replacement (at site/workshop), Porcelain Transformer bushing on HT (11KV) side, including brass stems conical bush and gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity 1600 KVA and re-connecting electrically and mechanically, testing complete all as specified and directed. Note:- The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil, opening of top cover by unscrewing nut, bolts washers and suitable size pad type bus bar almuminium and nut bolt washers etc.
Supply only in replacement electric rubber hand gloves suitable for 11 KV complete all as specified and as directed.
Supply only in replacement electric rubber shoes suitable for 11 KV complete all as specified and as directed.
Supply only in replacement electric Air blower heavy duty 620W to 700W, for cleaning of dust partical inside VCB/ACB complete all as specified and as directed.
S&F in replacement of Impluse Emergency First aid kit box with basic medicine like Band Aid strips of min 20 Nos, Anteseptic cream, Cotton, Surgical tape 1 inch, non sterial gauge swabs, Hydrogen peroxide bottle, medical spirit bottle complete all as specified and directed.
Testing and re-setting and checking connection of control cable from transformer tap changer to panel of auto tap changer relay up to 2 MVA transformer through authorised service engineer, Checking of instruments function and taking corrective action for improvement if found improper, Tap changer panel l/breakers and tranformer control panel complete for its proper functioning complete all as specified and as directed.
M&L for maintenance servicing , calibration of existing APFC panel with and including repair/replacement of unsv of capacitor with existing size complete upto 500KVAR APFC Panel all as directed.
Supply and fix in repairs of Alarm annucator 8 window of existing make and model suitable for 11/0.4KV HT breaker complete all specified and directed.
M&L for fabricating feeder distribution layout board on ACP sheet of thickness 3mm and size as required at site designing the layout as per the sketch provided by GE using ecosolvent print including lamination and fixing to the wall using necessary fixing nuts, bolts and spares as required at site. The job includes removing of old layout board from its position complete all as specified and directed.
Material and Labour for cutting existing BT road/PCC of size 45cm x 60cm for taking out/laying of underground cable and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 200mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bags and removing debris to a distance not less than 50m complete all as specified and directed.
Supply and laying GI tubing 80 mm dia, light grade for cable protection at road crossing/on poles and tubing sealed at both ends after laying the cables including taking out old GI tubing complete all as directed.
Servicing of capacitor bank 560 KVAR, 12 KV, 3 Ph Dry Type Series Reactor and checking of capacitance of capacitor including control & power wiring, barrel fuses cleaning of spare parts including testing of relay & contactor, tightening of nuts/bolts etc after taking shutdown as per electrical safety norms complete all as directed Note: Spares costing upto Rs.1500.00 shall be deemed to be included the in quoted rate.
Supply only manometer suitable for SF6 breaker as per existing make and model complete all as specified and as directed.
Supply only operating lever for the disconnector and switch disconnector suitable for SF6 breaker as per existing make and model complete all as specified and as directed.
Supply only operating lever for the earthing switch suitable for SF6 breaker as per existing make and model complete all as specified and as directed.
Supply only torroidal type current transformer 400-200/1 +5% Amp, 5P10, HT 11 KV having connectors for internal wiring with burden class 1VA as per existing make and model complete all as specified and as directed. Note for item no 38.01 to 38.04:- Fixing charges of materials from item no 38.01 to 38.04 is included in quoted rate of item no 38.00 No additional charges will be levied on department.
M&L for Dehydration including filteration and cleaning of transformer oil by dehydration machine of 11/0.433 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filteration complete all as specified and directed. Note:- Deficient quantity of Transformer oil required for top up shall be measured and paid separately under relevant items of this Schedule here-in-after as supply only.
Supply only transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in transformer or for topping up as required and directed.
S&F in replacement Thermometer/ heat sensor of transformer upto capacity 1600 KVA complete all as specified and directed.
SANJEEV ENTERPRISES
Pradeep Bros
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .