EE-II KNHED PWDte.
KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata 700073
Firefighting arrangement at remaining areas in MCH, C.B and Eden building ---- SITC of FDS system at Eden building (remaining areas).
2025_WBPWD_849208_1
WBPWD/EE-II/KNHED/NIQ-07/2025 - 26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹1.6 L
OFFICE OF THE EE KNHED PWDte.
1 Aug 2025
20 May 2025
11 Jun 2025
20 May 2025
9 Jun 2025
26 May 2025
26 May 2025
Amount
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 ( VDS / UL approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Cerberus Pro / Honeywell/ Edward)
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat detector IP 42 ( VDS / UL approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. (Approved Make : Cerberus Pro / Honeywell/ Edward)
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make : Cerberus Pro / Honeywell/ Edward )
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL approved) approved. (Approved Make : Cerberus Pro / Honeywell/ Edward)
Supply, Installation, Testing & Commissioning of Addressable Monitor Modules & Transponder with necessary relay module ( VDS / UL approved ) for monitoring Flow switches / Fire exit doors / AHU/ Lift etc. with inbuilt short circuit fault isolator and minimum (04) four potential free contact with adjustable setting parameter likes of Input or output, complete in single or multiple housing with degree of protection IP 42 with flash LED indicator that conforms module is operational and integrated buzzer signaling maintenance alarm, complete as required. (Approved Make : Cerberus Pro / Honeywell/ Edward)
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make : Cerberus Pro / Honeywell/ Edward /Agni Suraksha )
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Gloster/ KEI/ Havells) through Existing 20 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. on the surface of the wall.
Supplying and fixing PVC Rigid Conduit 'FR' (Make : Precision/ Polycab, medium quality) on wall, ceiling with saddles and other accessories as required and mending good damages to building works 20mm size
S&F of MS box of suitable size surrounding the fire panel with front acrylic door on suitable support incl. necy. painting and locking arrangement as per direction of EIC.
Making necessary Autocad drawing (4 copies) of total installation and submitted to the office as per direction of EIC.
Opening, Checking, Cleaning, Testing & Re-Commissioning of existinmg field devices (Detectors, MCP,Hooter and Input/Output device) (Make : Cerberus Pro/ Honeywell) of the existing fire alarm detection system as per direction of the E.I.C. at Green building and Eden building
Re-comissioning the existing fire panel (Make : Cerberus Pro/Honeywell) after opening loops of EN54 standard, VDS Approved Microprocessor based 1 / 2 / 4 Loop Capable fire alarm control panel for checking and testing of necessary cables, display & field device for the existing Fire Detecions and Alarm system as per latest fire alarm guide line (IS2189/NBC/NFPA72) as per direction of the E.I.C at Green building and Eden building
NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) Standards, (ii) IS 2189 , (iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand.
TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done.
Terms and conditions The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Before taking up the work necessary drawing/layout should be prepared and must be approved from the appropriate authority of PWD according to the prevailing fire safety policy. After commissioning, completion certification should be obtained from same appropriate authority of PWD without which payment should not be released.
Defect Liability period 1 (One) Year from the date of commissioning
(Rate should be quotated including all taxes and duties, GST and considering the value of less cost materials.)
PERFECT IMAGE SOLUTIONS (BID ID -6529108)
Creative Projects (BID ID -6538593)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .