Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹63.0 LAccepted-AOC | ₹63.0 L Quoted ₹65.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹66.0 L+₹35,828.90 (0.55%)Rejected-Finance | ₹66.0 L+₹35,828.90 (0.55%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹72.2 L+₹6.5 L (9.95%)Rejected-Finance | ₹72.2 L+₹6.5 L (9.95%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹72.7 L+₹7.0 L (10.6%)Rejected-Finance 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | ₹72.7 L+₹7.0 L (10.6%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹74.6 L+₹8.9 L (13.5%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹74.6 L+₹8.9 L (13.5%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹97.9 L
EMD Value
₹2.0 L
Closing Date
17 Dec 2024, 6:00 pmClosed
GE SATWARI
GE SATWARI
REPAIR/REPLACEMENT OF LT OH LINE TO UG LT CABLE AND ALLIED E/M WORKS AT SATWARI CANTT AREA AND RAIPUR SATWARI AREA UNDER GE SATWARI
2024_MES_685701_1
GEJM-59/2024-25
Open Tender
Electrical and Maintenance Works
Works
270 days
GE SATWARI
Class C Cat b(i)
9 documents required · 9 mandatory
₹1,000
GE SATWARI
₹2.0 L
Yes
14 Jan 2025
26 Nov 2024
19 Dec 2024
26 Nov 2024
17 Dec 2024
10 Dec 2024
Amount
Disconnecting, dismantling and taking down carefully ACSR conductor of any size from LT/HT poles complete all as specified and directed..
Dismantling and taking down old cross arms, clamps, braces, brackets of MS channel or angle section including nut bolts washers etc from poles complete all as specified and directed.
Dimantling and taking down old Insulators of any types complete all as specified and directied.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including providing new HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed .
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including providing new HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including providing new HDPE pipe of 80 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed .
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including providing new HDPE pipe of 50 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed .
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 m in depth for foundation, laying of underground cable etc or n. exc 10 sqm on plan and n. exc 1.5 m in depth for foundations of poles, struts, stays etc. & getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated approved soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directied.
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made un-reinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 2 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 35 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 50 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 70 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 95 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 120 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 150 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 185 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 240 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 10 Sqmm, 2 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium solid conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm 2 core nominal cross section in service connection complete all as specified and directed.
Supply and laying / fixing , GI pipe, light grade, 80mm bore for cable protection fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement complete all as specified and directed.
Supply and laying / fixing , GI pipe, light grade, 40mm bore for cable protection fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement complete all as specified and directed.
M&L for complete earthing with galvanised mild steel earth plate electrode of size 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1, precast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh ,15mm dia light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specifieds and directed ..
M&L for factory made bus bar chamber of size 750 x 600 x 500 mm, outdoor type, pedestal type, powder coated, made out of 3.15 mm thick CRCA sheet duly powder coated, dust and vermin proof complete with openable shutter in front & rear having proper locking arrangement duly mounted on angle iron frame 50x50x6 mm including necessary earth work & PCC in foundation in all respect including 250 Amp 415 Volt, 4 pole MCCB with thermal magnetic protection as incommer control and aluminium bus bar mounted on insulator, 500 Amps, 4 pole, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable with phase indicator lamps (R, Y. B) – 01 Set. complete all as specified and directed.
M&L for factory made bus bar chamber of size 750 x 600 x 500 mm, outdoor type, pedestal type, powder coated, made out of 3.15 mm thick CRCA sheet duly powder coated, dust and vermin proof complete with openable shutter in front & rear having proper locking arrangement duly mounted on angle iron frame 50x50x6 mm including necessary earth work & PCC in foundation in all respect including aluminium bus bar mounted on insulator, 300 Amps, 4 pole, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable with phase indicator lamps (R, Y. B) – 01 Set. complete all as specified and directed.
Supply & fix thermoplastic polystyrene polycarbonate junction box of size 210 X 155 X 92 mm, shock proof with IP 66 protection with suitable connector for three phase loop in loop out branch out and vibration proof connection and fixing on LT/HT poles using MS clamp made out of 25mm x 3mm MS flat (02 Nos) and nuts & bolts of required size complete all as specified and directed .
M&L in repair for complete earthing with galvanised mild steel earth plate electrode of size 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr below ground level connected to GI strip 25x4mm by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1, precast RCC cover slab using reinfocement with XPM weighing not less than 4.00 kg/Sqm with suitable handle made of 12mm round bar including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh ,40mm dia light grade galvanised steel tubing upto 7.5 m length for drawing earth strip protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed.
M&L for cutting of bituminous road / floor for laying of pipe / cables, not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including refilling the material ,watering, well ramming / compacting and making good with 100 mm thick PCC 1:2:4,type B-1 complete all as specified and directed.
Durga Electricals (BID ID -3190821)
vivek and co (BID ID -3191495)
Prakash Trading Corporation (BID ID -3190968)
kailu construction co (BID ID -3190196)
SATISH AND CO (BID ID -3190692)
M/S S K Electricals Regd (BID ID -3191270)
Ashoka Engineers (BID ID -3190695)
Standard engineers (BID ID -3191691)
V K Sales and Construction Co (BID ID -3186410)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .