Loading…
Loading…
Tender Value
₹2.9 Cr
EMD Value
₹2.9 L
Closing Date
13 Feb 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
TENDER
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
The definition for similar nature of work will be "The tenderer should have satisfactorily executed and completed the work as mentioned below Electrical work for General Services i.e. Power Supply System (upto and including 33 KV voltage) or Air-Conditioning or Water Coolers or Air coolers/ Desert Coolers (This does not included OHE, PSI words for Electric Traction Distribution): The definition for similar nature of' work will be - "The tenderer should have satisfactorily executed and completed any work as mentioned below: 1.Electrification of service building or Staff quarters or Offices or Road and Colony Lighting or Circulating Area Lighting or Washing Pits or Sheds or Workshops or UTS/PRS or UPS or Battery charging facilities or Pre-cooling facilities or platforms and Yards etc. 2.Erection and Commissioning of LT, HT upto 33KV Overhead Lines oe Electrical Sub-station or LT/HT UG power cables. 3.Annual Electrical Maintenance contract of Service building or staff quarters or Electrical sub-station or DG set or Train lighting and/ or Air conditioning coaches excluding RMPU units of AC Coaches. 4.Erection and commissioning of any type and capacity of Electrical Pumping set. 5.Electrification of ON Grid connected or Off-Grid connected solar power plant. 6.Electrification of advance Energy metering system or Smart Energy metering system or Prepaid Energy meters. 7.Erection and commissioning or AMC/CMC of Window/Split ACs/Water Coolers/ Refrigerators/Ductable package system of air conditioning/Centralized Air Cooling unit/ Centralized air conditioning unit or hiring of desert coolers/ Air coolers. 8.Any above work or combination of (1) to (7) above, The above work must have been carried out in any of the following organization: (a)Central Government Department or State Government
10 conditions · 6 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Goods & Services Tax (GST) registration certificate copy should be attached
The Tender/Firm must have valid Class-A Electrical Contractor License (ECL) and copy of license must be uploaded in IREPS site during bid. In case Tenderers submitted with ECL issued in the name other Firms/Tenderers will be summarily rejected. In case the ECL is not valid on the date of opening of tender, details of renewal should be submitted.
In case of Sole Proprietorship Concern firm has to submit Affidavit certifying the sole Proprietorship of the firm. This affidavit shall be notarized. Or In case of a Partnership Firm, Firm has to submit (a) Notary certified copy of the Partnership Deed. (b) A copy of power of Attorney firm has to submit (duly registered as per prevailing Law) in favour of an individual to tender for the work, sign the agreement etc., and create liability against the Firm. Or In case Tenderer is a Company registered under Companies Act-2013. The tenderer shall submit: (a)The copies of MOA (Memorandum of Association)/AOA (Articles of Association) of the company.(b) A copy of Certificate of Incorporation. (c) A copy of authorization/ Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of company and create liability against the company. Or In case Tenderer is LLP (Limited Liability Partnership); If the tender is submitted on behalf of a LLP registered under LLP Act-2008, the Tenderer shall submit along with tender: (a) A copy of LLP Agreement (b) A copy of Certificate of Incorporation (c) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. Or In case of a tenderer is registered Society and Registered trust. The tenderer shall submit: (a) A copy of certificate of registration. (b) A copy of Memorandum of Association of Society/Trust Deed (c)A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the society/ Trust.
Contractor has to submit Annual Contractual Turnover Data for the Previous 3-4 Years (Contractual Payment only) as per Annexure-VIB
The tenderers shall submit a copy of New Annexure-V(A).This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc
Certificate of information regarding employment/partnership etc. of retired railway employees with the tenderer as per Annexure- R
Electrical (G) portion of work for -(i) Augmentation of water treatment plant to improve the quality of water at BMY settlement.(ii)Construction of store godown for SMM/PP yard Bhilai. (iii) Improvement of various facilities including casualty & canteen at DRH Raipur. (iv) Provision of facilities at stations for differently abled persons(Divyangjans) and passenger with reduced mobility at stations of Raipur Division. (v)Replacement of 10 unit Type-I with Type-II staff quarters in lieu of condemned quarters in lieu of condemned quarter at Zone-I BMY colony. (vi)Provision of covered shed for sick attention near west cabin BSPC end and other infrastructural works at PP Yard Bhilai[(A.)Provision of earthing pit and earthing of proposed portal lights and existing all welding plants, welding terminals, socket points and improvement of welding facility for entire PP yard. (B.) Provision of covered shed, pathway with welding facility and lighting arrangement along side the pit line near to west cabin BSPC end. (C.) Improvement for quick scrap disposal and improvement and development of training aid. (D.)Security of live link line from spreading of steel turning and boring dumping at STB site generated from wheel lathe ](vii) Improvement of street lights of colonies over Raipur Division.
SrDEE-G-R-OTP-25-26-35~SECR
SrDEE-G-R-OTP-25-26-35
Open
Works - General
12 Months
Raipur, Chhattisgarh
₹0
₹2.9 L
13 Feb 2026
22 Jan 2026
30 Jan 2026
216 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,43,42,614.6 | ||
| — | 1.00 | — | — | ||
| Rate for supply,transporting,installation & testing of outdoor Transformer of 11/0.415 KV,500KVA capacity Transformer. | — | — | — | 8,58,981 | |
| — | 1.00 | — | — | ||
| Rate for supply and installation APFC Panel 90 KVAR. | — | — | — | 1,09,355 | |
| — | 1706.00 | — | — | ||
| Supply of Angle, channel, clamp, GI wire & Fabrication as per requirement. | — | — | — | 1,56,952 | |
| — | 1.00 | — | — | ||
| Rate for supply of LT control panel consists of 2x800A ACB for two incoming and 2X400A MCCB breaking capacity 65KA ,3x200A 4PMCCB 50KA breaking capacity , 3X100A 4PMCCB 50KA breaking capacity , for outgoing complete with busbar , HRC fuse as back up & metering arrangement | — | — | — | 4,88,171 | |
| — | 1.00 | — | — | ||
| Rate for supply of floor mounted LT Control Pannel consist with 2x400A 4P MCCB 50kA breaking capacity for incoming, 4nos.4P 250A 4P MCCB, 4 NOS.4P 125 A MCCB,4x63A 4P MCCB,4nos.32A TPN MCB, 2Nos. 25A SP MCB, 2x16A SP MCB for outgoing complete with three phase busbar distribution system and backup HRC fuse, &Metering arrangement and indication etc. | — | — | — | 3,43,963 | |
| — | 50.00 | — | — | ||
| 4 Core 2.5 Sq mm Copper Armoured Cable | — | — | — | 6,800 | |
| — | 24500.00 | — | — | ||
| Supply of semi circular RCC pipe. | — | — | — | 19,60,000 | |
| — | 270.00 | — | — | ||
| Rate for supply of circular RCC Pipe 150 mm inside dia, 30 mm thickness. | — | — | — | 53,730 | |
| — | 25.00 | — | — | ||
| Supply of 8 SWG GI wire for earthing | — | — | — | 1,725 | |
| — | 1000.00 | — | — | ||
| supply, testing, fixing & commissioning of GI perforated type cable tray made out of 2.0mm thick sheet in standard length of 2.5mtr. Duly hot dip galvanized (as per IS 2629 & IS 4759) including coupler plate with suitable GI nut, bolt & washer of 250mm W x75mm H including erection the same with PF shelter structure by bracketing. | — | — | — | 7,26,000 | |
| — | 28.00 | — | — | ||
| Rate for supply of 25W street light/flood light with complete fitting accessories | — | — | — | 30,492 | |
| — | 30.00 | — | — | ||
| Supply of 60watt(appx.) LED based flood light | — | — | — | 60,180 | |
| — | 10.00 | — | — | ||
| Supply of 5 meter single arm SST pole. | — | — | — | 21,350 | |
| — | 121.00 | — | — | ||
| Rate for supply of IP-65, IK07 thermoplastic pole mounting Junction Box 200x160x98MM (approx.) size with connecting terminals & two nos. 20 amp HRC fuse as per details | — | — | — | 2,43,452 | |
| — | 1.00 | — | — | ||
| Supply of Astronomical Timer For Street Light Control | — | — | — | 30,635 | |
| — | 50.00 | — | — | ||
| Supply of Class-A GI Pipe 80 mm dia. | — | — | — | 47,600 | |
| — | 225.00 | — | — | ||
| Supply of Class-A GI Pipe 40mm dia. | — | — | — | 1,09,350 | |
| — | 60.00 | — | — | ||
| Supply and commissioning of earth continuity GI strip 50x6 MM. | — | — | — | 15,120 | |
| — | 15.00 | — | — | ||
| Rate for supply of high speed air circulator 600mm,1440rpm, with all accessories. | — | — | — | 93,795 | |
| — | 56.00 | — | — | ||
| Supply of Exhaust fan 300 mm including all accesories. | — | — | — | 99,288 | |
| — | 150.00 | — | — | ||
| Supply of 4 feet, 20 watt(apprx) cool white LED tube light fitting. | — | — | — | 48,000 | |
| — | 52.00 | — | — | ||
| Supply of energy efficient ceiling fan 1200 mm sweep complete. | — | — | — | 1,43,572 | |
| — | 82.00 | — | — | ||
| Rate for supply of electronic step regulator for fan . | — | — | — | 35,588 | |
| — | 200.00 | — | — | ||
| 4 Core x 6 SQ. MM 1100 V Copper/ XLPE/ Armoured Cable. | — | — | — | 60,000 | |
| — | 2.00 | — | — | ||
| Rate for supply of wall mounted 4-waymetallic sub-distribution board with 1 No. 63A TPNMCB, 06 nos 32A SPMCB, busbar, neutral and earthing arrangement etc. | — | — | — | 62,200 | |
| — | 30.00 | — | — | ||
| Supply of 100 watt cool white LED floodlight fitting. | — | — | — | 89,340 | |
| — | 40.00 | — | — | ||
| Rate for supply of 200 watt LED flood/street light with fittings . | — | — | — | 2,08,960 | |
| — | 295.00 | — | — | ||
| Rate for supply of 50-60W street light/flood light with complete fitting accessories. | — | — | — | 5,91,770 | |
| — | 45.00 | — | — | ||
| Rate for supply of 5-6 meter single/double arm octagonal pole. | — | — | — | 3,64,410 | |
| — | 1000.00 | — | — | ||
| Supply of 25 mm pvc pipe. | — | — | — | 29,480 | |
| — | 1.00 | — | — | ||
| Rate for supply of LT control panel consists of 2x200A4P MCCB for incoming and2X100A 4P MCCB,6x63A TPN MCB,2x32A TPN MCB,2x20A DP MCB for outgoing complete with busbar , HRC fuse as back up & metering arrangement. | — | — | — | 79,939 | |
| — | 1.00 | — | — | ||
| Supply of 3 phase 5 h.p 5 star rated submersible pump with suitable control panel & all accessories suitable for 90 mtr head & 2.5 LPS discharge | — | — | — | 27,400 | |
| — | 2.00 | — | — | ||
| Supply of 5HP 3-phase starters control panel for submersible pump with all accessories. | — | — | — | 8,882 | |
| — | 100.00 | — | — | ||
| Supply of 3 core, 6 sqmm submersible copper flat cable confirming to IS. | — | — | — | 22,500 | |
| — | 2.00 | — | — | ||
| Supply of 3 phase 5 h.p rated mono block pump with suitable control panel & all accessories . | — | — | — | 50,188 | |
| — | 1.00 | — | — | ||
| Supply of wall mounted metallic sub-distribution board with 02x100A 4 P MCCB , 6x63A TPN MCB, 6x32A DP MCB, 6x32A DP MCB bus-bar and neutral link arrangement etc | — | — | — | 17,319 | |
| — | 1.00 | — | — | ||
| supply of wall mounted 8-waymetallic sub distribution board with 01no 63ATPNMCB, 6nos16A SPMCB ,busbar and neutral link arrangement etc..as per details in annexure-A | — | — | — | 20,530 | |
| — | 1800.00 | — | — | ||
| LED signages & name board. | — | — | — | 55,11,600 | |
| — | 180.00 | — | — | ||
| 25 mm junction box & bend for PVC pipe. | — | — | — | 6,994.8 | |
| — | 1800.00 | — | — | ||
| 2.5sq mm wire | — | — | — | 45,000 | |
| — | 40.00 | — | — | ||
| Rate for supply of wall mounted 4-way metallic sub-distribution board with04nos 250V,16A SP MCB ,busbar, neutral and earthing arrangement etc. | — | — | — | 65,284.8 | |
| — | 40.00 | — | — | ||
| Supply of 7 watt coolwhite LED lamp. | — | — | — | 4,000 | |
| — | 10.00 | — | — | ||
| Rate for supply of Digital single phase energy meter with enclosure. | — | — | — | 88,000 | |
| — | 10.00 | — | — | ||
| Supply of DP, 32 Amps, ELCB. | — | — | — | 32,770 | |
| — | 10.00 | — | — | ||
| Rate for supply of 16amps SPN MCB. | — | — | — | 8,210 | |
| — | 1.00 | — | — | ||
| Supply of Metallic Pillar Box consisting of One No. 100A TPMCCB,10KA as incoming & 12Nos. 32A SP MCB as outgoing with Bus Bar , Backup fuses & neutral link including locking arrangement. | — | — | — | 19,166 | |
| — | 90.00 | — | — | ||
| Supply of welding / Battery charging terminal consisting with two copper terminals including connection arrangement etc. | — | — | — | 1,26,720 | |
| — | 2.00 | — | — | ||
| Rate for supply of floor mounted LT Control Panel consist with 2x400A 4P MCCB50kA breaking capacity forincoming,2nos.4P 200A 4PMCCB 50KA breaking capacity, 04NOS. 4P 100 A,4nos.63A TPN MCB, 4nos.32A TPN MCB for outgoing complete with three phase busbar distribution system and backup HRC fuse, & Metering arrangement and indication etc. | — | — | — | 9,76,344 | |
| — | 10.00 | — | — | ||
| Supply of 9 watt coolwhite LED lamp. | — | — | — | 930 | |
| — | 10.00 | — | — | ||
| Supply of 100-120 watt coolwhite LED floodlight fitting. | — | — | — | 29,780 | |
| — | 10.00 | — | — | ||
| Rate for supply of 4-7.5 meter single/double arm octagonal Pole. | — | — | — | 91,920 | |
| — | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderForm__.pdf
ATTACHMENT
Annexure-VIB.pdf
ATTACHMENT
IRGCC_April-2022.pdf
ATTACHMENT
DetailTech.Spec.Annexure-A__.pdf
ATTACHMENT
Additionalspecialconditionofcontract__.pdf
ATTACHMENT
Annexure-R.pdf
ATTACHMENT
Annexure-ZSignagesforAmritBharatStations_compressed.pdf
ATTACHMENT
IRGCCWorksACS1-10_.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .