Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.4 L+₹80,480 (5.17%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹17.4 L+₹1.8 L (11.6%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹17.8 L+₹2.2 L (14.4%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹18.1 L+₹2.5 L (16.0%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 864 EWS
GE 864 EWS, BB CANTT SRINAGAR.
REPAIR MAINTENANCE OF CERTAIN B/R ITEMS INCLUDING INTERNAL ELECTRIC SUPPLY AND MISC WORKS SERVICES TO OTM AND MD ACCN AT BB CANTT, SRINAGAR
2021_MES_496030_1
864/WS-51/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE 864 EWS BB CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹50,000
Yes
16 Mar 2022
20 Dec 2021
20 Jan 2022
20 Dec 2021
17 Jan 2022
3 Jan 2022
60 days
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for 12mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement (as backing coat to receive tiles), complete all as specified and directed.
M&L for Glazed ceramic coloured tiles in vertical surfaces of size 450mm x 300mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over backing coat, complete all as specified and directed.
M&L for Non-skid ceramic coloured tiles 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, lamp holders, regulators, switch socket outlets, light fittings etc and making good disturbed surfaces of walls with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed.
M&L for point wiring with single runs PVC insulated FRLS grade, 1100V grade cable with multistranded copper conductor of size 1.5 Sq. mm (Nominal area) (ISI Marked) drawn in and including PVC Casing capping of suitable size with all fittings and accessories including PVC flush box/ Metal flush box/ sunken box of suitable size and drawing continuous earth wire of PVC insulated FRLS grade, unsheathed stranded copper conductor of size 1.5 Sqmm(ISI Marked) terminated the box for following type of point wiring including making good disturbed of wall completed all as specified and directed..
One light fan 3 pin socket outlet 5/6 Amps/ bell point controlled by one, one way normal/modular Switch.
One 3 pin socket outlet 5/6 Amps on same board.
One 3 pin socket outlet 5/6 Ampsindependent but below the switch board on same board.
Ditto as per Item No. 8 described here-in-before but with FRLS grade, (ISI mark) PVC insulated and unsheathed two run multistranded copper conductor of size 4.0 Sqmm for one power point of 3 pin 15 Amps on independent board including FRLS grade (ISI mark), PVC insulated, unsheathed one run multi-stranded copper conductor of size 2.5 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
Supply and fix Bell push, flush type, 5/6 Amps, single pole, 230 V (ISI mark) completed all as specified and directed.
Supply and fixing ,Buzzer, ding dong, AC, 230 V, Single pole (ISI marked) completed all as specified and directed.
Supply and fix, Switch piano (ISI marked) Single pole 240 volts, flush type, one way 5Amps complete all as specified and directed.
Supply and fix socket (ISI marked), 2/3 pin and 5 Amps, flush type, 240 volts complete all as specified and as directed.
Supply and fix Switch socket combination (ISI marked), 2/3 pin and 5 Amps, flush type, 240 volts complete all as specified and as directed.
Supply and fix switch socket combination (ISI marked) 2/3 pin and 5/15 Amps, flush type, 240 volts complete all as specified and directed.
S&F stepped type fan regulator flush type complete all as specified and directed.
S&F Modular fan regulator electronmic rotary , 0-4 steps stepped type 100 watt 240 volts 50Hz hum free 2 module with modular plate and frame complete all as directed.
S&F Modular switch one way 6 Amps, one module with modular plate and frame complete all as directed.
S&F Modular switch one way 16 Amps, one module with modular plate and frame complete all as directed.
S&F Modular bell push with modular plate and frame complete all as directed.
S&F Modular socket 6A/16A 2/3 pin combined 2 module with modular plate and frame complete all as specified and directed.
S&F modular socket 6 Amps-2/3 pin combined two modules with moduler plate complete all as directed.
S&F in repair/ replacement LED light fitting fixture 20W, decorative ultra slim with co extruded channel in thermally conductive material with plastic housing, heat sink, environmental friendly energy efficient ready to use complete all as specified and directed.
S&F lamp holder, insulated body, with back plate for batten fitting with LED 7 to 9 lamp complete.
M&L for ceiling rose, 3 terminals PVC/polycarbonate, isolated body complete all as specified and directed.
S&F in repair/replacement of surface/Recess mounted LED luminaire with complete diffuser 34/36W , 2'x2', Flat Panel powder coated CRCA housing, heat sink complete all as specified and directed.
S&F in repair/replacement of 10/13.5 Watt 6000K LED Bulk head luminaries with premium quality diffuserfor glarefree light , etc complete with accessories complete all as specified and directed.
S&F in repair/replacement of round/square surface/recess mounted LED downlighter panel with complete diffuser 15/18W complete all as specified directed.
S&F in repair/replacement of round/square surface/recess mounted LED downlighter panel with complete diffuser 9/12W complete all as specified directed.
S&F in repair/ replacement LED Mirror light fitting 1 x10 W 6500K decorative ultra slim linear LED lighting fixture with extruded AL. heat sink, environmental friendly, energy efficient, complete all as specified and directed.
S&F in repair/replacement of LED Driver suitable for 40/36 watts LED 2' x 2' panel suitable for any type any make of 230 volts domestic use complete all as specified and directed.
S&F in repair/ replacement LED Driver suitable for 9/15/18 watts LED down light suitable for any type any Make LED fitting of 230 volts domestic use complete all as specified and directed.
S&F in repairs LED bulb 7 watt, B22/E27 including taking out old unserviceable one complete all as directed by Engineer -in- Charge.
S&F in repairs Candle lamp energy saving LED type 5/7 watt E27(warm type). Make : Philips/wipro/Bajaj
S&F in repairs Candle lamp energy saving LED type 3/5 watt E14(Warm type) .Make : Philips/wipro/Bajaj
S&F in repairs G-9 lamp, capacity 50/60 watt, 230 volt 50 Hz AC supply. Make : Philips/Bajaj
S&F in repair /replacement of LED security light of capacity 10 Watt 65000K flood light with IP 65 protection complete all as specified and directed.
S&F ceiling fan of 1200 mm sweap single phase 230/240 volts complete all as specified and directed. Note :- Old/ UNSV ceiling fans shall be deposited to MES store yard
Taking down old unsv vantilation fan and repair/replacement of ventilating burn out fan motor with frame made out of high quality engineering plastic, resistant to colour change with anti static properties, 250mm sweep suitable to work on 230 Volts 50 Hz AC supply of Havells or equivalent of CG/Bajaj including connecting to ceiling rose complete all as specified and directed.
S&F storage water heater 25 Litres capacity, vertical mounting, AC, 230 Volts, BEE 5 Star rating including connecting cord and plug, safety valve, nuts and bolts etc complete all as specified and directed. Note : Old/ Unsv water storage water heater and capacity shall be deposited to MES store yard.
S&F in repair/replacement of distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 4 pole 415 Volts 100 Amps rating with rupturing cap 16 KA and 12 Nos of MCB SP 63 Amps of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and directed.
Supply and fix MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed including taking down old unserviceable MCB distribution board.
Supply and fix MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed including taking down old unserviceable MCB distribution board.
Supply and fix MCCB four pole , 415 Volt, 100 Amps,16 KA , fixed thermal & magnetic setting complete all as specified and directed as in repairs.Make: Havells Cat part No - IHLASF0063 or equivalent model from make : Schnieder/GE/C&S.
Supply and fix in repair /replacement of MCCB four pole , 415 Volt, 125 Amps,16 kA , adjustable thermal & fixed magnetic setting complete all as specified and directed as in repairs .
Supply and fix MCB SPN, 240 Volts, 40 to 63 Amps, 10 kA rupturing capacity, 'C' series complete all as specified and directed including taking down old unserviceable one.
Supply and fix MCB SPN, 240 Volts, 32 Amps, 10 kA rupturing capacity, 'C' series complete all as specified and directed including taking down old unserviceable one.
Supply and fix in repair/replacement MCB SP, 240 Volt, 6-32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed.
Supply and fix in repair/replacement MCB SP, 240 Volt, 40 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed.
Supply and fix in repair/replacement MCB SP, 240 Volt, 63 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed.
M & L for sub main wiring with two runs of 6.0 Sqmm FRLS grade (ISI mark) PVC insulated, multi stranded, unsheathed copper conductor and one run of , PVC insulated ,multistranded FRLS grade (ISI mark) unsheathed copper conductor of size 6.0 Sqmm green colour as earth lead including PVC casing caping of suitable size complete all as specified and directed, including taking down old unservicable sub main wiring .
M & L Sub main wiring with two runs of 10 Sqmm FRLS grade, (ISI mark) PVC insulated, multi stranded, unsheathed, copper conductor and two runs of, PVC insulated multistranded FRLS, grade (ISI mark) unsheathed copper conductor of size 10.0 Sqmm green colour as earth lead including PVC casing capping of suitable size, complete all as specified and directed, including taking down old unservicable one.
S&F in repair/replacement Wall bracket decorative LED light fitting of capacity 9 Watt with Opal diffuser of B22 base complete all as directed. Make: Havells/ wipro/ Crompton Greaves.
S&F in repair/replacement Wall/Bed light LED light fitting of capacity 2.5watt complete all as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, with cover and handle for lifting of cover, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR 2009 part -I in repair.
Taking down carefully storage type water heater (geyser) of any capacity/make/model from its existing position after disconnecting electric and water supply connections, dismantling various parts and refixing in the same position after cleaning the inner tank including testing complete all as directed.
S&F the following new spare parts of various type/make of geysers of ISI marked components complete all as directed by the Engr-in-charge. :-
Heating element, any type 1.5/2.0KW rating capacity, with rubber washer.
Thermostat switch automatic, of 50/25 litres capacity Geyser.
PVC connection pipe, heat resistive type, 15mm bore (internal) fixed with adopters both ends complete.
Neon lamp /indicator lamp complete with holder.
Apparatus plate/syphone assy with rubber gasket including nuts, bolts and washers any type match to existing 25/50 ltrs geyser one complete.
Internal stainless steel tank of geyser 25 ltr capacity complete with syphon assembly, rubber gasket, thermostat switch, fix in outer body fill with insulated material with indicator lamp complete. The tank shall be fix as per site requirement. (The tank shall be tested at site and shall be able to withstand requisite pressure.)
Internal stainless steel tank of geyser 50 ltr capacity complete with syphon assembly, rubber gasket, thermostat switch, outer body fill with insulated material with indicator lamp complete. The tank shall be fix as per site requirement. (The tank shall be tested at site and shall be able to withstand requisite pressure.)
S&F in repair Spring loaded air release valve .
S&F in rapair of Stop cock,15mm bore, chromium plated complete all as directed by the Engr-in-charge.
M&L for Wallfastner of size 100mm long, 8mm dia with double washers grouting making good in walls with cement mortar 1:4 for fixing water heater after removing the existing unserviceable wall fastner including nuts /bolts and washers complete all as directed.
M&L for Repair of leakage/cracked inner copper/steel container of water heater by means of brazing/soldering with copper brass alloy & testing of inner shell up to the entire satisfaction of the Engr-in-Charge complete all as directed.
S&F Plug top, 3 pin , 15 Amps, (ISI marked) as in repairs complete all as specified and as directed.
Dismantling and taking out burnt winding by cutting, cleaning slouts and re-winding of AC ceiling fan motor1200mm/1400mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, threading complete all as specified and directed (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used) (ii) Motor shall be wound with machine only. (iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
S&F in repair for gun metal bush of ceiling fan complete all as specified and directed.
S&F in repair for capacitor AC 230/240 volts 2.5/3.15 mfd oil filed ISI markedcomplete all as specified and directed. Make: L&T/Havells/Epcos.
S&F in repair/replacement of PL-L 18 WLED with high efficacy suitable for existing 2G11 lamp holders complete all as specified and directed.
M/S Tajamul Ah Buchh
ZAHOOR ENGINEERING WORKS
ORISON ENTERPRISES
M/S Vijay Constructions
M/S VALLEY ENTERPRISES
M/S INVOGUE ST ENTERPRISES
M/S ATTAR BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .