Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC 252 22 NEAR SOCITY BUS STAND INDRA COLONY PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC BEING LOWEST BIDDEER | |
| 2 | L2₹8.3 L+₹32,638 (4.11%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹8.5 L+₹57,286 (7.21%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹8.7 L+₹72,867 (9.17%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹9.0 L+₹1.0 L (13.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
12 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR REPLACEMENT OF INTERNAL ELETRIFICATION WORKS INCLUDING CONNECTED ACCESSORIES AT DOU LSRC ASC BN ZONAL WORKSHOP AND TRANSIST CAMP AREA UNDER AGE EM I OF GE 865 EWS
2022_MES_557446_1
865/EWS(NIT-80)/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹40,000
Yes
26 Nov 2022
13 Oct 2022
19 Nov 2022
13 Oct 2022
12 Nov 2022
28 Oct 2022
Amount
S&F in replacement of 1100 V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of pvc tape and over all pvc sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core cable flat of stranded multistrand conductor size 10 sqmm 2 core complete all as specified and directed by Engr-in-Charge
S&F in replacement of 1100 V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of pvc tape and over all pvc sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core cable flat of stranded multistrand conductor size 16 sqmm 2 core complete all as specified and directed by Engr-in-Charge
Taking down carefuly sheet metal enclosure for DBs double door & with socket plug to and MCBs single pole and neutralenclosure complete at site and making good distrubed surfaces of walls, floors/ceilings complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/Aluminium point wiring (Light, Fan, Socket or power) complete fitting such as switches, ceiling, regulator, sockets etc removing materials to be store for keeping in safe custody for re-use at site and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engr-in-Charge.
M&L for point wiring for one light point or fan point controlled by one light/exhaust fan controlled by one way switch with PVC insulated copper conductor stranded cable of size 1.5 sqmm and including PVC casing/caping terminated in existing sunk CI/pressed steel terminal boxes for fixing and 1.5 sqmm PVC insulated copper wire as earth wire connected to earth wire connected to earth lead and 3.0mm thick plastic laminated sheet cover all as specified and directed by Engr-in-Charge.
All as per item No 5.00 here-in-before but 1.5 Sqmm forone bell piont controlled by one bell push including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the independent board complete all as specified and directed by Engr-in-Charge.
All as per item No 5.00 here-in-before but 1.5 Sqmm for one 3 pin 6 Amps, 230 volts socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the same board complete all as specified and directed by Engr-in-Charge.
All as per item No 5.00 here-in-before but 1.5 Sqmm for one 3 pin 6 Amps socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the independent board complete all as specified and directed by Engr-in-Charge.
All as per item No 5.00 here-in-before, but using cable 4 Sqmm complete all as specified and directed by Engr-in-Charge.
S&F in replacement of lamp holder PVC/Poly corbonate type insulated body with back plate suitable for batten fittings as specified and directed by Engr-in-Charge.
S&F in replacement of Switch piano flush button single pole 6 Amps 230 volts one way complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Switch socket combination outlet 5 pin 6 Amps flush type 230 volt complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Switch socket combination outlet multi purpose 5 pin 6 Amps flush type 230 volt complete all as specified and directed by Engr-in-Charge.
S&F for ceiling rose, surface backlite three terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement of bell push single pole 230 volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of of Bell ding-dong single pole complete all as specified and directed by Engr-inCharge.
S&F in replacement of modular switch 1 way 6 Amps 230 volt,1 module complete all as specified and directed by Engr-in-Charge.
S&F in replacement of modular switch socket combination outlet 5 pin 6 Amps flush type 230 volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of modular switch socket combination outlet multi purpose 5 pin 6 Amps flush type 230 volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of modular white cover plate with frame of 03 module suitable for 5 pin 6 Amps and 16 Amps 230 volt complete all as specified and directed by Engr-in-Charge.
S&F in replacement of modular white cover plate with frame of 06 module suitable for 5 pin 6 Amps and 16 Amps 230 volt complete all as specified and directed by Engr-in-Charge.
S&F in replacement of modular metal flush box 03 module suitable for 5 pin 6 Amps and 16 Amps230 volt complete all as specified and directed by Engr-in-Charge.
S&F in replacement of modular metal flush box 06 module suitable for 5 pin 6 Amps and 16 Amps230 volt complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB distribution board Double door, single pole, regal grey, sheet metal enclosure, SPN 240 volts 4 way with 200 Amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc . Make: As per PS.
S&F in replacement of MCB distribution board Double door, single pole, regal grey, sheet metal enclosure, SPN 240 volts 8 way with 200 Amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc . Make: As per PS.
S&F in replacement of MCB distribution board Double door, regal grey, single pole, sheet metal enclosure, SPN 240 volts 12 way with 200 Amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc . Make: As per PS.
S&F in replacement of MCB distribution board Double door, three pole, regal grey, sheet metal enclosure, SPN 240 volts 4 way with 200 Amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc . Make: As per PS.
S&F in replacement of MCB SPN 63 Amps, 'C' series, 240 V A/C complete all as specified and as directed by Engineer-in-Charge. Make: As per PS.
S&F in replacement of MCB SPN 40 Amps, 'C' series, 240 V A/C complete all as specified and as directed by Engineer-in-Charge. Make: As per PS.
S&F in replacement of MCB SPN 6 to 32 Amps, 'C' series, 230 V A/C complete all as specified and as directed by Engineer-in-Charge. Make: As per PS.
S&F in replacement of MCB SPN 40 to 100 Amps, 'C' series, 230 V A/C complete all as specified and as directed by Engineer-in-Charge. Make: As per PS.
S&F in replacement of LED luminaire 600mm x 600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge. Make : As per PS.
S&F in replacement round shape 12 watt, 220 volt, AC, recessed type with high efficiency PMMA diffuser, soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
S&F in replacement round shape 6 watt, 220 volt, AC, recessed type with high efficiency PMMA diffuser, soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED light fittings 1x9/1x10W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. Make : As per PS.
S&F in replacement of LED light fittings 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. Make : As per PS.
S&F in replacement of Air circulator PVC body, AC single phase 230 volts of size 300 mm sweep with blades and frame and louvers complete all as specified and as directed by Engr-in-Charge. Make : As per PS.
S&F in replacement of Air circulator PVC body, AC single phase 230 volts of size 250 mm sweep with blades and frame and louvers complete all as specified and as directed by Engr-in-Charge. Make : As per PS.
S&F in replacement of heating element suitable for water storage heater vertical type 220/240 Volts, AC, 1500 watts and making connections and testing complete all as specified and directed by Engr-in-Charge. Make Orison/Pearl or equivalent make as per PS.
S&F in replacement of heavy duty PVC connections armoured type with brass union 15 mm size of length 600 mm, long complete all as specified and diected by Engr-in-Charge. Make: Prayag/Polytuf/Supreme or equivalent make in PS.
S&F in replacement of thermostate switch for water heater suitable for Racold type 220/240 V, 50 Hz, AC, termperature range 32-88 degree centigrade ISI marked complete all as specified and directed by Engr-in-Charge.
Material and labour for earthing in replacement complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including GI wire of size 4 mm dia by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point, etc, incluidng taking down of old u/s earthing set complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. Any additional length shall be adjusted through deviation order. (ii) Item includes the cost of 7.5 m GI earth lead. Any additional in length shall be adjusted through deviation order ( For Main DBs ) (iii) Item includes the cost of Charcoal and commercial salt ( For Main DBs )
Sub main wiring in replacement with two run of 4.00 Sqmm (2x4 sqmm) single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 4.00 Sqmm (1x4sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 4 Sqmm (2x4sqmm), one run of 4 Sqmm (1x4 sqmm) cable and one metre of PVC casing caping will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY/ANCHOR/ POLYCAB
Sub main wiring in replacement with two run of 6.00 Sqmm (2x6 sqmm) single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 6.00 Sqmm (1x6sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm), one run of 6 Sqmm (1x6 sqmm) cable and one metre of PVC casing caping will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY/ANCHOR/ POLYCAB
Sub main wiring in replacement with two run of 10.00 Sqmm (2x10sqmm) single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 10.00 Sqmm (1x10sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 10 Sqmm (2x10sqmm), one run of 10 Sqmm (1x10sqmm) cable and one metre of PVC casing caping will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY /ANCHOR/ POLYCAB
S&F in replacement of sheet metal enclosure with 20 Amps 240 Volt socket plug top and MCB single pole and neutral enclosure with two pin and earth plug and socket with one single pole 20 Amps MCB complete all as specified and directed by Engr-in-Charge.
R B TRADERS
SUMEET TRADING CORPORATION
Ms Salaria Builders
M.S Sharma Enterprises
Horizon Construction Company
SONAM ANGCHOK
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .