Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.1 LAccepted-AOC | ₹2.1 L Quoted ₹1.8 L | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹1.8 L+₹2,500 (1.40%)Rejected-Finance AT BHAGA NO 5 NEAR MAHAVIR ASTHAN PO BHAGA DHANBAD | BHAGA | DHANBAD | ₹1.8 L+₹2,500 (1.40%) | L-2 | Rejected-Finance L-2 |
| 3 | Rejected-Technical WARD NO 07 DINDAYAL UPADHYAY NAGAR BASTI PARA DIPKA DISTT KORBA CG 495452 | KORBA | CHHATTISGARH | 495452 | - | - | Rejected-Technical NOT RESPONDED TO CONFIRMATORY DOCUMENT |
Tender Value
₹2.6 L
EMD Value
₹3,400
Closing Date
23 Jul 2022, 5:00 pmClosed
STAFF OFFICER CIVIL. DIPKA AREA
OFFICE OF STAFF OFFICER CIVIL, DIPKA AREA, CG 495452 PHONE 9424141319,9425279540
Providing bore hole with submersible pump beside substation near tail end of new CHP of Dipka expansion project of Dipka Area
2022_SECL_249479_1
SECL/DA/CIV/e-TENDER/22-23/62 DT 09/07/2022
Open Tender
Civil Works - Others
Item Rate
15 days
DIPKA CG
As per NIT
3 documents required · 3 mandatory
₹3,400
15 Nov 2022
12 Jul 2022
25 Jul 2022
12 Jul 2022
23 Jul 2022
13 Jul 2022
13 Jul 2022 - 20 Jul 2022
Amount
DESCRIPTION
Bore/Drilling bore well 200 mm. All kind of soil
Bore/Drilling bore well up to 90.00 Rm.Rocky state. i.e Boulder - 200 mm
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – in-charge. 150 mm nominal size dia.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Supply installation iof submersibble pump of 5HP of approved make ISI marked confirming to IS:8034-2002 and motor confirming to IS:9283-1995
Providing and fixing motor starter of L&T make for submersibble pump 10 pole AC3-415 v (9-14 Amp).
Providing and fixing 3 core flat cable copper wire 2.5 sqmm of approved ISI marked.
Supplying and fixing UPVC column pipe 40mm dia. Of prince brand or equivalent as per instruction of Engioneer-in-charge.
Providing and fixing 6 mm dia wire ropwe with PVC insluation etc complete.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on walll 15 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on walll 20 mm nominal outer dia .Pipes.
Providing and fixing brass bib cock of approved quality. 15 mm nominal bore.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Total impact of GST for the purpose of CTC
SATISH KUMAR AGRAWAL
ANAND KUMAR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .