Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹89.6 L+₹7.7 L (9.44%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹90.2 L+₹8.3 L (10.1%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 4 | L4₹92.7 L+₹10.8 L (13.2%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 5 | L5₹93.3 L+₹11.4 L (13.9%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹85 L
EMD Value
₹1.5 L
Closing Date
22 Feb 2024, 6:00 pmClosed
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
PROVISION OF PARKING SHED FOR GDOT BUILDING AND RETRACTABLE SHED OVER SPECTATOR GALLERY FOR PARADE GROUND AT AFA HYDERABAD.
2024_MES_639012_1
86739/E8
Open Tender
Civil Works
Item Rate
180 days
GE AFA HYDERABAD
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE AFA HYDERABAD
₹1.5 L
Yes
4 Mar 2024
25 Jan 2024
24 Feb 2024
25 Jan 2024
22 Feb 2024
15 Feb 2024
25 Jan 2024 - 9 Feb 2024
Amount
SCHEDULE 'A' PART - I B/R PORTION :- Excavation in post holes (or similar holes) each not exc 0.50 Cum, getting out in hard / dense soil, and removing excavated material exc 1.50 km but not exceeding 5.0 km complete all as specified and as directed.
Demolition of cement concrete unreinforced in ground floors and pavings exceeding 15 cm thickness below or above ground level including removal of debries to a distance exc 1.5 KM but not exceeding 5 Km complete all as specified and as directed.
M&L for Plain cement concrete 1:3:6, Type C-2 mix using 40 mm graded stone aggregate as in foundations, filling and mass concrete etc complete all as specified and as directed.
S&F of Structural Steel work as in columns, posts, stanchions etc using any standard sections, hollow tubes, pipes, any made-up profile with sheets etc conforming to relevant IS, grade not less than YSt 240 including necessary welding, bolting all as specified and directed
S&F of Structural Steel work as in main and cross beams, rafters, purlins, running rails and guides, gutters etc fixed with angle cleats or other connecting plates, etc. using any standard section, hollow tubes, pipes, or any made-up sections with sheet etc., as per reagent IS, grade not less than YSt.-240 including necessary welding, bolting all as specified and directed
M&L for Rolled mild steel as in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including welding, bolting etc complete all as specified and as directed.
S & F 40 mm diaStainless Steel Heavy Duty Roller Wheel with 10 mm Groove, good wear resistance, heat resistance, low temperature strength and high mechanical properties with SS Ball Bearing including necessary fixing to frame complete all as specified and directed
M&L for Powder coated aluminium structural sections of any profie, tracks, channes, hollow tubular sections, flats etc including joining cleats for fixing etc.(minimum thickness of powder coating 50 micron) complete all as specified and as directed.
S&F for High strength tensile fabric of Sattler Atlas Type II Art 739 or equivalent with 900 gsm both side lacquer as in roof covering including wastages, necessary cutting, joining, seeming to required size with and including required accessories, fixed to steel / aluminium frame work etc as per manufacturer’s instructions complete all as specified and directed
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc crome primer using with spray gun machine complete all as specified and as directed
SCHEDULE 'A' PART - II E/M PORTION :- M&L for Sub Main wiring with two runs of 2.5 sq mm 1100 Volts grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit of suitable sizewith all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and as directed.
Note :-(i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(ii) Same size wire shall be used for phase, neutral & earth conductor
(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
(iv) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint length.
S & F DB (Distribution Board) with sheet metal enclosure 240 volts, 8 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete all as specified and as directed.
S & F MCB SPN of 240 Volts, AC, 50 Hz of capacity 6-32 Amps 10 KA complete all as specified and as directed.
S&F MCB 'C' series SP 6-32 Amps rating, 10 KA breaking capacity, 240 V, 50Hz, AC supply,complete all as specified and as directed
S&F Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and as directed.
M&L for Earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6.6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and as directed after taking down old earthing.( GI wire upto 7.5m including testing consider in this item).
M&L for earth continuity conductor fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as reqd 4.0 mm dia galvanised iron or steel wire complete all as specified and as directed.
S & F GI pipe 15 mm bore, light grade with all fittings and fixed complete to walls and ceilings or laid in floors, roads, paths etc complete all as specified and as directed.
Design, fabrication, integration and motorisation of retractable roof of span not exceeding 7.5 mtr completely and supports of guide rails, channels etc., including fixing up with suitable type electric motors not less than 1 HP capacity and suitable heavy grade reduction gears etc complete all as per manufacturer specifications including provision for manual operation on power failure / Manual operation of motor gear system complete all as specified and as directed for the following :-
(a) Clear size of shed - 7.5 m wide x 11.00 m length rolled / slided to one fixed suitable for to & from moment of entire roof.
(b) Weight of each panel maximum upto 1.0 Ton (7.5 m wide x 11 to 15 m (approx) length approximate)
(c) Total section will be slided / rolled type consisting of fabric and steel / aluminium sections
(d) Drive Assembly shall be house in fully encased weather proof box with suitable electrical induction motor of suitable type and capacity not less than 1 HP, single phase with suitable heavy grade speed reduction gear attachments - 1 Sets to main driving section with necessary chain pulleys and shafts etc.
(e) Idler assembly with timing chain drive connected to roof section of size 7.5 m x 11 to 15 m or direct gear coupling - 1 Sets for the system with main driving roof section and attached movement of subsequent roof section with slave arrangement including suitable declutching facility for manual operation.
(f) Suitable limit switches shall be provided for automatic cutoff for all driving roof sections.
(g) Suitable control panel made out of 3.15 mm thick MS box, outdoor type weather proof with MCBs of suitable rating, emergency stop switch one set for each driving roof section consisting suitable relays, power and auxiliary contactors, over load and under voltage protections and single phase preventor etc., with suitable blinkers and push button switches for forward and reverse movements, including suitable bus bars, indication lamps, interlock contactors, warnings lights etc complete.
(h) All control cable of suitable rating shall be with cable trailing / bunching arrangement with suitable cable carriers, fastners etc., as per the designed requirement.
Note :- (i) Design of gear box and Redo,rolling shutter motor should be submitted and approved by Accepting Officer prior to fabrication. (ii) Structural members like posts, beam, gutters, fabric, rollers etc will be measured and paid under relavent item of schedule. (iii) Contractor shall give functional guarantee and servicing of entire system for period of 03 years from date of completion. (iv) PSD will be released after a period of 03 years from date of completion on satisfactory performance.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m depth in soft / loose soil & getting out for laying of LT cables etc complete all as specified and as directed.
Returning filling including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / loose soil complete complete all as specified and as directed.
Removing excavated soil not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M & L for Sand covering / cushioning for underground cables for protection complete all as specified and as directed.
M&L for burnt bricks sub class 'B' laid perpendicular over & cushioning for cable protection complete all as specified and as directed.
Supply lay testing and commissioning LT UG cable, XLPE insulated armoured, heavy duty aluminium conductor multistranded, 1100 volts grade, of 10 Sqmm x 2 core cross sectional area laid in trenches / fixing on walls or passing through GI pipe including connecting up with suaitable lugs, nuts and bolts wherever required and testing complete all as specified and as directed.
Saiansh Associates
M/S VIKASHA CONSTRUCTIONS
A K BANSAL AND CO
AR CONSTRUCTIONS
Mohinder Pal and Sons
Buttar Construction Co.
bharat contrectors
PARDEEP AND CO
R D Bansal
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .