Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC | L1 | Accepted-AOC Lowest BIdder | |
| 2 | L2₹32.6 L+₹1.0 L (3.17%)Rejected-Finance 20 A 2ND FLOOR BLOCK C RAJEEV NAGAR BEGUMPUR DELHI 110086 | NORTH WEST | DELHI | 110086 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹34.0 L+₹2.4 L (7.48%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹34.2 L+₹2.6 L (8.25%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹35.3 L+₹3.7 L (11.7%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
30 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NASIRABAD
GE NASIRABAD 305601 (RAJ)
PROVN OF 16 X TOILET ALONGWITH TANK IN ASC TK TPTR TYPE C
2023_MES_592027_1
8322/E8
Open Tender
Civil Works
Item Rate
183 days
NASIRABAD
AS PER NIT
6 documents required · 6 mandatory
₹500
GE NASIRABAD
₹78,000
Yes
26 Jun 2023
28 Apr 2023
1 Jun 2023
28 Apr 2023
30 May 2023
17 May 2023
28 Apr 2023 - 6 May 2023
Amount
Surface dressing n exc 15 cm deep in soft/loose soil complete, all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Removel of surplus soil to a distance n exc 50m and depositing where directed at a level n exc 1.5m above from the starting point complete all as specified and directed.
Returning, filling in, including spreading levelling watering and well ramming in layer not exc. 25 thick complete all as specified and directed.
M&L for PCC 1:4:8 type D-2, with 40 mm graded stone aggregate as in foundation and mass concrete complete all as specified and directed.
M & L for brocken stone boulders Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified.
M & L for Non-skid Ceramic coloured tiles 7 to 8 mm thick ( square /Rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured in white or coloured cement to match with tile laid over and including screed bed or bedding layer of 15 mm thick in CM (1:6), over 25 mm thick PCC type 1:2:4 type B-0 using 12.5mm graded stone, complete all as specified and directed.
M&L for glazed ceramic coloured tiles 7 to 8mm thick, area of tile exc 0.11 sqm but n.exc 0.18 sqm, on vertical surfaces of wall such as skirting/ dados ect set and jonted in neat cement slurry and pointed in white cement to match the shade the tiles over and including 10mm thick screed plaster on stone/brick masonry walls in CM 1:4 complete all as specified and directed.
M&L for walling random rubble masonary uncoursed well bonded bedded and solidly hearted and built in cement mortar 1:6 etc complete all as specified and directed.
M&L for brick work with fly ash modular bricks,straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with fly ash modular bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
M & L for rendering 15mm thick in cement plaster 1:6 on brick masonry (internal) surfaces finished fair and even and smooth (without using exta cement), complete all as specified and directed.
M & L for rendering 15mm thick in CM 1:4 (mixed with water proofing compound) on brick masonry (external) surfaces finished fair and smooth (without using exta cement), complete all as specified and directed. (WPC will be measured and paid separately).
M&L for rendering 5 mm thick in cement plaster 1:3 as in ceiling surfaces finished even and smooth (without using exta cement) complete all as specified & directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of primer on wall surfaces complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls & applying three coat of white wash complete all as specified and directed
M & L for preparation of newly plastered surfaces of Ceiling & applying three coat of white wash complete all as specified and directed
M&L for 75 mm thick PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M & L for mild steel TMT bars of 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge.
M & L for RCC M-25 grade (design mix) using 20mm graded aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and beams, sides and soffits (if any) of foundation and plinth beams , and similar work, vertical or to batter, flat surfaces of concrete , surface is required to be fair finished complete all as specified and as directed by the Engineer-in-Charge
M & L for M-25 grade (design mix) using 20mm graded aggregates as in columns, pillars, piers, posts and struts complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions, rectangular or polygonal surfaces of concrete , surface is required to be fair finished. complete all as specified and as directed by the Engineer-in-Charge.
M & L for RCC M-25 (design mix) using 20mm graded aggregates as in roof beams, lintel beams/bands, cantilevers, bressummers, lintels over 1.5m span, chajjas etc complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to sides and soffits of floor or roof beams, soffits of lintel beams/ bands, chajjas, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., flat surfaces of concrete ,surface is required to be fair finished. complete all as specified and as directed by the Engineer-in-Charge
M & L for RCC M-25 (design mix) using 20mm graded aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), flat surfaces of concrete , surface is required to be fair finished. complete all as specified and as directed by the Engineer-in-Charge
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, as roughed finished surface of concrete complete all as specified and as directed.
S&F steel ventilators, top hunged type with hinges, peg stay, steel handle, with flyproof,dovetailed or welded complete all as specified and directed.
S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, with glazing bars and flyproof,dovetailed or welded complete all as specified and as directed.
S&F 3mm thick figured glass, pin head type and glazing with oil putty in square n. exc 0.50 Sqm in each pane, complete all as specified and directed.
S&F 3mm thick sheet glass, pin head type and glazing with oil putty in square n. exc 0.50 Sqm in each pane, complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed with wire staples complete all as specified and directed.
M&L for preparing the steel surfaces over 10 cm width or girth & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer complete all as specified and directed.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with M.S. square tube and fixing in opening as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge
S & F factory made solid pannel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded. sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawings on page 146 of SSR Part - II 2004 complete all as specified and directed.
S&F for aluminium anodised barrel tower bolt 150mm long of extruded section complete all as specified and directed.
S&F for aluminium anodised handle 150mm long fabricated type complete all as specified and directed.
S&F aluminium butt hinges ISI marked of size 100mm complete all as specified and directed.
S&F PVC floor/nahani trap with grating 75mm dia fixed with lead joint complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls, laid in trenches or in floors of bore 110mm.complete all as specified
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls, laid in trenches or in floors of bore 75mm.complete all as specified
S&F PVC (SWR) 110 mm bore bends with oval eccess door fixed with cement joint complete all as specified
S&F PVC (SWR) 75 mm bore bends with oval eccess door fixed with cement joint. complete all as specified
S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal with access door with cement joint complete all as specified and directed.
S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal with access door with cement joint complete all as specified and directed.
S&F water tubing 15mm bore, medium grade, ISI marked galvanised with all fittings & fixed to walls, ceiling or laid in floors complete all as specified and directed.
S&F water tubing 20mm bore, medium grade, ISI marked galvanised with all fittings & fixed to walls, ceiling, or laid in floors complete all as specified and directed.
Cutting chases in brick walls, pining in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting exc 10 cm but not exc 20 cm girth complete
M&L for 20 mm thick Granite work (table rubbed and polished) in steps, jambs, pillars, window cills, WHB platform and like over 15 mm thick in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with sahde of granite complete specified and directed.
Rounding to edges of stone slab one edge, such as steps, WHB platform and other similar situations and rubbing and polishing complete
S&F vitreous china white wash basins, including waste pipe, brackets, and connecting pipe Table top basin Kerovit Mazer KB1086 or equivalent complete all as specified and directed.
S&F in repairs vitreous china urnials half stall type incl connecting pipe, spreader, flushing valve and flush/waste pipe fixed to wall complete. Make : Parryware C0580 with C8123 or Jaguar URS WHT 132530
S&F curved shaped 8mm thick frosted glass urinal partition of size 900x 450mm (Make Jaguar JSE-CHR-810UC 450X) incl necessary SS clamp and bottom support to fixed on wall and floor complete as specified.
S&F health faucet cast copper alloy chromium plated with flexible chrome hose and wall hooks complete (Make Jaguar ALD 573 or parryware T9941A1
S&F cast copper alloy chromium plated bottle trap fixed to WHB and wall complete. Make Parryware T3201A1 or equivalent
Supply and fixing in CP brass shower rose (4'' overhead ABS) with 225mm CP brass arm and flange (Prayag Cat No. BOS-87) complete all as specified.
S&F in Soap dish fancy type, fixed to plugs with chromium plated brass screws embedded in the wall complete all as sped & directed.
S & F vitreous china wash down water closet pan EWC (pedestal pattern) white incl fixing bolts & seat cover etc but excluding flushing cistern and flush pipe complete all as specified and directed
Supply and fixing in repairs Squatting pattern Water closet, Orissa pattern of vitreous china Size 580x440mm wide with integral foor rest etc complete all as specified and directed.
S&F PVC valve less syphonic action type, low level flushing cistern, 10 Ltrs capacity . White, with inlet ball valve, float and handle & flush pipe, fixed on walls by drilling holes and using PVC rawl plug of suitable size complete all as specified and directed.
S&F 15mm bore, angle valve/stop cock, long shank & cup (concealed type) cast copper alloy, fancy type chromium plated with screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipes complete all as specified and directed by engr in charge.
S&F chromium plated 15mm bore stop/angle valves, fancy type, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed by Engineer-in-charge.
S&F in repair, 15mm bore brass CP mixer for mixing hot & cold water for wash basin screwed down for iron pipe and fixed complete all as specified.
S&F 15mm bore , 450mm long PVC connection with PTMT nuts complete all as specified and directed.
S&F Chromium plated fancy type bib taps, with capstan heads, screwed down for iron pipe or for brass ferrule & fixed for 15 mm bore pipe complete all as specified & directed.
S&F tubular towel rail brass chromium plated 20mm dia 'D' type 60cm long between flanges complete all as sped & directed.
S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) , hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
S&F ball valves PTMT with high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 25mm bore (min weight 210 gms) complete all as specified and directed.
Supply only liquid water proofing complete all as specified and directed. Make : Fosroc Conplast/Sika
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete
M&L for 100mm thick Plain cment concrete C2, 1:3:6 (using 40mm graded stone aggregate as in sub base of floors or foundations complete all as specified.
M&L for sand filling under floor in foundations inclding watering and consolidation complete.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment coloured, reflective type of approved quality and vibrated with mechanical vibrator complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:4 mixed with water proofing compound @ 3% by weight of cement on fair faces of RCC/stone patti roof surfaces finished even & smooth without using extra cement complete all as specified and directed (WPC will be measured and paid separately).
M & L for five layered roof treatment with APP modified polymeric water proofing membrane, 2mm thick having centre core not less than 100 micron high molecular high density polythylene film (HMHDPE) protected on both sides with high polymeric asphaltic mix and 20 micron HMHDPE film weight not less than 2.60 Kg/ Sqm applied with bonding material using belown type bitumen conforming to IS-702 Grade 85/25 @ 1.20 Kg/ Sqm over bitumen primer conforming to IS- 3384 @ 0.40 Kg/ Sqm with final coat of bonding bitumen grade 85/25 @ 1.20 Kg/ Sqm over APP membrane with all overlaps complete all as specified and directed.
Material and labour for 40mm thick (average consolidated thickness) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate laid in slope as in padding, finished even and smooth on existing slope including provision of 'V' shaped groove 6mm wide and 10mm deep at 1.20 metre interval or parts thereof, both ways on top of PCC padding and filled with mastic bitumen of (1:1) proportion complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all specified and directed.
M & L for PCC 1:2:4 Type B2 using 40 mm graded aggregate as in surface channels and drains & coping, edging rounded or chamfered type etc complete all specified and directed
M&L for 150mm dia in bore SGSW drain pipes laid in trenches and concrete bed to drain pipes of 150mm bore, including packing under, and haunching against the sides of pipes after they are laid and tested cement concrete 1:4:8 type D-2 complete all specified and directed
M& L for Construction of RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 user complete all specified and directed
M& L for Construction of soakage well 2.4 m internal diameter and 3.0 m depth including excavation in any type of soil foundation in PCC 1:3:6 type C2 wall honeycomb masonary with to ring RCC M 25 concrete including intersetic chamber in CM, RCC cover slabe in M 25 / SFRC cover, interconnecting pipe of RCC complete fille with brick bats, complete, all as specified and shown on drg No. CEBZ/TD/78/2011 Sheet 1/2 & 2/2.
M&L for point wiring with 1.5 Sqmm, PVC insulated, unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel anodised terminal box 1.2 mm thick with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories for:-
One light point controlled by one, one way switch.
All as per item No. 86.00 here-in-before but with 2.5 Sqmm, for one 5 pin 5/15 Amp socket on independent board including 2.5 Sqmm stranded copper conductor (FRLS) PVC insulated green in colour as continous earth conductor connected to common earth.
S&F switch piano flush type 5 amps, single pole one way 240 volts.
S&F switch piano flush type 15 amps, single pole one way 240 volts.
S&F socket out let 2 in 1 multipurpose, 3 pin, 5 and 15 Amp flush type complete.
S&F ceiling rose surface bakelite 3 terminals 63.5 x 17 mm.
S & F LED tube light fitting retrofit batten in acrylic linear tube (1x18 watt), 230 V for single LED tube light including 1x18 W LED retrofit bar professional CW 6500 K cover channel, bipin holder, LED power driver, connector block, etc complete with all accessories internally prewired and incuding connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling rose complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F of lamp holder PVC/polycarbonate type with back plate complete all as specified and directed.
Supply and fixing LED lamp 9/10 watt , 230 volts , 50 Hz, B-22 base for fixing in lamp holder and wall mounted decorative light fitting complete all as specified and directed.
Supply and fixing testing and commissioning energy saving street light luminaire suitable for & including 15 watt LED , pressure die cast housing with epoxy powder coated with colour finish and prismatic poly carbonate coverlic cover complete with individual LED lences and accessories fixed on pole by means of bracket of GI pipe, 32mm bore, light grade 1.20 mtr long, cut to length and bent to shape and mild steel clamp of 40 x 6 mm size, (2 Nos) nuts, bolts of required size and length (01 No nut and bolt shall be passed through bracket and clamps complete all as specified and directed.
Supply and fixing street light bracket made of 32 mm GI pipe , 1.2 mtr lenght fixed with two nos of clamp , nut and bolts complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single phase, 230V of size 300 mm sweep with blades and frame and louvers complete fixed and opening of wall with suitable MS bolts, grouted to wall and connecting up including provision of cable from connector to fan with flexible cable 24/0.2mm with copper conductor and necessary fitting arrangements complete all as specified and directed at site. Make - Havells/ Bajaj / Philips.
S&F of MCB distribution board TPN 4 way, 415 volts, double door, with 200 Amps rated bus bar, neutral bar with shrouds, earth bar, IP-43 , made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCBs as incomer and outgoing including blanking plate complete all as specified and directed by Engr-in-Charge.
S&F of MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door IP-43 DB's , made out of sheet steel enclosure, recessed type, factory made powder coated 8 way, 240 volts suitable for housing MCB's including blanking plate complete all as specified and directed.
S & F of MCB SPN, 240 volt, 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
S & F of MCB SP, 240 volt, 6 Amp to 40 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20 mm bore GI med grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2009 complete all as specified and directed.
S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB SP `C' series for geyser complete all as specified and directed
Contd.. Item No. 105.00 (c )Tank shall be insulated with 40 mm thermal grade PU insulation with FRP cladding , Tank stand assembly made of angle of size 38x38x4mm duly pretreated and stove enameled with black colour paint complete (d) Provision of electrical back up with minimum 4 KW heating element including providing one No 32 Amps MCB 10 KA rupturing capacity with Metal clad box and top complete (e) The Solar water heating system shall be provided on Platform on ground made out of PCC and 45 cm in height as per manufacturer direction (f) Heat exchanger shall be cage type and make of stainless steel tube of grade 04 Cr 18 NI of 07 18 NI of IS 1570 (Par-5) -1885 (g) All other pipe / civil work , connection work for PVC tank, as per OEM recommendation electrical work , outlet and inlet thermometer, Air release valve , check valves , gate valves controls and instruments etc all as required shall be deemed to be included in Unit rate quoted . System internal piping shall be ISI marked GI pipe medium class of IS:1239 duly insulated with 50 mm thick rock wool of 48 Kg / cum density and 26 SWG Aluminium cladding Notes :-1. The system shall be tested on completeion to ensure that 300 Ltrs (as specified) of water at 60 degree centigrade is available in hot water tank on a normal day in cold season.
S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
S&F mild steel rolled sections as in main and cross beams, for dtaging of water tank fixed with angle cleats or other connecting plates etc. conforming to Grade E-250 quality `A’ all as specified and directed.
Supply and fixing tubes medium grade GI tubing 20 mm dia with all fitting laid in trenches, fixed on pole/on wall for cable protection all as specified and directed.
Supply and fixing tubes medium grade GI tubing 25 mm dia with all fitting laid in trenches, fixed on pole/on wall for cable protection all as specified and directed.
Supply and fixing tubes light medium grade GI tubing 40 mm dia with all fitting laid in trenches all as specified and directed.
Supply and fixing tubes light medium grade GI tubing 50 mm dia with all fitting laid in trenches all as specified and directed.
S&F Stop valve gun-metal, glove or gate valves with iron wheel head, screwed both ends for GI pipes of size 20mm dia all as specified and directed.
S&F Stop valve gun-metal, glove or gate valves with iron wheel head, screwed both ends for GI pipes of size 25mm dia all as specified and directed.
S&F Stop valve gun-metal, glove or gate valves with iron wheel head, screwed both ends for GI pipes of size 50mm dia all as specified and directed.
Supply and laying including jointing, testing or fixing or passing through pipe, trench or duct commissioning and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade size 16 sqmm, 2 core complete all as specified and directed by Engineer-in-Charge.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Shree Sai Ram Enterprises
MAHARANI CONSTRUCTION
M/s Jai Jinendra Constructions
PD GUPTA AND COMPANY
M/s AKASH CONSTRUCTION CO.
M/S Nexus Projects
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .