| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC 15 281 CHHILI INT ROAD GHATIYA AZAM KHAN AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹50.0 L+₹7.1 L (16.6%)Rejected-Finance T 16 1 SHETTY HOTEL OLD NAVY NAGAR COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Being other than Lowest Tenderer | |
| 3 | L3₹50.0 L+₹7.1 L (16.6%)Rejected-Finance B 13 ROOM NO 2 2 SHIVA PALM BEACH SOCIETY SECTOR4 NERUL WEST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹80 L
EMD Value
₹1.6 L
Closing Date
10 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Ng Rajesh Singh
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8942 PERIODICAL SERVICES TO CERTAIN BUILDING IN ZONE 3 AT NAVAL DOCKYARD MUMBAI UNDER AGE B R I UNDER GE NW KUNJALI
2023_MES_593809_1
8942/E8
Open Tender
Civil Works - Canal
Item Rate
270 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) KUNJALI
₹1.6 L
Yes
21 Oct 2023
8 May 2023
12 Jun 2023
15 May 2023
10 Jun 2023
22 May 2023
8 May 2023 - 15 May 2023
Amount
M&L for preparation of old surafces of walls etc and applying two coat of white wash complete all as specified
Ditto_ all as per Sl item No 1 herein before but one coat of white wash on ceiling etc complete all as specified
M&L for prepration of old plastered / decorated surfaces of walls and applying one coat of oil bound distemper over 1 or 2 mm thick wall care putty on plastered/decorated wall surfaces complete all as specified and directed.
Ditto_ all as per Sl item No 3 herein before but on ceiling etc complete all as specified
M&L for prepration of old plastered / decorated surfaces of walls & ceiling and applying one coat of plastic emulsion paint over 1 or 2 mm thick wall care putty on old plastered surfaces complete all as specified and directed.
M&L for prepration of old plastered / decorated surfaces of walls & ceiling and applying two coat of plastic emulsion paint over 1 or 2 mm thick wall care putty on old plastered surfaces complete all as specified and directed.
M&L for preparation of old painted surfaces of wood or wood based surfaces over 10 cms width or girth and applying one finishing coat of synthetic enamel paint on wooden surfaces complete all as specified and directed.
M&L for preparation of old painted surfaces of steel any description over 10 cms width or girth and applying one finishing coat of synthetic enamel paint on steel surfaces complete all as specified and directed.
Re-writing the existing letters & figures (Block, Roman, Italic or Indian) not exc 30 cm high & width complete all as specified.
M&L for preparation of old wall surfaces of any description & applying one coat of acrylic (antifungal) exterior grade paint on wall/roof including scaffolding complete all as specified and directed
S&F aluminium window, doors with shutters / frames / partitions made out of extruded powder coated aluminium sections, with sliding or openable shutters including frame & necessary joining cleats, glazing clip, powder coated aluminium snap beading, screws etc; complete and also including powder coated aluminium fittings such as cobra hinges, butt hinges, tower bolts hooks and eyes, peg syays and handles including connected items, with and including, making good to the disturbed portion with its original specification, complete all as specified and directed.
S&F in repair 3 mm thick Aluminium Composite panel cladding plain metallic of approved colour/shade to beam/column/slab in circular/rectangular shape including cutting, notching, bending to shape as required jointing with silicon gel of approved colour complete all as specified and as directed.
Hacking out old broken glass ( any thickness, size, quality or description ) from wooden or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
M&L for 4 mm thick plain glass sheets ordinary quality in squares n.exc 0.5sqm each pane fixed with rubber beading for aluminium windows/doors etc all as specified and directed.
S & F in repairs for aluminium anodised Deco grill 7.5 mm size DG-102, fixed to F/H frames, 1.5mm th, bar size 6.2mm and 7.5mm thick in required sizes complete all as specified and as directed by Engr-in-Charge.
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples. All as specified and directed.
S&F Medium density fibre board, 12 mm thick exterior grade, fixed to timber framework with screws. All as specified and directed.
Taking down chowkats or frames but n exc 1.5 sqm each but with shutters (without taking off shutters from the frame)
Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each but with shutters (without taking off shutters from the frame)
M & L for 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed.
S&F 40mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both side complete all as specified and as directed .
Taking down cement plaster on brick on stone walls etc including raking out joint, hacking for key, scrubbing down cleaning the surface with water etc complete all as specified.
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth (without using extra cement) including Sagol finish complete all as specified.
M&L for rendering 5mm thick in CM 1:3 on ceiling surface complete all as specified and as directed
M&L for rendering 20 mm thick on fair faces of brick/concrete surfaces with two coats i.e (15 mm thick backing coat in CM (1:6) and 5mm thick finishing coat in CM (1:4)) ,mixed with 3% integral water proofing compound as per manufacturers instructions, finished even and smooth without using extra cement including all safety and scaffolding complete all as specified and directed.
M & L for preparing new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of 3mm thick wall care putty on plastered surfaces complete all as specified and directed.
M&L for new or previously untreated surfaces of any description & applying two coats of acrylic (antifungal) exterior grade paint of over one coat of primer on wall/roof complete all as specified and directed
M&L for preparation of new plastered surface of ceiling and applying three coat of white wash on ceiling complete all as specified and directed.
M&L for epoxy base joint filler paint on external surfaces of walls to fill the cracks with and including resin and hardner in proportion as per manufacturers instructions including scaffolding complete all as specified and as directed Make : Pidilite / Focrac / Chemistic or equivalent
M & L for Complete removal of existing treatment of walls and applying two two coats of acrylic (antifungal) exterior grade paint of over one coat of primer on wall/roof including scaffolding complete all as specified and directed
M & L for complete removal of existing treatment on wall surfaces and applying 3mm thick Birla white wall care putty, sanding the surfaces till even and smooth finish and applying one coat of wall primer, and finally applying two coats of oil bound distemper of approval tint.
Dismantling plain or corrugated steel sheeting, any gauge or thickness incl Nainital or similar pattern roof coverings all as specified and directed.
M&L in repairs for Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws/J hook and including scaffolding upto any height. complete all as specified and directed by EIC.
M&L for Pre-painted galvalume aluminum zinc coated GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Taking down plaster for removal of vegetation to free growth etc on external surface of walls at any height etc by taking all necessary precaution including digging out roots of vegetation and filling holes with PCC (1:2:4) type B1 using (20mm garded stone aggregate) after application of suitable chemical using "break manufactured by M/s Denocil Company to avoid regrowth of the vegetation and removing the debris to a distance not.exc 50 metre complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
S&F in repairs 160 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, ceilings or in floor etc with and including fixing clips bends elbow, shoes bends etc (Note :- Measurement shall be taken along the centre line of the pipes) complete all as specified and as directed.
S&F in repairs 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floor including fixing clips, bends, elbows, shoes etc complete all as specified and as directed.
S &F in repairs 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/floor complete all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets.
M&L for false ceiling made out of 600 x 600 x 4 to 6 mm thick ceiling board/tiles deep panel suspensor system made out of powder coated GI sheet main tee of size 23.50 x 40 x 0.63 mm and cross tee of size 23.50x23.50x0.63 mm and angle size 19x19x0.63 mm including 3 mm GI wire for suspending bolts necessary washers nut/cleats/pin hook etc for securing frame work to ceiling to the snap grid including provn of necessary holes/cutting for providing light/far as required including making necessary recesses/projected pattern complete all as spoecified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing ) and rabbish of the premises.
M&L for French polishing on surfaces of any description , width or girth including cleaning and preparing the surface including a coat of wood filler and applying one or more coats on old wooden surfaces.
Supply only integral water proofing compound
M&L for applying 3mm thick one coat of wall care putty on walls / ceilings etc complete all as specified and as directed.
M & L for errection & dismantling of MS tubuler double scaffolding (H frame) upto height of 30m &with necessary brazing ,provision of necessary safety equipment to the skilled workers to carry out the work and covering with green cloths for carring out external face work of walls all as directed by Engineer -in-charge.
M&L for preparation and applied on coat of indigo paint on Chequerred tiles/Interlocking paver blocks etc. All as specified and directed.
Shetty Construction Co
Anil Industrial Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .